At least 397 records · Page 22

Microscopic observations of X-ray and gamma-ray induced decomposition of ammonium perchlorate crystals

The X-ray and gamma-ray induced decomposition of ammonium perchlorate was studied by optical, transmission, and scanning electron microscopy. This material is a commonly used oxidizer in solid propellents which could be employed in deep-space probes, and where they will be subjected to a variety of radiations for as long as ten years. In some respects the radiation-induced damage closely resembles the effects produced by thermal decomposition, but in other respects the results differ markedly. Similar radiation and thermal effects include the following: (1) irregular or ill-defined circular etch pits are formed in both cases; (2) approximately the same size pits are produced; (3) the pit density is similar; (4) the c face is considerably more reactive than the m face; and (5) most importantly, many of the etch pits are aligned in crystallographic directions which are the same for thermal or radiolytic decomposition. Thus, dislocations play an important role in the radiolytic decomposition process.

Herley, P. J.↗

Polarization sensitivity of light diffraction for periodic array of anisotropic gold nanoparticles

This article aims to analyze the first order diffraction intensity of the incident polarized light which is diffracted by the gold nanoparticles array in terms of the surface plasmon effect. The inspected gold nanoparticles array films are built in grating pattern with stripe thickness of 4 μm and diameters of gold nanoparticles ca. 10–56 nm, which are formed by annealing at temperatures of 400, 450, 500, and 550 °C, respectively. The probing light is linearly polarized with wavelengths of 450–800 nm and counterclockwise turns its polarization direction from 0° to 90° during measurements. The results show that the diffraction intensity depends on the anisotropic configuration samples which gold nanoparticles are orientated by analyzing the scanning electron microscope images. It results that the localized surface plasmon effect induced by incident field depends on orientation and causes the sample polarization-sensitive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a Memory Device Failure

The recent failure of a vintage memory device presented a unique challenge to failure analysts. Normally device layouts, fabrication parameters and other technical information were available to assist the analyst in the analysis. However, this device was out of production for many years and the manufacturer was no longer in business, so the information was not available. To further complicate this analysis, the package leads were all but removed making additional electrical testing difficult. Under these conditions, new and innovative methods were used to analyze the failure. The external visual exam, radiography, PIND, and leak testing were performed with nominal results. Since electrical testing was precluded by the short lead lengths, the device was delidded to expose the internal structures for microscopic examination. No failure mechanism was identified. The available electrical data suggested an ESD or low level EOS type mechanism which left no visible surface damage. Due to parallel electrical paths, electrical probing on the chip failed to locate the failure site. Two non-destructive Scanning Electron Microscopy techniques, CIVA (Charge Induced Voltage Alteration) and EBIC (Electron Beam Induced Current), and a liquid crystal decoration technique which detects localized heating were employed to aid in the analysis. CIVA and EBIC isolated two faults in the input circuitry, and the liquid crystal technique further localized two hot spots in regions on two input gates. Removal of the glassivation and metallization revealed multiple failure sites located in the gate oxide of two input transistors suggesting machine (testing) induced damage.

Nicolas, David P.↗

Spatial Mapping of Thermal Boundary Conductance at Metal–Molybdenum Diselenide Interfaces

Improving the thermal transport across interfaces is a necessary consideration for micro- and nanoelectronic devices and necessitates accurate measurement of the thermal boundary conductance (TBC) and understanding of transport mechanisms. Two-dimensional transition-metal dichalcogenides (TMDs) have been studied extensively for their electrical properties, including the metal–TMD electrical contact resistance, but the thermal properties of these interfaces are significantly less explored irrespective of their high importance in their electronic devices. We isolate individual islands of MoSe 2 grown by chemical vapor deposition using photolithography and correlate the 2D variation of TBC with optical microscope images of the MoSe 2 islands. We measure the 2D spatial variation of the TBC at metal–MoSe 2 –SiO 2 interfaces using a modified time-domain thermoreflectance (TDTR) technique, which requires much less time than full TDTR scans. The thermoreflectance signal at a single probe delay time is compared with a correlation curve, which enables us to estimate the change in the signal with respect to the TBC at the metal–MoSe 2 –SiO 2 interface as opposed to recording the decay of the thermoreflectance signal over delay times of several nanoseconds. The results show a higher TBC across the Ti–MoSe 2 –SiO 2 interface compared to Al–MoSe 2 –SiO 2 . An image-clustering method is developed to differentiate the TBC for different numbers of MoSe 2 layers, which reveals that the TBC in single-layer regions is higher than that in the bilayer. Finally, we perform traditional TDTR measurements over a range of delay times and verify that TBC is higher at the Ti–MoSe 2 –SiO 2 interface compared to Al–MoSe 2 –SiO 2 , highlighting the importance of the choice of metal for heat dissipation at electrical contacts in TMD devices.

22 interfacial↗

Direct Visualization of Current-Stimulated Oxygen Migration in YBa 2 Cu 3 O 7–δ Thin Films

The past years have witnessed major advancements in all-electrical doping control on cuprates. In the vast majority of cases, the tuning of charge carrier density has been achieved via electric field effect by means of either a ferroelectric polarization or using a dielectric or electrolyte gating. Unfortunately, these approaches are constrained to rather thin superconducting layers and require large electric fields in order to ensure sizable carrier modulations. In this work, we focus on the investigation of oxygen doping in an extended region through current-stimulated oxygen migration in YBa 2 Cu 3 O 7–δ superconducting bridges. The underlying methodology is rather simple and avoids sophisticated nanofabrication process steps and complex electronics. Here, a patterned multiterminal transport bridge configuration allows us to electrically assess the directional counterflow of oxygen atoms and vacancies. Importantly, the emerging propagating front of current-dependent doping δ is probed in situ by optical microscopy and scanning electron microscopy. The resulting imaging techniques, together with photoinduced conductivity and Raman scattering investigations, reveal an inhomogeneous oxygen vacancy distribution with a controllable propagation speed permitting us to estimate the oxygen diffusivity. These findings provide direct evidence that the microscopic mechanism at play in electrical doping of cuprates involves diffusion of oxygen atoms with the applied current. The resulting fine control of the oxygen content would permit a systematic study of complex phase diagrams and the design of electrically addressable devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of the imaging response of scanning microwave microscopy measurements

In this work, we present the analytical modeling and preliminary experimental results for the choice of the optimal frequencies when performing amplitude and phase measurements with a scanning microwave microscope. In particular, the analysis is related to the reflection mode operation of the instrument, i.e., the acquisition of the complex reflection coefficient data, usually referred as S{sub 11}. The studied configuration is composed of an atomic force microscope with a microwave matched nanometric cantilever probe tip, connected by a λ/2 coaxial cable resonator to a vector network analyzer. The set-up is provided by Keysight Technologies. As a peculiar result, the optimal frequencies, where the maximum sensitivity is achieved, are different for the amplitude and for the phase signals. The analysis is focused on measurements of dielectric samples, like semiconductor devices, textile pieces, and biological specimens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning Probe Microscopy in the Information Age

Scanning probe microscopy (SPM) has brought scientific exploration, visualization, and control to nanoscale. A plethora of measurement approaches and techniques devised around SPM enabled probing structure and functionalities crucial for virtually all areas of science. While high-resolution electron microscopy techniques preceded scanning probes, SPM effectively opened the door to probing the structure–property relationship on length scales spanning 100s of micrometers down to a single atom. As the complexity of the material systems and the scientific questions increased, so too did the SPM techniques. Substantial efforts have been dedicated toward the development of better instrumentation platforms, probes, and novel spectroscopic measurements; however, many opportunities related to data processing and acquisition in SPM are just being realized now. This chapter will describe the recent progress in data-driven SPM by giving a broad overview of the field, the foundation of the scanning tunneling microscope (STM) and the atomic force microscope (AFM), as well as a description behind the operating principles and dynamic modes. A comprehensive overview of the multi-frequency techniques, Band excitation, and general acquisition mode SPM is given, setting the context for the application of big data, machine learning, and artificial intelligence in the field of dynamic SPM.

Collins, Liam↗

Simultaneous imaging of the ferromagnetic and ferroelectric structure in multiferroic heterostructures

By measuring the spin polarization of secondary electrons and the intensity of backscattered electrons generated in a scanning electron microscope, we are able to simultaneously image the ferromagnetic domain structure of a ferromagnetic thin film and the ferroelectric domain structure of the underlying ferroelectric substrate upon which it is grown. Simultaneous imaging allows straightforward, quantitative measurements of the correlations in these complex multiferroic systems. We have successfully imaged domains in CoFe/BFO and Fe/BTO, two systems with very different ferromagnet/ferroelectric coupling mechanisms, demonstrating how this technique provides a new local probe of magneto electric/strictive effects in multiferroic heterostructures.

36 MATERIALS SCIENCE↗

Enhanced electron field emission from plasma-nitrogenated carbon nanotips

Nitrogenated carbon nanotips (NCNTPs) are synthesized by plasma-enhanced hot filament chemical vapor deposition from the hydrogen, methane, and nitrogen gas mixtures with different flow rate ratios of hydrogen to nitrogen. The morphological, structural, compositional, and electron field emission (EFE) properties of the NCNTPs were investigated by field emission scanning electron microscopy, Raman spectroscopy, x ray photoelectron spectroscopy, and EFE high-vacuum system. It is shown that the NCNTPs deposited at an intermediate flow rate ratio of hydrogen to nitrogen feature the best size/shape and pattern uniformity, the highest nanotip density, the highest nitrogen concentration, as well as the best electron field emission performance. Several factors that come into play along with the nitrogen incorporation, such as the combined effect of the plasma sputtering and etching, the transition of sp{sup 3} carbon clusters to sp{sup 2} carbon clusters, the increase of the size of the sp{sup 2} clusters, as well as the reduction of the work function, have been examined to interpret these experimental findings. Our results are highly relevant to the development of the next generation electron field emitters, flat panel displays, atomic force microscope probes, and several other advanced applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesizing new modes for subsurface atomic force microscopy

Non-destructive, nanoscale characterization techniques are needed to understand both synthetic and biological materials. The atomic force microscope uses a force-sensing cantilever with a sharp tip to measure the topography and other properties of surfaces. As the tip is scanned over the surface it experiences attractive and repulsive forces that depend on the chemical and mechanical properties of the sample. Here we show that an atomic force microscope can obtain a range of surface and subsurface information by making use of the nonlinear nanomechanical coupling between the probe and the sample. This technique, which is called mode-synthesizing atomic force microscopy, relies on multi-harmonic forcing of the sample and the probe. A rich spectrum of first- and higher-order couplings is discovered, providing a multitude of new operational modes for force microscopy, and the capabilities of the technique are demonstrated by examining nanofabricated samples and plant cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible drift-compensation system for precise 3D force mapping in severe drift environments

The acquisition of dense 3D data sets is of great importance, but also a challenge for scanning probe microscopy (SPM). Thermal drift often induces severe distortions in the data, which usually constrains the acquisition of dense data sets to experiments under ultra-high vacuum and low-temperature conditions. Atom tracking is an elegant approach to compensate for thermal drift and to position the microscope tip with highest precision. Here, we present a flexible drift compensation system which can easily be connected to existing SPM hardware. Furthermore, we describe a 3D data acquisition and position correction protocol, which is capable of handling large and non-linear drift as typically present in room temperature measurements. This protocol is based on atom-tracking for precise positioning of the tip and we are able to acquire dense 3D data sets over several hours at room temperature. The performance of the protocol is demonstrated by presenting 3D data taken on a CaCO{sub 3}(1014) surface with the data density being as large as 85x85x500 pixel.

36 MATERIALS SCIENCE↗

Structural, dielectric and magnetic studies of (x) Mg{sub 0.2}Cu{sub 0.3}Zn{sub 0.5}Fe{sub 2}O{sub 4} + (1-x) Ba{sub 0.8}Zr{sub 0.2}TiO{sub 3} magnetoelectric composites

The Magneto-electric composites (x) Mg{sub 0.2}Cu{sub 0.3}Zn{sub 0.5}Fe{sub 2}O{sub 4} + (1-x) Ba{sub 0.8}Zr{sub 0.2}TiO{sub 3} (x=15%,30%,45%) were synthesized by sintering mixtures of highly ferroelectric Ba{sub 0.8}Zr{sub 0.2}TiO{sub 3} (BZT) and highly magneto-strictive component Mg{sub 0.2}Cu{sub 0.3}Zn{sub 0.5}Fe{sub 2}O{sub 4} (MCZF). The presences of two phases in magneto-electric composites were probed by X-ray diffraction (XRD) studies. The peaks observed in the XRD spectrum indicated spinel cubic structure for MCZF ferrite and tetragonal perovskite structure for BZT and, both spinel and pervoskite structures for synthesized composites. Surface morphology of the samples has been investigated using Field Emission Scanning Electron Microscope (FESEM). Frequency dependent dielectric properties of synthesized composites were measured from 100 Hz to 1 MHz at RT using HIOKI LCR HI-TESTER. The dielectric dispersion is observed at lower frequencies for the synthesized ME composites. The magnetic properties of synthesized composites were analyzed using a Vibrating Sample Magnetometer (VSM). It is observed that the values of saturation magnetization increases along with the ferrite content.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multidimensional images and aberrations in STEM

Recent advances in scanning transmission electron microscopy (STEM) have led to increased development of multi-dimensional STEM imaging modalities and novel image reconstruction methods. This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens. This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images, such as ptychography and scanning nano-beam diffraction. However, the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance. Here, we examine this paradox by considering the effects of aberrations in both image and diffraction planes, and likewise separate the contributions of pre- and post-sample aberrations. In conclusion, this consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.

Hoglund, Eric R.↗

Learning surface molecular structures via machine vision

Recent advances in high resolution scanning transmission electron and scanning probe microscopies have allowed researchers to perform measurements of materials structural parameters and functional properties in real space with a picometre precision. In many technologically relevant atomic and/or molecular systems, however, the information of interest is distributed spatially in a non-uniform manner and may have a complex multi-dimensional nature. One of the critical issues, therefore, lies in being able to accurately identify (‘read out’) all the individual building blocks in different atomic/molecular architectures, as well as more complex patterns that these blocks may form, on a scale of hundreds and thousands of individual atomic/molecular units. Here we employ machine vision to read and recognize complex molecular assemblies on surfaces. Specifically, we combine Markov random field model and convolutional neural networks to classify structural and rotational states of all individual building blocks in molecular assembly on the metallic surface visualized in high-resolution scanning tunneling microscopy measurements. We show how the obtained full decoding of the system allows us to directly construct a pair density function—a centerpiece in analysis of disorder-property relationship paradigm—as well as to analyze spatial correlations between multiple order parameters at the nanoscale, and elucidate reaction pathway involving molecular conformation changes. Here, the method represents a significant shift in our way of analyzing atomic and/or molecular resolved microscopic images and can be applied to variety of other microscopic measurements of structural, electronic, and magnetic orders in different condensed matter systems.

36 MATERIALS SCIENCE↗

Microstructure and fission products in the UCO kernel of an AGR-1 TRISO fuel particle after post irradiation safety testing

Tristructural isotropic (TRISO) coated particle fuel as a key fuel concept for the High Temperature Gas-cooled Reactors (HTGRs) and a candidate accident tolerant fuel (ATF) has been currently investigated under the US-DOE Advanced Gas Reactor (AGR) fuel development and qualification program. Over the past decades, extensive studies have been conducted to evaluate the fission product release, diffusion on Ag, Pd and Cd in the SiC layer and the TRISO coating system, and post-safety-test performance. However, to date, there are limited reported results on the fuel kernels’ response to irradiation with or without post irradiation high temperature annealing. To incrementally fulfill this knowledge gap extensive studies using transmission electron microscopes (TEM) and atom probe tomography (APT) were conducted on a TRISO fuel particle kernel with a 19.74% 235U enrichment, irradiated to 18.63% FIMA and subsequently subjected to post-safety testing at 1600ºC for 300 hours.. Microstructure characterizations, elemental analysis, and phase identification were conducted using conventional TEM and scanning TEM (STEM) imaging, energy-dispersive X-ray spectroscopy (EDS), selected-area electron diffraction (SAED) and atom probe tomography (APT). The following findings were made: (1) significant reconstructions and phase evolutions occurred in the irradiated and post-safety annealed fuel kernel, and its microstructure consists of two primary phases, namely a “high-Z (atomic mass)” UC phase and a “low-Z” UO phase, (2) no fission gas bubbles are identified within the fuel kernel, that can be attributed to the high temperature post safety annealing, (3) fission products Zr, Nb, Mo, Ru, Tc and Rh were found to preferentially segregate into UC phase or to form metallic precipitates, while the lanthanide fission products tend to stay in the solution of UO phase, (4) Pd was detected in the rod-shaped precipitates, (5) APT data reveals segregation of Te, Pd, and Ag at the UO and UC phase boundary, and (6) Pd is detected in both the UO and UC phases but with an enrichment in the former one.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Polarization Selectivity of Aloof-Beam Electron Energy-Loss Spectroscopy in One-Dimensional ZnO Nanorods

Orientation-dependent electronic properties of wurtzite zinc oxide nanorods are characterized by aloof-beam electron energy-loss spectroscopy (EELS) carried out in a scanning transmission electron microscope (STEM). The two key crystal orientation differentiating transitions specific to the in-plane (13.0 eV) and out-of-plane (11.2 eV) directions with respect to the wurtzite structure are examined by first-principles density-functional theory calculations. We note some degree of orientation dependence at the onset of direct band gap transition near 3.4 eV. We demonstrate that good polarization selectivity can be achieved by placing the electron probe at different locations around the specimen with increasing impact parameter while keeping the beam-specimen orientation fixed. The observed results are qualitatively elucidated in terms of the perpendicular electric fields generated by the fast electron (60 kV) used in the microscope. The fact that good polarization selectivity can be achieved by aloof-beam EELS without the requirement of sample reorientation is an attractive aspect from the characterization method point of view in the STEM-EELS community.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermodynamics of nanodomain formation and breakdown in Scanning Probe Microscopy: Landau-Ginzburg-Devonshire approach

Thermodynamics of tip-induced nanodomain formation in scanning probe microscopy of ferroelectric films and crystals is studied using the analytical Landau-Ginzburg-Devonshire approach and phase-field modeling. The local redistribution of polarization induced by the biased probe apex is analyzed including the effects of polarization gradients, field dependence of dielectric properties, intrinsic domain-wall width, and film thickness. The polarization distribution inside a 'subcritical' nucleus of the domain preceding the nucleation event is shown to be 'soft' (i.e., smooth without domain walls) and localized below the probe, and the electrostatic field distribution is dominated by the tip. In contrast, polarization distribution inside a stable domain is 'hard' (i.e., sharp contrast with delineated domain walls) and the spontaneous polarization reorientation takes place inside a localized spatial region, where the absolute value of the resulting electric field is larger than the thermodynamic coercive field. The calculated coercive biases corresponding to formation of switched domains are in a good agreement with available experimental results for typical ferroelectric materials. The microscopic origin of the observed domain-tip elongation in the region where the probe electric field is much smaller than the intrinsic coercive field is the positive depolarization field in front of the moving-counter domain wall. For infinitely thin domain wall the depolarization field outside the semiellipsoidal domain tip is always higher than the intrinsic coercive field that must initiate the local domain breakdown through the sample depth while the domain length is finite in the energetic approach evolved by Landauer and Molotskii (we refer the phenomenon as Landauer-Molotskii paradox). Our approach provides the solution of the paradox: the domain vertical growth should be accompanied by the increase in the charged domain-wall width.