Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

Generation of Fullspan Leading-Edge 3D Ice Shapes for Swept-Wing Aerodynamic Testing

The deleterious effect of ice accretion on aircraft is often assessed through dry-air flight and wind tunnel testing with artificial ice shapes. This paper describes a method to create fullspan swept-wing artificial ice shapes from partial span ice segments acquired in the NASA Glenn Icing Reserch Tunnel for aerodynamic wind-tunnel testing. Full-scale ice accretion segments were laser scanned from the Inboard, Midspan, and Outboard wing station models of the 65% scale Common Research Model (CRM65) aircraft configuration. These were interpolated and extrapolated using a weighted averaging method to generate fullspan ice shapes from the root to the tip of the CRM65 wing. The results showed that this interpolation method was able to preserve many of the highly three dimensional features typically found on swept-wing ice accretions. The interpolated fullspan ice shapes were then scaled to fit the leading edge of a 8.9% scale version of the CRM65 wing for aerodynamic wind-tunnel testing. Reduced fidelity versions of the fullspan ice shapes were also created where most of the local three-dimensional features were removed. The fullspan artificial ice shapes and the reduced fidelity versions were manufactured using stereolithography.

Icing↗

Aeroacoustic Study of a Subscale Large Civil Transport (STAR) Model – Part 1: Simulations

Results from a computational aeroacoustic study of the Subsonic Transport Aeroacoustic Research (STAR) model are presented. The model, a 26%-scale semispan Boeing 777-200 aircraft, was an inceptive configuration in a comprehensive simulation campaign to accurately predict the airframe noise of a full-scale, large civil transport during landing. The lengthy process of obtaining a high-fidelity, CFD-ready, vetted, digital representation of the model is described in detail. The simulations were performed with the STAR model installed in the NASA Ames 40- by 80-foot full-scale wind tunnel to enable direct comparisons with aerodynamic and acoustic measurements of the model, presented separately in Part 2 of the study. Two versions of the wind tunnel test section were considered. The entire test section was used to simulate the aerodynamic behavior of the model; an open-wall representation of the section was adopted during the acoustic simulations to eliminate wall reflections. To preserve the aerodynamic equivalency of the model for the two simulated tunnel configurations, the open-wall computations were executed at an angle-of-attack one degree higher than that of the corresponding closed-wall tunnel. The effect on aerodynamic behavior of several minor geometry alterations necessary to con-form the simulated to the tested model was assessed – the modifications considerably altered the strength and extent of a flow separation zone on the inboard segment of the flap. Also evaluated was the impact of spatial resolution on aerodynamic and acoustic characteristics of the model – in general, medium resolution was sufficient to establish convergence trends for averaged surface pressure behavior and proper localization of noise sources. After the aeroacoustic characteristics of the baseline configuration were predicted, a toboggan-shaped fairing designed to reduce main landing gear noise was evaluated computationally. Far-field noise spectra for the baseline and toboggan-equipped STAR model were calculated via a Ffowcs-Williams and Hawkings integral approach, with flow quantities on a permeable data surface enclosing the source regions used as input. Results from the simulations indicated that, while the fairing reduced gear noise in the near-field, it had a negligible effect on the far-field noise signature of the model. This trend agreed with previously published experimental results obtained during sub-scale, isolated gear tests and full-scale flight tests

airframe noise↗

Interactive volumetric segmentation for textile micro-tomography data using wavelets and nonlocal means

This work addresses segmentation of volumetric images of woven carbon fiber textiles from micro-tomography data. We propose a semi-supervised algorithm to classify carbon fibers that requires sparse input as opposed to completely labeled images. The main contributions are: (a) design of effective discriminative classifiers, for three-dimensional textile samples, trained on wavelet features for segmentation; (b) coupling of previous step with nonlocal means as simple, efficient alternative to the Potts model; and (c) demonstration of reuse of classifier to diverse samples containing similar content. We evaluate our work by curating test sets of voxels in the absence of a complete ground truth mask. The algorithm obtains an average 0.95 F1 score on test sets and average F1 score of 0.93 on new samples. Finally, we conclude with discussion of failure cases and propose future directions toward analysis of spatiotemporal high-resolution micro-tomography images.

3D image processing↗

Scaling of Sweet-Parker reconnection with secondary islands

Sweet-Parker (collisional) magnetic reconnection at high Lundquist number is modified by secondary islands. Daughton et al. [Phys. Rev. Lett. 103, 065004 (2009)] suggested the Sweet-Parker model governs the fragmented current sheet segments. If true, the reconnection rate would increase by the square root of the number of secondary islands. High Lundquist number resistive magnetohydrodynamic simulations are presented which agree, in a time-averaged sense, with the predicted scaling. This result may have important implications for energy storage before a solar eruption and its subsequent release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE GREEN BANK TELESCOPE H II REGION DISCOVERY SURVEY. III. KINEMATIC DISTANCES

Using the H I emission/absorption method, we resolve the kinematic distance ambiguity and derive distances for 149 of 182 (82%) H II regions discovered by the Green Bank Telescope H II Region Discovery Survey (GBT HRDS). The HRDS is an X-band (9 GHz, 3 cm) GBT survey of 448 previously unknown H II regions in radio recombination line and radio continuum emission. Here, we focus on HRDS sources from 67 Degree-Sign {>=} l {>=} 18 Degree-Sign , where kinematic distances are more reliable. The 25 HRDS sources in this zone that have negative recombination line velocities are unambiguously beyond the orbit of the Sun, up to 20 kpc distant. They are the most distant H II regions yet discovered. We find that 61% of HRDS sources are located at the far distance, 31% at the tangent-point distance, and only 7% at the near distance. 'Bubble' H II regions are not preferentially located at the near distance (as was assumed previously) but average 10 kpc from the Sun. The HRDS nebulae, when combined with a large sample of H II regions with previously known distances, show evidence of spiral structure in two circular arc segments of mean Galactocentric radii of 4.25 and 6.0 kpc. We perform a thorough uncertainty analysis to analyze the effect of using different rotation curves, streaming motions, and a change to the solar circular rotation speed. The median distance uncertainty for our sample of H II regions is only 0.5 kpc, or 5%. This is significantly less than the median difference between the near and far kinematic distances, 6 kpc. The basic Galactic structure results are unchanged after considering these sources of uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-18A-07: Towards 6-Degree-Of-Freedom Real-Time Motion Management in Cancer Radiotherapy

Purpose: Lung tumor motion has been identified as a major issue that deteriorates treatment efficacy for radiotherapy, especially for SBRT. As tighter PTV margins are applied due to translational compensation, tumor rotation will become the dominant factor limiting tumor targeting accuracy. This is the world-first study quantifies lung tumor rotation by utilizing kV images with fiducial markers and a step towards 6-degree-of-freedom real-time cancer radiotherapy. Methods: Three or four gold coils were implanted as tumor surrogates in 3 lung cancer patients. 50 fractions of 8- minute, 10 Hz 4D CBCT projections were acquired for the patients immediately prior or after radiotherapy. The fiducial marker positions are segmented, reconstructed and used to determine tumour rotation by the iterative closest point algorithm. Different data acceptance and filtering methods were applied to accept data or smooth the marker trajectory. Results: The average rotation angles around the left/ right (LR), superior/inferior (SI), anterior/posterior (AP) rotations were found to be 0.8±4.2, -0.8±4.5 and 1.7±3.1 degrees respectively. For 28% of the treatment time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotational motion was detected in 2 of the 3 lung patients. This can be explained by the patient developed atelectasis during the treatment period. Interestingly, no heart beating component of rotation was observed in the power spectrum. Different rotational types were observed within the patient cohort with large variations in the magnitude of the rotation between patients. Conclusions: For the first time, continuous tumor rotation has been measured for lung patients with gold fiducial markers. Tumors were found to undergo rotations of more than 5° for almost a third of the total treatment time. The study also demonstrated the feasibility of using continuously kV images for real-time lung tumour motion adaptive radiotherapy which can potentially reduce treatment margins and side effects. The authors acknowledge the financial support of an NHMRC Australia Fellowship.

60 APPLIED LIFE SCIENCES↗

SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be.

60 APPLIED LIFE SCIENCES↗

SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions in artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.

60 APPLIED LIFE SCIENCES↗

Code Artifact for: Clustering Analysis of Commercial Vehicles Using Automatically Extracted Features from Time Series Data [SWR-21-96]

This repository contains data ingestion, feature extraction, and analysis code used in NREL Technical report "Clustering Analysis of Commercial Vehicles Using Automatically Extracted Features from Time Series Data." The code is written in Python. The ETL and feature extraction code must be run in a Spark context. The analysis code can be run without Spark, provided you have pre-computed features in a CSV file. Analysis code related to the NREL Technical Report NREL/TP-2C00-74212. Includes PySpark functions to perform trip segmentation and feature extraction over big time series data in Apache Spark. Includes "domain specific" features such as Aerodynamic Speed (ft/s), Characteristic Acceleration (ft/s2), Percent Below 55 (%), Percent Zero (%), Stops Per Mile, Average Speed (mph), Maximum Speed (mph), and Speed Standard Deviation (mph). Includes Pyspark UDF to compute "domain agnostic" features using the TSFresh library. This software record also includes the analysis notebooks and code to generate the results in the previously mentioned technical report.

Perr-Sauer, Jordan↗

Molecular clouds in the Carina arm

Results from the first large-scale survey in the CO(J = 1 to 0) line of the Vela-Carina-Centaurus region of the Southern Milky Way are reported. The observations, made with the Columbia University 1.2 m millimeter-wave telescope at Cerro Tololo, were spaced every beamwidth (0.125 deg) in the range 270 deg is less than or = l is less than or = 300 deg and -1 deg less than or = b less then or = 1 deg, with latitude extensions to cover all Carina arm emission beyond absolute b = 1 deg. In a concurrent survey made with the same telescope, every half-degree in latitude and longitude was sampled. Both surveys had a spectral coverage of 330 km/s with a resolution of 1.3 km/s. The Carina arm is the dominant feature in the data. Its abrupt tangent at l is approx. = 280 deg and characteristic loop in the l,v diagram are unmistakable evidence for CO spiral structure. When the emission is integrated over velocity and latitude, the height of the step seen in the tangent direction suggests that the arm-interarm contrast is at least 13:1. Comparison of the CO and H I data shows close agreement between these two species in a segment of the arm lying outside the solar circle. The distribution of the molecular layer about the galactic plane in the outer Galaxy is determined. Between R = 10.5 and 12.5 kpc, the average CO midplane dips from z = -48 to -167 pc below the b = 0 deg plane, following a similar well-known warping of the H I layer. In the same range of radii the half-thickness of the CO layer increases from 112 to 182 pc. Between l = 270 deg and 300 deg, 27 molecular clouds are identified and cataloged along with heliocentric distances and masses. An additional 16 clouds beyond 300 deg are cataloged from an adjoining CO survey made with the same telescope. The average mass for the Carina arm clouds is 1.4x 10(6)M (solar), and the average intercloud spacing along the arm is 700 pc. Comparison of the distribution of the Carina arm clouds with that of similarly massive molecular clouds in the first and second quadrants strongly suggests that the Carina and Sagittarius arms form a single spiral arm approx. 40 kpc long wrapping two-thirds of the way around the Galaxy.

Grabelsky, D. A.↗

Lidar Measurements of Wind, and Cloud & Aerosol Structures using HARLIE at the WVIOP, Sept/Oct 2000

The holographic scanning lidar HARLIE made continuous measurements of aerosol and cloud one-micron backscatter and derived the horizontal wind speed and direction at cloud height over the ARM (SGP) site during the water vapor campaign WVIOP, September 17 - October 6, 2000. Whenever possible, these measurements were compared with Loran-C winds as measured by the routine launches of Vaisala radiosonde balloons scheduled by the ARM project. Taken overall, the agreement between these two types of observation is excellent, which could be taken merely as a validation of the relatively new HARLIE technique. However, the detailed comparison for a given sonde launch clearly requires that, out of the HARLIE data which are taken all the time at all altitudes, one must select those segments that match the altitude-time trajectory of the sonde. Moreover, the conical HARLIE scan at a 45 deg. elevation angle covers a wide area that is more representative of the average wind conditions above the site than the isolated track of the sonde's ascent. We suggest that the HARLIE instrument offers a more general and improved representation of the horizontal wind profile whenever there is sufficient backscatter by clouds and aerosols for lidar operation. HARLIE is a rugged and compact lidar that operates from aircraft as well as from the ground and has been used in several meteorological campaigns. As a "direct detection" lidar, HARLIE does not require the complexity of a coherent detection system. The data reduction algorithms facilitate the rapid and accurate determination of wind speed and direction at all altitudes. Wind measurements and HARLIE performance data from WVIOP 2000 and other campaigns will be presented.

Schwemmer, Geary↗

SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.

60 APPLIED LIFE SCIENCES↗

Q-switched and mode-locked Er{sup 3+}-doped fibre laser using a single-multi-single fibre filter and piezoelectric

The active Q-switched and passive mode-locked Er{sup 3+}-doped all-fibre laser is presented. The fibre laser centre wavelength is located at 1563 nm and determined by the homemade singlemulti- single (SMS) in-line fibre filter. The laser spectrum width is nearly 0.1 nm. The active Q-switched mechanism relies on the polarisation state control using a piezoelectric to press a segment of passive fibre on the circular cavity. The nonlinear polarisation rotation technology is used to realise the passive self-started modelocked operation. In the passive mode-locked regimes, the output average power is 2.1 mW, repetition frequency is 11.96 MHz, and single pulse energy is 0.18 nJ. With the 100-Hz Q-switched regimes running, the output average power is 1.5 mW. The total Q-switched pulse width is 15 μs, and every Q-switched pulse is made up by several tens of mode-locked peak pulses. The calculated output pulse energy of the Q-switched fibre laser is about 15 μJ, and the energy of every mode-locked pulse is about 64–68 nJ during a Q-switched pulse taking into account the power fraction propagating between pulses. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

On estimating the effects of clock instability with flicker noise characteristics

A scheme for flicker noise generation is given. The second approach is that of successive segmentation: A clock fluctuation is represented by 2N piecewise linear segments and then converted into a summation of N+1 triangular pulse train functions. The statistics of the clock instability are then formulated in terms of two sample variances at N+1 specified averaging times. The summation converges very rapidly that a value of N 6 is seldom necessary. An application to radio interferometric geodesy shows excellent agreement between the two approaches. Limitations to and the relative merits of the two approaches are discussed.

Wu, S. C.↗

Uncertainty and Sensitivity Analyses of Duct Propagation Models

This paper presents results of uncertainty and sensitivity analyses conducted to assess the relative merits of three duct propagation codes. Results from this study are intended to support identification of a "working envelope" within which to use the various approaches underlying these propagation codes. This investigation considers a segmented liner configuration that models the NASA Langley Grazing Incidence Tube, for which a large set of measured data was available. For the uncertainty analysis, the selected input parameters (source sound pressure level, average Mach number, liner impedance, exit impedance, static pressure and static temperature) are randomly varied over a range of values. Uncertainty limits (95% confidence levels) are computed for the predicted values from each code, and are compared with the corresponding 95% confidence intervals in the measured data. Generally, the mean values of the predicted attenuation are observed to track the mean values of the measured attenuation quite well and predicted confidence intervals tend to be larger in the presence of mean flow. A two-level, six factor sensitivity study is also conducted in which the six inputs are varied one at a time to assess their effect on the predicted attenuation. As expected, the results demonstrate the liner resistance and reactance to be the most important input parameters. They also indicate the exit impedance is a significant contributor to uncertainty in the predicted attenuation.

Nark, Douglas M.↗

Mechanical Characterization of In and Out-of-Autoclave Cured Composite Panels for Large Launch Vehicles

Two manufacturing demonstration panels (1/16th-arc-segments of 10 m diameter cylinder) were fabricated under the composites part of the Lightweight Space Structures and Materials program. Both panels were of sandwich construction with aluminum core and 8-ply quasi-isotropic graphite/epoxy facesheets. One of the panels was constructed with in-autoclave curable unidirectional prepreg (IM7/977-3) and the second with out-of-autoclave unidirectional prepreg (T40-800B/5320-1). Following NDE inspection, each panel was divided into a number of small specimens for material property characterization and a large (0.914 m wide by 1.524 m long) panel for a buckling study. Results from the small specimen tests were used to (a) assess the fabrication quality of each 1/16th arc segment panel and (b) to develop and/or verify basic material property inputs to Finite Element analysis models. The mechanical performance of the two material systems is assessed at the coupon level by comparing average measured properties such as flatwise tension, edgewise compression, and facesheet tension. The buckling response of the 0.914 m wide by 1.524 m long panel provided a comparison between the in- and out-of autoclave systems at a larger scale.

Kellas, Sotiris↗