Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Nondestructive measurement of the grid ratio using a single image

The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T{sub p}), and scatter transmission (T{sub s}). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53{+-}0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microplasma source for optogalvanic spectroscopy of nanogram samples

The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both {sup 13}C-to-{sup 12}C and {sup 14}C-to-{sup 12}C ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e.g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

Deuterium scattering experiments in CTEQ global QCD analyses: a comparative investigation

Abstract Experimental measurements in deep-inelastic scattering and lepton-pair production on deuterium targets play an important role in the flavor separation of u and d (anti)quarks in global QCD analyses of the parton distribution functions (PDFs) of the nucleon. We investigate the impact of theoretical corrections accounting for the light-nuclear structure of the deuteron upon the fitted u , d -quark, gluon, and other PDFs in the CJ15 and CT18 families of next-to-leading order CTEQ global analyses. The investigation is done using the $$L_2$$ L 2 sensitivity statistical method, which provides a common metric to quantify the strength of experimental constraints on various PDFs and ratios of PDFs in the two distinct fitting frameworks. Using the $$L_2$$ L 2 sensitivity and other approaches, we examine the compatibility of deuteron data sets with other fitted experiments under varied implementations of the deuteron corrections. We find that freely-fitted deuteron corrections modify the PDF uncertainty at large momentum fractions and will be relevant for future PDFs affecting electroweak precision measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Complementary Methods of Synchrotron Radiation Powder Diffraction and Pair Distribution Function to Refine Crystal Structures with High Quality Parameters—A Review

Determination of the atomic-scale structures of certain fine-grained minerals using single-crystal X-ray diffraction (XRD) has been challenging because they commonly occur as submicron and nanocrystals in the geological environment. Synchrotron powder diffraction and scattering techniques are useful complementary methods for studying this type of minerals. In this review, we discussed three example studies investigated by combined methods of synchrotron radiation XRD and pair distribution function (PDF) techniques: (1) low-temperature cristobalite; (2) kaolinite; and (3) vernadite. Powder XRD is useful to determine the average structure including unit-cell parameters, fractional atomic coordinates, occupancies and isotropic atomic displacement parameters. X-ray/Neutron PDF methods are sensitive to study the local structure with anisotropic atomic displacement parameters (ADP). The results and case studies suggest that the crystal structure and high-quality ADP values can be obtained using the combined methods. The method can be useful to characterize crystals and minerals that are not suitable for single-crystal XRD.

58 GEOSCIENCES↗

Sensitivity map computation in adaptive electrical capacitance volume tomography with multielectrode excitations

Electrical capacitance tomography (ECT) is a low‐cost, high‐speed imaging technique useful in many industrial settings. ECT is predicated on the knowledge of sensitivity maps between capacitance electrodes that blanket the imaging domain. The simultaneous activation of multiple electrodes can be advantageous to manipulate the resulting field distributions and capture additional spatial information for imaging purposes. However, conventional methods for sensitivity map computation in ECT are not adequate in the presence of multielectrode activation because the mutual coupling between electrodes is not properly accounted for. This coupling becomes especially critical in adaptive electrical capacitance volume tomography (AECVT) sensors, where signals from many small electrode segments are combined into synthetic electrodes. A more general approach is presented for sensitivity map computation in AECVT based on the actual posteriori (induced) charge distributions rather than the conventional approach based on boundary conditions with no account for electrode interactions.

Zeeshan, Z.↗

Design of refractive index sensing based on 2D PhC air-slot width-modulated line-defect microcavity

In this paper, we propose an investigated sensor array based on two-dimensional photonic crystal air-slot width-modulated line-defect microcavity. This sensor consists of a waveguide coupled with microcavity. To achieve a high quality factor, we have tuned some parameters of the microcavity. The principle of sensing is based on the resonance wavelength shift when the refractive index is changed. For sensitivity analysis, we proposed various conventional designs (A–D). We demonstrated that the design D has the highest sensitivity. An air-slot is created within the line-defect. The existence of the slots enhances the light-matter interactions. The simulation results are obtained by using finite-deference time-domain method. The sensitivity can achieve 400 nm/RIU, with detection limit of 2.98 × 10{sup −5} RIU.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A fixed mass method for the Kramers-Moyal expansion—Application to time series with outliers

Extraction of stochastic and deterministic components from empirical data—necessary for the reconstruction of the dynamics of the system—is discussed. We determine both components using the Kramers-Moyal expansion. In our earlier papers, we obtained large fluctuations in the magnitude of both terms for rare or extreme valued events in the data. Calculations for such events are burdened by an unsatisfactory quality of the statistics. In general, the method is sensitive to the binning procedure applied for the construction of histograms. Instead of the commonly used constant width of bins, we use here a constant number of counts for each bin. This approach—the fixed mass method—allows to include in the calculation events, which do not yield satisfactory statistics in the fixed bin width method. The method developed is general. To demonstrate its properties, here, we present the modified Kramers-Moyal expansion method and discuss its properties by the application of the fixed mass method to four representative heart rate variability recordings with different numbers of ectopic beats. These beats may be rare events as well as outlying, i.e., very small or very large heart cycle lengths. The properties of ectopic beats are important not only for medical diagnostic purposes but the occurrence of ectopic beats is a general example of the kind of variability that occurs in a signal with outliers. To show that the method is general, we also present results for two examples of data from very different areas of science: daily temperatures at a large European city and recordings of traffics on a highway. Using the fixed mass method, to assess the dynamics leading to the outlying events we studied the occurrence of higher order terms of the Kramers-Moyal expansion in the recordings. We found that the higher order terms of the Kramers-Moyal expansion are negligible for heart rate variability. This finding opens the possibility of the application of the Langevin equation to the whole range of empirical signals containing rare or outlying events. Note, however, that the higher order terms are non-negligible for the other data studied here and for it the Langevin equation is not applicable as a model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RINGFINDER: Automated detection of galaxy-scale gravitational lenses in ground-based multi-filter imaging data

We present RINGFINDER, a tool for finding galaxy-scale strong gravitational lenses in multi-band imaging data. By construction, the method is sensitive to configurations involving a massive foreground ETG and a faint, background, blue source. RINGFINDER detects the presence of blue residuals embedded in an otherwise smooth red light distribution by difference imaging in two bands. The method is automated for efficient application to current and future surveys, having originally been designed for the 150 deg{sup 2} Canada-France-Hawaii Telescope Legacy Survey (CFHTLS). We describe each of the steps of RINGFINDER. We then carry out extensive simulations to assess completeness and purity. For sources with magnification μ > 4, RINGFINDER reaches 42% (25%) completeness and 29% (86%) purity before (after) visual inspection. The completeness of RINGFINDER is substantially improved in the particular range of Einstein radii 0.''8 ≤ R {sub Ein} ≤ 2.''0 and lensed images brighter than g = 22.5, where it can be as high as ∼70%. RINGFINDER does not introduce any significant bias in the source or deflector population. We conclude by presenting the final catalog of RINGFINDER CFHTLS galaxy-scale strong lens candidates. Additional information obtained with Hubble Space Telescope and Keck adaptive optics high-resolution imaging, and with Keck and Very Large Telescope spectroscopy, is used to assess the validity of our classification and measure the redshift of the foreground and the background objects. From an initial sample of 640,000 ETGs, RINGFINDER returns 2500 candidates, which we further reduce by visual inspection to 330 candidates. We confirm 33 new gravitational lenses from the main sample of candidates, plus an additional 16 systems taken from earlier versions of RINGFINDER. First applications are presented in the Strong Lensing Legacy Survey galaxy-scale lens sample paper series.

79 ASTRONOMY AND ASTROPHYSICS↗

Targeted quantification of functional enzyme dynamics in environmental samples for microbially mediated biogeochemical processes: Targeted quantification of functional enzyme dynamics

Microbially mediated biogeochemical processes are catalyzed by enzymes that control the transformation of carbon, nitrogen, and other elements in environment. The dynamic linkage between enzymes and biogeochemical species transformation has, however, rarely been investigated because of the lack of analytical approaches to efficiently and reliably quantify enzymes and their dynamics in soils and sediments. Herein, we developed a signature peptide-based technique for sensitively quantifying dissimilatory and assimilatory enzymes using nitrate-reducing enzymes in a hyporheic zone sediment as an example. Moreover, the measured changes in enzyme concentration were found to correlate with the nitrate reduction rate in a way different from that inferred from biogeochemical models based on biomass or functional genes as surrogates for functional enzymes. This phenomenon has important implications for understanding and modeling the dynamics of microbial community functions and biogeochemical processes in environments. Our results also demonstrate the importance of enzyme quantification for the identification and interrogation of those biogeochemical processes with low metabolite concentrations as a result of faster enzyme-catalyzed consumption of metabolites than their production. The dynamic enzyme behaviors provide a basis for the development of enzyme-based models to describe the relationship between the microbial community and biogeochemical processes.

Li, Minjing↗

High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data

Purpose: In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles ({approx}50 deg.). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. Methods: By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. Results: We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to conventional circular scan micro-CT. Conclusions: Autofocus-corrected, theoretically-exact cone-beam reconstruction is a viable option for reducing acquisition time in high-resolution micro-CT imaging. It also opens up the possibility of efficiently imaging long objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric field determination in transient plasmas: in situ & non-invasive methods

Abstract One of the primary basic plasma parameters within transient nonequilibrium plasmas is the reduced electric field strength, roughly understood as the ratio of the electrical energy given to the charged species between two collisions. While physical probes have historically been used for electric field measurements, recent advances in high intensity lasers and sensitive detection methods have allowed for non-invasive optical electric field determination in nearly any discharge configuration with time-resolution up to the sub-nanosecond range and sub-millimeter spatial resolution. This topical review serves to highlight several non-invasive methods for in situ electric field strength determination in transient plasmas ranging from high vacuum environments to atmospheric pressure and above. We will discuss the advantages and proper implementation of (i) laser induced fluorescence dip spectroscopy for measurements in low pressure RF discharges, (ii) optical emission spectroscopy based methods for nitrogen, helium or hydrogen containing discharges, (iii) electric field induced coherent Raman scattering, and (iv) electric field induced second harmonic generation. The physical mechanism for each method will be described as well as basic implementation and highlighting recent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stacking the invisibles: A guided search for low-luminosity Milky Way satellites

Almost every known low-luminosity Milky Way dwarf spheroidal (dSph) satellite galaxy contains at least one RR Lyrae star. Assuming that a fraction of distant (60 < d {sub helio} < 100 kpc) Galactic halo RR Lyrae stars are members of yet to be discovered low-luminosity dSph galaxies, we perform a guided search for these low-luminosity dSph galaxies. In order to detect the presence of dSph galaxies, we combine stars selected from more than 123 sightlines centered on RR Lyrae stars identified by the Palomar Transient Factory. We find that this method is sensitive enough to detect the presence of Segue 1-like galaxies (M{sub V}=−1.5{sub −0.8}{sup +0.6}, r{sub h} = 30 pc) even if only ∼20 sightlines were occupied by such dSph galaxies. Yet, when our method is applied to the Sloan Digital Sky Survey Data Release 10 imaging catalog, no signal is detected. An application of our method to sightlines occupied by pairs of close (<200 pc) horizontal branch stars, also did not yield a detection. Thus, we place upper limits on the number of low-luminosity dSph galaxies with half-light radii from 30 pc to 120 pc, and in the probed volume of the halo. Stronger constraints on the luminosity function may be obtained by applying our method to sightlines centered on RR Lyrae stars selected from the Pan-STARRS1 survey, and eventually, from the Large Synoptic Survey Telescope. In Appendix A, we present spectroscopic observations of an RRab star in the Boötes 3 dSph and a light curve of an RRab star near the Boötes 2 dSph.

79 ASTRONOMY AND ASTROPHYSICS↗

(U) Preliminary Notes on Bondarenko Self-Shielded Cross Section Sensitivities

The Bondarenko method for resonance self-shielding was recently implemented in the PARTISN multigroup discrete ordinates code. This report derives the sensitivities of self-shielded cross sections with respect to nuclide densities and the subsequent sensitivities of k eff with respect to nuclide densities. Numerical results are presented for two test problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Probing the limits of statistical neutron capture for the r process: Experimental constraints on 141 Cs nuclear level densities

The r-process abundance peaks, particularly near mass number A ∼ 130, reflect underlying nuclear structure effects such as closed neutron shells, yet modeling the nucleosynthesis in this region remains hindered by uncertain neutron-capture rates. These rates are especially sensitive to nuclear level densities (NLDs) and γ-ray strength functions of neutron-rich nuclei, where experimental data are scarce. We present the first experimental constraint on the NLD of 141 Cs using the β-Oslo method, extending sensitivity to the neutron-rich regime near the N = 82 closed shell. Our data allow for critical calibration of microscopic NLD models and reveal that 141 Cs lies near the limit of statistical model applicability. Using this experimental input, we evaluate radiative neutron-capture rates across neighboring isotones using both Hauser–Feshbach (HF) and High Fidelity Resonance (HFR) models. Our results show order-of-magnitude rate increases for nuclei along the N = 86 line, signaling a transition to resonance-dominated capture in this region. These findings underscore the importance of constraining NLDs to improve r-process reaction network predictions, particularly in environments where the validity of statistical models breaks down.

Nuclear level density↗

CONFIRMATION OF THE COMPACTNESS OF A z = 1.91 QUIESCENT GALAXY WITH HUBBLE SPACE TELESCOPE'S WIDE FIELD CAMERA 3

We present very deep Wide Field Camera 3 (WFC3) photometry of a massive, compact galaxy located in the Hubble Ultra Deep Field. This quiescent galaxy has a spectroscopic redshift z = 1.91 and has been identified as an extremely compact galaxy by Daddi et al. We use new H {sub F160W} imaging data obtained with Hubble Space Telescope/WFC3 to measure the deconvolved surface brightness profile to H {approx} 28 mag arcsec{sup -2}. We find that the surface brightness profile is well approximated by an n = 3.7 Sersic profile. Our deconvolved profile is constructed by a new technique which corrects the best-fit Sersic profile with the residual of the fit to the observed image. This allows for galaxy profiles which deviate from a Sersic profile. We determine the effective radius of this galaxy: r{sub e} = 0.42 {+-} 0.14 kpc in the observed H {sub F160W} band. We show that this result is robust to deviations from the Sersic model used in the fit. We test the sensitivity of our analysis to faint 'wings' in the profile using simulated galaxy images consisting of a bright compact component and a faint extended component. We find that due to the combination of the WFC3 imaging depth and our method's sensitivity to extended faint emission we can accurately trace the intrinsic surface brightness profile, and that we can therefore confidently rule out the existence of a faint extended envelope around the observed galaxy down to our surface brightness limit. These results confirm that the galaxy lies a factor {approx}10 off from the local mass-size relation.

79 ASTRONOMY AND ASTROPHYSICS↗