Search NASA⌕ Search

SEARCH · Search NASA

Results for “single-photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Simple coplanar waveguide resonator mask targeting metal-substrate interface

This white paper presents a single-layer mask, found at https://github.com/Boulder-Cryogenic-Quantum-Testbed/simple-resonator-mask. It is designed for fabrication of superconducting microwave resonators towards 1:1 comparisons of dielectric losses from the metal-substrate interface. Finite-element electromagnetic simulations are used to determine participation ratios of the four major regions of the on-chip devices, as well as to confirm lack of crosstalk between neighboring devices and demonstrate coupling tunability over three orders of magnitude. This mask is intended as an open-source community resource for facilitating precise and accurate comparisons of materials in the single-photon, millikelvin regime.

Kopas, Cameron J.↗

Impedance matched superconducting nanowire photodetector for single- and multi-photon detection

Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, IB×Zload, where Zload is limited to 50Ω in standard RF electronics. This limit is broken/exceeded by interfacing the 50Ω load and the SNSPD using an integrated superconducting transmission line taper. The taper is a transformer that effectively loads the SNSPD with high impedance without latching. The taper increases the amplitude of the detector output while preserving the fast rising edge. Using a taper with a starting width of 500 nm, a 3.6× higher pulse amplitude, 3.7× faster slew rate, and 25.1 ps smaller timing jitter was observed. The taper also makes the detector's output voltage sensitive to the number of photon-induced hotspots and enables photon number resolution.

Zhu, Di↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Excess and New Physics Searches with MicroBooNE

The MicroBooNE detector is a liquid argon TPC located in the Booster Neutrino Beamline at Fermilab. Leveraging the unique capabilities of the LArTPC technology to distinguish photons from electron showers, one of MicroBooNE's primary goals is to investigate MiniBooNE low energy excess (LEE), an anomalously large observed rate of events containing a single electromagnetic shower. This electromagnetic shower could be caused by electrons, photons, or electron-positron (e+e-) pairs, which would all look very similar in the MiniBooNE Cherenkov detector, but could have distinct signatures in the MicroBooNE LArTPC. In this poster, we present an updated and new search for these signals, including searches for electron neutrino, single-photons, and e+e- pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Neutrino Dipole Moments and Radiative Signatures from Partial Compositeness

We investigate composite neutrino models where heavy neutrinos emerge as bound states from a near-conformal strongly coupled sector. Standard Model neutrinos mix with these composite singlets via an inverse seesaw mechanism, where the anomalous scaling dimensions of the composite-sector operators naturally suppress light neutrino masses to sub-eV scales. Matching the conformal dynamics onto low-energy theory yields enhanced electromagnetic transition dipole operators with couplings $d_{μN} \sim 10^{-6}$-$10^{-8}\,\mathrm{GeV}^{-1}$, parametrically larger than the loop-level predictions of minimal Dirac or Majorana models. We carry out a dedicated event-level simulation of the production-and-decay chain $νX \to \mathcal{U} X \to νγX$ and compute the resulting event rates at MiniBooNE and MINERvA within the model, accounting for the composite production cross section and decay kinematics in detail. We further present predictions for the photon energy, angular, and multiplicity distributions. For the benchmark scenarios accessible at these experiments the radiative signal is predominantly single-photon; the composite structure additionally permits fragmentation of the up-scattered state into multiple heavy neutrinos, each decaying as $N\toνγ$, with multi-photon final states emerging for lighter compositeness scales or higher beam energies as a qualitatively new probe of the composite dynamics.

Assi, Benoît [Cincinnati U.; Fermilab] (ORCID:0000↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Emission from Bright Excitons in Asymmetrically Strained Colloidal CdSe/Cd x Zn 1– x Se Quantum Dots

Colloidal CdSe quantum dots (QDs) designed with a high degree of asymmetric internal strain have recently been shown to host a number of desirable optical properties including subthermal room-temperature line widths, suppressed spectral diffusion, and high photoluminescence (PL) quantum yields. It remains an open question, however, whether they are well-suited for applications requiring emission of identical single photons. Here we measure the low-temperature PL dynamics and the polarization-resolved fluorescence line narrowing spectra from ensembles of these strained QDs. Our spectroscopy reveals the radiative recombination rates of bright and dark excitons, the relaxation rate between the two, and the energy spectra of the quantized acoustic phonons in the QDs that can contribute to relaxation processes. In comparison to conventional colloidal CdSe/ZnS core/shell QDs, we find that in asymmetrically strained CdSe QDs over six times more light is emitted directly by the bright exciton. Furthermore, these results are therefore encouraging for the prospects of chemically synthesized colloidal QDs as emitters of single indistinguishable photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-zero photon bioimaging by fusing deep learning and ultralow-light microscopy

Enhancing the reliability and reproducibility of optical microscopy by reducing specimen irradiance continues to be an important biotechnology target. As irradiance levels are reduced, however, the particle nature of light is heightened, giving rise to Poisson noise, or photon sparsity that restricts only a few (0.5%) image pixels to comprise a photon. Photon sparsity can be addressed by collecting approximately 200 photons per pixel; this, however, requires long acquisitions and, as such, suboptimal imaging rates. Here, we introduce near-zero photon bioimaging, a method that operates at kHz rates and 10,000-fold lower irradiance than standard microscopy. To achieve this level of performance, we uniquely combined a judiciously designed epifluorescence microscope enabling ultralow background levels and AI that learns to reconstruct biological images from as low as 0.01 photons per pixel. We demonstrate that near-zero photon bioimaging captures the structure of multicellular and subcellular features with high fidelity, including features represented by nearly zero photons. Beyond optical microscopy, the near-zero photon bioimaging paradigm can be applied in remote sensing, covert applications, and biomedical imaging that utilize damaging or quantum light.

AI↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Linear optics and projective measurements for fun and profit

The technique of projective measurements in linear optics can provide an apparent, efficient nonlinear interaction between photons, which is technically problematic otherwise. We present an application of such a technique to prepare large photon-number path entanglement.

linear↗