Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Automation and control of laser wakefield accelerators using Bayesian optimization

Laser wakefield accelerators promise to revolutionize many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimization of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimized its outputs by simultaneously varying up to six parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimization of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

43 PARTICLE ACCELERATORS↗

In-Situ Luminescence Imaging of Perovskite Solar Cells Demonstrates Increasing Spatial Nonuniformity Upon Light-Soaking Degradation

In this work we investigate degradation rates of triplecation mixed-halide perovskite p-i-n solar cells. We present an accelerated stress testing procedure using periodic blue light-soaking at elevated temperatures until devices reach ~80% of their initial efficiency. We track light-induced degradation via in-situ: photoluminescence (PL), current-voltage (I-V) curves, and transient photovoltage. Devices underwent 165 hours of light bias at 65degrees C. Results suggest that spatial uniformity in PL intensity decreases as device degradation increases. This investigation lays the groundwork to address the current gap in understanding the interplay between device performance and the evolution of macroscopic features in perovskite solar cells. Thus, we believe spatial characterization techniques will play a crucial role in the commercialization of perovskite solar cells.

imaging↗

On angiography with a Thomson laser-electron X-ray generator

We consider a possibility of application of laser-electron X-ray generators for diagnosing the vessel status of internal organs. It is shown that modern lasers and linear accelerators can be used for the development of angiographic instruments of a new type with an increased spatial and temporal resolution while maintaining or reducing the radiation load on the patient and medical staff. Such improvements in diagnostic and ambient factors cannot be achieved with the use of X-ray tubes. All particular estimates and calculations have been performed for a contrast agent based on iodine compounds. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

DUST PRODUCTION AND PARTICLE ACCELERATION IN SUPERNOVA 1987A REVEALED WITH ALMA

Supernova (SN) explosions are crucial engines driving the evolution of galaxies by shock heating gas, increasing the metallicity, creating dust, and accelerating energetic particles. In 2012 we used the Atacama Large Millimeter/Submillimeter Array to observe SN 1987A, one of the best-observed supernovae since the invention of the telescope. We present spatially resolved images at 450 μm, 870 μm, 1.4 mm, and 2.8 mm, an important transition wavelength range. Longer wavelength emission is dominated by synchrotron radiation from shock-accelerated particles, shorter wavelengths by emission from the largest mass of dust measured in a supernova remnant (>0.2 M {sub ☉}). For the first time we show unambiguously that this dust has formed in the inner ejecta (the cold remnants of the exploded star's core). The dust emission is concentrated at the center of the remnant, so the dust has not yet been affected by the shocks. If a significant fraction survives, and if SN 1987A is typical, supernovae are important cosmological dust producers.

79 ASTRONOMY AND ASTROPHYSICS↗

Alkali-silica reaction products and cracks: X-ray micro-tomography-based analysis of their spatial-temporal evolution at a mesoscale

In this study, we propose a laboratory-scale methodology, based on X-ray micro-tomography and caesium (Cs) as a contrast agent, to advance the understanding of cracking due to alkali-silica reaction (ASR) in concrete. The methodology allows achieving a completely non-destructive and time-lapse characterization of the spatial-temporal patterns of both the cracks and the ASR products. While Cs addition slightly accelerated the ASR kinetics, the crack patterns, with and without Cs addition, were statistically equivalent. Cracks with ASR products appeared first in the aggregates, close to the interface with the cement paste. They propagated afterwards towards the aggregates interior. Some products were then extruded for several mm into air voids and cracks in the cement paste. This process suggests that, in the early stage, the ASR products may be a low-viscosity gel that can flow away from the source aggregate and may settle later elsewhere as a rigid phase, upon calcium uptake.

36 MATERIALS SCIENCE↗

Krylov Deferred Correction Accelerated Method of Lines Transpose for Parabolic Problems

In this paper, a new class of numerical methods for the accurate and efficient solutions of parabolic partial differential equations is presented. Unlike traditional method of lines (MoL), the new {\bf \it Krylov deferred correction (KDC) accelerated method of lines transpose (MoL^T)} first discretizes the temporal direction using Gaussian type nodes and spectral integration, and symbolically applies low-order time marching schemes to form a preconditioned elliptic system, which is then solved iteratively using Newton-Krylov techniques such as Newton-GMRES or Newton-BiCGStab method. Each function evaluation in the Newton-Krylov method is simply one low-order time-stepping approximation of the error by solving a decoupled system using available fast elliptic equation solvers. Preliminary numerical experiments show that the KDC accelerated MoL^T technique is unconditionally stable, can be spectrally accurate in both temporal and spatial directions, and allows optimal time-step sizes in long-time simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NO{sub x} emission trends for China, 1995-2004 : the view from the ground and the view from space.

A rapid increase of NO{sub 2} columns over China has been observed by satellite instruments in recent years. We present a 10-a regional trend of NO{sub x} emissions in China from 1995 to 2004 using a bottom-up methodology and compare the emission trends with the NO{sub 2} column trends observed from GOME and SCIAMACHY, the two spaceborne instruments. We use a dynamic methodology to reflect the dramatic change in China's NO{sub x} emissions caused by energy growth and technology renewal. We use a scenario analysis approach to identify the possible sources of uncertainties in the current bottom-up inventory, in comparison with the satellite observation data. Our best estimates for China's NO{sub x} emissions are 10.9 Tg in 1995 and 18.6 Tg in 2004, increasing by 70% during the period considered. NO{sub x} emissions and satellite-based NO{sub 2} columns show broad agreement in temporal evolution and spatial distribution. Both the emission inventory data and the satellite observations indicate a continuous and accelerating growth rate between 1996 and 2004 over east central China. However, the growth rate from the emission inventory is lower than that from the satellite observations. From 1996 to 2004, NO{sub x} emissions over the region increased by 61% according to the inventory, while a 95% increase in the NO{sub 2} columns measured by satellite was observed during the same period. We found good agreement during summertime but a large discrepancy during wintertime. The consistency between the summertime trends suggests that the bias cannot be due to systematic error of activity data or emission factors. The reasons for the discrepancy cannot yet be fully identified, but possible explanations include an underestimation in seasonal emission variations, variability of meteorology, NO{sub x} injection height, and the increasing trend of sulfate aerosols.

54 ENVIRONMENTAL SCIENCES↗

Space dependent, full orbit effects on runaway electron dynamics in tokamak plasmas

The dynamics of RE (runaway electrons) in fusion plasmas span a wide range of temporal scales, from the fast gyro-motion, ∼10−11 s, to the observational time scales, ∼10−2→1 s. To cope with this scale separation, RE are usually studied within the bounce-average or the guiding center approximations. Although these approximations have yielded valuable insights, a study with predictive capabilities of RE in fusion plasmas calls for the incorporation of full orbit effects in configuration space in the presence of three-dimensional magnetic fields. We present numerical results on this problem using the Kinetic Orbit Runaway electrons Code that follows relativistic electrons in general electric and magnetic fields under the full Lorentz force, collisions, and radiation losses. At relativistic energies, the main energy loss is due to radiation damping, which we incorporate using the Landau-Lifshitz formulation of the Abraham-Lorentz-Dirac force. The main focus is on full orbit effects on synchrotron radiation. It is shown that even in the absence of magnetic field stochasticty, neglecting orbit dynamics can introduce significant errors in the computation of the total radiated power and the synchrotron spectra. The statistics of collisionless (i.e., full orbit induced) pitch angle dispersion, and its key role played on synchrotron radiation, are studied in detail. Numerical results are also presented on the pitch angle dependence of the spatial confinement of RE and on full orbit effects on the competition of electric field acceleration and radiation damping. Finally, full orbit calculations are used to explore the limitations of gyro-averaging in the relativistic regime. To explore the practical impact of the results, DIII-D and ITER-like parameters are used in the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IMPLICATIONS OF TEMPORAL DEVELOPMENT OF LOCALIZED ULTRAVIOLET AND HARD X-RAY EMISSION FOR LARGE SOLAR FLARES

Ultraviolet and hard X-ray (HXR) emissions in solar flares provide observational signatures of the interaction of flare-accelerated particles with the chromospheric plasma. Earlier studies have shown clear evidence of temporal and spatial relationships between UV and HXR emission, suggesting a common physical origin. However, more recent spatially resolved case studies suggest significant variations in the spatial distributions of the emission signatures, implying that the large-scale magnetic topology of the flaring region must play a crucial role in the spatial and temporal development of the localized UV and HXR emission. We present here an analysis of spatially resolved HXR emission and localized UV emission sources from 11 M and X class flares with observations from RHESSI and high-cadence 1600 A observations from TRACE. Within each flare we address the overall temporal development of individual UV sources and relate them to associated impulsive bursts within the HXR flare profile. We find, for these large flares, that in the initial impulsive bursts of flare activity, the majority of the temporally correlated emission evolves in a series of localized co-spatial sources along the UV ribbons consistent with previous two-dimensional reconnection pictures. However, observations of impulses late in flares, show significant departures from the traditional co-spatial/co-temporal picture. The new results include extended UV ribbons with no corresponding HXR emission and marked spatial separations between temporally correlated sources of UV and HXR emission. In seven of the multi-burst events, we observe the development of independent sets of UV and HXR sources corresponding to the individual impulses seen in the temporal profile. The observed separations and the spatial development of co-temporal emission in multi-burst events emphasize the importance of a complex and time varying magnetic topology in shaping the observed emission distributions in both wavelengths. In four of the events, we observe late developing UV sources which show no relationship with the HXR emission. In these events, the emission sources show a strong relationship with lower energy, more spatially extended X-ray emission believed to be of thermal origin. This suggests that, in the later phase of these complex flares, emission from thermal processes comes to dominate non-thermal processes in the production of the UV emission.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY INVESTIGATION OF THE DIFFUSE EMISSION AROUND PLAUSIBLE {gamma}-RAY EMITTING PULSAR WIND NEBULAE IN KOOKABURRA REGION

We report on the results from Suzaku X-ray observations of the radio complex region called Kookaburra, which includes two adjacent TeV {gamma}-ray sources HESS J1418-609 and HESS J1420-607. The Suzaku observation revealed X-ray diffuse emission around a middle-aged pulsar PSR J1420-6048 and a plausible pulsar wind nebula (PWN) Rabbit with elongated sizes of {sigma}{sub X} = 1.'66 and {sigma}{sub X} = 1.'49, respectively. The peaks of the diffuse X-ray emission are located within the {gamma}-ray excess maps obtained by H.E.S.S. and the offsets from the {gamma}-ray peaks are 2.'8 for PSR J1420-6048 and 4.'5 for Rabbit. The X-ray spectra of the two sources were well reproduced by absorbed power-law models with {Gamma} = 1.7-2.3. The spectral shapes tend to become softer according to the distance from the X-ray peaks. Assuming the one-zone electron emission model as the first-order approximation, the ambient magnetic field strengths of HESS J1420-607 and HESS J1418-609 can be estimated as 3 {mu}G and 2.5 {mu}G, respectively. The X-ray spectral and spatial properties strongly support that both TeV sources are PWNe, in which electrons and positrons accelerated at termination shocks of the pulsar winds are losing their energies via the synchrotron radiation and inverse Compton scattering as they are transported outward.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomalous Diffusion Equations with Multiplicative Acceleration

A generalization of the model of Lévy walks with traps is considered. The main difference between the model under consideration and the already existing models is the introduction of multiplicative particle acceleration at collisions. The introduction of acceleration transfers the consideration of walks to coordinate–momentum phase space, which allows both the spatial distribution of particles and their spectrum to be obtained. The kinetic equations in coordinate–momentum phase space have been derived for the case of walks with two possible states. This system of equations in a special case is shown to be reduced to ordinary Lévy walks. This system of kinetic equations admits of integration over the spatial variable, which transfers the consideration only to momentum space and allows the spectrum to be calculated. An exact solution of the kinetic equations can be obtained in terms of the Laplace–Mellin transform. The inverse transform can be performed only for the asymptotic solutions. The calculated spectra are compared with the results of Monte Carlo simulations, which confirm the validity of the derived asymptotics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AMReX: Block-structured adaptive mesh refinement for multiphysics applications

Block-structured adaptive mesh refinement (AMR) provides the basis for the temporal and spatial discretization strategy for a number of Exascale Computing Project applications in the areas of accelerator design, additive manufacturing, astrophysics, combustion, cosmology, multiphase flow, and wind plant modeling. AMReX is a software framework that provides a unified infrastructure with the functionality needed for these and other AMR applications to be able to effectively and efficiently utilize machines from laptops to exascale architectures. AMR reduces the computational cost and memory footprint compared to a uniform mesh while preserving accurate descriptions of different physical processes in complex multiphysics algorithms. AMReX supports algorithms that solve systems of partial differential equations in simple or complex geometries and those that use particles and/or particle–mesh operations to represent component physical processes. In this article, we will discuss the core elements of the AMReX framework such as data containers and iterators as well as several specialized operations to meet the needs of the application projects. In addition, we will highlight the strategy that the AMReX team is pursuing to achieve highly performant code across a range of accelerator-based architectures for a variety of different applications.

Zhang, Weiqun↗

Two-beam Bragg diffraction, filtering, and delays

We summarize transmission and reflection amplitudes of Bragg-crystals based on two-beam Bragg diffraction theory. Then, we consider a specific case of infinitely thick and symmetrical Bragg-crystal and its reflective properties in spectral and angular domain. We obtain analytical expressions for filtering width and respective delay amplitudes, temporal delay from spectral phase shift and spatial displacement from angular phase shift.

43 PARTICLE ACCELERATORS↗

Advanced analysis of metal distributions in human hair

A variety of techniques (secondary electron microscopy with energy dispersive X-ray analysis, time-of-flight-secondary ion mass spectrometry, and synchrotron X-ray fluorescence) were utilized to distinguish metal contamination occurring in hair arising from endogenous uptake from an individual exposed to a polluted environment, in this case a lead smelter. Evidence was sought for elements less affected by contamination and potentially indicative of biogenic activity. The unique combination of surface sensitivity, spatial resolution, and detection limits used here has provided new insight regarding hair analysis. Metals such as Ca, Fe, and Pb appeared to have little representative value of endogenous uptake and were mainly due to contamination. Cu and Zn, however, demonstrate behaviors worthy of further investigation into relating hair concentrations to endogenous function.

43 PARTICLE ACCELERATORS↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

A quality assurance program for image quality of cone-beam CT guidance in radiation therapy

The clinical introduction of volumetric x-ray image-guided radiotherapy systems necessitates formal commissioning of the hardware and image-guided processes to be used and drafts quality assurance (QA) for both hardware and processes. Satisfying both requirements provides confidence on the system's ability to manage geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, the authors present data from their QA program tracking the image quality performance of ten volumetric systems over a period of 3 years. These data are subsequently used to establish evidence-based tolerances for a QA program. The volumetric imaging systems used in this work combines a linear accelerator with conventional x-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis, in a cone-beam computed tomography (CBCT) configuration. In the spirit of the AAPM Report No. 74, the present work presents the image quality portion of their QA program; the aspects of the QA protocol addressing imaging geometry have been presented elsewhere. Specifically, the authors are presenting data demonstrating the high linearity of CT numbers, the uniformity of axial reconstructions, and the high contrast spatial resolution of ten CBCT systems (1-2 mm) from two commercial vendors. They are also presenting data accumulated over the period of several months demonstrating the long-term stability of the flat-panel detector and of the distances measured on reconstructed volumetric images. Their tests demonstrate that each specific CBCT system has unique performance. In addition, scattered x rays are shown to influence the imaging performance in terms of spatial resolution, axial reconstruction uniformity, and the linearity of CT numbers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-shot measurements of pulse-front tilt in intense ps laser pulses and its effect on accelerated electron and ion beam characteristics (invited)

Here we report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗