Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

LDRD Macromolcule Radiolysis Poster

Moving toward a circular carbon economy depends on enabling reuse of carbon-based macromolecules and increased recycling of waste products into higher value products. Macromolecules are challenging to valorize into products easily converted into liquid fuel or chemical feedstocks, due to their large and sometimes heterogeneous network of polymeric bonds. The novel aspect of this project is to show a proof of principle that radiolysis of macromolecules using “waste” radiation from energy production in the presence of radical capping donors presents an attractive opportunity to break down complex macromolecules into smaller molecules while controlling re-polymerization. This approach offers a new, cost-efficient way to utilize “waste” radiation and heat byproducts of nuclear energy production to convert a simple mixture of complex molecules into a complex mixture of small molecules, to be utilized as an energy source by the fuel industry, or to create value-added feedstocks for new polymers or commodity chemicals. Ionizing radiation can be harnessed to convert energy to molecules, adding value to low-value macromolecules as they are broken down into smaller, more easily separated feedstocks or fuels to be converted to a value-added product. This project will test 2 hypotheses. Hypothesis 1: Macromolecular materials that comprise biomass and coal or other macromolecules can be infused with radical capping donors (RCDs), and gamma irradiation of the resulting mixtures will produce ensembles of lower-molecular weight chemicals that can be more easily separated. If this expectation is realized, the conversion chemistry can be optimized by adjusting the feedstock composition, irradiation time, and choice of RCD.

02 - PETROLEUM↗

A variant of the MenB strain of Synechocystis sp. PCC 6803 disrupts a stress response pathway allowing DMPBQ to occupy the A 1 sites of photosystem I

Phylloquinone (PhQ) plays a unique role in photosynthesis as the A1A and A1B intermediates in light-driven electron transfer in Photosystem I (PSI). When PhQ biosynthesis is inhibited by deletion of the menB gene in the cyanobacterium Synechocystis sp. PCC 6803, previous studies have shown that plastoquinone-9 (PQ-9) occupies the A 1 sites. However, a recent cryo-electron microscopy structure of a strain of ΔmenB from the year 2023 revealed an unusual quinone in the A 1 sites with a benzoquinone headgroup similar to PQ-9 and a phytyl tail similar to PhQ. Here, we investigate its biosynthesis and binding properties. Mass spectrometry confirms that PSI from the 2023 ΔmenB strain contains 2,3-dimethyl-5-phytyl-1,4-benzoquinone (DMPBQ), while PSI from the original strain contains PQ-9. Whole genome sequencing reveals that a mutation in slr1737 (tocopherol cyclase) leads to the accumulation of DMPBQ, an intermediate in the tocopherol biosynthetic pathway. Transient optical and electron paramagnetic resonance spectroscopy studies show that when DMPBQ occupies the A 1 sites, it does not exchange with exogenously supplied PhQ in contrast to PQ-9, which exchanges readily. We propose that the slr1737 mutation in the 2023 ΔmenB strain is a likely candidate for the source of the phenotype. This new strain has sacrificed tocopherol synthesis, the absence of which is known to have no effect on growth under low stress conditions, resulting in incorporation of DMPBQ in the A 1 sites. The tighter binding and function of DMPBQ likely allow this ΔmenB strain to outcompete its peers under optimal growth conditions and thus dominate the population.

2,3-dimethyl-5-phytyl-1,4-benzoquinone↗

Untargeted Spatial Metabolomics and Spatial Proteomics on the Same Tissue Section

An increasing number of spatial multiomic workflows have been recently developed. Some of these approaches have leveraged initial mass spectrometry imaging (MSI)-based spatial metabolomics to inform region of interest (ROI) selection for downstream spatial proteomics. However, these workflows have been limited by varied substrate requirements between modalities or have required analyzing serial sections (i.e., one section per modality). To mitigate these issues, we present a novel multiomic workflow that uses desorption electrospray ionization (DESI)-MSI to identify representative spatial metabolite patterns on-tissue prior to spatial proteomic analyses on the same tissue section. Further, this workflow is demonstrated here with a model mammalian tissue (coronal rat brain section) mounted on a polyethylene naphthalate-membrane slide. Initial DESI-MSI resulted in 160 annotations (SwissLipids) within to the METASPACE platform (≤20% false discovery rate). A segmentation map from the annotated ion images informed downstream ROI selection for spatial proteomics characterization from the same sample. The unspecific substrate requirements and minimal sample disruption inherent to DESI-MSI allowed for an optimized, downstream spatial proteomics assay, resulting in 3888 ± 240 to 4717 ± 48 proteins being confidently directed per ROI (200 µm x 200 µm). Finally, we demonstrate the integration of multiomic information, where we found ceramide localization to be correlated with SMPD3 abundance (ceramide synthesis protein), and we also utilized protein abundance to resolve metabolite isomeric ambiguity. Overall, the integration of DESI-MSI into the multiomic workflow allows for complementary spatial and molecular-level information to be achieved from optimized implementations of each MS assay inherent to the workflow itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved spatial resolution for spot sampling in thermal desorption atomic force microscopy – mass spectrometry via rapid heating functions

The key to advancing materials is to understand and control their structure and chemistry. However, thorough chemical characterization is challenging since existing techniques characterize only a few properties of the specimen, thereby necessitating multiple measurement platforms to acquire the necessary information. The multimodal combination of atomic force microscopy (AFM) and mass spectrometry (MS) transcends existing analytical capabilities for nanometer scale spatially resolved correlation of the chemical and physical properties of a sample surface. One such hybrid system employs heated AFM cantilevers for thermal desorption (TD) sampling of molecules from a surface and subsequent gas phase ionization and detection of the liberated species by MS. Here in this paper, we report on the use of voltage pulse trains to tailor cantilever heating such that spot sampling size was reduced and mass spectral signal was improved compared to constant voltage, static heating of the cantilever. Desorption efficiency (DE), defined as the quotient of the mass spectral signal intensity and the volume of the desorption crater, was used to judge the effectiveness of a particular tailored heating function. To guide the development and optimization of the heating functions and aid in interpreting experimental results, a 1D finite element model was developed that predicted the cantilever response to different heating functions. Three tailored heating functions that used different combinations, magnitudes, and durations of rectangular voltage pulses, were used for surface spot sampling. The resultant sampling spot size and DE were compared to the same metrics obtained with the conventional method that uses a single voltage pulse. Using a model system composed of a thin film of ink containing pigment yellow 74 as a model system, desorption craters shrunk from 2 μm, using the conventional approach, to 310 nm using the optimum tailored heating function. This same pulsed heating function produced a 381× improvement in the DE and an 8× improvement in spatial resolution compared to the conventional heating approach showing that signal/amount of material sampled was improved significantly by this new cantilever heating strategy.

36 MATERIALS SCIENCE↗

High-sensitivity detection of polycyclic aromatic hydrocarbons adsorbed onto soot particles using laser desorption/laser ionization/time-of-flight mass spectrometry: An approach to studying the soot inception process in low-pressure flames

Species adsorbed at the surfaces of soot particles sampled at different locations in a low-pressure methane flame have been analyzed. The analysis method is laser desorption/laser ionization/time-of-flight mass spectrometry (LD/LI/TOF-MS) applied to soot particles deposited on a filter after probe extraction in the flame. In order to fully characterize the experimental apparatus, a strategy of systematic investigations has been adopted, beginning with the study of less complex systems constituted by model soot (standard polycyclic aromatic hydrocarbons, PAHs, adsorbed on black carbon), and then natural soot sampled from a literature reference ethylene flame. This characterization allowed a good understanding of the analytical response of PAHs to the desorption and ionization processes and the definition of the optimal experimental conditions. The soot PAH content was then investigated on a low-pressure methane/oxygen/nitrogen premixed flat flame ({phi} = 2.32) as a function of the sampling height above the burner (HAB). The obtained mass spectra are reproducible, fragment-free, well resolved in the analyzed m/z range and they are characterized by an excellent signal-to-noise ratio. They all feature regular peak sequences, where each signal peak has been assigned to the most stable high-temperature-formed PAHs. The structure of the mass spectra depends on the sampling HAB into the flame, i.e., on the reaction time. An original contribution to the data interpretation comes from the development of a new sampling method that makes it possible to infer hypotheses about the PAH partition between the gas phase and the soot particles. This method highlights the presence of high-mass PAHs in the soot nucleation zone, and it suggests the importance of heterogeneous reactions occurring between flame PAHs and soot particles. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Radon and material radiopurity assessment for the NEXT double beta decay experiment

The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in {sup 136}Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY11 Status Report

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today's confirmatory assay methods. This document is a progress report for FY2011 PNNL analysis and algorithm development. Progress made by PNNL in FY2011 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model, which accounts for self-shielding effects using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the true self-shielding functions of the used fuel assembly models. The potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space was demonstrated. Also, in FY2011, PNNL continued to develop an analytical model. Such efforts included the addition of six more non-fissile absorbers in the analytical shielding function and the non-uniformity of the neutron flux across the LSDS assay chamber. A hybrid analytical-empirical approach was developed to determine the mass of total Pu (sum of the masses of 239Pu, 240Pu, and 241Pu), which is an important quantity in safeguards. Results using this hybrid method were of approximately the same accuracy as the pure empirical approach. In addition, total Pu with much better accuracy with the hybrid approach than the pure analytical approach. In FY2012, PNNL will continue efforts to optimize its empirical model and minimize its reliance on calibration data. In addition, PNNL will continue to develop an analytical model, considering effects such as neutron-scattering in the fuel and cladding, as well as neutrons streaming through gaps between fuel pins in the fuel assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of frequency and applied voltage of an atmospheric-pressure dielectric-barrier discharge on breakdown and hydroxyl-radical generation with a liquid electrode

This work examines the effect of the frequency and peak applied voltage on hydroxyl-radical generation in a dielectric-barrier plasma discharge between a metallic needle electrode and one electrode covered with dielectric. The authors examine a system that can expose up to 96 liquid samples in an automated fashion without human intervention beyond setting the initial software configuration. Then, hydroxylradical concentration, measured through coumarin fluorescence, was measured for 5 s plasma exposures generated under different highvoltage conditions with frequencies from 2 to 16 kHz and amplitudes from 4 to 9 kV. Their results show that an increase in frequency and/or applied voltage, within the range prescribed above and the limits of the high-voltage power supply, can yield up to a 150% increase in fluorescence with an equivalent hydroxyl-radical increase. Applications using typical previous methods, such as the Fenton Reaction, are limited in that they continuously generate hydroxyl radicals over millisecond and longer intervals. These results establish the electrical parameters that can now be applied to polymers, like proteins, which show three dimensional structures that are flexible and fluctuate on a microsecond and nanosecond time scale, with hydroxyl-radical generation on this time scale using this device. Additionally, plasma exposures may be optimized for a great variety of proteins, devices and techniques, where hydroxyl-radical generation is of utmost importance, reducing exposure time and potential subjection of samples to harmful side effects.

42 ENGINEERING↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

Orzechowska, G. E.↗

Hydrogen Production from Polyethylene Pyrolysis

Hydrogen is anticipated to play a pivotal role in the future of clean energy and decarbonization efforts, serving as an energy storage medium, a power generation source, and a clean fuel for transportation. While most hydrogen is produced from carbonaceous fossil feedstocks like natural gas, petroleum, and coal, there is growing interest in using refuse-derived fuels such as waste plastics and municipal solid waste (MSW) as alternative feedstocks. Thermochemical processes such as pyrolysis and catalytic cracking can convert nonrecyclable plastics and organic MSW components to produce hydrogen with lower life cycle greenhouse gas emissions when coupled with CO 2 capture. Such approaches not only address waste-management challenges but also reduce methane emissions from landfills. Furthermore, waste feedstocks are low cost and can support meeting demands for hydrogen across various industries. In this work we examined production of hydrogen from high-density polyethylene (HDPE) as a model polymer using pyrolysis. Analytical studies of pyrolysis utilizing gas chromatography–mass spectrometry (GC/MS) provide insights into conversion pathways for plastic waste, potentially reducing the environmental footprint of traditional hydrogen production methods. This work generates a baseline methodology for hydrogen production from plastic pyrolysis with and without a catalyst and the necessary product distribution baseline from key single plastics. The effect of pyrolysis temperature on the conversion of HDPE was evaluated both with and without a catalyst(s), and the product distributions measured via GC/MS were identified and hydrogen formation was quantified. These results will help guide future research efforts to optimize catalysts and processes for more efficient hydrogen production and mixed plastic waste management.

Catalysts↗

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Collidoscope: An Improved Tool for Computing Collisional Cross-Sections with the Trajectory Method

Ion mobility-mass spectrometry (IM-MS) can be a powerful tool for determining structural information about ions in the gas phase, from small covalent analytes to large, native-like or denatured proteins and complexes. For large biomolecular ions, which may have a wide variety of possible gas-phase conformations and multiple charge sites, quantitative, physically explicit modeling of collisional cross sections (CCSs) for comparison to IMS data can be challenging and time-consuming. We present a “trajectory method” (TM) based CCS calculator, named “Collidoscope,” which utilizes parallel processing and optimized trajectory sampling, and implements both He and N{sub 2} as collision gas options. Also included is a charge-placement algorithm for determining probable charge site configurations for protonated protein ions given an input geometry in pdb file format. Results from Collidoscope are compared with those from the current state-of-the-art CCS simulation suite, IMoS. Collidoscope CCSs are within 4% of IMoS values for ions with masses from ~18 Da to ~800 kDa. Collidoscope CCSs using X-ray crystal geometries are typically within a few percent of IM-MS experimental values for ions with mass up to ~3.5 kDa (melittin), and discrepancies for larger ions up to ~800 kDa (GroEL) are attributed in large part to changes in ion structure during and after the electrospray process. Due to its physically explicit modeling of scattering, computational efficiency, and accuracy, Collidoscope can be a valuable tool for IM-MS research, especially for large biomolecular ions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing Ion Transmission in Differential Mobility Spectrometry

We provide modeling and experimental data describing the dominant ion-loss mechanisms for differential mobility spectrometry (DMS). Ion motion is considered from the inlet region of the mobility analyzer to the DMS exit, and losses resulting from diffusion to electrode surfaces, insufficient effective gap, ion fragmentation, and fringing field effects are considered for a commercial DMS system with 1-mm gap height. It is shown that losses due to diffusion and radial oscillations can be minimized with careful consideration of residence time, electrode spacing, gas flow rate, and waveform frequency. Fragmentation effects can be minimized by limitation of the separation field. When these parameters were optimized, fringing field effects at the DMS inlet contributed the most to signal reduction. We also describe a new DMS cell configuration that improves the gas dynamics at the mobility cell inlet. The new cell provides a gas jet that decreases the residence time for ions within the fringing field region, resulting in at least twofold increase in ion signal as determined by experimental data and simulations. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Oxide dissolution and oxygen diffusion scenarios in niobium and implications on the Bean–Livingston barrier in superconducting cavities

We generalize a native Nb2O5 dissolution model [G. Ciovati, Appl. Phys. Lett. 89, 022507 (2006)] to sequential overlayer dissolutions, multilayer dissolution, and realistic temperature profiles, which may be applicable to other materials. The model is applied to secondary ion mass spectrometry depth profile measurements for varying temperature profiles and two-step oxide dissolution in Nb and found to agree well. In the context of the Meissner screening response due to impurity profiles on the length scale of the London penetration depth, the shallow diffusion of O impurities results in a substantial decrease in the peak supercurrent density near the surface. In this framework, oxide dissolution and oxygen diffusion can account for a rise in peak supportable magnetic field in SRF cavities with baking time and a suppression after the optimal baking time is reached, in good agreement with peak-field baking temperatures and times as well as recent quench field measurements.

Lechner, Eric↗