Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrum analyzers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Charged-particle mutagenesis II. Mutagenic effects of high energy charged particles in normal human fibroblasts

The biological effects of high LET charged particles are a subject of great concern with regard to the prediction of radiation risk in space. In this report, mutagenic effects of high LET charged particles are quantitatively measured using primary cultures of human skin fibroblasts, and the spectrum of induced mutations are analyzed. The LET of the charged particles ranged from 25 KeV/micrometer to 975 KeV/micrometer with particle energy (on the cells) between 94-603 MeV/u. The X-chromosome linked hypoxanthine guanine phosphoribosyl transferase (hprt) locus was used as the target gene. Exposure to these high LET charged particles resulted in exponential survival curves; whereas, mutation induction was fitted by a linear model. The Relative Biological Effect (RBE) for cell-killing ranged from 3.73 to 1.25, while that for mutant induction ranged from 5.74 to 0.48. Maximum RBE values were obtained at the LET of 150 keV/micrometer. The inactivation cross-section (alpha i) and the action cross-section for mutant induction (alpha m) ranged from 2.2 to 92.0 micrometer2 and 0.09 to 5.56 x 10(-3) micrometer2, respectively. The maximum values were obtained by 56Fe with an LET of 200 keV/micrometer. The mutagenicity (alpha m/alpha i) ranged from 2.05 to 7.99 x 10(-5) with the maximum value at 150 keV/micrometer. Furthermore, molecular analysis of mutants induced by charged particles indicates that higher LET beams are more likely to cause larger deletions in the hprt locus.

NASA Center JSC↗

XMM-Newton Spectroscopy of the X-ray Detected Broad Absorption Line QSO CSO 755

We present the results from XMM-Newton observations of the highly optically polarized broad absorption line quasar (BALQSO) CSO 755. By analyzing its X-ray spectrum with a total of approximately 3000 photons we find that this source has an X-ray continuum of "typical" radio-quiet quasars, with a photon index of Gamma=1.83, and a rather flat (X-ray bright) intrinsic optical-to-X-ray spectral slope of alpha_ox=- 1.51. The source shows evidence for intrinsic absorption, and fitting the spectrum with a neutral-absorption model gives a column density of N_H approximately 1.2x10^22 cm^{-2}; this is among the lowest X-ray columns measured for BALQSOs. We do not detect, with high significance, any other absorption features in the X-ray spectrum. Upper limits we place on the rest-frame equivalent width of a neutral (ionized) Fe K-alpha line, less than =180 eV (less than =120 eV), and on the Compton-reflection component parameter, R less than =0.2, suggest that most of the X-rays from the source are directly observed rather than being scattered or reflected; this is also supported by the relatively flat intrinsic alpha ox we measure. The possibility that most of the X-ray flux is scattered due to the high level of UV-optical polarization is ruled out. Considering data for 46 BALQSOs from the literature, including CSO 755, we have found that the UV-optical continuum polarization level of BALQSOs is not correlated with any of their X-ray properties. A lack of significant short-term and long-term X-ray flux variations in the source may be attributed to a large black-hole mass in CSO 755. We note that another luminous BALQSO, PG 2112+059, has both similar shallow C IV BALs and moderate X-ray absorption.

Brandt, Niel↗

Real Time Phase Noise Meter Based on a Digital Signal Processor

A digital signal-processing meter for phase noise measurement on sinusoidal signals is dealt with. It enlists a special hardware architecture, made up of a core digital signal processor connected to a data acquisition board, and takes advantage of a quadrature demodulation-based measurement scheme, already proposed by the authors. Thanks to an efficient measurement process and an optimized implementation of its fundamental stages, the proposed meter succeeds in exploiting all hardware resources in such an effective way as to gain high performance and real-time operation. For input frequencies up to some hundreds of kilohertz, the meter is capable both of updating phase noise power spectrum while seamlessly capturing the analyzed signal into its memory, and granting as good frequency resolution as few units of hertz.

phase noise↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and measurement of atmospheric ethane (C2H6) from a 1951 infrared solar spectrum

C2H6 absorption features in the 2980/cm spectral region of the solar spectrum recorded in April, 1951 were analyzed to determine the total vertical column amount and average free tropospheric mixing ratio of C2H6 above Jungfraujoch in the Swiss Alps. The PQ1 subbranch is the best isolated of the three C2H6 features in the 1951 spectrum, with an equivalent width of 0.0099 + or - 0.0025/cm. Results give a total vertical column amount of 9.7 x 10 to the 15th C2H6 molecules/sq cm, with an accuracy of + or - 30 percent. March 1981 measurements from this region give a mixing ratio of about 2.0 ppbv, 2.2 times larger than the 1951 value, suggesting a long-term increase in the free tropospheric C2H6 concentration over western Europe.

Rinsland, Curtis P.↗

Infrared Database for Process Support Materials

Process support materials' compatibility with cleaning processes is critical to ensure final hardware cleanliness and that performance requirements are met. Previous discovery of potential contaminants in process materials shows the need for incoming materials testing and establishment of a process materials database. The Contamination Control Team of the Materials, Processes, and Manufacturing (MP&M) Department at Marshall Space Flight Center (MSFC) has initiated the development of such an infrared (IR) database, called the MSFC Process Materials IR database, of the common process support materials used at MSFC. These process support materials include solvents, wiper cloths, gloves, bagging materials, etc. Testing includes evaluation of the potential of gloves, wiper cloths, and other items to transfer contamination to handled articles in the absence of solvent exposure, and the potential for solvent exposure to induce material degradation. This Technical Memorandum (TM) summarizes the initial testing completed through December 2002. It is anticipated that additional testing will be conducted with updates provided in future TMs.Materials were analyzed using two different IR techniques: (1) Dry transference and (2) liquid extraction testing. The first of these techniques utilized the Nicolet Magna 750 IR spectrometer outfitted with a horizontal attenuated total reflectance (HATR) crystal accessory. The region from 650 to 4,000 wave numbers was analyzed, and 50 scans were performed per IR spectrum. A dry transference test was conducted by applying each sample with hand pressure to the HATR crystal to first obtain a spectrum of the parent material. The material was then removed from the HATR crystal and analyzed to determine the presence of any residues. If volatile, liquid samples were examined both prior to and following evaporation.The second technique was to perform an extraction test with each sample in five different solvents.Once the scans were complete for both the dry transference and the extraction tests, the residue from each scan was interpreted.

Bennett, K. E.↗

The absorption spectrum of titanium between 1900 A and 2315 A

The absorption spectrum of Ti I has been analyzed in the region 1900-2315 A. The list contains 219 lines, of which 64 have been identified as transitions between the ground term and terms of the odd configurations (3d + 4s)3 np (n = 4, 5). Sixteen new energy levels have been found, and three odd level values have been revised. Most of the identified Ti I lines are present in the solar spectrum.

Forsberg, P.↗

Chandra Grating Spectroscopy of Three Hot White Dwarfs

High-resolution soft X-ray spectroscopic observations of single hot white dwarfs are scarce. With the Chandra Low-Energy Transmission Grating, we have observed two white dwarfs, one is of spectral type DA (LB1919) and the other is a non-DA of spectral type PG1159 (PG1520+525). The spectra of both stars are analyzed, together with an archival Chandra spectrum of another DA white dwarf (GD246). Aims. The soft X-ray spectra of the two DA white dwarfs are investigated in order to study the effect of gravitational settling and radiative levitation of metals in their photospheres. LB1919 is of interest because it has a significantly lower metallicity than DAs with otherwise similar atmospheric parameters. GD246 is the only white dwarf known that shows identifiable individual iron lines in the soft X-ray range. For the PG1159 star, a precise effective temperature determination is performed in order to confine the position of the blue edge of the GW Vir instability region in the HRD. Methods. The Chandra spectra are analyzed with chemically homogeneous as well as stratified NLTE model atmospheres that assume equilibrium between gravitational settling and radiative acceleration of chemical elements. Archival EUV and UV spectra obtained with EUVE, FUSE, and HST are utilized to support the analysis. Results. No metals could be identified in LB1919. All observations are compatible with a pure hydrogen atmosphere. This is in stark contrast to the vast majority of hot DA white dwarfs that exhibit light and heavy metals and to the stratified models that predict significant metal abundances in the atmosphere. For GD246 we find that neither stratified nor homogeneous models can fit the Chandra spectrum. The Chandra spectrum of PG1520+525 constrains the effective temperature to T(sub eff) = 150 000 +/- 10 000 K. Therefore, this nonpulsating star together with the pulsating prototype of the GWVir class (PG1159-035) defines the location of the blue edge of the GWVir instability region. The result is in accordance with predictions from nonadiabatic stellar pulsation models. Such models are therefore reliable tools to investigate the interior structure of GW Vir variables. Conclusions. Our soft X-ray study reveals that the understanding of metal abundances in hot DA white dwarf atmospheres is still incomplete. On the other hand, model atmospheres of hydrogen-deficient PG1159-type stars are reliable and reproduce well the observed spectra from soft X-ray to optical wavelengths.

Adamczak, J.↗

Multi-EVA communications system analysis

A communications concept is analyzed to establish requirements of a confident candidate system for space shuttle. Conceptual baseline configurations, EVA's-to-spacecraft via PCM/FDM and spacecraft-to-EVA via PAM/FM, and respective functional performance requirements are discussed. The baseline system is analyzed to determine link characteristics, EMI levels at various frequency bands, and determination of desirable spectrum. Selected L- and S-Band links are analyzed to ascertain signal design parameters. A trade-off is performed, which establishes L-Band frequency as the best compromise. The results of the analysis along with the reliability/safety aspects and physical characteristics of the candidate system, indicate that the initial baseline concept meets functional requirements, but is poor from standpoint of overall space shuttle program cost.

Source record↗

Application of Derivative Spectrometry to the Analysis of Trace Gases

A derivative spectrometer is sensitive to changes in spectral intensity over narrow wavelength internal. Specifically, a second derivative spectrometer senses the curvature of the incident spectral intensity, providing an output voltage signal proportional to the second derivative of intensity with respect to wavelength. When such an instrument is combined with multi-pass White cell, a unique trace gas analyzer results. The analyzer, operating within the middle ultraviolet spectral region, provides a highly amplified derivative spectrum of any molecular narrow band absorption which is used for trace gas identification. The intensity of any peak within a spectrum is proportional to the trace gas concentration. Such an analyzer, utilizing a 20 meter pathlength White cell, is presently being used to automatically monitor ambient air for SO2, NO, NO2, and O3 with minimum detectable concentration limits in the part per billion range.

Hager, Robert N.↗

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗

On muon energy spectrum in muon groups underground

A method is described which was used to measure muon energy spectrum characteristics in muon groups underground using mu-e decays recording. The Baksan Telescope's experimental data on mu-e decays intensity in muon groups of various multiplicities are analyzed. The experimental data indicating very flat spectrum does not however represent the total spectrum in muon groups. Obviously the muon energy spectrum depends strongly on a distance from the group axis. The core attraction effect makes a significant distortion, making the spectrum flatter. After taking this into account and making corrections for this effect the integral total spectrum index in groups has a very small depencence on muon multiplicity and agrees well with expected one: beta=beta (sub expected) = 1.75.

Bakatanov, V. N.↗

How to unveil a T Tauri star

A method for separating the 'veiling' continuum often present in T Tauri stars from the underlying photospheric spectrum is described. Echelle observations from 5100 to 6800 A of the partially veiled T Tauri star BP Tau were analyzed to determine the shape of the veiling spectrum. The residuals of the fit indicate the deviation of the veiling spectrum from a simple continuum and identify the location and strength of any emission-line components. It is shown, by means of goodness-of-fit tests, that the spectrum of BP Tau can be decomposed into a normal stellar spectrum plus a smooth veiling continuum with only a few emission lines superposed. The continuum dominates the veiling spectrum in this spectral region; the veiling does not arise from numerous deep photospheric absorption lines that are filled in by weak emission.

Hartigan, Patrick↗

The Influence of Radiation on Ice Crystal Spectrum in the Upper Troposphere

This theoretical study is carried out to investigate the effect of radiation on ice crystal spectrum in the upper troposphere. First, an explicit expression is obtained for the ice crystal growth rate that takes account of radiative and kinetic effects. Second, the expression is used to quantitatively analyze how radiation broadens the ice crystal spectrum and then reveal a new precipitation mechanism in the upper troposphere and the stratosphere. Third, the radiative effect is used to explain the subvisual clouds near the tropopause.

Zeng, Xiping↗

Chirally selective, intramolecular interaction observed in an aminoacyl adenylate anhydride

The interaction between amino acids and nucleotide bases is studied. The proton NMR spectrum of N-acetylphenylalanyl-AMP-anhydride is analyzed H8 and H2 signals, two upfield signals of equal size, and five phenylalanine ring proton signals are observed in the spectrum; the upfield movement of the proton and the racemization of the N-acetyl L-phenylalanine material are examined. The differences in the position of the signals due to the diastereoisomers are investigated. The separation of the D and L amino acyl adenylates using HPLC is described. H-1 NMR spectra of the isomers are examined in order to determine which isomer displays the strongest interaction between the phenyl ring and the adenine ring. The spectra reveal that the L isomer shows the highest upfield change of both H8 and H2 signals. It is noted that the phenyl ring lies over C2 of the adenine ring with the phenyl meta and para protons extended past the adenine ring and the phenyl ortho protons.

Lacey, J. C., Jr.↗

New Approach to Ultrasonic Spectroscopy Applied to Flywheel Rotors

Flywheel energy storage devices comprising multilayered composite rotor systems are being studied extensively for use in the International Space Station. A flywheel system includes the components necessary to store and discharge energy in a rotating mass. The rotor is the complete rotating assembly portion of the flywheel, which is composed primarily of a metallic hub and a composite rim. The rim may contain several concentric composite rings. This article summarizes current ultrasonic spectroscopy research of such composite rings and rims and a flat coupon, which was manufactured to mimic the manufacturing of the rings. Ultrasonic spectroscopy is a nondestructive evaluation (NDE) method for material characterization and defect detection. In the past, a wide bandwidth frequency spectrum created from a narrow ultrasonic signal was analyzed for amplitude and frequency changes. Tucker developed and patented a new approach to ultrasonic spectroscopy. The ultrasonic system employs a continuous swept-sine waveform and performs a fast Fourier transform on the frequency spectrum to create the spectrum resonance spacing domain, or fundamental resonant frequency. Ultrasonic responses from composite flywheel components were analyzed at Glenn to assess this NDE technique for the quality assurance of flywheel applications.

Harmon, Laura M.↗

Affine Transformations to Enable Machine Learning for Semi-Quantitative EDS Analysis

Energy Dispersive X-ray Spectroscopy (EDS) is an essential technique for determining elemental concentrations and distributions within microstructures, critical for materials discovery, optimization, and qualification. However, most published EDS data is qualitative because current quantitative EDS analysis methods require extensive calibration and post-processing, limiting their practicality and widespread adoption. This work seeks to establish a framework for accelerated EDS characterization and spectrum analysis that can leverage ML to analyze correlations between various elemental compositions and resulting EDS spectra. The complex physics and data result in a high-dimensional problem that grows exponentially with the number of elements in the system and the complexity of the spectrum analysis. ML provides a way to compute and optimize the results of this highly dimensional problem in a flexible way to tailor it to the user’s specific needs and material system. However, the framework emphasizes transparency through a strictly mathematical affine transformation, so the analysis remains understandable and reviewable to facilitate adoption by the scientific community. While currently implemented methods are simplistic and unvalidated, further development and demonstration of this framework could enable high-throughput, accurate, and accessible EDS characterization.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Affine Transformations to Correlate Experimental and Simulated EDS Spectra for Multi-Element Systems

Energy Dispersive X-ray Spectroscopy (EDS) is an essential technique for determining elemental concentrations and distributions within microstructures, critical for materials discovery, optimization, and qualification. However, most published EDS data is qualitative because current quantitative EDS analysis methods require extensive calibration and post-processing, limiting their practicality and widespread adoption. This work seeks to establish a framework for accelerated EDS characterization and spectrum analysis that can leverage ML to analyze correlations between various elemental compositions and resulting EDS spectra. The complex physics and data result in a high-dimensional problem that grows exponentially with the number of elements in the system and the complexity of the spectrum analysis. ML provides a way to compute and optimize the results of this highly dimensional problem in a flexible way to tailor it to the user’s specific needs and material system. However, the framework emphasizes transparency through a strictly mathematical affine transformation, so the analysis remains understandable and reviewable to facilitate adoption by the scientific community. While currently implemented methods are simplistic and unvalidated, further development and demonstration of this framework could enable high-throughput, accurate, and accessible EDS characterization.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗