Search NASA⌕ Search

SEARCH · Search NASA

Results for “stacking modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Performance of layer wound epoxy-impregnated coils made from a multifilamentary cable of exfoliated YBCO

The performance and reliability of magnets made from second generation (2G), exfoliated, YBCO conductors are highly improved by use of narrow, stacked, multifilamentary cable instead of a single wide tape. This work reports on tests of five mini-coils wound from 2.4 mm wide ExoCable™, which is comprised of eight, stacked, exfoliated, YBCO filaments. The filaments are coupled electrically through a re-flow process, which results in enhanced electrical connectivity between the adjacent layers. The coils were tested at 77 K (up to 500 A) in liquid nitrogen and at 22 K (up to 700 A) in a conduction-cooled mode. The cable carries 500 A critical current at 77 K. A six-layer coil wound from 10.5 m of the cable, the largest coil created in the study, demonstrates a critical current of 280 A at 77 K at 0.4 T magnetic field on the winding. The coils were fully impregnated with Stycast 1266 and Henkel W19 low-viscosity epoxies. Repeated thermal cycling, to 77 and 22 K, does not degrade the coil's performance. The cable AC loss and the coil winding magnetization are compared with the traditional 2G wide tape pancake geometry at 77 K. We observe a five times reduction of the winding magnetization when the 12 mm tape is replaced by a 2.4 mm cable, which is explained by the smaller magnetic moment of the cable winding. The field hysteresis profiles recorded at 22 and 77 K are presented to demonstrate the effect of the operation temperature on the winding magnetization. A finite element analysis of the winding magnetization shows a good agreement between the experimentally measured trapped field value, and the critical state model prediction. Finally, we discuss the stability of an ExoCable™ coil in a conduction-cooled operation.

2G cables↗

Compression fatigue behavior of composites in the presence of delaminations

Three different stacking sequences of a 64-ply layup were tested in an experimental investigation of the effect of idealized imbedded delaminations on the compression fatigue behavior of quasi-isotropic T300/5208 graphite-epoxy laminates. Postfailure examination of specimen cross sections revealed the absence of any fiber microbuckling, suggesting that the predominant failure mode was the propagation of imbedded delaminations in the tab region. One- and two-dimensional delaminations, respectively located across the entire width below the surface ply and buried one or four plies below the surface, were considered. A novel procedure employing minute, laser-drilled holes was successfully used in extending the application of diidobutane-enhaced radiography to buried delaminations.

Ramkumar, R. L.↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Assessment of Hydrodynamic Loads on Rockeries for River Bank Protection

Colorado experienced an extreme flooding event in September of 2013 that ravaged canyon roadways southeast of Estes Park, CO. Central Federal Lands was asked to rebuild SH 34 and CO 43 after the floods. To minimize river encroachments in narrow canyons, roadway fill embankments must be over steepened. Using a rockery to stabilize the roadway embankment rather than traditional vertical, concrete structures was the solution. However, no analytical techniques were available for evaluating the hydraulic stability of such structures. Argonne National Laboratory was employed to estimate the hydrodynamic forces by using advanced, computational fluid dynamics (CFD). An investigation was conducted on a section of a model rockery comprised of large boulders exposed to a variety of hydraulic flow conditions. A repeatable geometric section of a typical rockery structure was modeled and used to create boundaries for the CFD model. The test case matrix covers computer simulations of various rockery and channel geometries. The geometrical parameters taken into account are: rockery height, outside face batter angle of the rockery, rockery base width, river bed width, and the hydraulic parameters are: flow depth, flow velocity, and hydraulic angle of attack. Two failure mechanisms of rockery structures, sliding and overturning, are considered. The existing design equations for both modes are modified by addition of hydrodynamic force terms. The new terms were calculated for a parametric set of geometry and condition variation using the CFD model. Moreover, formulas for dimensionless hydraulic force coefficients are proposed that can be used in the design of new rockeries or in evaluation of existing dry-stack rockeries in river environments.

42 ENGINEERING↗

A model for compression after impact strength evaluation

One key property commonly used for evaluating composite material performance is compression after impact strength (CAI). Standarad CAI tests typically use a specific laminate stacking sequence, coupon geometry, and impact level. In order to understand what material factors affect CAI, evaluation of test results should include more than comparisons of the measured strength for different materials. This study considers the effects of characteristic impact damage state, specimen geometry, material toughness, ply group thickness, undamaged strength, and failure mode. The results of parametric studies, using an analysis model developed to predict CAI, are discussed. Experimental results used to verify the model are also presented. Finally, recommended pre- and post-test CAI evaluation schemes which help link material behavior to structural performance are summarized.

Ilcewicz, Larry B.↗

Heel and toe driving on fuel cell vehicle

A system and method for providing nearly instantaneous power in a fuel cell vehicle. The method includes monitoring the brake pedal angle and the accelerator pedal angle of the vehicle, and if the vehicle driver is pressing both the brake pedal and the accelerator pedal at the same time and the vehicle is in a drive gear, activating a heel and toe mode. When the heel and toe mode is activated, the speed of a cathode compressor is increased to a predetermined speed set-point, which is higher than the normal compressor speed for the pedal position. Thus, when the vehicle brake is removed, the compressor speed is high enough to provide enough air to the cathode, so that the stack can generate nearly immediate power.

33 ADVANCED PROPULSION SYSTEMS↗

Possible Dynamically Gated Conductance along Heme Wires in Bacterial Multiheme Cytochromes

The staggered cross decaheme configuration of electron transfer co-factors in the outer-membrane cytochrome MtrF may serve as a prototype for conformationally-gated multi-heme electron transport. Derived from the bacterium Shewanella oneidensis, the staggered cross configuration reveals intersecting c-type octaheme and tetraheme “wires” containing thermodynamic “hills” and “valleys”, suggesting that the protein structure may include a dynamical mechanism for conductance and pathway switching depending on enzymatic functional need. Recent molecular simulations have established the pair-wise electronic couplings, redox potentials, and reorganization energies to predict the maximum conductance along the various heme wire pathways by sequential hopping of a single electron (PNAS (2014) 11,611-616). Here, we expand this information with classical molecular and statistical mechanics calculations of large-amplitude protein dynamics in MtrF, to address its potential to modulate pathway conductance, including assessment of the effect of the total charge state. Explicit solvent molecular dynamics simulations of fully oxidized and fully reduced MtrF employing ten independent 50-ns simulations at 300 K and 1 atm showed that reduced MtrF is more expanded and explores more conformational space than oxidized MtrF, and that heme reduction leads to increased heme solvent exposure. The slowest mode of collective decaheme motion is 90% similar between the oxidized and reduced states, and consists primarily of inter-heme separation with minor rotational contributions. The frequency of this motion is 1.7×107 s 1 for fully-oxidized and fully-reduced MtrF, respectively, slower than the downhill electron transfer rates between stacked heme pairs at the octaheme termini and faster than the electron transfer rates between parallel hemes in the tetraheme chain. This implies that MtrF uses slow conformational fluctuations to modulate electron flow along the octaheme pathway, apparently for the purpose of increasing the residence time of electrons on lowest potential hemes 4 and 9. This apparent gating mechanism should increase the success rate of electron transfer from MtrF to low potential environmental acceptors via these two solvent-exposed hemes.

c-type cytochromes, MtrF, Shewanella oneidensis, h↗

Gate-tunable modulation of the optical properties of multilayer graphene by the reversible intercalation of ionic liquid anions

We demonstrate a substantial modulation of the optical properties of multilayer graphene (~100 layers) using a simple device consisting of a multilayer graphene/polymer electrolyte membrane/gold film stack. Applying a voltage of 3–4 V drives the intercalation of anion [TFSI] - [ion liquid diethylmethyl(2-methoxyethyl)ammonium bis(trifluoromethylsulfonyl)imide [DEME][TFSI]] resulting in the reversible modulation of the properties of this optically dense material. Upon intercalation, we observe an abrupt shift of 35 cm -1 in the G band Raman mode, an abrupt increase in FTIR reflectance over the wavelength range from 1.67 to 5 $μ$m (2000–6000 cm -1 ), and an abrupt increase in luminescent background observed in the Raman spectra of graphene. Furthermore, all of these abrupt changes in the optical properties of this material arise from the intercalation of the TFSI - ion and the associated change in the free carrier density (Δ$n$ = 10 20 cm -3 ). Suppression of the 2D band Raman mode observed around 3 V corresponds to Pauli blocking of the double resonance Raman process and indicates a modulation of the Fermi energy of Δ$E$ F = 1.1 eV.

42 ENGINEERING↗

Investigating high-energy proton-induced reactions on spherical nuclei: Implications for the preequilibrium exciton model

A number of accelerator-based isotope production facilities utilize $100-200$ MeV proton beams due to the high production rates enabled by high-intensity beam capabilities and the greater diversity of isotope production brought on by the long range of high-energy protons. However, nuclear reaction modeling at these energies can be challenging because of the interplay between different reaction modes and a lack of existing guiding cross section data. A Tri-lab collaboration has been formed between the Lawrence Berkeley, Los Alamos, and Brookhaven National Laboratories to address these complexities by characterizing charged-particle nuclear reactions relevant to the production of established and novel radioisotopes. In the inaugural collaboration experiments, stacked-targets of niobium foils were irradiated at the Brookhaven Linac Isotope Producer ($E_p=200$ MeV) and the Los Alamos Isotope Production Facility ($E_p=100$ MeV) to measure $^{93}$Nb(p,x) cross sections between $50-200$ MeV. The results were compared with literature data as well as the default calculations of the nuclear model codes TALYS, CoH, EMPIRE, and ALICE. The default code predictions largely failed to reproduce the measurements. Therefore, we developed a standardized procedure, which determines the reaction model parameters that best reproduce the most prominent reaction channels in a physically justifiable manner. Overall, the primary focus of the procedure was to determine the best parameterization for the pre-equilibrium two-component exciton model. This modeling study revealed a trend towards a relative decrease for internal transition rates at intermediate proton energies ($E_p=20-60$ MeV) in the current exciton model as compared to the default values. The results of this work are instrumental for the planning, execution, and analysis essential to isotope production.

43 PARTICLE ACCELERATORS↗

Low loss fiber-coupled volumetric interconnects fabricated via direct laser writing

Photonic integrated circuits (PICs) are vital for high-speed data transmission. However, optical routing is limited in PICs composed of only one or a few stacked planes. Further, coupling losses must be low in deployed systems. Previously, we developed the subsurface controllable refractive index via beam exposure (SCRIBE) technique to write accurate 3D gradient refractive index (GRIN) profiles within a mesoporous silica scaffold. Here, we apply SCRIBE to fabricate low loss, broadband, polarization insensitive, fiber-coupled, single-mode volumetric interconnects that include waveguides traversing arbitrary 3D paths. By seamlessly integrating mode-matching subsurface lenses and GRIN waveguide tapers, calibrating for positional writing errors, implementing multipass exposure, automating alignment, and switching to antireflection coated fibers, we reduced the insertion loss for a fiber-PIC-fiber interconnect from 50 to 2.14 dB, or 1.47 dB, excluding the fiber array’s loss. Further, we establish an upper bound of 0.45 dB loss per coupler. We report quality factors of 27,000 and 77,000 and bending losses of 6 and 3 dB/cm for 15 and 30 µm radii microrings, respectively. We also demonstrate Bézier escalators, polarization-rotating and polarization-splitting interconnects, and a seven-channel 25 µm pitch volumetric interconnect. The SCRIBE platform presents a clear path toward realizing 3D PICs with unique functionality.

Optics↗

Preliminary investigations for the option to use fast uniform scanning with compensators on a gantry designed for IMPT

Purpose: In this experimental study, the authors explored the possibility to deliver the dose for proton therapy with fast uniform scanning on a gantry primarily designed for the delivery of conformal beam scanning and IMPT. The uniform scanning submode has been realized without equipment modifications by using the same small pencil beam used for conformal scanning, resulting in reduced realization costs. Uniform scanning has recently been adopted in a few proton therapy centers, as a basic beam delivery solution, and as an alternative to the use of scattering foils. The option to use such a mode to mimic scattering on a full-fledged scanning gantry could be of interest for treating some specific indications and as a possible solution for treating moving targets. Methods: Uniform iso-energy dose layers were painted by fast magnetic scanning alternated with fast energy changes with the gantry beam line. The layers were stacked and repainted appropriately to produce homogeneous three-dimensional dose distributions. A collimator/compensator was used to adjust the dose to coincide laterally/distally with the target volume. In addition, they applied volumetric repainting, since they are confident that this will further mitigate the effects of organ motion as compared with the presently used clinical scanning solutions. With the approach presented in this paper, they can profit from the higher flexibility of the scanning system to obtain additional advantages. For instance the shape of the energy layers can be adjusted to the projected target shape in order to reduce treatment time and neutrons produced in the collimator. The shape of the proximal layers can be shrunk, according to the cross section of the target at the corresponding range. This provides variable range modulation (proximal conformity) while standard scattering only provides fixed range modulation with unnecessary 100% dose proximal to the target. The field-specific hardware for a spherical target volume was mounted on the Gantry 2 nozzle. One field with proximal field size shrinking and one without, each of 1 Gy, were delivered. The dose distributions at different depths were recorded as CCD images of a scintillating screen. Results: The time to scan the volume once was about 4 s and the total delivery time was approximately 30 s. For the field with proximal conformity, dose sparing of up to 25% was measured in the region proximal to the target. A repainting capability of 48 times was achieved on the most distal layer. The proximal layers were repainted more due to the contribution of the plateau dose from the deeper layers. Conclusions: The flexibility of a fast scanning gantry with very fast energy changes can easily provide beam delivery by uniform layer stacking with a significant degree of volumetric repainting and with the benefit of a dose reduction proximal to the target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual thermal and moisture influences on the free-edge delamination of laminated composites

A simple delamination analysis method is developed. It is based on a shear-type deformation theory and includes hygrothermal effects. The method is applied to mixed-mode edge delamination specimens made of T300/5208 graphite/epoxy. It is found that residual thermal influences were alleviated when moisture stresses were included. Thermal effects on the interlaminar shear stress and total energy release rate were totally alleviated for the same specific moisture content. Moreover, this value of moisture content was not significantly affected by the stacking sequence for the laminates considered.

Armanios, Erian A.↗

The Dynamics of Rapidly Emplaced Terrestrial Lava Flows and Implications for Planetary Volcanism

The Kaupulehu 1800-1801 lava flow of Hualalai volcano and the 1823 Keaiwa flow from the Great Crack of the Kilauea southwest rift zone had certain unusual and possibly unique properties for terrestrial basaltic lava flows. Both flows apparently had very low viscosities, high effusion rates, and uncommonly rapid rates of advance. Ultramafic xenolith nodules in the 1801 flow form stacks of cobbles with lava rinds of only millimeter thicknesses. The velocity of the lava stream in the 1801 flow was extremely high, at least 10 m/s (more than 40 km/h). Observations and geological evidence suggest similarly high velocities for the 1823 flow. The unusual eruption conditions that produced these lava flows suggest a floodlike mode of emplacement unlike that of most other present-day flows. Although considerable effort has gone into understanding the viscous fluid dynamics and thermal processes that often occur in basaltic flows, the unusual conditions prevalent for the Kaupulehu and Keaiwa flows necessitate different modeling considerations. We propose an elementary flood model for this type of lava emplacement and show that it produces consistent agreement with the overall dimensions of the flow, channel sizes, and other supporting field evidence. The reconstructed dynamics of these rapidly emplaced terrestrial lava flows provide significant insights about the nature of these eruptions and their analogs in planetary volcanism.

Baloga, Stephen↗

Ionospheric Signature of Surface Mine Blasts from Global Positioning System Measurements

Sources such as atmospheric or buried explosions and shallow earthquakes are known to produce infrasonic pressure waves in the atmosphere. Because of the coupling between neutral particles and electrons at ionospheric altitudes, these acoustic and gravity waves induce variations of the ionospheric electron density. The Global Positioning System (GPS) provides a way of directly measuring the total electron content in the ionosphere and, therefore, of detecting such perturbations in the upper atmosphere. In July and August 1996, three large surface mine blasts (1.5 Kt each) were detonated at the Black Thunder coal mine in eastern Wyoming. As part of a seismic and acoustic monitoring- experiment, we deployed five dual-frequency GPS receivers at distances ranging from 50 to 200 km from the mine and were able to detect the ionospheric perturbation caused by the blasts. The perturbation starts 10 to 15 min after the blast, lasts for about 30 min, and propagates with an apparent horizontal velocity of 1200 meters per second. Its amplitude reaches 3 x 10 (exp 14) el per square meters in the 7-3 min period band, a value close to the ionospheric perturbation caused by the M = 6.7 Northridge earthquake. The small signal-to-noise ratio of the perturbation can be improved by slant-stacking the electron content time-series recorded by the different GPS receivers taking into account the horizontal propagation of the perturbation. The energy of the perturbation is concentrated in the 200 to 300 second period band, a result consistent with previous observations and numerical model predictions. The 300 second band probably corresponds to gravity modes and shorter periods to acoustic modes, respectively. Using a 1-D stratified velocity model of the atmosphere we show that linear acoustic ray tracing fits arrival times at all GPS receivers. We interpret the perturbation as a direct acoustic wave caused by the explosion itself. This study shows that even relatively small subsurface events can produce ionospheric perturbations that are above the detection threshold of the GPS technique. By sensing derivative signals, which can be detected over a relatively broad region, it appears that GPS might be particularly useful for source characterization within the first acoustic quiet zone where infrasound would probably be ineffective. This suggests that dual-frequency GPS monitoring could contribute to Comprehensive Nuclear Test Ban Treaty verification.

Calais, Eric↗

A Comparison of Quasi-Static Indentation Testing to Low Velocity Impact Testing

The need for a static test method for modeling low-velocity foreign object impact events to composites would prove to be very beneficial to researchers since much more data can be obtained from a static test than from an impact test. In order to examine if this is feasible, a series of static indentation and low velocity impact tests were carried out and compared. Square specimens of many sizes and thickness were utilized to cover the array of types of low velocity impact events. Laminates with a n/4 stacking sequence were employed since this is by the most common type of engineering laminate. Three distinct flexural rigidities under two different boundary conditions were tested in order to obtain damage due to large deflections, contact stresses and both to examine if the static indentation-impact comparisons are valid under the spectrum of damage modes that can be experienced. Comparisons between static indentation and low velocity impact tests were based on the maximum applied transverse load. The dependent parameters examined included dent depth, back surface crack length, delamination area and to a limited extent, load-deflection behavior. Results showed that no distinct differences could be seen between the static indentation tests and the low velocity impact tests, indicating that static indentation can be used to represent a low velocity impact event.

Nettles, Alan T.↗

Feasibility Study of SDAS Instrumentation's Ability to Identify Mobile Launcher (ML)/Crawler-Transporter (CT) Modes During Rollout Operations

The Space Launch System (SLS) and its Mobile Launcher (ML) will be transported to the launch pad via the Crawler-Transporter (CT) system. Rollout (i.e., transportation) loads produce structural loads on the integrated SLS/Orion Multi-Purpose Crew Vehicle (MPCV) launch vehicle which are of a concern with respect to fatigue. As part of the risk reduction process and in addition to the modal building block test approach that has been adopted by the SLS Program, acceleration data will be obtained during rollout for use in modal parameter estimation. There are several occurrences where the ML/CT will be transported either into the Vertical Assembly Building (VAB) or to the launch pad and back without the SLS stack as part of the Kennedy Space Center (KSC) Exploration Ground Systems (EGS) Integrated Test and Checkout (ITCO). NASA KSC EGS has instrumentation installed on both the ML and CT to record data during rollout, at the launch pad, and during liftoff. The EGS instrumentation on the ML, which includes accelerometers, is referred to as the Sensor Data Acquisition System (SDAS). The EGS instrumentation on the CT, which also includes accelerometers, is referred to as the CT Data Acquisition System (CTDAS). The forces and accelerations applied to the ML and CT during a rollout event will be higher than any of the planned building block modal tests. This can be very beneficial in helping identify nonlinear behavior in the structure. Developing modal parameters from the same test hardware in multiple boundary conditions and under multiple levels of excitation is a key step in developing a well correlated FEM. The purpose of this study was three fold. First, determine the target modes of the ML/CT in its rollout configuration. Second, determine if the test degrees of freedom (DOF) corresponding to the layout of the SDAS/CTDAS accelerometers (i.e. position and orientation) is sufficient to identify the target modes. Third, determine if the Generic Rollout Forcing Functions (GRFF's) is sufficient for identifying the ML/CT target modes accounting for variations in CT speed, modal damping, and sensor/ambient background noise levels. The finding from the first part of this study identified 28 target modes of the ML/CT rollout configuration based upon Modal Effective Mass Fractions (MEFF) and engineering judgement. The finding from the second part of this study showed that the SDAS/CTDAS accelerometers (i.e. position and orientation) are able to identify a sufficient number of the target modes to support model correlation of the ML/CT FEM. The finding from the third part of this study confirms the GRFFs sufficiently excite the ML/CT such that varying quantities of the defined target modes should be able to be extracted when utilizing an Experimental Modal Analysis (EMA) Multi-Input Multi-Output (MIMO) analysis approach. An EMA analysis approach was used because Operational Modal Analysis (OMA) tools were not available and the GRFFs were sufficiently uncorrelated. Two key findings from this third part of the study are that the CT speed does not show a significant impact on the ability to extract the modal parameters and that keeping the ambient background noise observed at each accelerometer location at or below 30 µgrms is essential to the success of this approach.

Winkel, James P.↗

Cross sections and production yields of 117m Sn and other radionuclides generated in natural and enriched antimony with protons up to 145 MeV

Cross sections of a prospective medical radionuclide 117m Sn along wit h 113 Sn, 120m,122 Sb, 111,114m In and 118,119m,119g,121m,121g,123m Te generated in natural and enriched antimony targets by protons in a wide energy range up to 145 MeV were determined. A stacked-foil technique followed by gas chemical separation and γ-ray spectrometry were used. The obtained data were compared with experimental values reported in literature and with theoretical computations by ALICE, TALYS and Cascade-Evaporation-Fission codes. Finally, production yields of 117m Sn and the main impurity 113 Sn were estimated for different irradiation modes.

07 ISOTOPE AND RADIATION SOURCES↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗