At least 397 records · Page 22

TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

60 APPLIED LIFE SCIENCES↗

Mars Sample Handling Protocol Workshop Series: Workshop 2

Numerous NASA reports and studies have identified Planetary Protection (PP) as an important part of any Mars sample return mission. The mission architecture, hardware, on-board experiments, and related activities must be designed in ways that prevent both forward- and back-contamination and also ensure maximal return of scientific information. A key element of any PP effort for sample return missions is the development of guidelines for containment and analysis of returned sample(s). As part of that effort, NASA and the Space Studies Board (SSB) of the National Research Council (NRC) have each assembled experts from a wide range of scientific fields to identify and discuss issues pertinent to sample return. In 1997, the SSB released its report on recommendations for handling and testing of returned Mars samples. In particular, the NRC recommended that: a) samples returned from Mars by spacecraft should be contained and treated as potentially hazardous until proven otherwise, and b) rigorous physical, chemical, and biological analyses [should] confirm that there is no indication of the presence of any exogenous biological entity. Also in 1997, a Mars Sample Quarantine Protocol workshop was convened at NASA Ames Research Center to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent 'uncontrolled release' of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. In 1999, a study by NASA's Mars Sample Handling and Requirements Panel (MSHARP) addressed three other specific areas in anticipation of returning samples from Mars: 1) sample collection and transport back to Earth; 2) certification of the samples as non-hazardous; and 3) sample receiving, curation, and distribution. To further refine the requirements for sample hazard testing and the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened an additional series of workshops beginning in March 2000. The overall objective of these workshops was to develop comprehensive protocols to assess whether the returned materials contain any biological hazards, and to safeguard the purity of the samples from possible terrestrial contamination. This document is the report of the second Workshop in the Series. The information herein will ultimately be integrated into a final document reporting the proceedings of the entire Workshop Series along with additional information and recommendations.

Rummel, John D.↗

Quantum algorithmic measurement

There has been recent promising experimental and theoretical evidence that quantum computational tools might enhance the precision and efficiency of physical experiments. However, a systematic treatment and comprehensive framework are missing. Here we initiate the systematic study of experimental quantum physics from the perspective of computational complexity. To this end, we define the framework of quantum algorithmic measurements (QUALMs), a hybrid of black box quantum algorithms and interactive protocols. We use the QUALM framework to study two important experimental problems in quantum many-body physics: determining whether a system’s Hamiltonian is time-independent or time-dependent, and determining the symmetry class of the dynamics of the system. We study abstractions of these problems and show for both cases that if the experimentalist can use her experimental samples coherently (in both space and time), a provable exponential speedup is achieved compared to the standard situation in which each experimental sample is accessed separately. Our work suggests that quantum computers can provide a new type of exponential advantage: exponential savings in resources in quantum experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗

Effects of muscle atrophy on motor control

As a biological tissue, muscle adapts to the demands of usage. One traditional way of assessing the extent of this adaptation has been to examine the effects of an altered-activity protocol on the physiological properties of muscles. However, in order to accurately interpret the changes associated with an activity pattern, it is necessary to employ an appropriate control model. A substantial literature exists which reports altered-use effects by comparing experimental observations with those from animals raised in small laboratory cages. Some evidence suggests that small-cage-reared animals actually represent a model of reduced use. For example, laboratory animals subjected to limited physical activity have shown resistance to insulin-induced glucose uptake which can be altered by exercise training. This project concerned itself with the basic mechanisms underlying muscle atrophy. Specifically, the project addressed the issue of the appropriateness of rats raised in conventional-sized cages as experimental models to examine this phenomenon. The project hypothesis was that rats raised in small cages are inappropriate models for the study of muscle atrophy. The experimental protocol involved: 1) raising two populations of rats, one group in conventional (small)-sized cages and the other group in a much larger (133x) cage, from weanling age (21 days) through to young adulthood (125 days); 2) comparison of size- and force-related characteristics of selected test muscles in an acute terminal paradigm.

Stuart, D. G.↗

13 C-Isotope-Assisted Assessment of Metabolic Quenching During Sample Collection from Suspension Cell Cultures

Metabolomics and fluxomics are core approaches to directly profile and interrogate cellular metabolism in response to various genetic or environmental perturbations. In order to accurately measure the abundance and isotope enrichment of intracellular metabolites, cell culture samples must be rapidly harvested and cold-quenched to preserve the in vivo metabolic state of the cells at the time of sample collection. When dealing with suspension cultures, this process is complicated by the need to separate the liquid culture media from cellular biomass prior to metabolite extraction. Here, we examine the efficacy of several commonly used metabolic quenching methods, using the model cyanobacterium Synechocystis sp. PCC 6803 as an example. Multiple 13 C-labeled compounds, including 13 C-bicarbonate, 13 C-glucose and 13 C-glutamine, were used as tracers during the sample collection and cold-quenching process to assess the extent of metabolic turnover after cells were harvested from culture flasks. We show that the combination of rapid filtration followed by 100% cold (–80°C) methanol quenching exhibits the highest quenching efficiency, while mixing cell samples with a partially frozen 30% methanol slurry (–24°C) followed by centrifugation is slightly less effective at quenching metabolism but enables less laborious sample processing. By contrast, rapidly mixing the cells with a saline ice slurry (~0°C) is less effective as indicated by high isotope-labeling rates after sample harvest, while mixing the cells with 60% cold methanol (–65°C) prior to centrifugation causes significant metabolite loss. Furthermore, this study demonstrates a rigorous, quantitative, and broadly applicable method for assessing the metabolic quenching efficacy of protocols used for sample collection in metabolomics and fluxomics studies.

59 BASIC BIOLOGICAL SCIENCES↗

Improvement of cellulose catabolism in Clostridium cellulolyticum by sporulation abolishment and carbon alleviation

Background Clostridium cellulolyticum can degrade lignocellulosic biomass, and ferment the soluble sugars to produce valuable chemicals such as lactate, acetate, ethanol and hydrogen. However, the cellulose utilization efficiency of C. cellulolyticum still remains very low, impeding its application in consolidated bioprocessing for biofuels production. In this study, two metabolic engineering strategies were exploited to improve cellulose utilization efficiency, including sporulation abolishment and carbon overload alleviation. Results The spo0A gene at locus Ccel_1894, which encodes a master sporulation regulator was inactivated. The spo0A mutant abolished the sporulation ability. In a high concentration of cellulose (50 g/l), the performance of the spo0A mutant increased dramatically in terms of maximum growth, final concentrations of three major metabolic products, and cellulose catabolism. The microarray and gas chromatography mass spectrometry (GC-MS) analyses showed that the valine, leucine and isoleucine biosynthesis pathways were up-regulated in the spo0A mutant. Based on this information, a partial isobutanol producing pathway modified from valine biosynthesis was introduced into C. cellulolyticum strains to further increase cellulose consumption by alleviating excessive carbon load. The introduction of this synthetic pathway to the wild-type strain improved cellulose consumption from 17.6 g/l to 28.7 g/l with a production of 0.42 g/l isobutanol in the 50 g/l cellulose medium. However, the spo0A mutant strain did not appreciably benefit from introduction of this synthetic pathway and the cellulose utilization efficiency did not further increase. A technical highlight in this study was that an in vivo promoter strength evaluation protocol was developed using anaerobic fluorescent protein and flow cytometry for C. cellulolyticum. Conclusions In this study, we inactivated the spo0A gene and introduced a heterologous synthetic pathway to manipulate the stress response to heavy carbon load and accumulation of metabolic products. These findings provide new perspectives to enhance the ability of cellulolytic bacteria to produce biofuels and biocommodities with high efficiency and at low cost directly from lignocellulosic biomass.

cellulose catabolism↗

Determine the Influence of Time Held in “Knockdown” Anesthesia on Survival and Stress of Surgically Implanted Juvenile Salmonids

The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed for the U.S. Army Corp of Engineers Portland District (USACE) to address questions related to survival and performance measures of juvenile salmonids as they pass through the Federal Columbia River Power System (FCRPS). Researchers using JSATS acoustic transmitters (ATs) were tasked with standardizing the surgical implantation procedure to ensure that the stressors of handling and surgery on salmonids were consistent and less likely to cause effects of tagging in survival studies. Researchers questioned whether the exposure time in 'knockdown' anesthesia (or induction) to prepare fish for surgery could influence the survival of study fish (CBSPSC 2011). Currently, fish are held in knockdown anesthesia after they reach Stage 4 anesthesia until the completion of the surgical implantation of a transmitter, varies from 5 to 15 minutes for studies conducted in the Columbia Basin. The Columbia Basin Surgical Protocol Steering Committee (CBSPSC ) expressed concern that its currently recommended 10-minute maximum time limit during which fish are held in anesthetic - tricaine methanesulfonate (MS-222, 80 mg L-1 water) - could increase behavioral and physiological costs, and/or decrease survival of outmigrating juvenile salmonids. In addition, the variability in the time fish are held at Stage 4 could affect the data intended for direct comparison of fish within or among survival studies. Under the current recommended protocol, if fish exceed the 10-minute time limit, they are to be released without surgical implantation, thereby increasing the number of fish handled and endangered species 'take' at the bypass systems for FCRPS survival studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of Variable Coded Modulations over a Nonlinear Channel for VCM Protocol Red Book

This presentation provides a summary of the results obtained from a study which evaluates the performance of variable coded modulations specified in the "Variable Coded Modulation Protocol" CCSDS Red Book, over a nonlinear channel that is currently on the CCSDS Blue Book track. The objectives are to perform simulation that identifies the operating signal-to-noise-power ratio required to achieve a codeword error rate of 1e-4 over the specified nonlinear channel for various modulations (i.e. BPSK, QPSK, 8-PSK) and LDPC coding schemes, and compare against performance over an ideal additive white Gaussian channel. We select a only subset of operating modes to perform the analysis which are based on a number of mitigation techniques to combat the nonlinear distortions. Specifically, transmitter centroidal pre-distortion, phase post-distortion and receiver mean phase estimation are analyzed in this study.

coding↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

The Effects of Long-Duration Spaceflight on Training Retention and Transfer

Training our crew members for long duration, exploration-class missions will have to maximize long-term retention and transfer of the trained skills. The expected duration of the missions, our inability to predict all the possible tasks the crew will be called upon to perform, and the low training-to-mission time ratio require that the training be maximally effective such that the skills acquired during training will be retained and will be transferrable across a wide range of specific tasks that are different from the particular tasks used during training. However, to be able to design training that can achieve these ambitious goals, we must first understand the ways in which long-duration spaceflight affects training retention and transfer. Current theories of training retention and transfer are largely based on experimental studies conducted at university laboratories using undergraduate students as participants. Furthermore, all such studies have been conducted on Earth. We do not know how well the results of these studies predict the performance of crew members. More specifically, we do not know how well the results of these studies predict the performance of crew members in space and especially during long-duration missions. To address this gap in our knowledge, the current on-going study seeks to test the null hypothesis that performance of university undergraduate students on Earth on training retention and transfer tests do in fact predict accurately the performance of crew members during long-duration spaceflights. To test this hypothesis, the study employs a single 16-month long experimental protocol with 3 different participant groups: undergraduate university students, crew members on the ground, and crew members in space. Results from this study will be presented upon its completion. This poster presents results of study trials of the two tasks used in this study: a data entry task and a mapping task. By researching established training principles, by examining future needs, and by using current practices in spaceflight training as test beds, this research project is mitigating program risks and generating templates and requirements to meet future training needs.

ISS↗

The Effects of Long-Duration Spaceflight on Training Retention and Transfer

Training our crew members for long duration, exploration-class missions will have to maximize long-term retention and transfer of the trained skills. The expected duration of the missions, our inability to predict all the possible tasks the crew will be called upon to perform, and the low training-to-mission time ratio require that the training be maximally effective such that the skills acquired during training will be retained and will be transferrable across a wide range of specific tasks that are different from the particular tasks used during training. However, to be able to design training that can achieve these ambitious goals, we must first understand the ways in which long-duration spaceflight affects training retention and transfer. Current theories of training retention and transfer are largely based on experimental studies conducted at university laboratories using undergraduate students as participants. Furthermore, all such studies have been conducted on Earth. We do not know how well the results of these studies predict the performance of crew members. More specifically, we do not know how well the results of these studies predict the performance of crew members in space and especially during long-duration missions. To address this gap in our knowledge, the current on-going study seeks to test the null hypothesis that performance of university undergraduate students on Earth on training retention and transfer tests do in fact predict accurately the performance of crew members during long-duration spaceflights. To test this hypothesis, the study employs a single 16-month long experimental protocol with 3 different participant groups: undergraduate university students, crew members on the ground, and crew members in space. Results from this study will be presented upon its completion. This poster presents results of study trials of the two tasks used in this study: a data entry task and a mapping task. By researching established training principles, by examining future needs, and by using current practices in spaceflight training as test beds, this research project is mitigating program risks and generating templates and requirements to meet future training needs.

training↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

New Protocol Based on UHPLC-MS/MS for Quantitation of Metabolites in Xylose-Fermenting Yeasts

Xylose fermentation is a bottleneck in second-generation ethanol production. As such, a comprehensive understanding of xylose metabolism in naturally xylose-fermenting yeasts is essential for prospection and construction of recombinant yeast strains. The objective of the current study was to establish a reliable metabolomics protocol for quantification of key metabolites of xylose catabolism pathways in yeast, and to apply this protocol to Spathaspora arborariae. Ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was used to quantify metabolites, and afterwards, sample preparation was optimized to examine yeast intracellular metabolites. S. arborariae was cultivated using xylose as a carbon source under aerobic and oxygen-limited conditions. Ion pair chromatography (IPC) and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) were shown to efficiently quantify 14 and 5 metabolites, respectively, in a more rapid chromatographic protocol than previously described. Thirteen and eleven metabolites were quantified in S. arborariae under aerobic and oxygen-limited conditions, respectively. This targeted metabolomics protocol is shown here to quantify a total of 19 metabolites, including sugars, phosphates, coenzymes, monosaccharides, and alcohols, from xylose catabolism pathways (glycolysis, pentose phosphate pathway, and tricarboxylic acid cycle) in yeast. Furthermore, to our knowledge, this is the first time that intracellular metabolites have been quantified in S. arborariae after xylose consumption. The results indicated that fine control of oxygen levels during fermentation is necessary to optimize ethanol production by S. arborariae. The protocol presented here may be applied to other yeast species and could support yeast genetic engineering to improve second generation ethanol production. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors

This work aimed to study the dosimetric effect of multileaf collimator (MLC) leaf widths in treatment plans for patients receiving volumetric modulated arc therapy (VMAT) for spine stereotactic body radiation therapy (SBRT). Thirteen patients treated with spine SBRT were retrospectively selected for this study. The patients were treated following the protocol of the Radiation Therapy Oncology Group 0631 (RTOG 0631) for spine metastasis. The prescription dose was 16 Gy in 1 fraction to 90% of the target volume (V16 > 90%). The maximum spinal cord dose of 14 Gy and 10% of the spinal cord receiving < 10 Gy (V10) were the acceptable tolerance doses. For the purpose of this study, 2 dual-arc VMAT plans were created for each patient using 3 different MLC leaf widths: 2.5 mm, 4 mm, and 5 mm. The compliance with the RTOG 0631 protocol, conformity index (CI), dose gradient index (DGI), and number of monitor units (MUs) were compared. The average V16Gy of the targets was 91.8 ± 1.2%, 92.2 ± 2.1%, and 91.7 ± 2.3% for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively (p = 0.78). Accordingly, the average CI was 1.45 ± 0.4, 1.47 ± 0.29, and 1.47 ± 0.31 (p = 0.98), respectively. The average DGI was 0.22 ± 0.04, 0.20 ± 0.06, and 0.22 ± 0.05, respectively (p = 0.77). The average maximum dose to the spinal cord was 12.45 ± 1.0 Gy, 12.80 ± 1.0 Gy, and 12.48 ± 1.1 (p = 0.62) and V10% of the spinal cord was 3.6 ± 2.1%, 5.6 ± 2.8%, and 5.5 ± 3.0% (p = 0.11) for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively. Accordingly, the average number of MUs was 4341 ± 500 MU, 5019 ± 834 MU, and 4606 ± 691 MU, respectively (p = 0.053). The use of 2.5-mm, 4-mm, and 5-mm MLCs achieved similar VMAT plan quality as recommended by the RTOG 0631. The dosimetric parameters were also comparable for the 3 MLCs. In general, any of these leaf widths can be used for spine SBRT using VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Dose Reduction in CT Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection by Modifying Scout and Planning Steps

Background and PurposeIn CT fluoroscopy (CTF)-guided cervical transforaminal epidural steroid injection (TFESI), the majority of radiation dose is contributed by the planning CT scan rather than the CTF procedure itself. We replaced the planning helical CT with a spot CTF and accordingly changed the patient posture during scout and planning scans. The aim of this study was to test whether radiation dose reduction would be achieved by this protocol modification while still maintaining technical performance.MethodsOverall, 338 consecutive procedures before (control group: n = 163) and after (study group: n = 175) instituting the above-mentioned protocol modification were analyzed retrospectively, comparing patient characteristics (age, sex, neck diameter, and level injected) and technical performance [technical success rate, dose-length product (DLP), inadvertent contrast flow incidence, number of CTF acquisitions, and procedural time] between the two groups.ResultsAll injections were technically successful at every level from C3–C4 to C7–T1 without serious complications in both groups. The median DLP of the study group (7.92 mGy·cm) was significantly reduced compared to that of the control group (39.05 mGy·cm, P < 0.001). There were no significant differences between the two groups regarding the incidence of inadvertent contrast flow (20.6 vs. 17.2 %, P = 0.426), number of CTF acquisitions (median 5 vs. 4, P = 0.123), and the procedural time (median 6.62 vs. 6.90 min, P = 0.100).ConclusionsWhen conducting CTF-guided cervical TFESIs, a significant radiation dose reduction (median 79.7 % in DLP) can be achieved by modifying scout and planning steps, without compromising the technical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Growth Optimization and Device Integration of Narrow‐Bandgap Graphene Nanoribbons

Abstract The electronic, optical, and magnetic properties of graphene nanoribbons (GNRs) can be engineered by controlling their edge structure and width with atomic precision through bottom‐up fabrication based on molecular precursors. This approach offers a unique platform for all‐carbon electronic devices but requires careful optimization of the growth conditions to match structural requirements for successful device integration, with GNR length being the most critical parameter. In this work, the growth, characterization, and device integration of 5‐atom wide armchair GNRs (5‐AGNRs) are studied, which are expected to have an optimal bandgap as active material in switching devices. 5‐AGNRs are obtained via on‐surface synthesis under ultrahigh vacuum conditions from Br‐ and I‐substituted precursors. It is shown that the use of I‐substituted precursors and the optimization of the initial precursor coverage quintupled the average 5‐AGNR length. This significant length increase allowed the integration of 5‐AGNRs into devices and the realization of the first field‐effect transistor based on narrow bandgap AGNRs that shows switching behavior at room temperature. The study highlights that the optimized growth protocols can successfully bridge between the sub‐nanometer scale, where atomic precision is needed to control the electronic properties, and the scale of tens of nanometers relevant for successful device integration of GNRs.

36 MATERIALS SCIENCE↗