Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Argon/UF6 plasma experiments: UF6 regeneration and product analysis

An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

Roman, W. C.↗

Aerosol optical depth retrievals over the Konza Prairie

The aerosol optical depth over the Konza Prairie, near Manhattan, Kansas, was recorded at various locations by five separate teams. These measurements were made in support of the First ISLSCP Field Experiment (FIFE) and used to correct imagery from a variety of satellite and aircraft sensors for the effects of atmospheric scattering and absorption. The results from one instrument are reported here for 26 days in 1987 and for 7 in 1989. Daily averages span a range of 0.05 to 0.28 in the midvisible wavelengths. In addition, diurnal variations are noted in which the afternoon optical depths are greater than those of the morning by as much as 0.07. A comparison between instruments and processing techniques used to determine these aerosol optical depths is provided. The first comparisons are made using summer 1987 data. Differences of as much as 0.05 (midvisible) are observed. Although these data allow reasonable surface reflectance retrievals, they do not agree to within the performance limits typically associated with these types of instruments. With an accuracy goal of 0.02 a preseason calibration/comparison experiment was conducted at a mountain site prior to the final field campaign in 1989. Good calibration data were obtained, and good agreement (0.01, midvisible) was observed in the retrieved optical depth acquired over the Konza. By comparing data from the surface instruments at different locations, spatial inhomogeneities are determined. Then, data from the airborne tracking sunphotometer allow one to determine variations as a function of altitude. Finally, a technique is proposed for using the in situ data to establish an instrument calibration.

Bruegge, Carol J.↗

Computer Controlled High Vacuum Gas Purification and Analysis Line

Light stable isotope work requires the handling of gasses such a way that does not alter isotopic composition. To do this, there are a large number of analytical and experimental procedures which involve the use of a vacuum line, numerous “egg timers” and a human hand on a valve. Unfortunately, the human hand is inconsistent and inadvertent small, and commonly large, differences in timing can have a measurable effect on outcomes. We have constructed a computer controlled high-vacuum line to be used as an expandable platform for future experimental and analytical procedures. The vacuum line consists of an electropolished 316 stainless steel system of cryogenic u-traps partitioned by pneumatic valves. The code to operate the line has been developed using the LabView platform and will allow for automated timing, consistent valve opening speed and unattended operation of long analytical procedures. The aim of this project is to address a need in the light stable isotope laboratory for a general-purpose vacuum line for handling and manipulation of gasses. When combined with existing instrumentation it allows for a significant expansion of current analytical capabilities. The system allows for better handling of standards, gas conversion techniques and gas sample collection for interlaboratory comparisons. The basic structure of the line, automation hardware and software were chosen and designed to provide a base for future expansion of the system to incorporate new automated analytical techniques as laboratory instrumentation and analytical needs expand.

High vacuum↗

Use of TEMPO as a Proxy for Hyperspectral Geostationary Ocean Color Measurements from the GeoXO OCX Instrument: Harnessing Machine Learning and Principal Component Techniques for Atmospheric and Glint Correction

Retrievals of ocean color from space are important for better understanding the ocean ecosystem. The launch of atmospheric geostationary hyperspectral sensors such as TEMPO, provides a unique opportunity to examine the diurnal variability in ocean ecology. While TEMPO does not have as high spatial resolution or full spectral coverage as planned coastal ocean sensors such as the Geosynchronous Littoral Imaging and Monitoring Radiometer (GLIMR) or GeoXO Ocean Color instrument (OCX), its hourly measurements provide coverage of regions such as Lake Erie and the Gulf of Mexico at spatial scales of approximately 5 km. These data can be useful for testing new algorithms. We will apply our newly developed machine learning based atmospheric correction approach for ocean color retrievals to TEMPO data. Our approach begins by decomposing measured radiances from hyperspectral sensors into spectral features that describe the scattering and absorption of the atmosphere as well as the underlying surface reflectance. The coefficients of the principal components are then used to train a neural network to predict ocean color properties derived from collocated MODIS/VIIRS physically-based retrievals. This machine learning approach does not rely on radiative transfer modeling, and the use of MODIS/VIIRS data for training accounts for possible calibration b in hyperspectral data. Previously, we applied our approach using blue and UV wavelengths with the Ozone Monitoring Instrument (OMI) and TROPOspheric Monitoring Instrument (TROPOMI) to show that it can estimate ocean color properties in less-than-ideal conditions such as lightly to moderately clouded conditions as well as sun glint and thus improve the spatial coverage of ocean color measurements. TEMPO provides an opportunity to improve on this approach since it will provide collocated measurements at green and red wavelengths that were not available from OMI and TROPOMI and are important particularly for coastal waters. Additionally, our technique can be applied early in the mission and has potential to demonstrate the value of near real time ocean color products that are important for monitoring of harmful algae blooms and other oceanic phenomena.

Zachary Fasnacht↗

Large space telescope control moment gyro test program

The underlying theory and design of test instrumentation and computer techniques used to determine the power spectral density (PSD) of the third generation gyro are described in detail. Acceptance test results on the completed instrument are presented as well as composite PSD plots. The measured RMS noise over the frequency band 0.0025 - 10 Hz was 0.012 arc seconds. Results obtained at Martin Company indicate an RMS noise of 0.009 arc seconds (0.05 - 10 Hz). The results obtained showed the TGG performance was close to the proposed LST requirements but that additional development work would be needed to reduce the TGG noise to within more desirable limits.

Salamin, E.↗

Ground-based Measurements of Mesosphere Temperatures by Optical Means

The determination of the rotatinal temperature of the molecular emissions of OH or O2 offers a means of observing from the ground the mesosphere temperature at about 90 km throughout the night. The techniques and optical instrumentation developed to carry out these measurements are described. In comparison with other methods for the observation of this important geophysical quantity the optical technique is inexpensive and readily applicable for automatic operations over a long time period.

Meriweather, J. W., Jr.↗

The Retarding Ion Mass Spectrometer on Dynamics Explorer-A

The thermal component of the magnetospheric plasma plays a key role in magnetosphere-ionosphere coupling processes, acting as a strong influence on ionospheric structure at low altitudes and as a source and modifier of the hotter plasma population at high altitudes. The Retarding Ion Mass Spectrometer (RIMS) instrument on Dynamics Explorer-A is designed to measure this important thermal plasma component. Using a combination of retarding potential analysis and magnetic ion mass spectrometer techniques, the RIMS instrument will measure the bulk plasma parameters of ion density (0.1 to 1,000,000 ions/cu cm), temperature (0-45 eV), and bulk flow (greater than 0.5 km/sec) in the inner plasmasphere and ionosphere, and the specific ion pitch angle and energy spectral characteristics in the outer plasmasphere and plasma trough for a mass range of 1-32 amu. The energy and mass spectral step sequences, as well as the multiplexing of the resultant data, can be tailored to accomplish a variety of thermal ion measurements throughout the inner magnetosphere.

Chappell, C. R.↗

Techniques for avoiding discrimination errors in the dynamic sampling of condensable vapors

In the mass spectrometric sampling of dynamic systems, measurements of the relative concentrations of condensable and noncondensable vapors can be significantly distorted if some subtle, but important, instrumental factors are overlooked. Even with in situ measurements, the condensables are readily lost to the container walls, and the noncondensables can persist within the vacuum chamber and yield a disproportionately high output signal. Where single pulses of vapor are sampled this source of error is avoided by gating either the mass spectrometer ""on'' or the data acquisition instrumentation ""on'' only during the very brief time-window when the initial vapor cloud emanating directly from the vapor source passes through the ionizer. Instrumentation for these techniques is detailed and its effectiveness is demonstrated by comparing gated and nongated spectra obtained from the pulsed-laser vaporization of several materials.

Lincoln, K. A.↗

Active Neutron and Gamma-Ray Instrumentation for In Situ Planetary Science Applications

We describe the development of an instrument capable of detailed in situ bulk geochemical analysis of the surface of planets, moons, asteroids, and comets. This instrument technology uses a pulsed neutron generator to excite the solid materials of a planet and measures the resulting neutron and gamma-ray emission with its detector system. These time-resolved neutron and gamma-ray data provide detailed information about the bulk elemental composition, chemical context, and density distribution of the soil within 50 cm of the surface. While active neutron scattering and neutron-induced gamma-ray techniques have been used extensively for terrestrial nuclear well logging applications, our goal is to apply these techniques to surface instruments for use on any solid solar system body. As described, experiments at NASA Goddard Space Flight Center use a prototype neutron-induced gamma-ray instrument and the resulting data presented show the promise of this technique for becoming a versatile, robust, workhorse technology for planetary science, and exploration of any of the solid bodies in the solar system. The detection of neutrons at the surface also provides useful information about the material. This paper focuses on the data provided by the gamma-ray detector.

Parsons, A.↗

Ionospheric direct measurement techniques

The most important physical parameters of the ionosphere which have been studied extensively over the years are: (1) the temperature, density, chemical composition, and directed motion (wind) of the ionized and neutral gas particles; and (2) the electric and magnetic fields. This review will discuss direct in situ techniques used on sounding rockets and satellites to measure these physical parameters. The techniques reviewed are restricted to those which are applicable to altitudes above about 100 km, where the mean free path is greater than the characteristic dimension of the instruments. Direct in situ instrumentation is defined as an experiment which measures the parameters in the immediate vicinity of the vehicle carrying the instrument; remote sensing techniques will not be discussed here.

Bauer, S. J.↗

Instrument Science Experiments on the SNOOPI P-Band Reflectometry Mission

SigNals Of Opportunity: P-band Investigation (SNOOPI) will be the first in-space validation of P-band (240–380 MHz) SoOp techniques and a prototype science instrument. These techniques have the potential to enable remote sensing of root-zone soil moisture (RZSM) and snow water equivalent (SWE). SNOOPI technology validation goals will be met by targeting observations within 9 km of the SMAP calibration/validation sites in the continental United States. A second priority is collection of continuous phase data over snow-covered regions. These goals are evaluated under constraints of a limited data budget and mission lifetime, with a launch readiness in August 2022. This presentation will review the instrument science plans aimed at achieving the validation objectives defined for the mission. Mission planning and data processing approaches are described.

Soil Moisture↗

Phase shift errors in the theory and practice of surface intensity measurements

The surface acoustical intensity method (sometimes known as the microphone-accelerometer cross-spectral method) is a relatively new noise source/path identification tool. Several researchers have had difficulties implementing this method because of instrumentation phase mis-match. A simple technique for measuring and correcting instrumentation phase mis-match has been developed. This new technique has been tested recently on a noise source identification problem of practical interest. The results of the experiments indicate that the surface acoustic intensity method produces reliable data and can be applied to a variety of noise source/path problems.

Mcgary, M. C.↗

Oxygen and hydrogen atom concentration profiles in the premixed propane/oxygen flame

The oxygen and hydrogen free radical (atom) concentration profiles in the premixed propane/oxygen flame at 92.5% oxygen were determined using electron spin resonance (ESR) spectroscopy techniques. The ESR instrument was specially modified so that the flame can be probed for determining the oxygen and hydrogen atom population densities during the actual combustion process of propane burning in oxygen. The technique used for propane is similar to that suggested by Fristrom and Westenberg to measure the free radical concentration profiles in C-C hydrocarbon/oxygen combustion.

Downs, W. R.↗

Techniques for the Installation of Internal Fiber Optic Instrumentation on an 11-Inch Hybrid Motor Test Bed

The recent developments in Fabry-Perot fiber optic instruments have resulted in accurate transducers with some of the physical characteristics required for use in obtaining internal data from solid rocket motors. These characteristics include small size, non-electrical excitation, and immunity to electro-magnetic interference. These transducers have not been previously utilized in this environment due to the high temperatures typically encountered. A series of tests were conducted using a 1 1-Inch Hybrid test bed to develop installation techniques that will allow the fiber optic instruments to survive and obtain data for a short period of time following the motor ignition. The installation methods developed during this test series have the potential to allow data to be acquired in the motor chamber, propellant bore, and nozzle during the ignition transient. These measurements would prove to be very useful in the characterization of current motor designs and provide insight into the requirements for further refinements. The process of developing these protective methods and the installation techniques used to apply them is summarized.

Cornelius, Michael↗

Time and frequency measuring metrological equipment in the USSR

The complex of the means of providing time and frequency traceability in the USSR includes the system of time and frequency standards of the National Time and Frequency Calibration Service, time and frequency transfer facilities and local time and frequency standards. Control on measurement correctness is performed by the All-Union State Standard calibration service. The hardware of most of the above-mentioned systems is provided by the instruments developed by our institute. A common scientific and technological approach allowed us to create a unified system of time-frequency equipment composed of widely used serial instruments, sets, automated systems and complexes. Primary frequency standards of different classes, time and frequency references and instruments are based on the unified system. CH1-70 hydrogen frequency standard and its CH1-70A, CH1-80 modifications are used in the group time and frequency standards. Measuring time and data processing techniques, and also instrumentation specifications on the results of 10-year operation are given. The existing system provides time-frequency measurements with 2 times 10(exp -13) plus or minus 1 times 10(exp -14) accuracy.

Uljanov, Adolph A.↗

Wind Lidar Edge Technique Shuttle Demonstration Mission: Anemos

A NASA mission is planned to demonstrate the technology for a wind lidar. This will implement the direct detection edge technique. The Anemos instrument will fly on the Space Transportation System (STS), or shuttle, aboard a Hitchhiker bridge. The instrument is being managed by the Goddard Space Flight Center as an in-house build, with science leadership from the GSFC Laboratory for Atmospheres, Mesoscale Atmospheric Processes Branch. During a roughly ten-day mission, the instrument will self calibrate and adjust for launch induced mis-alignments, and perform a campaign of measurements of tropospheric winds. The mission is planned for early 2001. The instrument is being developed under the auspices of NASA's New Millennium Program, in parallel with a comparable mission being managed by the Marshall Space Flight Center. That mission, called SPARCLE, will implement the coherent technique. NASA plans to fly the two missions together on the same shuttle flight, to allow synergy of wind measurements and a direct comparison of performance.

Leete, Stephen J.↗

Fast-response, high-precision carbon monoxide sensor using a tunable diode laser absorption technique

A tunable diode laser instrument, denoted as DACOM (Differential Absorption CO Measurement), has been developed to meet the fast-response, high-precision CO measurement needs of the GTE (Global Tropospheric Experiment) program. Under the GTE program, DACOM participated in the three field missions of CITE 1 (Chemical Instrumentation Test and Evaluation 1), a project involving the intercomparison of trace gas measurement techniques. DACOM performance, including analyses of measurement error sources, is discussed for the ground-based mission at Wallops Island, VA (summer 1983), and two missions on the NASA CV-990 (fall 1983 and spring 1984). Examples of fast-response (about 1 s), high-precision (+ or - 1 part per billion by volume, + or - 1.5 percent of reading) airborne data are included to illustrate the capability of this instrument.

Sachse, Glen W.↗