Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Correlating Flammability of Materials with FTIR Analysis Test Results

The purpose of this experiment was to correlate flammability data with FTIR test results. Kydex 100 is a blend of chlorinated polyvinyl chloride and polymethylmethacrylate, with some filler materials. Samples supplied were 0.125 in. thick. 10 samples were taken from a sheet of Kydex and analyzed for flammability and by FTIR spectroscopy. This material was utilized as a round robin sample for flammability testing. The flammability test results were found to vary across the same sheet.

Moore, Robin↗

SU-F-R-51: Radiomics in CT Perfusion Maps of Head and Neck Cancer

Purpose: The aim of this study was to test the predictive value of radiomics features of CT perfusion (CTP) for tumor control, based on a preselection of radiomics features in a robustness study. Methods: 11 patients with head and neck cancer (HNC) and 11 patients with lung cancer were included in the robustness study to preselect stable radiomics parameters. Data from 36 HNC patients treated with definitive radiochemotherapy (median follow-up 30 months) was used to build a predictive model based on these parameters. All patients underwent pre-treatment CTP. 315 texture parameters were computed for three perfusion maps: blood volume, blood flow and mean transit time. The variability of texture parameters was tested with respect to non-standardizable perfusion computation factors (noise level and artery contouring) using intraclass correlation coefficients (ICC). The parameter with the highest ICC in the correlated group of parameters (inter-parameter Spearman correlations) was tested for its predictive value. The final model to predict tumor control was built using multivariate Cox regression analysis with backward selection of the variables. For comparison, a predictive model based on tumor volume was created. Results: Ten parameters were found to be stable in both HNC and lung cancer regarding potentially non-standardizable factors after the correction for inter-parameter correlations. In the multivariate backward selection of the variables, blood flow entropy showed a highly significant impact on tumor control (p=0.03) with concordance index (CI) of 0.76. Blood flow entropy was significantly lower in the patient group with controlled tumors at 18 months (p<0.1). The new model showed a higher concordance index compared to the tumor volume model (CI=0.68). Conclusion: The preselection of variables in the robustness study allowed building a predictive radiomics-based model of tumor control in HNC despite a small patient cohort. This model was found to be superior to the volume-based model. The project was supported by the KFSP Tumor Oxygenation of the University of Zurich, by a grant of the Center for Clinical Research, University and University Hospital Zurich and by a research grant from Merck (Schweiz) AG.

60 APPLIED LIFE SCIENCES↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Study of liquid and vapor flow into a Centaur capillary device

The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.

Blatt, M. H.↗

Microstructural evolution in the HAZ of Inconel 718 and correlation with the hot ductility test

The nickel-base alloy 718 was evaluated to study the role of preweld heat treatment in reducing or eliminating heat-affected zone hot cracking. Three heat treatments were studied using the Gleeble hot ductility test. A modified hot ductility test was also used to follow the evolution of microstructure during simulated welding thermal cycles. The microstructural evolution was correlated with the hot ductility data in order to evaluate the mechanism of hot cracking in alloy 718. The correlation of hot ductility with microstructure showed that recrystallization, grain growth, and dissolution of precipitates did not in themselves cause any loss of ductility during cooling. Ductility loss during cooling was not initiated until the constitutional liquation of NbC particles was observed in the microstructure. Laves-type phases were found precipitated in the solidified grain boundaries but were not found to correlate with any ductility loss parameter. Mechanisms are reviewed which help to explain how heat treatment controls the hot crack susceptibility of alloy 718 as measured in the hot ductility test.

Thompson, R. G.↗

Application of piezoelectric devices to vibration suppression - From modeling and controller designs to implementation

Embedded piezoelectric devices may be ideally suited for vibration control of space structures, which lack an inertial ground. When subjected to an input voltage, an embedded piezoelectric actuator changes its dimensions, which in turn generates a pair of forces exerted on adjacent structural members. From the direct piezoelectric effect, an embedded piezoelectric transducer generates an electric charge proportional to the structural dynamic response. In this paper, the implementation, testing and modeling of an active truss structure consisting of piezoelectric sensors and actuators are described. Linear quadratic Gaussian (LQG), second-order, and direct rate feedback control schemes are designed to suppress the vibrations of the active structure. Simulation and test results are presented. It is shown that special model reduction considerations are required to achieve good correlation between test and analysis.

Won, Chin C.↗

SU-E-T-157: Evaluation and Comparison of Doses to Pelvic Lymph Nodes and to Point B with 3D Image Guided Treatment Planning for High Dose Brachytherapy for Treatment of Cervical Cancer

Purpose: To estimate and compare the doses received by the obturator, external and internal iliac lymph nodes and point Methods: CT-MR fused image sets of 15 patients obtained for each of 5 fractions of HDR brachytherapy using tandem and ring applicator, were used to generate treatment plans optimized to deliver a prescription dose to HRCTV-D90 and to minimize the doses to organs at risk (OARs). For each set of image, target volume (GTV, HRCTV) OARs (Bladder, Rectum, Sigmoid), and both left and right pelvic lymph nodes (obturator, external and internal iliac lymph nodes) were delineated. Dose-volume histograms (DVH) were generated for pelvic nodal groups (left and right obturator group, internal and external iliac chains) Per fraction DVH parameters used for dose comparison included dose to 100% volume (D100), and dose received by 2cc (D2cc), 1cc (D1cc) and 0.1 cc (D0.1cc) of nodal volume. Dose to point B was compared with each DVH parameter using 2 sided t-test. Pearson correlation were determined to examine relationship of point B dose with nodal DVH parameters. Results: FIGO clinical stage varied from 1B1 to IIIB. The median pretreatment tumor diameter measured on MRI was 4.5 cm (2.7– 6.4cm).The median dose to bilateral point B was 1.20 Gy ± 0.12 or 20% of the prescription dose. The correlation coefficients were all <0.60 for all nodal DVH parameters indicating low degree of correlation. Only 2 cc of obturator nodes was not significantly different from point B dose on t-test. Conclusion: Dose to point B does not adequately represent the dose to any specific pelvic nodal group. When using image guided 3D dose-volume optimized treatment nodal groups should be individually identified and delineated to obtain the doses received by pelvic nodes.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-12: Morphometry Based Measurements of the Structural Response to Whole Brain Radiation

Purpose: Although state of the art radiation therapy techniques for treating intracranial malignancies have eliminated acute brain injury, cognitive impairment occurs in 50–90% of patients who survive >6mo post irradiation. Quantitative characterization of therapy response is needed to facilitate therapeutic strategies to minimize radiation induced cognitive impairment [1]. Deformation based morphometry techniques [2, 3] are presented as a quantitative imaging biomarker of therapy response in patients receiving whole brain radiation for treating medulloblastoma. Methods: Post-irradiation magnetic resonance imaging (MRI) data sets were retrospectively analyzed in N=15 patients, >60 MR image datasets. As seen in Fig 1(a), volume changes at multiple time points post-irradiation were quantitatively measured in the cerebrum and ventricles with respect to pre-irradiation MRI. A high resolution image Template, was registered to the pre-irradiation MRI of each patient to create a brain atlas for the cerebrum, cerebellum, and ventricles. Skull stripped images for each patient were registered to the initial pre-treatment scan. Average volume changes in the labeled regions were measured using the determinant of the displacement field Jacobian. Results: Longitudinal measurements, Fig 1(b-c), show a negative correlation p=.06, of the cerebral volume change with the time interval from irradiation. A corresponding positive correlation, p=.01, between ventricular volume change and time interval from irradiation is seen. One sample t-test for correlations were computed using a Spearman method. An average decrease in cerebral volume, p=.08, and increase in ventricular volume, p<.001, was observed. The radiation dose was seen directly proportional to the induced volume changes in the cerebrum, r=−.44, p<.001, Fig 1(d). Conclusion: Results indicate that morphometric monitoring of brain tissue volume changes may potentially be used to quantitatively assess toxicity and response to radiation and may provide insight in developing new therapeutic approaches and monitoring efficacy.

60 APPLIED LIFE SCIENCES↗

Correlation of SA349/2 Helicopter Flight Test Data with a Comprehensive Rotorcraft Model

A comprehensive rotorcraft analysis model, CAMRAD, was used to predict blade aerodynamic and structural loads and performance for comparison with flight test data. The data were obtained from an SA349/2 helicopter with an advanced geometry rotor. Sensitivity of the correlation to wake geometry, blade dynamics, and blade aerodynamic effects was investigated. Blade chordwise pressure coefficients were predicted for the transonic regimes near the blade tip using the model coupled with two finite-difference codes.

Yamauchi, Gloria K.↗

Performance of AEA 80 Ah Battery Under GEO Profile

To date completed three Solar Dynamic Observatory SDO real-time eclipse seasons. Sony 18650HC has a low rate of capacity fade under GEO cycling regime. Real time test results correlate with accelerated GEO lifetest data and AEA capacity fade prediction tool. This data, together with other AEA test data, justify the SDO Project decision to baseline Lithium-Ion chemistry for the spacecraft battery.

Russel, N.↗

Evaluation of a wind-tunnel gust response technique including correlations with analytical and flight test results

A wind tunnel technique for obtaining gust frequency response functions for use in predicting the response of flexible aircraft to atmospheric turbulence is evaluated. The tunnel test results for a dynamically scaled cable supported aeroelastic model are compared with analytical and flight data. The wind tunnel technique, which employs oscillating vanes in the tunnel throat section to generate a sinusoidally varying flow field around the model, was evaluated by use of a 1/30 scale model of the B-52E airplane. Correlation between the wind tunnel results, flight test results, and analytical predictions for response in the short period and wing first elastic modes of motion are presented.

Redd, L. T.↗

Two-phase flow and heat transfer under low gravity

Spacelab experiment to investigate two-phase flow patterns under gravity uses a water-air mixture experiment. Air and water are circulated through the system. The quality or the mixture or air-water is controlled. Photographs of the test section are made and at the same time pressure drop across the test section is measured. The data establishes a flow regime map under reduced gravity conditions with corresponding pressure drop correlations. The test section is also equipped with an electrical resistance heater in order to allow a flow boiling experiment to be carried out using Freon II. High-speed photographs of the test section are used to determine flow patterns. The temperature gradient and pressure drop along the duct can be measured. Thus, quality change can be measured, and heat transfer calculated.

Walter Frost↗

Three-dimensional random vibration testing definition and simulation

An approach is presented for the definition of 3D random vibration test requirements for multiaxial shaker systems. In particular, it is shown that, by utilizing coherence functions for cross-correlation effects, test requirements can be defined in a simple way and provide a more realistic environmental simulation. The method is applicable to the simulation of all field environments and can be similarly employed to develop laboratory test requirements based on field data. Example problems are presented to demonstrate the approach.

Chang, Kurng Y.↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

Forward Skirt Structural Testing on the Space Launch System (SLS) Program

Structural testing was performed to evaluate heritage forward skirts from the Space Shuttle program for use on the Space Launch System (SLS) program. One forward skirt is located in each solid rocket booster. Heritage forward skirts are aluminum 2219 welded structures. Loads are applied at the forward skirt thrust post and ball assembly. Testing was needed because SLS ascent loads are roughly 40% higher than Space Shuttle loads. Testing objectives were to determine margins of safety, demonstrate reliability, and validate analytical models. Two forward skirts were structurally tested using the test configuration. The test stand applied loads to the thrust post. Four hydraulic actuators were used to apply axial load and two hydraulic actuators were used to apply radial and tangential loads. The first test was referred to as FSTA-1 (Forward Skirt Structural Test Article) and was performed in April/May 2014. The purpose of FSTA-1 was to verify the ultimate capability of the forward skirt subjected to ascent ultimate loads. Testing consisted of two liftoff load cases taken to 100% limit load followed by an ascent load case taken to 110% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The second test was referred to as FSTA-2 and performed in July/August of 2014. The purpose of FSTA-2 was to verify the ultimate capability of the forward skirt subjected to liftoff ultimate loads. Testing consisted of six liftoff load cases taken to 100% limit load followed by the six liftoff cases taken to 140% limit load. Two ascent load cases were then tested to 100% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The forward skirts on FSTA-1 and FSTA-2 successfully carried all applied liftoff and ascent load cases. Both FSTA-1 and FSTA-2 were tested to failure by increasing the ascent loads. Failure occurred in the forward skirt thrust post radius. The forward skirts on FSTA-1 and FSTA-2 had nearly identical failure modes. FSTA-1 failed at 1.72 times limit load and FSTA-2 failed at 1.62 times limit load. This difference is primarily attributed to variation in material properties in the thrust post region. Test data were obtained from strain gages, deflection gages, ARAMIS digital strain measurement, acoustic emissions, and high-speed video. Strain gage data and ARAMIS strain were compared to finite element (FE) analysis predictions. Both the forward skirt and tooling were modeled. This allows the analysis to simulate the loading as close as possible to actual test configuration. FSTA-1 and FSTA-2 were instrumented with over 200 strain gages to ensure all possible failure modes could be captured. However, it turned out that three gages provided critical strain data. One was located in the post bore and two on the post radius. More gages were not specified due to space limitations and the desire to not interfere with the use of the ARAMIS system on the post radius. Measured strains were compared to analysis results for the load cycle to failure. Note that FSTA-1 gages were lost before failure was reached. FSTA-2 gages made it to the failure load but one of the radius gages was lost before testing began. This gage was not replaced because of the time and cost associated with disassembly of the test structure. Correlation to analysis was excellent for FSTA-1. FSTA-2 was not quite as good because there was more residual strain from previous load cycles. FSTA-2 was loaded and unloaded with 12 liftoff cases and two ascent cases before taking the skirt to failure. FSTA-1 only had two liftoff cases and one ascent case before taking the skirt to failure. The ARAMIS system was used to determine strain at the post radius by processing digital images of a speckled paint pattern. Digital cameras recorded images of the speckled paint pattern. ARAMIS strain results for FSTA-2 just prior to failure. Note a high strain location develops near the left side. This high strain compares well to analysis prediction for both FSTA-1 and FSTA-2. The strain at this location was also plotted versus limit load. Both FSTA-1 and FSTA-2 had excellent correlation between ARAMIS and analysis strains. Acoustic emission (AE) sensors were used to monitor for damage formation that may occur during testing (e.g., crack formation and growth or propagation). AE was very important because after disassembly of FSTA-1, a crack was observed in the ball fitting radius. The ball fitting did not crack on FSTA-2. AE data was used to reconstruct when the crack occurred. The AE energy versus time plot for FSTA. The energy increased considerably at 850 seconds (152% limit load), indicating a crack could have formed at this point. The only visual evidence found that could have corresponded to this was the crack that initiated in the ball fitting. The cracks in the forward skirt aluminum structures would likely have been lower energy due to a lower modulus and all that were found after failure correlated to occurring after the initial crack in the post radius. This was verified by high-speed cameras used to record the failure.

Lohrer, J. D.↗

Aridity changes in the Tibetan Plateau in a warming climate

Desertification in the Tibetan Plateau (TP) has drawn increasing attention in the recent decades. It has been postulated as a consequence of climate aridity due to the observed warming. This study quantifies the aridity changes in the TP and attributes the changes to different climatic factors. Using the ratio of P/PET (precipitation to potential evapotranspiration) as an aridity index to indicate changes in dryness and wetness in a given area, P/PET was calculated using observed records at 83 stations in the TP, with PET calculated using the Penman–Monteith (PM) algorithm. Spatial and temporal changes of P/PET in 1979-2011 are analyzed. Results show that stations located in the arid and semi-arid northwestern TP are becoming significantly wetter and stations in the semi-humid southeastern TP are becoming drier, though not significantly, in the recent three decades. The aridity change patterns are significantly correlated with precipitation, sunshine duration and diurnal temperature range changes at confidence level of 99.9% from two-tail t-test. Temporal correlations also confirm the significant correlation between aridity changes with the three variables, with precipitation being the most dominant driver of P/PET changes at interannual time scale. PET changes are insignificant but negatively correlated with P/PET in the cold season. In the warm season, however, correlation between PET changes and P/PET changes are significant at confidence level of 99.9% when the cryosphere melts near the surface. Significant correlation between wind speed changes and aridity changes occurs in limited locations and months. Consistency in the climatology pattern and linear trends in surface air temperature and precipitation calculated using station data, gridded data, and nearest grid-to-stations for the TP average and across sub-basins indicate the robustness of the trends despite the large spatial heterogeneity in the TP that challenge climate monitoring.

54 ENVIRONMENTAL SCIENCES↗