Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

How Do You Measure That Ceramic Property?

By using the dozens of consensus test standards and practices developed by the Advanced Ceramics Committee of ASTM, C-28, the measurement of mechanical, physical, thermal, and performance properties can be properly performed. The what, how, how not, and why are clearly illustrated for beginning as well as experienced testers. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results. The C-28 Committee has involved academics, and producers, and users of ceramics to write and continually update more than 45 standards since the committee's inception in 1986.

Salem, Jonathan↗

Advanced Ceramics Property and Performance Measurements

Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the what, how, how not, and why for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committees inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of all of the standards in one volume.

strength↗

Advanced Ceramics Property Measurements

Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the "what, how, how not, and why" for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committee's inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of standards in one volume.

Salem, Jonathan↗

GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} for Fukushima Daiichi Water Treatment Secondary Wastes - 20212

The Japanese government is supporting development work implemented jointly by Veolia subsidiaries Kurion Japan, K.K., Veolia Nuclear Solutions (VNS), Inc., and Veolia Nuclear Solutions Federal Services, LLC for treating radioactive waste generated from Fukushima Daiichi Nuclear Power Station (NPS) water treatment using the GeoMelt{sup TM} In-Container Vitrification (ICV){sup TM} technology. The initial work consisted of glass formulation and engineering-scale testing which was completed in 2018, in the frame of an IRID (International Research Institute for Nuclear Decommissioning) program as part of a project subsidized by Japan's Ministry of Economy, Trade and Industry (METI). The Fukushima Daiichi NPS Mid- and Long-Term Road-map requires investigation of methods to stabilize solid wastes (and to immobilize radioisotopes in the wastes) generated as a result of emergency response and decommissioning activities. Cooling water treatment has resulted in a significant amount of solid and slurry secondary wastes (mostly adsorbents and ion-exchange materials) which will require processing at some point. GeoMelt{sup R} ICV{sup TM} is a joule-heated melter technology which uses a refractory-lined single-use container combining the melter and disposal container. There is no pouring required nor concerns with refractory corrosion which allows the process to accommodate a wide range of waste chemistries and high waste loadings. The testing described here consisted of three engineering-scale melts, each processing between 212 kg and 240 kg of waste simulants, glass formers, and non-radioactive cesium (Cs) and strontium (Sr) tracers. Continuous isokinetic stack sampling of off-gas emissions was performed for each test in order to calculate Cs and Sr retention in the glass wasteform. Single-pass retention of Cs in the final glass wasteform ranged from 91.46 to 99.30%, and single-pass retention of Sr ranged from 99.76 to 100%. Planned particulate recycle will increase these retention levels. Melt 1 processed a mixture of KUR-EH (a zeolite-based ion-exchange material), simulated Advanced Liquid Processing System (ALPS) Carbonate and Iron Slurries, and glass additives. Melt 2 processed a mixture of KUR-EH, KUR-TSG (a titanate-based adsorbent), and glass additives. Melt 3 processed a mixture of KUR-EH, simulated barium sulfate/iron ferrocyanide sludge (AREVA sludge), and glass additives. Waste loadings for these melts ranged from 70 weight percent (wt%) to 82 wt%. Vitrification produces a waste form much denser than the stored water treatment secondary waste wastes, resulting in significant volume reduction. Volume reductions for the three tests ranged from 74 to 79 vol%. Vitrification produces a chemically durable wasteform. Pacific Northwest National Laboratory (PNNL) tested three glass samples from each engineering-scale melt) by the Materials Characterization Center 1 (MCC-1) test, an international standard leach test of the chemical durability of nuclear waste glasses. PNNL also obtained one U.S. reference glass (EA Glass) and two Japan reference glasses P0798) and tested these under the same MCC-1 conditions (90 deg. C, 10 m-1, DIW, and 7, 14, 28-day) as the GeoMelt{sup R} ICV{sup TM} glasses. The GeoMelt{sup R} ICV{sup TM} glasses exhibited lower total normalized releases and 14- to 28-day normalized release rates than the three reference glasses. These results suggest that the GeoMelt{sup R} ICV{sup TM} glasses have durabilities on par with high-level waste glasses under standard test conditions. Post-melt process sampling and analysis indicated no Cs migration into the melter refractory materials and very little deposition of Cs or Sr onto the melter hood or off-gas piping internals. The results of the testing indicated good Cs retention in the glass, high volume reduction and waste loadings, and excellent chemical durability. These factors are important to minimize treatment costs and to protect workers and the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measured Performance of Residential Dehumidifiers Under Cyclic Operation

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. In this project, researchers at the National Renewable Energy Laboratory (NREL) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, the team tested the part load performance of four residential dehumidifiers in NREL’s Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bench-Scale Apparatus for Rapid, Simultaneous, Comprehensive Vapor–Liquid Equilibrium and Kinetic Property Measurements to Advance CO 2 Capture Solvent Technology

We present here, the design, fabrication, and testing of a new "pressure, volume, temperature (PVT)" apparatus that enables rapid standardized testing for viscosity, vapor–liquid equilibria, and kinetics for water-lean carbon capture solvents. This unit is the first of its kind where equilibrium data are collected during operation as a PTx (pressure–temperature–composition) cell while kinetic data are collected simultaneously with an internal mini wetted-wall contactor (WWC) using controlled adjustments of CO 2 injections to allow for measurements of gas flux (in and out of the liquid). Additionally, in situ measurements of viscosity data are also continuously collected while a solvent is in circulation during gas absorption. This cell empowers comprehensive testing of critical CO 2 capture solvent properties in a single measurement, ensuring all data are collected at the same temperature, pressure, and CO 2 loading. This apparatus also expedites screening of materials since less than 50 mL of sample is needed as compared to 2–3 L needed to get similar data from a conventional WWC. In conclusion, we describe here the methodology of data collected on this new PVT cell, nicknamed “Gary” in honor of Professor Gary Rochelle, for multiple water-lean amine solvents, which we compare to data collected from conventional instrumentation for amine testing.

Zheng, Richard [STARS Technology Corporation, Rich↗

Development of automated electromagnetic compatibility test facilities at Marshall Space Flight Center

The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.

Harrison, Cecil A.↗

Application of Simulated Reactivity Feedback in Nonnuclear Testing of a Direct-Drive Gas-Cooled Reactor

Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.

Bragg-Sitton, S. M.↗

Promoting Robust Design of Diode Lasers for Space: A National Initiative

The Diode-laser Array Working Group (DAWG) is a national-level consumer/provider forum for discussion of engineering and manufacturing issues which influence the reliability and survivability of high-power broad-area laser diode devices in space, with an emphasis on laser diode arrays (LDAs) for optical pumping of solid-state laser media. The goals of the group are to formulate and validate standardized test and qualification protocols, operational control recommendations, and consensus manufacturing and certification standards. The group is using reliability and lifetime data collected by laser diode manufacturers and the user community to develop a set of standardized guidelines for specifying and qualifying laser diodes for long-duration operation in space, the ultimate goal being to promote an informed U.S. Government investment and procurement strategy for assuring the availability and durability of space-qualified LDAs. The group is also working to establish effective implementation of statistical design techniques at the supplier design, development, and manufacturing levels to help reduce product performance variability and improve product reliability for diodes employed in space applications

Tratt, David M.↗

Opposed-Flow Flame Spread in a Narrow Channel Apparatus over Thin PMMA Sheets

Flame spread tests have been conducted over polymethylmethacrylate (PMMA) samples in San Diego State University's Narrow Channel Apparatus (SDSU NCA). The Narrow Channel Apparatus (NCA) has the ability to suppress buoyant flow in horizontally spreading flames, and is currently being investigated as a possible replacement or complement to NASA's current material flammability test standard for non-metallic solids, NASA-STD-(I)-6001B Test 1. The buoyant suppression achieved with a NCA allows for tests to be conducted in a simulated microgravity atmosphere-a characteristic that Test 1 lacks since flames present in Test 1 are buoyantly driven. The SDSU NCA allows for flame spread tests to be conducted with varying opposed flow oxidizer velocities, oxygen percent by volume, and total pressure. Also, since the test sample is placed symmetrically between two confining plates so that there is a gap above and below the sample, this gap can be adjusted. This gap height adjustment allows for a compromise between heat loss from the flame to the confining boundaries and buoyancy suppression achieved by those boundaries. This article explores the effect gap height has on the flame spread rate for 75 μm thick PMMA at 1 atm pressure and 21% oxygen concentration by volume in the SDSU NCA. Flame spread results from the SDSU NCA for thin cellulose fuels have previously been compared to results from tests in actual microgravity at various test conditions with the same sample materials and were found to be in good agreement. This article also presents results from the SDSU NCA for PMMA at 1 atm pressure, opposed oxidizer velocity ranging from 3 to 35 cm/s, oxygen concentration by volume at 21%, 30 %, and 50% and fuel thicknesses of 50 and 75 μm. These results are compared to results obtained in actual microgravity for PMMA obtained at the 4.5s drop tower of MGLAB in Gifu, Japan, and the 5.2s drop tower at NASA's Zero-Gravity Research Facility in Cleveland, OH. This comparison confirms that at 1 atm pressure, the SDSU NCA successfully simulates microgravity for not only thin cellulose fuels, but also for thin PMMA sheets as well. This further supports the idea that the NCA is a viable option to complement or replace NASA's Test 1 for material flammability testing. Tests with thick fuels will be conducted in the future to further characterize the SDSU NCA.

flame spread↗

Natural Environment Corrosion Testing at the Kennedy Space Center Beachside Atmospheric Corrosion Test Site

This presentation will provide an overview of how NASA has been conducting corrosion testing in the Natural Marine Environment at the Kennedy Space Center, Florida, U.S. The following questions will be addressed: What factors should be considered when selecting and constructing a test site? What are the attributes of a good test site? Is more severe always better? What environmental parameters should be monitored? How frequently? What factors should be considered when designing test specimens? Are current test standards sufficient? How do diurnal, annual and other fluctuations in corrosivity influence tests? How are test results interpreted? Can they be quantified?

Corrosion↗

Standardizing GPU Radiation Test Approaches

While some Graphical Processing Units (GPUs) are discrete components (i.e.GTX1050), others take the form of an IP block or embedded engine within a System on Chip (SoC) device such as the Qualcomm Snapdragon"TM" 820 which contains a Qualcomm Adreno"TM" 530 GPU. Within this device are various functional blocks which can be exercised with software payloads. NVidia's Jetson"TM" TX1 SoC is provided on a System on Module (SOM). Within it are Central Processing Unit (CPU) cores and an nVidia GPU which can be accessed similarly to a discrete GPU coprocessor. While the packaging is different, each one of these GPUs needs to be tested using the same standardized code.

Single Event Effects (SEE)↗

Scroll Filter System Development for Crewed Deep Space Missions

On board the International Space Station, particulate HEPA filters known as Bacterial Filter Elements (BFE's) are used as the main ventilation filters on the US modules. They consist of two stages of filtration, a static screen filter and a HEPA filter element. Historically, these filters have performed well during the life of the ISS. However, as NASA sets its sights towards mission beyond low earth orbit, or deep space, more capable filters requiring minimal maintenance will be essential because of the nature of these remote and of long duration missions. Therefore NASA is currently developing new filter systems for these mission. One of the filter designs being considered is a new filter system, coined the Scroll BFE. This filter provides two stages of filtration. The first stage is a pre-filter stage using a roll of screen media on a motorized spooling, or scrolling, mechanism to automate the change-out of the screen media in the flow. The second and finishing stage is a static HEPA filter element similar to the ones used on the ISS BFE's. The volume and dimensional format of the filter matches that of the ISS BFE which facilitates is deployment as potential future flight technology demonstration on board the ISS. Ground tests are underway to assess the filter system's performance under industrial standard test protocols applied in a custom designed filtration test stand. In addition, a method of generating relevant particulate matter loads, such as loose fibrous matter, is also being devised to challenge the filter in testing. The latter test challenge will help determine the pre-filter's capacity for handling layers of lint, or fibrous, particulate matter. Early results confirm HEPA efficiency performance of the HEPA stage. This paper will present the results of ground testing of the Scroll Filter System prototype.

Agui, Juan H.↗

Performance assessment on continuous air monitors under real operating conditions

In the nuclear industry, workers may be exposed to artificial radioactive aerosols. These aerosols are generally composed of particles with a diameter measuring between 0.1 {mu}m and 10 {mu}m. To protect workers in nuclear facilities, monitors that continuously measure radioactivity in the air are used. The main function of the monitor is to provide real-time measurement of activity concentration. Measurement of aerosol activity concentration can be affected by a number of factors specific to the aerosols and the instrument. The first part of the article will present the general operating principles of continuous air monitors (CAMs) and inherent measurement difficulties, as well as the main standard tests. The second section describes the experimental ICARE facility The ICARE facility generates standard artificial and natural radioactive aerosols for calibrating continuous air monitors under real operating conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗

Interlaminar fracture characterization: A current review

Interlaminar fracture characterization has been investigated for several years. Only now is it well enough understood for standardization organizations to attempt to write standard test methods. A review of the current philosophies in characterizing interlaminar fracture is presented. First, the mode 1, double cantilever beam test (DCB) for measuring G(sub 1c) and the end notched flexure (ENF) test for measuring G(sub 2c) are discussed. These tests have undergone the most extensive research throughout the years and are furthest towards standardization. In addition, the mode 2, end loaded split (ELS) specimen is discussed. Mixed mode fracture is also discussed and the recently developed mixed mode bending (MMB) test is detailed. Then, tests for evaluating mode 3 fracture toughness, including the split cantilever beam (SCB), are reviewed. Finally, the work done on interlaminar fracture characterization in fatigue is reviewed.

Martin, Roderick H.↗

Wall-Modeled Lattice Boltzmann and Navier-Stokes Approaches for Separated Flows

Lattice Boltzmann (LB) and hybrid Reynolds-averaged Navier-Stokes/large eddy simulation (RANS/LES) methods within the Launch Ascent and Vehicle Aerodynamics (LAVA) solver framework are applied to NASA's Revolutionary Computational Aerosciences (RCA) standard test cases for separated flows. A detailed comparison between the performance and accuracy of the two emerging numerical methodologies for turbulence resolving simulations, i.e. the LB and hybrid RANS/LES methods will be presented. This contribution addresses the RCA technical challenge to identify and down-select critical turbulence, transition, and numerical method technologies for 40% reduction in predictive error for standard turbulence separated flow test cases. Results for the 2D NASA wall-mounted hump and the axisymmetric transonic bump including time-averaged pressure coefficient, skin friction, and velocity pro les, as well as resolved and modeled Reynolds stresses for both numerical approaches will be presented and differences between LB and hybrid RANS/LES will be discussed.

Lattice Boltzmann↗

The use of subjective expert opinions in cost optimum design of aerospace structures

The results of two questionnaires sent to engineering experts are statistically analyzed and compared with objective data from Saturn V design and testing. Engineers were asked how likely it was for structural failure to occur at load increments above and below analysts' stress limit predictions. They were requested to estimate the relative probabilities of different failure causes, and of failure at each load increment given a specific cause. Three mathematical models are constructed based on the experts' assessment of causes. The experts' overall assessment of prediction strength fits the Saturn V data better than the models do, but a model test option (T-3) based on the overall assessment gives more design change likelihood to overstrength structures than does an older standard test option. T-3 compares unfavorably with the standard option in a cost optimum structural design problem. The report reflects a need for subjective data when objective data are unavailable.

Thomas, J. M.↗