Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

EGS Collab Experiment 3: 4100 Tensile Stimulation and Thermal Circulation Testing

These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF). Stimulations were carried out between April and May of 2022. The thermal circulation test ran semi-continuously from May 19 through August 26, 2022, though chilled water injection began on June 3. More information about the test, rationale, and processing of data is available on the EGS Collab project page, which is linked below.

15 GEOTHERMAL ENERGY↗

A thermal vacuum test optimization procedure

An analytical model was developed that can be used to establish certain parameters of a thermal vacuum environmental test program based on an optimization of program costs. This model is in the form of a computer program that interacts with a user insofar as the input of certain parameters. The program provides the user a list of pertinent information regarding an optimized test program and graphs of some of the parameters. The model is a first attempt in this area and includes numerous simplifications. The model appears useful as a general guide and provides a way for extrapolating past performance to future missions.

Kruger, R.↗

A new approach for performing contamination control bakeouts in JPL thermal vacuum test chambers

Contamination control requirements for the Wide Field/Planetary Camera II (WF/PC II) are necessarily stringent to protect against post-launch contamination of the sensitive optical surfaces, particularly the cold charge coupled device (CCD) imaging surfaces. Typically, thermal vacuum test chambers have employed a liquid nitrogen (LN2) cold trap to collect outgassed contaminants. This approach has the disadvantage of risking recontamination of the test article from shroud offgassing during post-test warmup of the chamber or from any shroud warming of even a few degrees during the bakeout process. By using an enclave, essentially a chamber within a chamber, configured concentrically and internally within an LN2 shroud, a method was developed, based on a design concept by Taylor, for preventing recontamination of test articles during bakeouts and subsequent post-test warmup of the vacuum chamber. Enclaves for testing WF/PC II components were designed and fabricated, then installed in three of JPL's Environmental Test Lab chambers. The design concepts, operating procedures, and test results of this development are discussed.

Johnson, Kenneth R.↗

Cryogenic Shrouds for Testing Thermal-Insulation Panels

Cryogenic shrouds have been designed and built for use in thermomechanical testing of samples of thermalinsulation panels on cryogenic vessels. In the original application for which these shrouds were specifically designed, the samples are representative of the large-area thermal-insulation panels on the space-shuttle external tanks that hold liquid hydrogen and liquid oxygen, and the purpose of the testing is to demonstrate the ability of bonded layers in the panels to resist delamination under a combination of applied uniaxial mechanical loads and realistic operational temperatures. Presumably, the shrouds and the tests performed by use of them could be modified to enable similar evaluation of thermomechanical properties of thermal-insulation panels for cryogenic vessels other than the external tanks of the space shuttles. The shrouds are required to enable maintenance of required temperatures on the inner and outer surfaces of the thermal-insulation-panel samples, to enable visual observation of the outer surfaces of the samples, and not to introduce any measurable loads into the panels. For each panel sample, there are two shrouds: one to be mounted on the inner surface (the surface that would be in contact with a tank containing a cryogenic liquid during normal use) and one to be mounted on the outer surface (the surface that would be exposed to ambient air or other warmer environment during normal use). The shrouds for testing specimens of thermal-insulation- panels for the liquid-hydrogen tank are made largely of titanium; the shrouds for testing specimens of thermal- insulation-panels for the liquid-oxygen tank are made largely of an aluminum- lithium alloy. The specific temperature requirements are the following: The inner shroud must make it possible to maintain a temperature of 321 degrees F (196 degrees C) [the approximate temperature of liquid nitrogen] or 453 F (about 269 C) [the approximate temperature of liquid helium] on the inner face of the sample. The outer shroud must make it possible to maintain a temperature between 30 degrees and 0 degrees F (between about 34 degrees and about 18 degrees C) on the outer surface of the sample by blowing a cryogenic gas or missile grade air along that surface. To enable viewing of the outer surface of the sample during testing, the outer shroud includes a window comprising two layers of poly(methyl methacrylate) with a gap between them to reduce fogging. To ensure that the shrouds do not introduce any measurable loads into a panel specimen, the shrouds are cushioned on the specimen by seals made of a fluoropolymer-membrane/fabric composite material and are held in place on the specimen by means of symmetrically placed clamps with poly(tetrafluoroethylene) pads. Instrumentation ports for thermocouples and strain gauges used in the tests are incorporated into the shrouds.

Norris, Jeffrey↗

Thermal Vacuum Testing of Swift XRT Ethane Heat Pipes

This paper presents the results obtained from a recent ethane heat pipe program. Three identical ethane heat pipes were tested individually, and then two selected heat pipes were tested collectively in their system configuration. Heat transport, thermal conductance, and non-condensable gas tests were performed on each heat pipe. To gain insight into the reflux operation as seen at spacecraft level ground testing, the test fixture was oriented in a vertical configuration. The system level test included a computer-controlled heater designed to emulate the heat load generated at the thermoelectric cooler interface. The system performance was successfully characterized for a wide range of environmental conditions while staying within the operating limits.

Kobel, Mark↗

Experimental Thermal Performance Testing of Cryogenic Tank Systems and Materials

A comparative study was conducted to collect and analyze thermal conductivity data on a wide variety of low density materials, as well as thermal performance data on a number of vacuum-jacketed cryogenic tank systems. Although a vast number of these types of materials and cryogenic tank systems exist, the thermal conductivity of insulation materials and the thermal performance of cryogenic tank systems is often difficult to compare because many industrial methods and experimental conditions are available and utilized. The availability of a new thermal conductivity measurement device, the Macroflash Cup Cryostat, which is applicable for assessing a variety of materials, is accessible at NASA's Cryogenic Test Laboratory (CTL) at the Kennedy Space Center (KSC). The convenience of this device has resulted in the ability to rapidly measure the thermal conductivity properties of these materials by using a flat-plate liquid nitrogen (LN2) boiloff technique that employs a guarded heat flow test methodology in order to determine the effective thermal conductivity (ke) of a test specimen. As the thermal conductivities are measured at cryogenic temperatures, materials suitable for both future space missions and cryogenic tank systems can be identified and experimentally analyzed. Also recognizable are materials which may help increase energy efficiency by limiting the thermal losses encountered under various environmental conditions. The overall focus of this work consisted of two parts. One part, was to produce and analyze thermal conductivity data on a wide variety of materials with suitable properties conducive to those needed to aid in the production of a calibration curve for the "low end" of the Macroflash instrument. (Low end meaning materials with a thermal conductivity rating below 100 milliwatts per meter-Kelvin). The second part was to collect and analyze heat transfer data for a variety of small vacuum-jacketed vessels (cryogenic tank systems) in order to compare the thermal performance between them.

Myers, Wesley C.↗

Design and Fabrication of a Stirling Thermal Vacuum Test

A Stirling Radioisotope Generator (SRG110) is being developed for potential use on future NASA space science missions. The development effort is being conducted by Lockheed Martin under contract to the Department of Energy (DOE). The Stirling Technology Company supplies the free-piston Stirling power convertors, and NASA Glenn Research Center (GRC) provides support to the effort in a range of technologies. This generator features higher efficiency and specific power compared to the currently used alternatives. One potential application for the generator would entail significant cruise time in the vacuum of deep space. A test has been conceived at GRC to demonstrate functionality of the Stirling convertors in a thermal vacuum environment. The test article resembles the configuration of the SRG, however the requirement for low mass was not considered. This test will demonstrate the operation of the Stirling convertors in the thermal vacuum environment, simulating deep space, over an extended period of operation. The analysis, design, and fabrication of the test article will be described in this paper.

Oriti, Salvatore M.↗

Design and Fabrication of a Stirling Thermal Vacuum Test

A Stirling Radioisotope Generator (SRG110) is being developed for potential use on future NASA space science missions. The development effort is being conducted by Lockheed Martin under contract to the Department of Energy (DOE). The Stirling Technology Company supplies the free-piston Stirling power convertors, and NASA Glenn Research Center (GRC) provides support to the effort in a range of technologies. This generator features higher efficiency and specific power compared to the currently used alternatives. One potential application for the generator would entail significant cruise time in the vacuum of deep space. A test has been conceived at GRC to demonstrate functionality of the Stirling convertors in a thermal vacuum environment. The test article resembles the configuration of the SRG, however the requirement for low mass was not considered. This test will demonstrate the operation of the Stirling convertors in the thermal vacuum environment, simulating deep space, over an extended period of operation. The analysis, design, and fabrication of the test article will be described in this paper.

Oriti, Salvatore M.↗

Thermal Performance Testing of Single Channel GRCop-84 SLM Components

The surface finish found on components manufactured by sinter laser manufacturing (SLM) is rougher (0.013 - 0.0006 inches) than parts made using traditional fabrication methods. Internal features and passages built into SLM components do not readily allow for roughness reduction processes. Alternatively, engineering literature suggests that the roughness of a surface can enhance thermal performance within a pressure drop regime. To further investigate the thermal performance of SLM fabricated pieces, several GRCop‐84 SLM single channel components were tested using a thermal conduction rig at MSFC. A 20 kW power source running at 25% duty cycle and 25% power level applied heat to each component while varying water flow rates between 2.1 - 6.2 gallons/min (GPM) at a supply pressure of 500 to 750 psi. Each test was allowed to reach quasi‐steady state conditions where pressure, temperature, and thermal imaging data were recorded. Presented in this work are the heat transfer responses compared to a traditional machined OHFC Copper test section. An analytical thermal model was constructed to anchor theoretical models with the empirical data.

Garcia, Chance P.↗

Computer assisted thermal-vacuum testing

In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.

Petrie, W.↗

Techniques associated with thermal-vacuum testing of the OAO C heat pipes

The mechanical problems associated with the testing of two heat pipes installed in the OAO C spacecraft are described. The test problems discussed concern the specially designed heat removal devices, the mobile tilt table, the table position indicator, and the heat input machanisms. It was determined that the techniques used were adequate for thermal-vacuum testing of heat pipes.

Marshburn, J. P.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The discovery of a new class of ceramic superconductors with transition temperatures above the boiling point of liquid nitrogen has opened the doors for several space applications. One important space application is the fabrication of an electrically conducting and thermally isolating link to replace manganin wires used in connecting IR detectors to data acquisition electronics on remote sensing platforms like SAFIRE and SIRTF. These NASA platforms designed to monitor the earth's atmosphere from space use infrared detectors which operate at liquid helium temperature (4.2K) for optimum performance. The SAFIRE mission employs hybrid dewars which combine both mechanical and cryogenic liquid cooling. The lifetime of such a mission is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). Currently these remoter sensing systems use manganin wires to connect the IR detectors to the data acquisition electronics. This link between a detector operating at 4 K and electronics operating at 80 K must be made of material that has high electrical conductivity and high thermal resistance. The YBCO superconductor with a transition temperature, Tc, of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. The fabrication of an electrically conducting and thermally isolating link that replaces the manganin wires is an important application that will improve thermal isolation of IR detectors and will increase the lifetime of the cryogen. The link is made by screen printing superconducting lines on a low thermal conductivity ceramic substrate. Developing, modeling, and testing this high temperature superconducting link is a collaborative effort among NASA-Langley Research Center, Christopher Newport University (CNU), Clemson University and the industrial companies that have joined the Commercialization of Space Program for the purpose of developing and testing this link. CNU's effort in the development of this superconducting link included the following major efforts: (1) Development of a thermal conductivity measurement system for high temperature superconductors and ceramic materials which are potential candidates for use as substrates in this link. (2) Development of a mathematical model for the superconducting link that studies the effect of materials and geometry on the heat load and life time of missions. (3) Characterization of high Tc materials and assemblies made for space applications. Properties studied include humidity effects and aging effects on high Tc materials. This report summarizes the results of the research studies that were completed. Copies of publications detailing these findings are attached to this report.

Selim, Raouf R.↗

Additive Manufacturing Thermal Performance Testing of Single Channel GRCop-84 SLM Components

The surface finish found on components manufactured by sinter laser manufacturing (SLM) is rougher (0.013 - 0.0006 inches) than parts made using traditional fabrication methods. Internal features and passages built into SLM components do not readily allow for roughness reduction processes. Alternatively, engineering literature suggests that the roughness of a surface can enhance thermal performance within a pressure drop regime. To further investigate the thermal performance of SLM fabricated pieces, several GRCop-84 SLM single channel components were tested using a thermal conduction rig at MSFC. A 20 kW power source running at 25% duty cycle and 25% power level applied heat to each component while varying water flow rates between 2.1 - 6.2 gallons/min (GPM) at a supply pressure of 550 to 700 psi. Each test was allowed to reach quasi-steady state conditions where pressure, temperature, and thermal imaging data were recorded. Presented in this work are the heat transfer responses compared to a traditional machined OHFC Copper test section. An analytical thermal model was constructed to anchor theoretical models with the empirical data.

Garcia, Chance P.↗

Extreme Dimensional Stability Thermal Control Test

Two observatories under consideration in the 2020 decadal survey include coronagraphs for characterizing the atmospheric composition of exoplanets. The telescope in those observatories must provide a wavefront that is stable to the picometer level for the coronagraph to provide enough starlight rejection to capture light reflected off of an Earth-like exoplanet. Therefore, picometer dimensional stability and control are required for these missions. Analysis indicates the thermal environment around the primary mirror must be stable to milliKelvin for the primary mirror’s thermally induced wavefront error to be stable to picometers. Marshall Space Flight Center (MSFC) partnered with L3-Harris Corporation to design and build a 1.5mthermal control system capable of milliKelvin stability. MSFC tested this thermal control system in the X-Ray and Cryogenic Facility’s large chamber to characterize how well the system controlled a 1.5m ULE® mirror.

optomechanical↗

Managing the Mars Science Laboratory Thermal Vacuum Test for Safety and Success

The Mars Science Laboratory is a NASA/JPL mission to send the next generation of rover to Mars. Originally slated for launch in 2009, development problems led to a delay in the project until the next launch opportunity in 2011. Amidst the delay process, the Launch/Cruise Solar Thermal Vacuum Test was undertaken as risk reduction for the project. With varying maturity and capabilities of the flight and ground systems, undertaking the test in a safe manner presented many challenges. This paper describes the technical and management challenges and the actions undertaken that led to the ultimate safe and successful execution of the test.

Evans, Jordan P.↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Hubble Space telescope thermal cycle test report for large solar array samples with BSFR cells (Sample numbers 703 and 704)

The Hubble space telescope (HST) solar array was designed to meet specific output power requirements after 2 years in low-Earth orbit, and to remain operational for 5 years. The array, therefore, had to withstand 30,000 thermal cycles between approximately +100 and -100 C. The ability of the array to meet this requirement was evaluated by thermal cycle testing, in vacuum, two 128-cell solar cell modules that exactly duplicated the flight HST solar array design. Also, the ability of the flight array to survive an emergency deployment during the dark (cold) portion of an orbit was evaluated by performing a cold-roll test using one module.

Alexander, D. W.↗