Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal vacuum testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along with Model Correlation and Application

After 39 years of continuous operation in space, the output of the Voyager 1 & 2 spacecraft RTG power systems has decreased to the point where managing the power margin and maintaining thermal control has become increasingly difficult. As the total power dissipation in the bus has decreased, propellant line temperatures and margin above minimum AFTs have decreased, creating risk of the hydrazine freezing (at 1.6°C). This is further complicated by the lack of existing thermal models that can be used to assess propellant tank and line temperatures. In 2014, an effort was begun to create a Voyager spacecraft thermal model for that purpose.A steady-state Thermal Desktop model has been created from scratch over the past two years. The initial thermal model development was started by Applied Sciences Laboratory (ASL) under contract to JPL. The effort relied primarily on archived manufacturing drawings, limited documentation, interviews of senior engineers who worked on the Voyager design and implementation, and the experience of the Voyager Flight Operations team.Data from the Voyager System Thermal Vacuum tests is no longer available, making it necessary to correlate the model to more recent flight data and small in-flight tests. Correlation was achieved to within ±5°C for a hot case and a cold case (both data sets from 2014). However, the flight system has very few temperature sensors directly on propellant lines. So the task remains to determine how best to use the model, in conjunction with flight data, to make sure the Voyagers can continue to fly successfully. How does one go about creating a thermal model for a spacecraft that is already launched, has limited existing mechanical description files, no thermal model in order to do a maneuver that was never planned when the spacecraft was designed?

Ledeboer, William C.↗

Shape Morphing Adaptive Radiator Technology (SMART) Updates to Techport Entry

The Shape-Morphing Adaptive Radiator Technology (SMART) project builds off the FY16 research effort that developed a flexible composite radiator panel and demonstrated its ability to actuate from SMA's attached to it. The proposed FY17 Shape-Morphing Adaptive Radiator Technology (SMART) project's goal is to 1) develop a practical radiator design with shape memory alloys (SMAs) bonded to the radiator's panel, and 2) build a multi-panel radiator prototype for subsequent system level thermal vacuum tests. The morphing radiator employs SMA materials to passively change its shape to adapt its rate of heat rejection to vehicle requirements. Conceptually, the radiator panel has a naturally closed position (like a cylinder) in a cold environment. Whenever the radiator's temperature gradually rises, SMA's affixed to the face sheet will pull the face sheet open a commensurate amount - increasing the radiators view to space and causing it to reject more heat. In a vehicle, the radiator's variable heat rejection capabilities would reduce the number of additional heat rejection devices in a vehicle's thermal control system. This technology aims to help achieve the required maximum to minimum heat rejection ratio required for manned space vehicles to adopt a lighter, simpler, single loop thermal control architecture (ATCS). Single loop architectures are viewed as an attractive means to reduce mass and complexity over traditional dual-loop solutions. However, fluids generally considered safe enough to flow within crewed cabins (e.g. propylene glycol-water mixtures) have much higher freezing points and viscosities than those used in the external sides of dual loop ATCSs (e.g. Ammonia and HFE7000).

Erickson, Lisa↗

Europa Clipper Magnetometer Thermal Design Evolution, Validation, and Verification

Europa Clipper Spacecraft is exposed to a high radiation environment and is limited with power. This makes the thermal design of Europa Clipper magnetometer more challenging. The design is required to be highly insulated and at the same time magnetically clean. This paper describes the thermal design evolution of Europa Clipper Magnetometer. A thermal vacuum test is conducted in Europa Clipper orbit’s relevant environment to characterize the requirements and estimate the power consumption. A flight-like engineering model magnetometer from the University of California at Los Angeles (UCLA) is used for this test. Magnetically clean Cernox temperature measurement sensors with the accuracy of ±0.1ºC are used to measure the temperature value inside the sensor head and across the main frame interfaces. This level of accuracy in temperature measurement is required to capture the temperature gradient across the sensor head in a relevant environment which impacts the magnetometer measurement accuracy. Test data is used to correlate the thermal model and characterize the heat leak across the interfaces. Validated thermal model is used as a verification tool for power consumption and thermal requirements.

Caron, Ryan↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

Thermal Control Systems↗

Loop Heat Pipe Temperature Oscillation Induced by Gravity Assist and Reservoir Heating

The Laser Thermal Control System (LCTS) for the Advanced Topographic Laser Altimeter System (ATLAS) to be installed on NASA's Ice, Cloud, and Land Elevation Satellite (ICESat-2) consists of a constant conductance heat pipe and a loop heat pipe (LHP) with an associated radiator. During the recent thermal vacuum testing of the LTCS where the LHP condenser/radiator was placed in a vertical position above the evaporator and reservoir, it was found that the LHP reservoir control heater power requirement was much higher than the analytical model had predicted. Even with the control heater turned on continuously at its full power, the reservoir could not be maintained at its desired set point temperature. An investigation of the LHP behaviors found that the root cause of the problem was fluid flow and reservoir temperature oscillations, which led to persistent alternate forward and reversed flow along the liquid line and an imbalance between the vapor mass flow rate in the vapor line and liquid mass flow rate in the liquid line. The flow and temperature oscillations were caused by an interaction between gravity and reservoir heating, and were exacerbated by the large thermal mass of the instrument simulator which modulated the net heat load to the evaporator, and the vertical radiator/condenser which induced a variable gravitational pressure head. Furthermore, causes and effects of the contributing factors to flow and temperature oscillations intermingled.

0000↗

Automation and Upgrade of Thermal System for Large 38-Year-Young Test Facility

The Goddard Space Flight Center's Space Environment Simulator (SES) facility has been improved by the upgrade of its thermal control hardware and software. This paper describes the preliminary design process, funding constraints, and the proposed enhancements as well as the installation details, the testing difficulties, and the overall benefits realized from this upgrade. The preliminary design process was discussed in a paper presented in October 1996 and will be recapped in this paper to provide background and comparison to actual product. Structuring the procurement process to match the funding constraints allowed Goddard to enhance its capabilities in an environment of reduced budgets. The installation of the new system into a location that has been occupied for over 38 years was one of the driving design factors for the size of the equipment. The installation was completed on time and under budget. The tuning of the automatic sequences for the new thermal system to the existing shroud system required more time and ultimately presented some setbacks to the vendor and the final completion of the system. However, the end product and its benefits to Goddard's thermal vacuum test portfolio will carry the usefulness of this facility well into the next century.

Webb, Andrew T.↗

Automation and Upgrade of Thermal System for Large 38-Year Young Test Facility

The Goddard Space Flight Center's Space Environment Simulator (SES) facility has been improved by the upgrade of its thermal control hardware and software. This paper describes the preliminary design process, funding constraints, and the proposed enhancements as well as the installation details, the testing difficulties, and the overall benefits realized from this upgrade. The preliminary design process was discussed in a paper presented in October 1996 and will be recapped in this paper to provide background and comparison to actual product. Structuring the procurement process to match the funding constraints allowed Goddard to enhance its capabilities in an environment of reduced budgets. The installation of the new system into a location that has been occupied for over 38-years was one of the driving design factors for the size of the equipment. The installation was completed on-time and under budget. The tuning of the automatic sequences for the new thermal system to the existing shroud system required more time and ultimately presented some setbacks to the vendor and the final completion of the system. However, the end product and its benefits to Goddard's thermal vacuum test portfolio will carry the usefulness of this facility well into the next century.

Webb, Andrew↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

High-temperature electric stator

Thermal vacuum tests are conducted on high-temperature stator without a rotor. Electrical characteristics remained satisfactory during tests, insulation improved slightly, and conductor resistance remained constant. The assembly included a bore seal for hermetically sealing the stator from the rotor cavity.

Kueser, P.↗

The temporal characteristics of the terrestrial radiation belt

The terrestrial radiation belt effects on the detectors in the Wisconsin equipment are considered. The lowest dark count rate observed in orbit, compared with that measured in the thermal vacuum test on the ground, shows no measurable difference for the solar blind ASCOP 541-F photomultiplier tubes while the EMI-6256B tubes show an increase in minimum dark count of a factor of from 20 to 150 times that observed on the ground. All instruments are perturbed when in the South Atlantic anomaly, but the EMI tubes are by far the most sensitive to it. Indeed, the effect never goes away.

Mcnall, J. F.↗

Contamination threats to critical surfaces from handling and storage practices.

Review of the procedures and results of a program designed to remove the threat of sources of molecular and particulate contamination of critical optical, electrical, and mechanical elements in spacecraft. The results of recent contamination-probing thermal-vacuum tests indicate that some of the materials and practices commonly used to protect critical surfaces from molecular or particulate contamination can themselves represent significant threats. These contamination sources include clean-room and clean-tent materials, gloves, tissues, and covering or packaging materials. Mass and infrared spectral analyses of these materials and the environments and instruments exposed to them show that the contaminants are mostly plasticizers, slip or antistatic agents, and binders used in the manufacture of these products. Products of particular threat include vinyl gloves, boots, clean-tent walls, and some polyethylene sheets and bags. Techniques for reducing these threats are discussed.

Poehlmann, H. C.↗

Mechanical component screening for scanner

The critical mechanical components of the scan mirror mechanism are described and their evaluation and screening procedures are discussed. A bumper/damper unit is used in the design to reverse motion of the mirror and effect scan and retrace cycles. A wear evaluation was conducted on the bumper impact surfaces that established nylon 6-10 as an acceptable material. The elastomeric dampers were subjected to thermal vacuum tests for condensables and outgassing as well as parametric life tests. The flexure pivots that support the mirror were tested to establish a curve of stress plotted as a function of cycles to failure for rotational operation. The pivots met the life requirement of 150,000,000 cycles at a + or - 2.9 deg amplitude during fatigue testing. Screening procedures were established for dampers and flexure pivots to obtain flight quality components.

Olson, J. L.↗

Current European developments in solar paddle drives

The European Space Research and Technology Centre (ESTEC) is sponsoring the development of a number of critical spacecraft hardware items. The hardware under development includes two competing solar paddle drives which are being produced to similar specifications. Three mechanisms of each type are being produced and will undergo thermal vacuum testing. All mechanisms have lead lubricated bearings.

Bentall, R. H.↗

The Atmosphere Explorer-C spacecraft temperature alarm

An instrument designed to fly on the Atmosphere Explorer-C (AE-C) spacecraft is described which is to provide a thermal measurement indicative of the temperature of the low mass elements, thus providing information to assist in the decision process regarding real time perigee maneuvers. Also described is the method of achievement of two additional design goals, an indication of the altitude at which aerodynamic heating begins to take place, and a quantitative measure of the aerodynamic flux. Provision of such an instrument obviated the need for very costly and very difficult simulation of the aerodynamic heating during thermal vacuum testing.

Young, E. W.↗

The outgassing and pressures in a spacecraft

The parameters that affect the internal pressure, i.e., the effective flow conductances of the internal volumes, their time constants and outgassing sources are examined. The objectives are to estimate the internal pressure of the spacecraft during the first several days after launch and to evaluate the responses of the volume to external pressure variations. The general approach followed is to (1) establish the various flow paths from a compartment to the low pressure regions; (2) calculate the conductances and combined effective conductances for these paths; (3) estimate the material outgassing rates in each volume from a general knowledge of materials used in the spacecraft; and (4) establish the pressure vs time in these compartments. The results of these techniques have been compared with experimental results obtained during thermal vacuum test of the spacecraft.

Scialdone, J. J.↗

LANDSAT-2 launch and flight activation. Launch through orbit 50 and orbit adjust operation

The results of the analysis conducted on the telemetry data from the prelaunch, launch, and flight activation phases of LANDSAT-2 spacecraft are presented according to subsystems and interrelationships that exist between subsystems. Subsystem characteristics are included along with the flight evaluation results. Flight data are compared to baseline data established at the 20 C plateau during thermal vacuum testing of the spacecraft. Evaluation guidelines are derived from the specifications developed from the LANDSAT program objectives: (1) acquisition of multispectral images of the surface of the earth; and (2) use of the LANDSAT-2 receiving, frequency translating, and transmitting equipment as a relay system to gather data from fixed earth-based sensor platforms which are operated by individual investigators. Data are presented on the first 50 orbits of the spacecraft.

Source record↗