Overview of NASA Lewis Research Center free-piston Stirling engine activities

A generic free-piston Stirling technology project is being conducted to develop technologies generic to both space power and terrestrial heat pump applications in a cooperative, cost-shared effort. The generic technology effort includes extensive parametric testing of a 1 kW free-piston Stirling engine (RE-1000), development of a free-piston Stirling performance computer code, design and fabrication under contract of a hydraulic output modification for RE-1000 engine tests, and a 1000-hour endurance test, under contract, of a 3 kWe free-piston Stirling/alternator engine. A newly initiated space power technology feasibility demonstration effort addresses the capability of scaling a free-piston Stirling/alternator system to about 25 kWe; developing thermodynamic cycle efficiency or equal to 70 percent of Carnot at temperature ratios in the order of 1.5 to 2.0; achieving a power conversion unit specific weight of 6 kg/kWe; operating with noncontacting gas bearings; and dynamically balancing the system. Planned engine and component design and test efforts are described.

Slaby, J. G.↗

Overview of NASA Lewis Research Center free-piston Stirling engine activities

A generic free-piston Stirling technology project is being conducted to develop technologies generic to both space power and terrestrial heat pump applications in a cooperative, cost-shared effort. The generic technology effort includes extensive parametric testing of a 1 kW free-piston Stirling engine (RE-1000), development of a free-piston Stirling performance computer code, design and fabrication under contract of a hydraulic output modification for RE-1000 engine tests, and a 1000-hour endurance test, under contract, of a 3 kWe free-piston Stirling/alternator engine. A newly initiated space power technology feasibility demonstration effort addresses the capability of scaling a free-piston Stirling/alternator system to about 25 kWe; developing thermodynamic cycle efficiency or equal to 70 percent of Carnot at temperature ratios in the order of 1.5 to 2.0; achieving a power conversion unit specific weight of 6 kg/kWe; operating with noncontacting gas bearings; and dynamically balancing the system. Planned engine and component design and test efforts are described.

Slaby, J. G.↗

A cloud, precipitation and electrification modeling effort for COHMEX

In mid-1987, the Modeling Group of the Institute of Atmospheric Sciences (IAS) began to simulate and analyze cloud runs that were made during the Cooperative Huntsville Meteorological Experiment (COHMEX) Project and later. The cloud model was run nearly every day during the summer 1986 COHMEX Project. The Modeling Group was then funded to analyze the results, make further modeling tests, and help explain the precipitation processes in the Southeastern United States. The main science objectives of COHMEX were: (1) to observe the prestorm environment and understand the physical mechanisms leading to the formation of small convective systems and processes controlling the production of precipitation; (2) to describe the structure of small convective systems producing precipitation including the large and small scale events in the environment surrounding the developing and mature convective system; (3) to understand the interrelationships between electrical activity within the convective system and the process of precipitation; and (4) to develop and test numerical models describing the boundary layer, tropospheric, and cloud scale thermodynamics and dynamics associated with small convective systems. The latter three of these objectives were addressed by the modeling activities of the IAS. A series of cloud modes were used to simulate the clouds that formed during the operational project. The primary models used to date on the project were a two dimensional bulk water model, a two dimensional electrical model, and to a lesser extent, a two dimensional detailed microphysical cloud model. All of the models are based on fully interacting microphysics, dynamics, thermodynamics, and electrical equations. Only the 20 July 1986 case was analyzed in detail, although all of the cases run during the summer were analyzed as to how well they did in predicting the characteristics of the convection for that day.

Orville, Harold D.↗

Testing of an Integrated Reactor Core Simulator and Power Conversion System with Simulated Reactivity Feedback

A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, Ohio. This is a closed-cycle system that incorporates an electrically heated reactor core module, turboalternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.

Bragg-Sitton, Shannon M.↗

Testing of an Integrated Reactor Core Simulator and Power Conversion System with Simulated Reactivity Feedback

A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, OH. This is a closed-cycle system that incorporates an electrically heated reactor core module, turbo alternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.

Bragg-Sitton, Shannon M.↗

Interannual Variability in Surface LW Fluxes Over the Tropical Oceans As Seen in ISCCP-FD and GEWEX SRB Data Sets

One notable aspect of Earth s climate is that although the planet appears to be very close to radiative balance at top-of-atmosphere (TOA), the atmosphere itself and underlying surface are not. Profound exchanges of energy between the atmosphere and oceans, land and cryosphere occur over a range of time scales. Recent evidence from broadband satellite measurements suggests that even these TOA fluxes contain some detectable variations. Our ability to measure and reconstruct radiative fluxes at the surface and at the top of atmosphere is improving rapidly. In this work we will evaluate two recently released estimates of radiative fluxes, focusing primarily on surface estimates. The International Satellite Cloud Climatology Project FD radiative flux profiles are available from mid-1 983 to near present and have been constructed by driving the radiative transfer physics from the Goddard Institute for Space Studies (GISS) global model with ISCCP clouds and TOVS (TIROS Operational Vertical Sounder)thermodynamic profiles. Fu!l and clear sky SW and LW fluxes are produced. A similar product from the NASA/GEWEX Surface Radiation Budget Project using different radiative flux codes and thermodynamics from the NAS/Goddard Earth Observing System (GEOS-1) assimilation model makes a similar calculation of surface fluxes. However this data set currently extends only through 1995. Significant differences in both interannual variability as well as trends are found between among these data sets. For radiative fluxes these differences are traced to TOVS thermodynamic soundings used to drive the ISCCP-FD calculations. Errors in near surface temperature and precipitable water cascade into ISCCP upward and downward IR flux components, demonstrably affecting interannual variability. Revised estimates of clear-sky fluxes over ocean are made using statistical algorithms and water vapor from the (SSM/I) Special Sensor Microwave Imager. These calculations show strong near-surface water vapor feedback over the tropical oceans in association with SST changes. However, it is also shown that ISCCP longwave cloud forcing, common to both the ISCCP-FD and GEWEX SRB retrievals, is the main driver of a long-term decrease in net LW flux to the surface during the near-20 year period covered by these revised estimates.

Robertson, F. R.↗

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

Thermodynamic Effect of Platinum Addition to beta-NiAl: An Initial Investigation

An initial investigation was conducted to determine the effect of platinum addition on the activities of aluminum and nickel in beta-NiAl(Pt) over the temperature range 1354 to 1692 K. These measurements were made with a multiple effusion-cell configured mass spectrometer (multi-cell KEMS). The results of this study show that Pt additions act to decreased alpha(Al) and increased the alpha(Ni) in beta-NiAl(Pt) for constant X(sub Ni)/X(sub Al) approx. = 1.13, while at constant X(sub Al) the affect of Pt on Al is greatly reduced. The measured partial enthalpies of mixing indicate Al-atoms have a strong self interaction while Ni- and Pt-atoms in have similar interactions with Al-atoms. Conversely the binding of Ni-atoms in beta-NiAl decreases with Pt addition independent of Al concentration. These initial results prove the technique can be applied to the Ni-Al-Pt system but more activity measurements are required to fully understand the thermodynamics of this system and how Pt additions improved the scaling behavior of nickel-based superalloys. In addition, with the choice of a suitable oxide material for the effusion-cell, the "closed" isothermal nature of the effusion-cell allows the direct investigation of an alloy-oxide equilibrium which resembles the "local-equilibrium" description of the metal-scale interface observed during high temperature oxidation. It is proposed that with an Al(l) + Al2O3(s) experimental reference state together with the route measurement of the relative partial-pressures of Al(g) and Al2O(g) allows the activities of O and Al2O3 to be determined along with the activities of Ni and Al. These measurements provide a direct method of investigating the thermodynamics of the metal-scale interface of a TGO-scale.

Source record↗

An Analysis of the Automated Meteorological Profiling System Low Resolution Flight Element

A study was conducted to determine the quality of thermodynamic and wind data measured by or derived from the Low Resolution Flight Element (LRFE) of the Automated Meteorological Profiling System (AMPS). The AMPS LRFE replaced the Meteorological Sounding System (MSS), which was used to provide vertical profiles of thermodynamic and low-resolution wind data in support of spacecraft launch operations at the Cape Canaveral Air Force Station (CCAFS) and NASA Kennedy Space Center (KSC), Florida. Air temperature, relative humidity, and height, which are directly measured by the LRFE, are used to derive air pressure and density. Test flights were conducted where an LRFE sonde and an MSS sonde were attached to the same balloon and the two profiles were compared. MSS data was used as the standard reference data. The objective of the thermodynamic testing was to determine a) if the LRFE met Space Shuttle Program (SSP) accuracy requirements outlined in the Space Shuttle Launch and Landing Program Requirements Document (PRD) and/or, b) if the LRFE met or exceeded MSS data quality. AMPS uses the Global Positioning System (GPS) to determine wind speed and direction. In order to provide a basis for comparison, either an AMPS High Resolution Flight Element (HRFE) or a radar tracked Jimsphere was released simultaneously with each AMPS LRFE at CCAFS. The goal of these tests was to determine if the LRFE wind data met the requirement for low-resolution wind data defined in the Shuttle PRD. Based on the available data, the LRFE is shown to produce more consistent thermodynamic measurements than the MSS. The LRFE is also shown to meet the Shuttle PRD requirements for low resolution wind data.

Leahy, Frank B.↗

Thermodynamics of Aqueous Organic Sulfur Compounds: A Key to the Organic Geochemistry of Hydrothermal Systems?

Hydrothermal environments are locations of varied geochemistry due to the disequilibrium between vent fluids and seawater. The disequilibrium geochemistry has been hypothesized to include reactions to synthesize organic compounds. Observations of the organic geochemistry of hydrothermal vent sites has received little attention. Experimental simulations of these environments, however, indicate that organic compounds may have difficulty forming in a purely aqueous environment. On the other hand, thiols. thioesters and disulfides have been implicated as reaction intermediates between CO or CO2 in experiments of carbon reduction in hydrothermal environments as well as in a variety of biological processes and other abiotic reactions (Wachtershauser, 1990, OLEB 20, 173; Heinen and Lauwers, 1996, OLEB 26, 13 1, Huber and Wachtershauser, 1997, Science 276, 245; Russell et al., 1998, in Thermophiles: The keys to molecular evolution and the origin of life?). The reduction of CO2 to thiols, for example, is observed using the FeS-H2S/FeS2 couple to provide the reducing power (see Schoonen et al., 1999, OLEB 29, 5). In addition, the enzyme involved in final stage of methanogenesis, coenzyme-M, is itself a thiol. Thus, organic sulfur compounds may hold the key to the organic chemistry leading to the origin of life at high temperatures. Understanding the biochemical processes of microorganisms that can live to temperatures at least as high as 113 C (Blochl et al., 1996, Extremophiles 1, 14) requires knowledge of the properties of the chemical reactions involved. In order to assess the role of aqueous organic sulfur compounds in hydrothermal organic geochemistry, we have been attempting to determine their thermodynamic properties. We have culled the literature to obtain the properties of organic sulfur compounds. We are able to calculate a number of essential properties, such as free energies of formation, from solubility data available in the literature together with standard properties of organic sulfur gases. However, a number of the properties for aqueous organic sulfur compounds have not been experimentally determined. Furthermore, most of thermodynamic data that are available are for 25 C and 1 bar. In order to determine reaction properties to temperatures and pressures appropriate to the hydrothermal conditions in which thermophilic organisms actually live, we use equations of state developed by Helgeson and co-workers (Helgeson et al., 1981, AJS 281, 1249). A key piece of information needed to go up in temperature is the partial molal heat capacity, which is one of the properties for which experimental data are unavailable for nearly all organic sulfur compounds. We have used correlation methods to determine the partial molal heat capacities and volumes of many organic solutes. These estimates allow us to asses the role of organic sulfur compounds during the reduction of carbon in hydrothermal settings. We will present these data, along with examples of the thermodynamic properties of reactions involving aqueous organic sulfur compounds.

Schulte, Mitchell↗

Improving Boundary Layer Data Assimilation Using Observation Data from Multiple Observing Systems in the NASA GEOS System

The Planetary Boundary Layer (PBL) is a complex interface that mediates energy and moisture exchanges between the Earth’s surface and atmosphere. Accurate simulation and observation of PBL characteristics, such as PBL height and thermodynamic structure, have proven to be a challenge. In our latest efforts, we have focused on improving PBL thermodynamic structure using data from multiple observing systems in the Goddard Earth Observing System (GEOS), developed by the NASA Global Modeling and Assimilation Office (GMAO). We present strategies and results from assimilating PBL height data derived from radiosondes, GNSS radio occultation, space-based lidar (CALIPSO, CATS, IceSat-2), ground-based lidar (MPLNET), and radar wind profilers, including a novel global PBL height analysis dataset. We also discuss the impacts of better representing capping inversions by using PBL height data together with other observations in GEOS through adjustments to the background error covariance. Long-term statistics of the impact of assimilating and utilizing PBL height data in GEOS are presented. In addition, we explore an innovative approach to assimilate GNSS-RO refractivity data in the lower troposphere.

Eun-Gyeong Yang↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan- stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to provide operating conditions such that ice would accrete in either the fan-stator through the inlet guide vane region of the compression system or within the first stator of the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDESMELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet-bulb temperature thresholds were applied for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applied to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions. The goal of this study is to show that the computational process developed on earlier engine icing tests can be used to provide an icing risk assessment in adiabatic regions for other engines.

Turbofan engine↗

Metabolic Reactions among Organic Sulfur Compounds

Sulfur is central to the metabolisms of many organisms that inhabit extreme environments. Numerous authors have addressed the energy available from a variety of inorganic sulfur redox pairs. Less attention has been paid, however, to the energy required or gained from metabolic reactions among organic sulfur compounds. Work in this area has focused on the oxidation of alkyl sulfide or disulfide to thiol and formaldehyde, e.g. (CH3)2S + H2O yields CH3SH + HCHO + H2, eventually resulting in the formation of CO2 and SO4(-2). It is also found that reactions among thiols and disulfides may help control redox disequilibria between the cytoplasm and the periplasm. Building on our earlier efforts for thiols, we have compiled and estimated thermodynamic properties for alkyl sulfides. We are investigating metabolic reactions among various sulfur compounds in a variety of extreme environments, ranging from sea floor hydrothermal systems to organic-rich sludge. Using thermodynamic data and the revised HKF equation of state, along with constraints imposed by the geochemical environments sulfur-metabolizing organisms inhabit, we are able to calculate the amount of energy available to these organisms.

Schulte, M.↗

Study of the application of hydrogen fuel to long-range subsonic transport aircraft. Volume 1: Summary

The feasibility of using liquid hydrogen as fuel in advanced designs of long range, subsonic transport aircraft is assessed. Both passenger and cargo type aircraft are investigated. Comparisons of physical, performance, and economic parameters of the LH2 fueled designs with conventionally fueled aircraft are presented. Design studies are conducted to determine appropriate characteristics for the hydrogen related systems required on board the aircraft. These studies included consideration of material, structural, and thermodynamic requirements of the cryogenic fuel tanks and fuel systems with the structural support and thermal protection systems.

Brewer, G. D.↗

Hydrothermal systems as environments for the emergence of life

Analysis of the chemical disequilibrium provided by the mixing of hydrothermal fluids and seawater in present-day systems indicates that organic synthesis from CO2 or carbonic acid is thermodynamically favoured in the conditions in which hyperthermophilic microorganisms are known to live. These organisms lower the Gibbs free energy of the chemical mixture by synthesizing many of the components of their cells. Primary productivity is enormous in hydrothermal systems because it depends only on catalysis of thermodynamically favourable, exergonic reactions. It follows that hydrothermal systems may be the most favourable environments for life on Earth. This fact makes hydrothermal systems logical candidates for the location of the emergence of life, a speculation that is supported by genetic evidence that modern hyperthermophilic organisms are closer to a common ancestor than any other forms of life. The presence of hydrothermal systems on the early Earth would correspond to the presence of liquid water. Evidence that hydrothermal systems existed early in the history of Mars raises the possibility that life may have emerged on Mars as well. Redox reactions between water and rock establish the potential for organic synthesis in and around hydrothermal systems. Therefore, the single most important parameter for modelling the geochemical emergence of life on the early Earth or Mars is the composition of the rock which hosts the hydrothermal system.

Non-NASA Center↗