Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Frequency-Bessel Transform Method for Effective Imaging of Higher-Mode Rayleigh Dispersion Curves From Ambient Seismic Noise Data

It has been widely recognized that the cross-correlation function of ambient seismic noise data recorded at two stations approximates to the part of Greens function between two stations. Therefore, the cross-correlation function should include higher modes, aside from the fundamental mode. However, the problem of measuring or extracting overtones from ambient seismic noise data remains. In this paper, we propose the frequency-Bessel transform method (F-J method) for extracting the dispersion curves of higher modes from ambient seismic noise data. We then assess the validity, accuracy, and applicability of the F-J method by conducting extensive numerical simulations and processing the observed ambient seismic noise data of the USArray. As demonstrated in this study, the F-J method is a convenient, practical, and accurate method for extracting the dispersion curves of multimodes from ambient seismic noise data and therefore has significant potentiality in the field of ambient seismic noise tomography.

58 GEOSCIENCES↗

Region-of-interest diffuse optical tomography system

Diffuse optical tomography (DOT) using near-infrared light is a promising tool for non-invasive imaging of deep tissue. This technique is capable of quantitative reconstruction of absorption (μ{sub a}) and scattering coefficient (μ{sub s}) inhomogeneities in the tissue. The rationale for reconstructing the optical property map is that the absorption coefficient variation provides diagnostic information about metabolic and disease states of the tissue. The aim of DOT is to reconstruct the internal tissue cross section with good spatial resolution and contrast from noisy measurements non-invasively. We develop a region-of-interest scanning system based on DOT principles. Modulated light is injected into the phantom/tissue through one of the four light emitting diode sources. The light traversing through the tissue gets partially absorbed and scattered multiple times. The intensity and phase of the exiting light are measured using a set of photodetectors. The light transport through a tissue is diffusive in nature and is modeled using radiative transfer equation. However, a simplified model based on diffusion equation (DE) can be used if the system satisfies following conditions: (a) the optical parameter of the inhomogeneity is close to the optical property of the background, and (b) μ{sub s} of the medium is much greater than μ{sub a} (μ{sub s} > > μ{sub a}). The light transport through a highly scattering tissue satisfies both of these conditions. A discrete version of DE based on finite element method is used for solving the inverse problem. The depth of probing light inside the tissue depends on the wavelength of light, absorption, and scattering coefficients of the medium and the separation between the source and detector locations. Extensive simulation studies have been carried out and the results are validated using two sets of experimental measurements. The utility of the system can be further improved by using multiple wavelength light sources. In such a scheme, the spectroscopic variation of absorption coefficient in the tissue can be used to arrive at the oxygenation changes in the tissue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small fields: Nonequilibrium radiation dosimetry

Advances in radiation treatment with beamlet-based intensity modulation, image-guided radiation therapy, and stereotactic radiosurgery (including specialized equipments like CyberKnife, Gamma Knife, tomotherapy, and high-resolution multileaf collimating systems) have resulted in the use of reduced treatment fields to a subcentimeter scale. Compared to the traditional radiotherapy with fields {>=}4x4 cm{sup 2}, this can result in significant uncertainty in the accuracy of clinical dosimetry. The dosimetry of small fields is challenging due to nonequilibrium conditions created as a consequence of the secondary electron track lengths and the source size projected through the collimating system that are comparable to the treatment field size. It is further complicated by the prolonged electron tracks in the presence of low-density inhomogeneities. Also, radiation detectors introduced into such fields usually perturb the level of disequilibrium. Hence, the dosimetric accuracy previously achieved for standard radiotherapy applications is at risk for both absolute and relative dose determination. This article summarizes the present knowledge and gives an insight into the future procedures to handle the nonequilibrium radiation dosimetry problems. It is anticipated that new miniature detectors with controlled perturbations and corrections will be available to meet the demand for accurate measurements. It is also expected that the Monte Carlo techniques will increasingly be used in assessing the accuracy, verification, and calculation of dose, and will aid perturbation calculations of detectors used in small and highly conformal radiation beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

Few layer graphene synthesis on transition metal ferrite catalysts

Development of cheap, green and up scalable production methods for graphene is one of the most challenging problems in its manufacture on an industrial scale. We report here a large scale substrate-free fluidized bed catalytic chemical vapour deposition (FB-CCVD) process for few layer graphene (FLG) powder production that uses a crystalline oxide catalyst of the general formula A(x)B(3-x)O(4), wherein the FLG layer thickness and domain sizes can be varied. A and B can be chosen from a list of transition elements including Co, Fe, Ni, Mn, Cu and Zn. The best results in terms of activity and selectivity are obtained for the CoxFe3-xO4 system. We also investigated the reaction mechanism using in situ EXAFS and Raman spectroscopy, and electron tomography. Since FB-CCVD processes are already used for industrial scale production of carbon nanotubes, this process should enable the large scale production of free standing FLG in the near future.

Bacsa, Revathi R.↗

SU-F-J-63: Abdominal Diameter Changes in Children During Volumetric Modulated Arc Therapy (VMAT): Is Re-Planning Needed?

Purpose: To investigate the dosimetric impact of daily changes in patient’s diameter, due to weight gain/loss and air in the bowel, based on CBCT information during radiotherapy treatment of pediatric abdominal tumors. Methods: 10 pediatric patients with neuroblastoma (n=6) and Wilms’ (n=4) tumors were included. Available CBCTs were affinely registered to the planning CT for daily set-up variations corrections. A density override approach assigning air-density to the random air pockets and water-density to the remaining anatomy was used to determine the CBCT and CT dose. Clinical VMAT plans, with a PTV prescribed dose ranging between (14.4- 36) Gy, were re-optimized on the density override CT and re-calculated on each CBCT. Dose-volume statistics of the PTV and kidneys, delineated on each CBCT, were used to compare the daily and cumulative CBCT dose with the reference CT dose. Results: The average patient diameter variation was (0.5 ± 0.7) cm (maximum daily difference of 2.3 cm). The average PTV mean dose difference (MDD) between the CT and the cumulative CBCT plans was (0.1 ± 1.1) % (maximum daily MDD of 2%). A reduction in target coverage up to 3% and 7% was observed for the cumulative and daily CBCT plans, respectively. The average kidneys’ cumulative MDD was (−2.7 ± 3.6) % (maximum daily MDD of −12%), corresponding to an overdosage. Conclusion: Due to patient’s diameter changes, a target underdosage was assessed. Given the high local tumor control of neuroblastoma and Wilms’ diseases, the need of re-planning might be discarded. However, the assessed kidneys overdosage could represent a problem when the normal tissue tolerance is reached. The necessity of re-planning should then be considered to reduce the risk of long-term renal complications. Due to the poor softtissue contrast on CBCT, MRI-guidance is required to obtain a better assessment of the accumulated dose on the remaining OARs.

60 APPLIED LIFE SCIENCES↗

SU-D-206-02: Evaluation of Partial Storage of the System Matrix for Cone Beam Computed Tomography Using a GPU Platform

Purpose: Iterative reconstruction algorithms in computed tomography (CT) require a fast method for computing the intersections between the photons’ trajectories and the object, also called ray-tracing or system matrix computation. This work evaluates different ways to store the system matrix, aiming to reconstruct dense image grids in reasonable time. Methods: We propose an optimized implementation of the Siddon’s algorithm using graphics processing units (GPUs) with a novel data storage scheme. The algorithm computes a part of the system matrix on demand, typically, for one projection angle. The proposed method was enhanced with accelerating options: storage of larger subsets of the system matrix, systematic reuse of data via geometric symmetries, an arithmetic-rich parallel code and code configuration via machine learning. It was tested on geometries mimicking a cone beam CT acquisition of a human head. To realistically assess the execution time, the ray-tracing routines were integrated into a regularized Poisson-based reconstruction algorithm. The proposed scheme was also compared to a different approach, where the system matrix is fully pre-computed and loaded at reconstruction time. Results: Fast ray-tracing of realistic acquisition geometries, which often lack spatial symmetry properties, was enabled via the proposed method. Ray-tracing interleaved with projection and backprojection operations required significant additional time. In most cases, ray-tracing was shown to use about 66 % of the total reconstruction time. In absolute terms, tracing times varied from 3.6 s to 7.5 min, depending on the problem size. The presence of geometrical symmetries allowed for non-negligible ray-tracing and reconstruction time reduction. Arithmetic-rich parallel code and machine learning permitted a modest reconstruction time reduction, in the order of 1 %. Conclusion: Partial system matrix storage permitted the reconstruction of higher 3D image grid sizes and larger projection datasets at the cost of additional time, when compared to the fully pre-computed approach. This work was supported in part by the Fonds de recherche du Quebec - Nature et technologies (FRQ-NT). The authors acknowledge partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (Grant No. 432290).

60 APPLIED LIFE SCIENCES↗

Single-shot tomographic movies of evolving light-velocity objects

Tomography—cross-sectional imaging based on measuring radiation transmitted through an object along different directions—enables non-invasive imaging of hidden stationary objects, such as internal bodily organs, from their sequentially measured projections. Here we adapt tomographic methods to visualize—in one laser shot—the instantaneous structure and evolution of a laser-induced object propagating through a transparent Kerr medium. We reconstruct ‘movies’ of a laser pulse’s diffraction, self-focusing and filamentation from phase ‘streaks’ imprinted onto probe pulses that cross the main pulse’s path simultaneously at different angles. Multiple probes are generated and detected compactly and simply, making the system robust, easy to align and adaptable to many problems. Our technique could potentially visualize, for example, plasma wakefield accelerators, optical rogue waves or fast ignitor pulses, light-velocity objects, whose detailed space–time dynamics are known only through intensive computer simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CONRAD—A software framework for cone-beam imaging in radiology

Purpose: In the community of x-ray imaging, there is a multitude of tools and applications that are used in scientific practice. Many of these tools are proprietary and can only be used within a certain lab. Often the same algorithm is implemented multiple times by different groups in order to enable comparison. In an effort to tackle this problem, the authors created CONRAD, a software framework that provides many of the tools that are required to simulate basic processes in x-ray imaging and perform image reconstruction with consideration of nonlinear physical effects.Methods: CONRAD is a Java-based state-of-the-art software platform with extensive documentation. It is based on platform-independent technologies. Special libraries offer access to hardware acceleration such as OpenCL. There is an easy-to-use interface for parallel processing. The software package includes different simulation tools that are able to generate up to 4D projection and volume data and respective vector motion fields. Well known reconstruction algorithms such as FBP, DBP, and ART are included. All algorithms in the package are referenced to a scientific source.Results: A total of 13 different phantoms and 30 processing steps have already been integrated into the platform at the time of writing. The platform comprises 74.000 nonblank lines of code out of which 19% are used for documentation. The software package is available for download at http://conrad.stanford.edu. To demonstrate the use of the package, the authors reconstructed images from two different scanners, a table top system and a clinical C-arm system. Runtimes were evaluated using the RabbitCT platform and demonstrate state-of-the-art runtimes with 2.5 s for the 256 problem size and 12.4 s for the 512 problem size.Conclusions: As a common software framework, CONRAD enables the medical physics community to share algorithms and develop new ideas. In particular this offers new opportunities for scientific collaboration and quantitative performance comparison between the methods of different groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pre-conditioned BFGS-based uncertainty quantification in elastic full-waveform inversion

SUMMARY Full-waveform inversion has become an essential technique for mapping geophysical subsurface structures. However, proper uncertainty quantification is often lacking in current applications. In theory, uncertainty quantification is related to the inverse Hessian (or the posterior covariance matrix). Even for common geophysical inverse problems its calculation is beyond the computational and storage capacities of the largest high-performance computing systems. In this study, we amend the Broyden–Fletcher–Goldfarb–Shanno (BFGS) algorithm to perform uncertainty quantification for large-scale applications. For seismic inverse problems, the limited-memory BFGS (L-BFGS) method prevails as the most efficient quasi-Newton method. We aim to augment it further to obtain an approximate inverse Hessian for uncertainty quantification in FWI. To facilitate retrieval of the inverse Hessian, we combine BFGS (essentially a full-history L-BFGS) with randomized singular value decomposition to determine a low-rank approximation of the inverse Hessian. Setting the rank number equal to the number of iterations makes this solution efficient and memory-affordable even for large-scale problems. Furthermore, based on the Gauss–Newton method, we formulate different initial, diagonal Hessian matrices as pre-conditioners for the inverse scheme and compare their performances in elastic FWI applications. We highlight our approach with the elastic Marmousi benchmark model, demonstrating the applicability of pre-conditioned BFGS for large-scale FWI and uncertainty quantification.

58 GEOSCIENCES↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Denoising of polychromatic CT images based on their own noise properties

Purpose: Because of high diagnostic accuracy and fast scan time, computed tomography (CT) has been widely used in various clinical applications. Since the CT scan introduces radiation exposure to patients, however, dose reduction has recently been recognized as an important issue in CT imaging. However, low-dose CT causes an increase of noise in the image and thereby deteriorates the accuracy of diagnosis. In this paper, the authors develop an efficient denoising algorithm for low-dose CT images obtained using a polychromatic x-ray source. The algorithm is based on two steps: (i) estimation of space variant noise statistics, which are uniquely determined according to the system geometry and scanned object, and (ii) subsequent novel conversion of the estimated noise to Gaussian noise so that an existing high performance Gaussian noise filtering algorithm can be directly applied to CT images with non-Gaussian noise. Methods: For efficient polychromatic CT image denoising, the authors first reconstruct an image with the iterative maximum-likelihood polychromatic algorithm for CT to alleviate the beam-hardening problem. We then estimate the space-variant noise variance distribution on the image domain. Since there are many high performance denoising algorithms available for the Gaussian noise, image denoising can become much more efficient if they can be used. Hence, the authors propose a novel conversion scheme to transform the estimated space-variant noise to near Gaussian noise. In the suggested scheme, the authors first convert the image so that its mean and variance can have a linear relationship, and then produce a Gaussian image via variance stabilizing transform. The authors then apply a block matching 4D algorithm that is optimized for noise reduction of the Gaussian image, and reconvert the result to obtain a final denoised image. To examine the performance of the proposed method, an XCAT phantom simulation and a physical phantom experiment were conducted. Results: Both simulation and experimental results show that, unlike the existing denoising algorithms, the proposed algorithm can effectively reduce the noise over the whole region of CT images while preventing degradation of image resolution. Conclusions: To effectively denoise polychromatic low-dose CT images, a novel denoising algorithm is proposed. Because this algorithm is based on the noise statistics of a reconstructed polychromatic CT image, the spatially varying noise on the image is effectively reduced so that the denoised image will have homogeneous quality over the image domain. Through a simulation and a real experiment, it is verified that the proposed algorithm can deliver considerably better performance compared to the existing denoising algorithms.

60 APPLIED LIFE SCIENCES↗

Detecting an underground tunnel by applying joint traveltime and waveform inversion

Underground tunnel and void detection is a challenging geophysical problem, and many methods have been proposed. Seismic techniques are promising because of the large seismic velocity contrasts between the air-filled void and the surrounding sediment and concrete. We apply a joint seismic traveltime and waveform inversion method to image a buried tunnel with concrete walls and a void space inside. The joint inversion images the top of the concrete tunnel as a high-velocity anomaly and the void space as a low-velocity anomaly. The location of the velocity anomalies predicted by the method agrees with the known location of the tunnel. As a comparison, the stand-alone full waveform inversion is also applied to the data. The first-arrival traveltime tomography shows weak nonlinearity but fails to image the hidden low-velocity layer. Full waveform inversion is able to image complex near-surface structures, but fitting waveforms may not honor the traveltime fit, especially when the data contain noise. Synthetic and real data tests show that the joint inversion method retains the advantages of both traveltime inversion and full waveform inversion and overcomes their respective drawbacks at the same time. The field example shows the joint inversion provides a better reconstruction of the high-velocity feature representing the top of the concrete wall in terms of its magnitude and location.

58 GEOSCIENCES↗

Recovery and normalization of triple coincidences in PET

Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the authors’ method increased peak NEC rates of the scanner by 26.6% and 32% for mouse- and rat-sized objects, respectively. This increase in NEC-rate performance was also reflected in the image-quality metrics. Images reconstructed using double and triple coincidences recovered using their method had better signal-to-noise ratio than those obtained using only double coincidences, while preserving spatial resolution and contrast. Distribution of triple coincidences using an equal-weighting scheme increased apparent system sensitivity but degraded image quality. The performance boost provided by the inclusion of triple coincidences using their method allowed to reduce the acquisition time of standard imaging procedures by up to ∼25%. Conclusions: Recovering triple coincidences with the proposed method can effectively increase the sensitivity of current clinical and preclinical PET systems without compromising other parameters like spatial resolution or contrast.

60 APPLIED LIFE SCIENCES↗

Analytical, experimental, and Monte Carlo system response matrix for pinhole SPECT reconstruction

Purpose: To assess the performance of two approaches to the system response matrix (SRM) calculation in pinhole single photon emission computed tomography (SPECT) reconstruction. Methods: Evaluation was performed using experimental data from a low magnification pinhole SPECT system that consisted of a rotating flat detector with a monolithic scintillator crystal. The SRM was computed following two approaches, which were based on Monte Carlo simulations (MC-SRM) and analytical techniques in combination with an experimental characterization (AE-SRM). The spatial response of the system, obtained by using the two approaches, was compared with experimental data. The effect of the MC-SRM and AE-SRM approaches on the reconstructed image was assessed in terms of image contrast, signal-to-noise ratio, image quality, and spatial resolution. To this end, acquisitions were carried out using a hot cylinder phantom (consisting of five fillable rods with diameters of 5, 4, 3, 2, and 1 mm and a uniform cylindrical chamber) and a custom-made Derenzo phantom, with center-to-center distances between adjacent rods of 1.5, 2.0, and 3.0 mm. Results: Good agreement was found for the spatial response of the system between measured data and results derived from MC-SRM and AE-SRM. Only minor differences for point sources at distances smaller than the radius of rotation and large incidence angles were found. Assessment of the effect on the reconstructed image showed a similar contrast for both approaches, with values higher than 0.9 for rod diameters greater than 1 mm and higher than 0.8 for rod diameter of 1 mm. The comparison in terms of image quality showed that all rods in the different sections of a custom-made Derenzo phantom could be distinguished. The spatial resolution (FWHM) was 0.7 mm at iteration 100 using both approaches. The SNR was lower for reconstructed images using MC-SRM than for those reconstructed using AE-SRM, indicating that AE-SRM deals better with the projection noise than MC-SRM. Conclusions: The authors' findings show that both approaches provide good solutions to the problem of calculating the SRM in pinhole SPECT reconstruction. The AE-SRM was faster to create and handle the projection noise better than MC-SRM. Nevertheless, the AE-SRM required a tedious experimental characterization of the intrinsic detector response. Creation of the MC-SRM required longer computation time and handled the projection noise worse than the AE-SRM. Nevertheless, the MC-SRM inherently incorporates extensive modeling of the system and therefore experimental characterization was not required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proposal of a Novel Approach to Developing Material Models for Micro-scale Composites Based on Testing and Modeling of Macro-scale Composites

The Los Alamos National Laboratory's Weapon Systems Engineering division's Advanced Engineering Analysis group employs material constitutive models of composites for use in simulations of components and assemblies of interest. Experimental characterization, modeling and prediction of the macro-scale (i.e. continuum) behaviors of these composite materials is generally difficult because they exhibit nonlinear behaviors on the meso- (e.g. micro-) and macro-scales. Furthermore, it can be difficult to measure and model the mechanical responses of the individual constituents and constituent interactions in the composites of interest. Current efforts to model such composite materials rely on semi-empirical models in which meso-scale properties are inferred from continuum level testing and modeling. The proposed approach involves removing the difficulties of interrogating and characterizing micro-scale behaviors by scaling-up the problem to work with macro-scale composites, with the intention of developing testing and modeling capabilities that will be applicable to the mesoscale. This approach assumes that the physical mechanisms governing the responses of the composites on the meso-scale are reproducible on the macro-scale. Working on the macro-scale simplifies the quantification of composite constituents and constituent interactions so that efforts can be focused on developing material models and the testing techniques needed for calibration and validation. Other benefits to working with macro-scale composites include the ability to engineer and manufacture—potentially using additive manufacturing techniques—composites that will support the application of advanced measurement techniques such as digital volume correlation and three-dimensional computed tomography imaging, which would aid in observing and quantifying complex behaviors that are exhibited in the macro-scale composites of interest. Ultimately, the goal of this new approach is to develop a meso-scale composite modeling framework, applicable to many composite materials, and the corresponding macroscale testing and test data interrogation techniques to support model calibration.

36 MATERIALS SCIENCE↗

Hedgehog Pathway Inhibition Radiosensitizes Non-Small Cell Lung Cancers

Purpose: Despite improvements in chemoradiation, local control remains a major clinical problem in locally advanced non-small cell lung cancer. The Hedgehog pathway has been implicated in tumor recurrence by promoting survival of tumorigenic precursors and through effects on tumor-associated stroma. Whether Hedgehog inhibition can affect radiation efficacy in vivo has not been reported. Methods and Materials: We evaluated the effects of a targeted Hedgehog inhibitor (HhAntag) and radiation on clonogenic survival of human non-small cell lung cancer lines in vitro. Using an A549 cell line xenograft model, we examined tumor growth, proliferation, apoptosis, and gene expression changes after concomitant HhAntag and radiation. In a transgenic mouse model of Kras{sup G12D}-induced and Twist1-induced lung adenocarcinoma, we assessed tumor response to radiation and HhAntag by serial micro-computed tomography (CT) scanning. Results: In 4 human lung cancer lines in vitro, HhAntag showed little or no effect on radiosensitivity. By contrast, in both the human tumor xenograft and murine inducible transgenic models, HhAntag enhanced radiation efficacy and delayed tumor growth. By use of the human xenograft model to differentiate tumor and stromal effects, mouse stromal cells, but not human tumor cells, showed significant and consistent downregulation of Hedgehog pathway gene expression. This was associated with increased tumor cell apoptosis. Conclusions: Targeted Hedgehog pathway inhibition can increase in vivo radiation efficacy in lung cancer preclinical models. This effect is associated with pathway suppression in tumor-associated stroma. These data support clinical testing of Hedgehog inhibitors as a component of multimodality therapy for locally advanced non-small cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fully Arbitrary Control of Frequency-Bin Qubits

Accurate control of two-level systems is a longstanding problem in quantum mechanics. One such quantum system is the frequency-bin qubit: a single photon existing in superposition of two discrete frequency modes. In this Letter, we demonstrate fully arbitrary control of frequency-bin qubits in a quantum frequency processor for the first time. Furthermore, we numerically establish optimal settings for multiple configurations of electro-optic phase modulators and pulse shapers, experimentally confirming near-unity mode-transformation fidelity for all fundamental rotations. Performance at the single-photon level is validated through the rotation of a single frequency-bin qubit to 41 points spread over the entire Bloch sphere, as well as tracking of the state path followed by the output of a tunable frequency beam splitter, with Bayesian tomography confirming state fidelities Fρ>0.98 for all cases. Overall, such high-fidelity transformations expand the practical potential of frequency encoding in quantum communications, offering exceptional precision and low noise in general qubit manipulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗