Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Three-dimensional flow over a conical afterbody containing a centered propulsive jet - A numerical simulation

The supersonic flow field over a body of revolution incident to the free stream is simulated numerically on a large, array processor (the CDC Cyber 205). The configuration is composed of a cone-cylinder forebody followed by a conical afterbody from which emanates a centered, supersonic propulsive jet. The free-stream Mach number is 2, the jet-exit Mach number is 2.5, and the jet-to-free-stream static pressure ratio is 3. Both the external flow and the exhaust are ideal air at a common total temperature. The thin-layer approximation to the time-dependent, compressible, Reynolds-averaged Navier-Stokes equations are solved using an implicit finite-difference algorithm. The data base, of 5 million words, is structured in a 'pencil' format so that efficient use of the array processor can be realized. The computer code is completely vectorized to take advantage of the data structure. Turbulence closure is achieved using an empirical algebraic eddy-viscosity model. The configuration and flow conditions correspond to published experimental tests and the computed solutions are consistent with the experimental data.

Deiwert, G. S.↗

Remote sensing by IR heterodyne spectroscopy

The use of infrared heterodyne spectroscopy for the study of planetary atmospheres is discussed. Infrared heterodyne spectroscopy provides a convenient and sensitive method for measuring the true intensity profiles of atmospheric spectral lines. Application of radiative transfer theory to measured lineshapes can then permit the study of molecular abundances, temperatures, total pressures, excitation conditions, and dynamics of the regions of line formation. The theory of formation of atmospheric spectral lines and the retrieval of the information contained in these molecular lines is illustrated. Notable successes of such retrievals from infrared heterodyne measurements on Venus, Mars, Jupiter and the earth are given. A discussion of developments in infrared heterodyne technology is also presented. Previously announced in STAR as N83-28551

Kostiuk, T.↗

Hot-Wire Probe for Compressible Subsonic Flow

Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

Stainback, P. C.↗

End-wall boundary layer measurements in a two-stage fan

Detailed flow measurements made in the casing boundary layer of a two-stage transonic fan are summarized. These measurements were taken at stations upstream of the fan, between all blade rows, and downstream of the last blade row. At the design tip speed of 429 m/sec the fan achieved a peak efficiency of 0.846 at a pressure ratio of 2.471. The boundary layer data were obtained at three weight flows at the design speed: one near choke flow, one near peak efficiency, and one near stall. Conventional boundary layer parameters were calculated from the data measured at each measuring station for each of the three flows. A classical two dimensional casing boundary layer was measured at the fan inlet and extended inward to approximately 15 percent of span. A highly three dimensional boundary layer was measured at the exit of each blade row and extended inward to approximately 10 percent of span. The steep radial gradient of axial velocity noted at the exit of the rotors was reduced substantially as the flow passed through the stators. This reduced gradient is attributed to flow mixing. The amount of flow mixing was reflected in the radial redistribution of total temperature as the flow passed through the stators. The data also show overturning of the tip flow at the stator exits that is consistent with the expected effect of the secondary flow field. The blockage factors calculated from the measured data show an increase in blockage across the rotors and a decrease across the stators.

Ball, C. L.↗

An empirical method for predicting the mixing noise levels of subsonic circular and coaxial jets

An empirical method for predicting the static free field source noise levels of subsonic circular and coaxial jet flow streams is presented. The method was developed from an extensive data base of 817 jet tests obtained from five different government and industry sources in three nations. The prediction method defines the jet noise in terms of four components which are overall power level, power spectrum level, directivity index, and relative spectrum level. The values of these noise level components are defined on a grid consisting of seven frequency parameter values (Strouhal numbers) and seven directivity angles. The value of the noise level at each of these grid points is called a noise level coordinate and was defined as a function of five jet exhaust flow state parameters which are equivalent jet velocity, equivalent jet total temperature, the velocity ratio (outer stream to inner stream), temperature ratio, and area ratio. The functions were obtained by curve fitting in a least squares sense the noise level coordinates from the data base in a five dimensional flow state space using a third order Taylor series. The noise level coordinates define the component noise levels for all frequencies and directivities through a bicubic spline function.

Russell, J. W.↗

Three-dimensional flow over a conical afterbody containing a centered propulsive jet: A numerical simulation

The supersonic flow field over a body of revolution incident to the free stream is simulated numerically on a large, array processor (the CDC CYBER 205). The configuration is composed of a cone-cylinder forebody followed by a conical afterbody from which emanates a centered, supersonic propulsive jet. The free-stream Mach number is 2, the jet-exist Mach number is 2.5, and the jet-to-free-stream static pressure ratio is 3. Both the external flow and the exhaust are ideal air at a common total temperature.

Deiwert, G. S.↗

Detailed flow measurements in casing boundary layer of 429-meter-per-second-tip-speed two-stage fan

Detailed flow measurements between all blade rows were taken in the outer 30 percent of passage height of a two stage fan. Tabulations of the detailed flow measurements are included. Results of these measurements revealed the steep axial velocity profiles near the casing. The axial velocity profile near the casing at the rotor exists was much steeper than at the stator exits. The data also show overturning of the flow at the tip at the stator exits. The effect of mixing is shown by the redistribution of the first stage rotor exit total temperature profile as it passes through the following stator.

Gorrell, W. T.↗

Flow structure within a heated rectangular jet ejector

Preliminary results of an experimental study of the flow field structure within a rectangular jet ejector are presented. The tests determined the effect of primary jet heating and ejector duct width on the flow field at a fixed jet exit Mach number of 0.3. For comparison the rectangular jet without the presence of the ejector shroud was also studied. Measurements of the mean velocity field, total temperature field, and ejector shroud surface pressure distribution, along with schlieren flow visualization, were made. It was found that: the ejector did not enhance centerline temperature decay in comparison to the free jet; the presence of the ejector shroud significantly reduced jet growth; and, the ejector centerline velocity/temperature decay was not sensitive to duct width variations.

Mclachlan, B. G.↗

On the proper Mach number and ratio of specific heats for modeling the Venus bow shock

Observational data from the Pioneer Venus Orbiter are used to investigate the physical characteristics of the Venus bow shock, and to explore some general issues in the numerical simulation of collisionless shocks. It is found that since equations from gas-dynamic (GD) models of the Venus shock cannot in general replace MHD equations, it is not immediately obvious what the optimum way is to describe the desired MHD situation with a GD code. Test case analysis shows that for quasi-perpendicular shocks it is safest to use the magnetospheric Mach number as an input to the GD code. It is also shown that when comparing GD predicted temperatures with MHD predicted temperatures total energy should be compared since the magnetic energy density provides a significant fraction of the internal energy of the MHD fluid for typical solar wind parameters. Some conclusions are also offered on the properties of the terrestrial shock.

Tatrallyay, M.↗

Langley Mach 4 scramjet test facility

An engine test facility was constructed at the NASA Langley Research Center in support of a supersonic combustion ramjet (scramjet) technology development program. Hydrogen combustion in air with oxygen replenishment provides simulated air at Mach 4 flight velocity, pressure, and true total temperature for an altitude range from 57,000 to 86,000 feet. A facility nozzle with a 13 in square exit produces a Mach 3.5 free jet flow for engine propulsion tests. The facility is described and calibration results are presented which demonstrate the suitability of the test flow for conducting scramjet engine research.

Earl H Andrews Jr.↗

An experimental study of tone excited heated jets

The objective of this investigation was to obtain detailed experimental data on the effects of upstream acoustic excitation on the mixing of heated jets with the surrounding air. Based on the information gathered in the literature survey, a technical approach was developed to carry out a systematic set of mean flowfield measurements for a broad range of jet operating and acoustic excitation conditions. Most of the results were obtained at Mach numbers of 0.3 and 0.8 and total temperatures of up to 800 K. Some measurements were made also for the fully expanded supersonic jet of Mj = 1.15. The maximum level of excitation was Le equal to or less than 150 dB and a range of excitation frequencies up to fe = 4 kHz was used. The important results derived from this study can be summarized as follows: (1) the sensitivity of heated jets to upstream acoustic excitation varies strongly with the jet operating conditions, (2) the threshold excitation level increases with increasing jet temperature, and (3) the preferred Strouhal number does not change significantly with a change of the jet operating conditions.

Lepicovsky, J.↗

Acoustic control of free jet mixing

The paper reports a detailed study on the acoustic control of free jet mixing at realistic Reynolds numbers. The experimental results were obtained at Mach numbers of 0.3 and 0.8 and flow total temperatures up to 800 K. The Reynolds numbers ranged from 350,000 to 1,300,000. Excitation Strouhal numbers were in the range of 0.2 to 0.6. The experimental results are compared with predictions, based on an extension of the analysis by Tam and Morris. The results showed that proper upstream tone excitation enhances mixing of unheated jets for both high-speed, high Reynolds number conditions and for low-speed conditions. The heated jet, however, shows a response to upstream excitation that depends on jet Mach number. The agreement between the predictions and the experiments is very good for unheated jet conditions. However, for jets heated to temperatures above 600 K, the theoretical predictions differ from the experimental results.

Lepicovsky, J.↗

Operating Characteristics of the Multiple Critical Venturi System and Secondary Calibration Nozzles Used for Weight-Flow Measurements in the Langley 16-Foot Transonic Tunnel

An investigation has been conducted in the Langley 16 Foot Transonic Tunnel to determine the weight flow measurement characteristics of a multiple critical Venturi system and the nozzle discharge coefficient characteristics of a series of convergent calibration nozzles. The effects on model discharge coefficient of nozzle throat area, model choke plate open area, nozzle pressure ratio, jet total temperature, and number and combination of operating Venturis were investigated. Tests were conducted at static conditions (tunnel wind off) at nozzle pressure ratios from 1.3 to 7.0.

Berrier, B. L.↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗

Thermodynamic evaluation of transonic compressor rotors using the finite volume approach

A method was developed which calculates two-dimensional, transonic, viscous flow in ducts. The finite volume, time marching formulation is used to obtain steady flow solutions of the Reynolds-averaged form of the Navier Stokes equations. The entire calculation is performed in the physical domain. The method is currently limited to the calculation of attached flows. The features of the current method can be summarized as follows. Control volumes are chosen so that smoothing of flow properties, typically required for stability, is now needed. Different time steps are used in the different governing equations to improve the convergence speed of the viscous calculations. A new pressure interpolation scheme is introduced which improves the shock capturing ability of the method. A multi-volume method for pressure changes in the boundary layer allows calculations which use very long and thin control volumes. A special discretization technique is also used to stabilize these calculations. A special formulation of the energy equation is used to provide improved transient behavior of solutions which use the full energy equation. The method is then compared with a wide variety of test cases. The freestream Mach numbers range from 0.075 to 2.8 in the calculations. Transonic viscous flow in a converging diverging nozzle is calculated with the method; the Mach number upstream of the shock is approximately 1.25. The agreement between the calculated and measured shock strength and total pressure losses is good. Essentially incompressible turbulent boundary layer flow in a adverse pressure gradient is calculated and the computed distribution of mean velocity and shear stress are in good agreement with the measurements. At the other end of the Mach number range, a flat plate turbulent boundary layer with a freestream Mach number of 2.8 is calculated using the full energy equation; the computed total temperature distribution and recovery factor agree well with the measurements when a variable Prandtl number is used through the boundary layer.

Nicholson, S.↗

Numerical simulation of unsteady flow in an axisymmetric shear layer

Numerical simulation of unsteady flow in an axisymmetric subsonic shear layer is accomplished by solving the time-dependent compressible Navier-Stokes equations. The objective of the effort is to investigate by numerical means the influence of various flow parameters on the shear layer behavior. The parameters investigated include the velocity ratio of two streams, total temperature, and nozzle lip thickness. The computations are performed on a CRAY-IS computer using McCormack's explicit finite difference scheme. The computed results generally show qualitative agreement with experimental data.

Scott, J. N.↗

Steady inviscid three-dimensional flows

The present analysis combines some of the theoretical concepts suggested by Hawthorne (1955) with a numerical integration procedure suggested by Martin (1978). The resulting algorithm is for inviscid subsonic flows. Thus, it is restricted to high Reynolds number flows. Chang and Adamczyk (1983) have provided a detailed derivation of the present algorithm along with a discussion of its stability bounds. The present paper represents a summary of this work. The integration of the continuity equation is considered along with an evaluation of the entropy, total temperature, and vorticity field. Attention is given to the shear-flow algorithm construction, and an application to a shear flow in a turning channel. A description of numerical results is also provided. The discussed algorithm represents a new procedure for solving inviscid subsonic three-dimensional rotational flows.

Adamczyk, J. J.↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗