SlimIO: Lightweight I/O Path Design for Write Isolation in FDP-backed In-Memory Databases

In-Memory Databases (IMDBs) are widely used with HPC applications to manage transient data, often using snapshot-based persistence for backups. Redis, a representative IMDB, employs both snapshot and Write-Ahead Log (WAL) mechanisms, storing data on persistent devices via the traditional kernel I/O path. This method incurs syscall overhead, I/O contention between processes, and SSD garbage collection (GC) delays. To address these issues, we propose SlimIO, which adopts I/O passthru to minimize syscall overhead and inter-process I/O interference. Additionally, it leverages Flexible Data Placement (FDP) SSDs as backup storage to avoid performance degradation from SSD GC. Experimental results show that SlimIO reduces snapshot time by up to 25%, increases query throughput by up to 30% during non-snapshot periods, and lowers 99.9%-ile latency by up to 50%. Furthermore, it achieves a write amplification factor (WAF) of 1.00, indicating no redundant internal writes, thus extending SSD lifespan.

Lee, Sangyun [Sogang University]↗

pnnl/pecblocks

ConverterBlocks uses the output of detailed electromagnetic transient (EMT) simulations to produce generalized block diagram models of power electronic systems. The process uses deep learning with customized block architectures. The outputs are reduced-order models that meet specified accuracy requirements, while providing important advantages over the original EMT models: ConverterBlock models have fewer nodes and can take longer time steps, resulting in shorter simulation times ConverterBlock models are continuously differentiable, making them compatible with control design methodsGeneralized block diagram modeling of power electronic converters for grid solar and storage applications.

McDermott, Tom↗

Optimizing the lean hydrocarbon NO x trap: Sequential and dual-layer configurations

Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NO x during engine cold-start when exhaust temperatures are below 200 °C. In this study the performance of coupled low temperature NO x , n-C 12 H 26 (C 12 ), and C 3 H 6 trapping, release and conversion for a series of model Lean Hydrocarbon NO x Trap (LHCNT) catalysts are examined. Pd and Pt supported on small-pore (SSZ-13) and large-pore (BEA) zeolites are selected based on the performance during transient NO and C 12 uptake, release and conversion experiments. These catalysts are combined into sequential (Pt + Pd/BEA → Pd/SSZ-13; Pd/SSZ-13 → Pt + Pd/BEA) and dual-layer (Pt + Pd/BEA top, Pd/SSZ-13 bottom) configurations in an attempt to improve the trapping and conversion performance. While all three configurations trap between 75 and 100 μmolNO x /g-cat, the Pd/SSZ-13 → Pt + Pd/BEA sequential configuration is most effective in simultaneously trapping C 12 and NO in the presence of H 2 O, resulting in excellent NO and C 12 storage below 100 °C with release and/or conversion at or above 200 °C. For each configuration, C 12 oxidation lights-off below 300 °C and NO oxidation achieves ~35 % conversion in the absence of C 12 . Neither the presence of C 12 nor the order of the sequential configuration has a significant impact on NO uptake. C 12 significantly delays NO and NO 2 desorption to temperatures exceeding 300 °C. The more compact dual-layer catalyst is most effective in forming NO 2 as the release temperature lines up with the maximum NO conversion temperature but traps less C 12 than the sequential configurations. The addition of C 3 H 6 in the feed on the dual-layer catalyst leads to further delay in the NO x desorption as well as increased NO and C 12 conversion at high temperatures. Here, the overall findings provide guidance in the optimizing LHCNT configuration for realistic feeds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Country-level land carbon sink and its causing components by the middle of the twenty-first century

Abstract Background Countries have long been making efforts by reducing greenhouse-gas emissions to mitigate climate change. In the agreements of the United Nations Framework Convention on Climate Change, involved countries have committed to reduction targets. However, carbon (C) sink and its involving processes by natural ecosystems remain difficult to quantify. Methods Using a transient traceability framework, we estimated country-level land C sink and its causing components by 2050 simulated by 12 Earth System Models involved in the Coupled Model Intercomparison Project Phase 5 (CMIP5) under RCP8.5. Results The top 20 countries with highest C sink have the potential to sequester 62 Pg C in total, among which, Russia, Canada, USA, China, and Brazil sequester the most. This C sink consists of four components: production-driven change, turnover-driven change, change in instantaneous C storage potential, and interaction between production-driven change and turnover-driven change. The four components account for 49.5%, 28.1%, 14.5%, and 7.9% of the land C sink, respectively. Conclusion The model-based estimates highlight that land C sink potentially offsets a substantial proportion of greenhouse-gas emissions, especially for countries where net primary production (NPP) likely increases substantially and inherent residence time elongates.

54 ENVIRONMENTAL SCIENCES↗

Spray Bar Zero-Gravity Vent System for On-Orbit Liquid Hydrogen Storage

During zero-gravity orbital cryogenic propulsion operations, a thermodynamic vent system (TVS) concept is expected to maintain tank pressure control without propellant resettling. In this case, a longitudinal spray bar mixer system, coupled with a Joule-Thompson (J-T) valve and heat exchanger, was evaluated in a series of TVS tests using the 18 cu m multipurpose hydrogen test bed. Tests performed at fill levels of 90, 50, and 25 percent, coupled with heat tank leaks of about 20 and 50 W, successfully demonstrated tank pressure control within a 7-kPa band. Based on limited testing, the presence of helium constrained the energy exchange between the gaseous and liquid hydrogen (LH2) during the mixing cycles. A transient analytical model, formulated to characterize TVS performance, was used to correlate the test data. During self-pressurization cycles following tank lockup, the model predicted faster pressure rise rates than were measured; however, once the system entered the cyclic self-pressurization/mixing/venting operational mode, the modeled and measured data were quite similar. During a special test at the 25-percent fill level, the J-T valve was allowed to remain open and successfully reduced the bulk LH2 saturation pressure from 133 to 70 kPa in 188 min.

Hastings, L. J.↗

A time dependent difference theory for sound propagation in ducts with flow

A time dependent numerical solution of the linearized continuity and momentum equation is developed for sound propagation in a two-dimensional straight hard or soft wall duct with a sheared mean flow. The time dependent governing acoustic-difference equations and boundary conditions are developed along with a numerical determination of the maximum stable time increments. The analysis begins with a harmonic noise source radiating into a quiescent duct. This explicit iteration method then calculates stepwise in real time to obtain the transient as well as the 'steady' state solution of the acoustic field. Example calculations are presented for sound propagation in hard and soft wall ducts, with no flow and with plug flow. Although the problem with sheared flow has been formulated and programmed, sample calculations have not yet been examined. So far, the time dependent finite difference analysis has been found to be superior to the steady state finite difference and finite element techniques because of shorter solution times and the elimination of large matrix storage requirements.

Baumeister, K. J.↗

Concentration fluctuations and flammability of cryo-compressed hydrogen and methane jets

Compressed hydrogen stored at cryogenic temperatures has a much higher density than room-temperature storage, which enables large-scale hydrogen storage and transport. An understanding of the release of cryogenic hydrogen from pressurized vessels is needed to evaluate the risk and safety concerns with the use of this fuel. Here, the present work extends the analysis of previous experimental studies that measured the gas concentrations of cryo-compressed hydrogen jets and methane jets using a laser Raman scattering diagnostic system. Since the Raman signals are very small, a denoising algorithm was applied to significantly reduce the noise to enable statistical analysis of the data. The transient features of the turbulent jets were characterized by their concentration intermittencies and probability density functions (PDFs). A two-part PDF was developed to predict the bimodal features of the jet concentration distributions. Then, the flammability factors of the cryogenic jets were calculated based on the intermittency and the PDF.

33 ADVANCED PROPULSION SYSTEMS↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CAVE3: A general transient heat transfer computer code utilizing eigenvectors and eigenvalues

The method of solution is a hybrid analytical numerical technique which utilizes eigenvalues and eigenvectors. The method is inherently stable, permitting large time steps even with the best of conductors with the finest of mesh sizes which can provide a factor of five reduction in machine time compared to conventional explicit finite difference methods when structures with small time constants are analyzed over long time periods. This code will find utility in analyzing hypersonic missile and aircraft structures which fall naturally into this class. The code is a completely general one in that problems involving any geometry, boundary conditions and materials can be analyzed. This is made possible by requiring the user to establish the thermal network conductances between nodes. Dynamic storage allocation is used to minimize core storage requirements. This report is primarily a user's manual for CAVE3 code. Input and output formats are presented and explained. Sample problems are included which illustrate the usage of the code as well as establish the validity and accuracy of the method.

Palmieri, J. V.↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

Transient Response of Shells of Revolution by Direct Integration and Modal Superposition Methods

The results of an analytical effort to obtain and evaluate transient response data for a cylindrical and a conical shell by use of two different approaches: direct integration and modal superposition are described. The inclusion of nonlinear terms is more important than the inclusion of secondary linear effects (transverse shear deformation and rotary inertia) although there are thin-shell structures where these secondary effects are important. The advantages of the direct integration approach are that geometric nonlinear and secondary effects are easy to include and high-frequency response may be calculated. In comparison to the modal superposition technique the computer storage requirements are smaller. The advantages of the modal superposition approach are that the solution is independent of the previous time history and that once the modal data are obtained, the response for repeated cases may be efficiently computed. Also, any admissible set of initial conditions can be applied.

Stephens, W. B.↗

Failure Behavior and Control-Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Failure Behavior and Control Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Interpretation of bottom-hole temperature data from CO 2 injection projects

Although bottom-hole temperature (BHT) data is routinely collected with bottom-hole pressure (BHP) data during CO 2 injection in geological storage projects, it is seldom analyzed in a quantitative manner. However, the BHP and BHT signals do exhibit correlated behavior. This work proposes a practical approach for using BHT data from warmback (no injection) periods, in conjunction with the amplitude of BHP and BHT changes during the preceding injection event, to estimate formation permeability. The methodology is demonstrated using data from the AEP Mountaineer project in USA where CO 2 injection was carried out into a saline aquifer. Estimated permeability values from the proposed approach are in good agreement with those obtained from transient pressure analysis of BHP data from the falloff period.

42 ENGINEERING↗

Monitoring natural gas storage using Synthetic Aperture Radar: are the residuals informative?

Estimates of line-of-sight (LOS) displacements from Interferometric Synthetic Aperture Radar (InSAR) observations serve as the basis of the long-term monitoring of an operating natural gas storage site at Honor Rancho in California. Here, an inversion algorithm is used to estimate the portion of the signal that is attributable to deformation within the gas storage reservoir, located at a depth of around 3 km. Removing this contribution produces residuals that are used to characterize the background variation is surface deformation at the gas storage facility and to determine a threshold that can signify unusually large residuals. An application to almost 7 yr of InSAR data, from 2011 until 2018, indicates that there are intervals of heightened residuals as well as brief episodes of anomalously large misfits. An examination of the spatial distributions of the individual residual LOS displacements indicates larger displacements in an alluvial valley just south of the reservoir, with rapid spatial variations in sign, indicating a rather shallow origin. Furthermore, the two anomalous events also involve rapid spatial variations in the LOS displacement residuals directly above the storage facility. The results demonstrate that the technique of extracting residuals after removing the reservoir signal is a useful approach, even in the case of this deep reservoir, and is a promising method for long-term monitoring.

03 NATURAL GAS↗

Flight experiment of thermal energy storage

Thermal energy storage (TES) enables a solar dynamic system to deliver constant electric power through periods of sun and shade. Brayton and Stirling power systems under current considerations for missions in the near future require working fluid temperatures in the 1100 to 1300+ K range. TES materials that meet these requirements fall into the fluoride family of salts. Salts shrink as they solidify, a change reaching 30 percent for some salts. Hot spots can develop in the TES container or the container can become distorted if the melting salt cannot expand elsewhere. Analysis of the transient, two-phase phenomenon is being incorporated into a three-dimensional computer code. The objective of the flight program is to verify the predictions of the code, particularly of the void location and its effect on containment temperature. The four experimental packages comprising the program will be the first tests of melting and freezing conducted under microgravity.

Namkoong, David↗

Large Scale Cryogenic Storage with Active Refrigeration

Storage and transfer of cryogenic liquefied gases on volume scales from under 10 liters for lab use, up to hundreds of millions of liters for industrial applications is of paramount importance across a vast range of industries. Traditionally, these commodities have been stored at or near the normal boiling point due to relative ease of operation and safety-related considerations; however, this also means that some percentage will always be lost due to environmental heat leaking into the vessel and causing boil-off. These losses become more concerning as scales increase, and are of particular importance for high-cost commodities such helium and hydrogen. Additionally, the normal boiling point marks the highest liquid density achievable; which becomes a strong driver of end-use system designs such as space launch vehicles. Recent development and testing of an Integrated Refrigeration and Storage (IRAS) system for liquid hydrogen has proven that next generation cryogenic storage operations such as zero boil-off and densification are feasible on a large scale. This IRAS system married an 850 Watt at 20 Kelvin reverse-Brayton cycle commercial cryogenic refrigerator with a 125,000 liter LH2 storage tank via and internal tubular heat exchanger. This allowed heat to be removed directly from the hydrogen, and by extension, provided a means to control the bulk thermodynamic state. Zero boil-off, in-situ liquefaction, and densification down to the triple point was performed during testing, and data such as fluid temperature profiles and tank pressure were gathered. Details regarding the design, setup, and testing of the IRAS system are discussed herein, and the data used to anchor various physics models created to predict the behavior of the system during transient and steady state operation. It is hoped that these efforts will provide a useful basis for the design and implementation of future large scale IRAS systems across numerous industries.

Swanger, Adam M.↗

Liquid Nitrogen (Oxygen Simulant) Thermodynamic Vent System Test Data Analysis

In designing systems for the long-term storage of cryogens in low-gravity (space) environments, one must consider the effects of thermal stratification on tank pressure that will occur due to environmental heat leaks. During low-gravity operations, a Thermodynamic Vent System (TVS) concept is expected to maintain tank pressure without propellant resettling. A series of TVS tests was conducted at NASA Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a liquid oxygen (LO2) simulant. The tests were performed at tank til1 levels of 90%, 50%, and 25%, and with a specified tank pressure control band. A transient one-dimensional TVS performance program is used to analyze and correlate the test data for all three fill levels. Predictions and comparisons of ullage pressure and temperature and bulk liquid saturation pressure and temperature with test data are presented.