Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Bayonet for superfluid helium transfer in space

A prototype superfluid helium bayonet for potential space applications has been developed and evaluated with a low heat leak test apparatus. Measured heat leak of the 13 mm (1/2 inch) bayonet pair is 0.21 W at 1.8 K with an uncertainty of +0.09/-0.05 W. Bayonets are fabricated with thin, electron beam (EB) welded tubes which are EB welded to machined nose and flange pieces. Low heat leak structural integrity is provided by a 0.9 mm thickness of filament wound fiberglass-epoxy. Superfluid creep is restricted by KEL-F nose seals which form vacuum-tight extensions to the bayonet cold end pieces.

Mcintosh, G. E.↗

Scanning Tunneling Microscope For Use In Vacuum

Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

Abel, Phillip B.↗

Fluid Line Evacuation and Freezing Experiments for Digital Radiator Concept

The digital radiator technology is one of three variable heat rejection technologies being investigated for future human-rated NASA missions. The digital radiator concept is based on a mechanically pumped fluid loop with parallel tubes carrying coolant to reject heat from the radiator surface. A series of valves actuate to start and stop fluid flow to di erent combinations of tubes, in order to vary the heat rejection capability of the radiator by a factor of 10 or more. When the flow in a particular leg is stopped, the fluid temperature drops and the fluid can freeze, causing damage or preventing flow from restarting. For this reason, the liquid in a stopped leg must be partially or fully evacuated upon shutdown. One of the challenges facing fluid evacuation from closed tubes arises from the vapor generated during pumping to low pressure, which can cause pump cavitation and incomplete evacuation. Here we present a series of laboratory experiments demonstrating fluid evacuation techniques to overcome these challenges by applying heat and pumping to partial vacuum. Also presented are results from qualitative testing of the freezing characteristics of several different candidate fluids, which demonstrate significant di erences in freezing properties, and give insight to the evacuation process.

human space flight↗

Undercooling of bulk high temperature metals in the 100 meter drop tube

The 100-meter drop tube at NASA Marshall Space Flight Center provides an excellent opportunity to study the effects of containerless, microgravity processing in metals and alloys. In a series of experiments high melting temperature pure metals were melted in an electron beam furnace and dropped in vacuum. Sample sizes ranged from 0.175 to 1.2 grams. Large undercoolings on the order of 18 percent of the melting temperature were observed in Ti, Zr, Nb, Mo, Rh, Ta, and Pt. Undercoolings of 5 to 18 percent T(m) were observed in Ru and Ir. These undercooling results are consistent, repeatable, and occur in a high percentage of experiments. The experimental technique will be presented as well as the resultant microstructures of undercooled drops. The data will be discussed with respect to nucleation theory.

Hofmeister, William↗

Boundary-layer measurements on a high Reynolds number three-element airfoil

An experimental investigation is being conducted to evaluate the boundary layer associated with a two-dimensional three-element single-flap airfoil at high Reynolds numbers. The present measurements are being made in the Langley Low-Turbulence (centerline turbulence intensity level is 0.034 percent at a Mach number of 0.2 and a total pressure of 60 psia) Pressure Tunnel (LTPT). The LTPT is a closed-circuit wind tunnel with a test section which is 3 ft wide, 7.5 ft high, and 7.5 ft long. Operating total pressure for the LTPT varies from 10 atmospheres to near-vacuum conditions. Tests are being conducted at a Mach number of 0.2 and Reynolds numbers (based on chord length) of 5, 9, and 16 million. Measurements include boundary-layer velocity surveys at several chordwise locations and surface skin-friction measurements using Preston tubes.

Selby, Gregory V.↗

Free-stream temperature, density, and pressure measurements in an expansion tube flow

An experimental study was conducted to determine test-flow conditions in the Langley pilot model expansion tube. Measurements of temperature, density, wall pressure, pitot pressure, and shock and interface velocities were compared with theoretical calculations based on various models of the flow cycle. The vibrational temperature and integrated density of the molecular oxygen component of the flow were measured by use of vacuum ultraviolet absorption techniques. These measurements indicate both the presence and possible degree of nonequilibrium in the flow. Data are compared with several simplified models of the flow cycle, and data trends are discussed.

Haggard, K. V.↗

Analysis of the free-fall behavior of liquid-metal drops in a gaseous atmosphere

The free-fall of a liquid-metal drop and heat transfer from the drop to its environment are described for both a gaseous atmosphere and vacuum. A simple model, in which the drop is assumed to fall rectilinearly with behavior like that of a rigid particle, is developed first, then possible causes of deviation from this behavior are discussed. The model is applied to describe solidification of drops in a drop tube. Possible future developments of the model are suggested.

Mccoy, J. Kevin↗

Monocrystal-based microchannel plate image intensifier

A monocrystalline scintillator comprises a monocrystal and an optical plate wherein a first side of the monocrystal is adhered to the optical plate. The monocrystal comprises at least one of a rare earth garnet, a perovskite crystal, a rare-earth silicate, and a monocrystal oxysulphide. The scintillator assembly includes an adhesive adhering the optical plate to the first side of the monocrystal. The adhesive can comprise an ultra-high vacuum compatible adhesive. The adhesive is substantially transparent and has a refractive index matching the optical plate. The scintillator assembly can also include a reflective coating on the second side of the monocrystal. The monocrystalline scintillator assembly can be incorporated in a microchannel plate image intensifier tube to provide improved spatial resolution and temporal response.

Lumpkin, Alex H.↗

Development Study of Cartridge/Crucible Tube Materials

The limitations of traditional alloys and the desire for improved performance for components is driving the increased utilization of refractory metals in tile space industry. From advanced propulsion systems to high temperature furnace components for microgravity processing, refractory metals are being used for their high melting temperatures and inherent chemical stability. Techniques have been developed to produce near net shape refractory metal components utilizing vacuum plasma spraying. Material utilization is very high, and laborious machining can be avoided. As-spray formed components have been tested and found to perform adequately. However, increased mechanical and thermal properties are needed. To improve these properties, post processing thermal treatments such as hydrogen sintering and vacuum annealing have been performed. Components formed from alloys of tungsten, rhenium, tantalum, niobium, and molybdenum are discussed and a metallurgical analyses detailing the results are presented. A qualitative comparison of mechanical properties is also included.

McKechnie, Timothy N.↗

Passive heat removal in horizontally oriented micro-HTGRs

There are novel, horizontally oriented high-temperature gas-cooled micro-reactor (HTGR) designs under consideration because of their portability, simplicity, and reliable operation. These features of the micro-HTGR design can meet the fission battery attributes, such as economic, standardize, installed, unattended and reliable. Although there have been HTGR related safety studies, micro-HTGRs when horizontally oriented are expected to exhibit significantly different thermal physics. During the unavailability of helium circulation, the internal reactor core is designed to cool by block-to-block conduction and radiation, and the reactor vessel surface is cooled by the ambient air. This scenario is anticipated during the transport of the micro-HTGR in a shipping container. The conduction and radiation between the prismatic micro-HTGR blocks in the core can be influenced by variances in the thermal contacts. This work investigated the conduction within a simulated horizontal HTGR core. An experimental setup was used to validate a numerical model. The experimental setup consisted of a hexagonal assembly with scaled prismatic blocks placed within a high-temperature vacuum environment. The gaps between the blocks were well controlled and monitored. The experimental setup was designed in such a way that the temperature variation in the axial direction was minimal, such that the experiment could be observed as a 2D (r, ) heat transfer problem. The pressurized tube was equipped with Infra-Red (IR) transparent windows, and an IR camera was used to capture the spatio-temporal temperature evolution in the hexagonal block assembly during the cooldown experiments. The experimental scenario was computationally modeled with a finite element analysis (FEA) program. Once validated, the computational model was used to investigate the impact of gap conductance on overall decay heat removal. Using a conservative estimate for gap conductance value (100 W/m 2 -K) between the prismatic blocks, there is a negligible increase in temperature observed during decay heat generation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of Small (100-lb Thrust) Rocket Motors Using Coaxial Injection of Hydrazine and Nitrogen Tetroxide

An investigation was conducted on a small (approximately 100-lb thrust) rocket using coaxial injection of hydrazine and nitrogen tetroxide. Characteristic-velocity efficiencies of 94 percent of the theoretical shifting equilibrium value were obtained at a chamber pressure of about 300 pounds per square inch using a 21-tube injector and a combustion chamber characteristic length of 10 inches. Performance at lower chamber pressures could be improved by reducing contraction ratio and thereby increasing the combustion chamber length and injector pressure drop, which would tend to promote better mixing. Calculations based on experimental data showed a vacuum specific impulse of 305 seconds with a nozzle area ratio of 50.

Wasserbauer, Joseph F.↗

Shock Radiation Tests for Saturn and Uranus Entry Probes

This paper describes a test series in the Electric Arc Shock Tube at NASA Ames Research Center with the objective of quantifying shock-layer radiative heating magnitudes for future probe entries into Saturn and Uranus atmospheres. Normal shock waves are measured in Hydrogen/Helium mixtures (89:11 by mole) at freestream pressures between 13-66 Pa (0.1-0.5 Torr) and velocities from 20-30 km/s. No shock layer radiation is detected below 25 km/s, a finding consistent with predictions for Uranus entries. Between 25-30 km/s, radiance is quantified from the Vacuum Ultraviolet through Near Infrared, with focus on the Lyman-alpha and Balmer series lines of Hydrogen. Shock profiles are analyzed for electron number density and electronic state distribution. The shocks do not equilibrate over several cm, and distributions are demonstrated to be non-Boltzmann. Radiation data are compared to simulations of Decadal survey entries for Saturn and shown to be significantly lower than predicted with the Boltzmann radiation model.

Saturn Probe↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Method of preparing fiber reinforced ceramic material

Alternate layers of mats of specially coated SiC fibers and silicon monotapes are hot pressed in two stages to form a fiber reinforced ceramic material. In the first stage a die is heated to about 600 C in a vacuum furnace and maintained at this temperature for about one-half hour to remove fugitive binder. In the second stage the die temperature is raised to about 1000 C and the layers are pressed at between 35 and 138 MPa. The resulting preform is placed in a reactor tube where a nitriding gas is flowed past the preform at 1100 to 1400 C to nitride the same.

Bhatt, Ramakrishna T.↗

Hollow-Cathode Source Generates Plasma

Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

Deininger, W. D.↗

Design, fabrication, and performance of brazed, graphite electrode, multistage depressed collectors with 500-W, continuous wave, 4.8- to 9.6-GHz traveling-wave tubes

A small, isotropic graphite electrode, multistage depressed collector (MDC) was designed, fabricated, and evaluated in conjunction with a 500-W, continuous wave (CW), 4.8- to 9.6-GHz traveling-wave tube (TWT). The carbon electrode surfaces were used to improve the TWT overall efficiency by minimizing the secondary electron emission losses in the MDC. The design and fabrication of the brazed graphite MDC assembly are described. The brazing technique, which used copper braze filler metal, is compatible with both vacuum and the more commonly available hydrogen atmosphere brazing furnaces. The TWT and graphite electrode MCC bakeout, processing, and outgassing characteristics were evaluated and found to be comparable to TWT's equipped with copper electrode MDC's. The TWT and MDC performance was optimized for broadband CW operation at saturation. The average radiofrequency (RF), overall, and MDC efficiencies were 14.9, 46.4, and 83.6 percent, respectively, across the octave operating band. A 1500-hr CW test, conducted without the use of an appendage ion pump, showed no gas buildup and excellent stability of the electrode surfaces.

Ramins, Peter↗

Numerical and experimental investigations of rarefied nozzle and plume flows of nitrogen

Numerical and experimental investigations are performed for the rarefied flow of nitrogen through a small nozzle which is expanded into near-vacuum conditions. Two different numerical studies are undertaken: the first employs a continuum approach in solving the Navier-Stokes equations, and the second employs a particle approach through use of the direct simulation Monte Carlo method (DSMC). The experimental investigation concerns the measurement of pressure, using a Pitot tube, in the nozzle exit plane and near-field of the plume. Comparison of the experimental and numerical data at the nozzle exit reveals that the DSMC technique provides the more accurate description of the expanding flow. It is discovered that the DSMC solutions are quite sensitive to the model employed to simulate the interaction between the gas and the nozzle wall surface. It is concluded that the simplistic fully diffuse model is quite satisfactory for the present application.

Boyd, Iain D.↗

A review of long drop tubes as a supplement/alternative to space experiments

A description of the 100-m drop tube at the Marshall Space Flight Center is presented, along with some undercooling observations and a discussion of some microstructural properties of deeply undercooled Nb-Ge alloys. The facility comprises two turbopumps which can evacuate the tube to 0.00001 torr, and three IR detectors at 15, 80, and 103-m levels which are sensitive to light in the range of 9660-2635 K (wavelength range of 0.2 to 1.1 microns), though recalescence events were detected at 1700 K. Finally, hypercooling regimes and maximum possible undercooling in vacuum are defined for several materials, including Al, Cu, Ni, Fe, Pt, and Nb.

Bayuzick, R. J.↗