Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Dual-band reactively loaded microstrip antenna

A previously derived theory is applied to a microstrip antenna with a reactive load to produce a dual-band radiator. A model consisting of a rectangular patch radiator loaded with a variable length short-circuited coaxial stub was investigated experimentally. Comparisons of theoretical predictions and experimental data are made for the impedance and resonant frequencies as a function of the position of the load, the length of the stub, and the characteristic impedance of the stub.

Richards, W. F.↗

Adaptive stratified importance sampling: hybridization of extrapolation and importance sampling Monte Carlo methods for estimation of wind turbine extreme loads

Wind turbine extreme load estimation is especially difficult because turbulent inflow drives nonlinear turbine physics and control strategies; thus there can be huge differences in turbine response to essentially equivalent environmental conditions. The two main current approaches, extrapolation and Monte Carlo sampling, are both unsatisfying: extrapolation-based methods are dangerous because by definition they make predictions outside the range of available data, but Monte Carlo methods converge too slowly to routinely reach the desired 50-year return period estimates. Thus a search for a better method is warranted. We introduce an adaptive stratified importance sampling approach that allows for treating the choice of environmental conditions at which to run simulations as a stochastic optimization problem that minimizes the variance of unbiased estimates of extreme loads. Furthermore, the framework, built on the traditional bin-based approach used in extrapolation methods, provides a close connection between sampling and extrapolation, and thus allows the solution of the stochastic optimization (i.e., the optimal distribution of simulations in different wind speed bins) to guide and recalibrate the extrapolation. Results show that indeed this is a promising approach, as the variance of both the Monte Carlo and extrapolation estimates are reduced quickly by the adaptive procedure. We conclude, however, that due to the extreme response variability in turbine loads to the same environmental conditions, our method and any similar method quickly reaches its fundamental limits, and that therefore our efforts going forward are best spent elucidating the underlying causes of the response variability.

17 WIND ENERGY↗

TURBOMAT: A Probabilistic Turbomachinery Aeroelastic Analysis Tool

An integration of aeroelastic analysis procedures with probabilistic analysis methods enables us to design safe reliable engines with quantified reliability. Towards this goal, a graphical user interface (GUI) based tool that integrates the codes Aeroelastic analysis of propfans (ASTROP2) and Numerical Evaluation of Stochastic Structures Under Stress (NESSUS) is developed. The tool entitled TURBOMachinery Aeroelastic Analysis Tool (TURBOMAT), is developed utilizing the MATrix Laboratory (Matlab) Guide (Graphical User Interface Development) tool box. TURBOMAT provides a user friendly computational environment for rapid assessment of Turbomachinery blades flutter characteristics, subjected to uncertain loading conditions with variability in material and aerodynamic properties. The tool is seen as an education tool for new students and young engineers starting their careers in structural Aeroelasticity who want to learn and understand aeroelastic aspects of turbomachinery components, fans, compressors and turbines, including uncertainties in loading and material properties.A typical fan blade configuration geometry was chosen to demonstrate the tool. The results are presented in the form of probabilistic density function (PDF), the cumulative distribution function (CDF) and sensitivity factors. Both first order fast probability integration (FPI) and the Monto Carlo (MC) techniques are used in the analysis and compared. The tool enabled us to quantify blade flutter reliability as well as the ranking of uncertain variables and their importance to blade flutter response.

Aeroelastic Analysis↗

Creep Testing of Vectran Yarn

NASA and industry are developing inflatable space structures to provide deployable habitable volumes for future exploration missions in space and on the surface of the Moon and Mars. These structures must withstand the constant pressure loading of multi-year missions. These missions therefore require excellent creep resistance in the constituent cordage and webbings that provide the primary structure of the vessel, which is typically constructed using high-strength synthetic materials such as Vectran. Real-time and accelerated creep testing of Vectran webbings has been performed at NASA Langley Research Center (LaRC), however, acceptable correlation between the results of the two approaches has not yet been achieved. Given the additional complexity of the webbing architecture, creep testing at the yarn level is being studied to reduce the number of interacting properties and focus on the core creep behavior to see if better correlation can be achieved between real-time and accelerated tests. To achieve this objective a creep test stand that is able to support simultaneous testing of five Vectran yarns had been previously designed and built. The test stand utilizes two clamp-wrap grips to mount the yarn and has a 10:1 load ratio, via a lever-arm, henceforth, known as the lever-arm test stand. Real-time creep testing (without measuring the strain of the yarn) in this fixture produces yarn ruptures in the gauge section. However, a large scatter in the times to failure was seen in the results across multiple loading conditions. For example, a test at 70% of the ultimate tensile strength (UTS) was found to have specimens that failed within a matter of hours and others that took over 6 weeks to fail. Prior test data on Vectran webbings had indicated high variability in the material strength, leading to higher than average scatter in the creep testing of webbings, which could translate to the scatter in creep behavior at the yarn level as well. However, there was still the possibility that the lever-arm test stand was causing the high scatter in data; specifically, due to potential variability in the loading of each specimen. Therefore, an additional creep test setup was designed and built to attempt to determine if the large scatter in the results was due to inherent material properties, the lever-arm test stand, or both. The newly designed creep test stand, henceforth known as the conventional test stand, utilized the more typical method for creep testing which involved hanging a weight from the yarn with no additional load amplification. The conventional test stand was designed and fabricated in-house at LaRC. High speed cameras were used to validate that the specimens in the conventional test stand failed in the gauge section. Once it was determined that the conventional test stand would provide valid failures in the gauge section, creep tests on the Vectran yarns were run to compare to the lever-arm test stand results. Preliminary results for a 70% UTS creep test have some specimens failing within a number of hours and some failing in excess of 6 weeks. These results are similar to those seen on the lever-arm test stand, pointing towards a large variability inherent in the material. The poster/presentation will focus on the design, fabrication, and validation of the conventional test stand as well as present preliminary results comparing the creep data from the conventional and lever-arm test stands

creep testing↗

Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study

This report details a study into the demand response potential of a large wastewater treatment facility in San Francisco. Previous research had identified wastewater treatment facilities as good candidates for demand response and automated demand response, and this study was conducted to investigate facility attributes that are conducive to demand response or which hinder its implementation. One years' worth of operational data were collected from the facility's control system, submetered process equipment, utility electricity demand records, and governmental weather stations. These data were analyzed to determine factors which affected facility power demand and demand response capabilities The average baseline demand at the Southeast facility was approximately 4 MW. During the rainy season (October-March) the facility treated 40% more wastewater than the dry season, but demand only increased by 4%. Submetering of the facility's lift pumps and centrifuges predicted load shifts capabilities of 154 kW and 86 kW, respectively, with large lift pump shifts in the rainy season. Analysis of demand data during maintenance events confirmed the magnitude of these possible load shifts, and indicated other areas of the facility with demand response potential. Load sheds were seen to be possible by shutting down a portion of the facility's aeration trains (average shed of 132 kW). Load shifts were seen to be possible by shifting operation of centrifuges, the gravity belt thickener, lift pumps, and external pump stations These load shifts were made possible by the storage capabilities of the facility and of the city's sewer system. Large load reductions (an average of 2,065 kW) were seen from operating the cogeneration unit, but normal practice is continuous operation, precluding its use for demand response. The study also identified potential demand response opportunities that warrant further study: modulating variable-demand aeration loads, shifting operation of sludge-processing equipment besides centrifuges, and utilizing schedulable self-generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

3D-FE Modeling of 316 SS under Strain-Controlled Fatigue Loading and CFD Simulation of PWR Surge Line

In financial year 2017, we are focusing on developing a mechanistic fatigue model of surge line pipes for pressurized water reactors (PWRs). To that end, we plan to perform the following tasks: (1) conduct stress- and strain-controlled fatigue testing of surge-line base metal such as 316 stainless steel (SS) under constant, variable, and random fatigue loading, (2) develop cyclic plasticity material models of 316 SS, (3) develop one-dimensional (1D) analytical or closed-form model to validate the material models and to understand the mechanics associated with 316 SS cyclic hardening and/or softening, (4) develop three-dimensional (3D) finite element (FE) models with implementation of evolutionary cyclic plasticity, and (5) develop computational fluid dynamics (CFD) model for thermal stratification, thermal-mechanical stress, and fatigue of example reactor components, such as a PWR surge line under plant heat-up, cool-down, and normal operation with/without grid-load-following. This semi-annual progress report presents the work completed on the above tasks for a 316 SS laboratory-scale specimen subjected to strain-controlled cyclic loading with constant, variable, and random amplitude. This is the first time that the accurate 3D-FE modeling of the specimen for its entire fatigue life, including the hardening and softening behavior, has been achieved. We anticipate that this work will pave the way for the development of a fully mechanistic-computer model that can be used for fatigue evaluation of safety-critical metallic components, which are traditionally evaluated by heavy reliance on time-consuming and costly test-based approaches. This basic research will not only help the nuclear reactor industry for fatigue evaluation of reactor components in a cost effective and less time-consuming way, but will also help other safety-related industries, such as aerospace, which is heavily dependent on test-based approaches, where a single full-scale fatigue test can cost millions of dollars and require years of effort to conduct. Toward our goal of demonstration of fully mechanistic fatigue evaluation of reactor components, we also started work on developing a component-level computer model of reactor components, such as 316 SS surge line pipe. This requires developing a thermal-mechanical stress analysis model of the reactor surge line, which, in turn, requires time-dependent temperature and stratification information along the boundary of the pipe. Toward that goal, CFD models of surge lines are being developed. In this report, we also present some preliminary results showing the temperature conditions along the surge line wall under reactor heat-up, cool-down, and steady-state power operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Load Deflection of Dow Corning SE 1700 Simple Cubic Direct Ink Write Materials: Effect of Thickness and Filament Spacing

Dow Corning SE 1700 (reinforced polydimethylsiloxane) porous structures were made by direct ink writing (DIW) in a simple cubic (SC) configuration. The filament diameter was 250 μm. Structures consisting of 4, 8, or 12 layers were fabricated with center-to-center filament spacing (“road width” (RW)) of 475, 500, 525, 550, or 575 μm. Three compressive load-unload cycles to 2000 kPa were performed on four separate areas of each sample; three samples of each thickness and filament spacing were tested. Geometry-dependent buckling of the SC structure was evident. At a given strain during the third loading phase, stress varied inversely with porosity. At strains of 25% and higher, the stress varied inversely with the number of layers (i.e., thickness); however, the relationship between stress and number of layers was more complex at lower strains. Intra-and inter-sample variability of the load deflection response was higher for thinner and less porous structures.

36 MATERIALS SCIENCE↗

Development of a Dynamic Model and Control System for Load-Following Studies of Supercritical Pulverized Coal Power Plants

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.

20 FOSSIL-FUELED POWER PLANTS↗

Application of the Concepts of Load State, Load Space, and Output Space to Strain-Gage Balances

The concepts of load state, load space, and output space are used to describe elements of the development of a load prediction process for a six–component strain–gage balance. The use of these terms adds clarity during the selection of the independent and dependent variables for the development of the load prediction process. First, the control volume model of a strain–gage balance is reviewed as it helps better understand the role of loads, outputs, and state variables during the load prediction. Then, the description of the absolute load datum in both the load space and the output space is discussed. It is concluded that the use of the difference between a raw output and the natural zero of a balance gage has a key advantage for the definition of the output space. In that case, the origin of the output space will also describe the absolute load datum of the balance. Finally, details of the application of the concepts of load state, load space, and output space to two commonly used balance load prediction methods are discussed.

strain-gage balance↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales inthe seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are largeenough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large (50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales in the seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are large enough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large ({approx}50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control: Preprint

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Battery Control Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric System Intra-hour Operation Simulator

ESIOS is a software program developed at Pacific Northwest National Laboratory (PNNL) that performs intra-hour dispatch and automatic generation control (AGC) simulations for electric power system frequency regulation and load/variable generation following. The program dispatches generation resources at minute interval to meet control performance requirements, while incorporating stochastic models of forecast errors and variability with generation, load, interchange and market behaviors. The simulator also contains an operator model that mimics manual actions to adjust resource dispatch and maintain system reserves. Besides simulating generation fleet intra-hour dispatch, ESIOS can also be used as a test platform for the design and verification of energy storage, demand response, and other technologies helping to accommodate variable generation.

Lu, Shuai↗