Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Mine Ventilation Rate Monitoring Annual Report

The NMED issued the WIPP HWFP, NM4890139088-TSDF, on October 27, 1999. In accordance with HWFP Condition IV.F.3.a, an MVRMP was developed and submitted to the NMED within ninety calendar days of the issuance of the HWFP. The MVRMP documents compliance with the ventilation requirements described in HWFP Condition IV.E.3.b and Section M2-2a(3) for airflow rates for the total underground repository and the active disposal room when workers are present. The HWFP also specifies that an annual report be submitted, beginning twelve months after the issuance of the permit, that describes the implementation of the MVRMP, and presents the results of the monitoring activities. This document was prepared to fulfill the annual reporting requirement for the period from July 1, 2006, to June 30, 2007.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mine Ventilation Rate Monitoring Annual Report

The NMED issued the WIPP HWFP, NM4890139088-TSDF, on October 27, 1999. In accordance with HWFP Condition IV.F.4.a, an MVRMP was developed and submitted to the NMED within ninety calendar days of the issuance of the HWFP. The MVRMP contains the methods for documenting compliance with the ventilation requirements described in HWFP Condition IV.E.3.b and Section M2-2a(3) for airflow rates for the total underground repository and the active disposal room when workers are present. The HWFP also specifies that an annual report be submitted, beginning twelve months after the issuance of the permit, that describes the implementation of the MVRMP, and presents the results of the monitoring activities. This document was prepared to fulfill the annual reporting requirement for the period from July 1, 2009, to June 30, 2010.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of measurements of ventilation-to-perfusion ratio inequality in the lung from expired gas

The analysis of the gas in a single expirate has long been used to estimate the degree of ventilation-perfusion (Va/Q) inequality in the lung. To further validate this estimate, we examined three measures of Va/Q inhomogeneity calculated from a single full exhalation in nine anesthetized mongrel dogs under control conditions and after exposure to aerosolized methacholine. These measurements were then compared with arterial blood gases and with measurements of Va/Q inhomogeneity obtained using the multiple inert gas elimination technique. The slope of the instantaneous respiratory exchange ratio (R slope) vs. expired volume was poorly correlated with independent measures, probably because of the curvilinear nature of the relationship due to continuing gas exchange. When R was converted to the intrabreath Va/Q (iV/Q), the best index was the slope of iV/Q vs. volume over phase III (iV/Q slope). This was strongly correlated with independent measures, especially those relating to inhomogeneity of perfusion. The correlations for iV/Q slope and R slope considerably improved when only the first half of phase III was considered. We conclude that a useful noninvasive measurement of Va/Q inhomogeneity can be derived from the intrabreath respiratory exchange ratio.

NASA Discipline Cardiopulmonary↗

Highlights of Aeroacoustic Tests of a Metal Spacecraft Cabin Ventilation Fan Prototype

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and tested in the NASA Glenn Research Center Acoustical Testing Laboratory. The fan design featured a low-noise blade-vane count that was chosen to reduce the rotor-stator interaction tone noise. The fan was throttled through its operating range, and results indicate that the measured aerodynamic and acoustic performance was in good agreement with predictions. Recommendations for further research of quiet high-performance fans intended to support long duration human space exploration missions are offered. This small fan aerodynamic and acoustic test rig and the NASA Glenn Acoustical Testing Laboratory are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Fan↗

Highlights of Aeroacoustic Tests of a Metal Spacecraft Cabin Ventilation Fan Prototype

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and tested in the NASA Glenn Research Center Acoustical Testing Laboratory. The fan design featured a low-noise blade-vane count that was chosen to reduce the rotor-stator interaction tone noise. The fan was throttled through its operating range, and results indicated that the measured aerodynamic and acoustic performance was in good agreement with predictions. Recommendations for further research of quiet high-performance fans intended to support long duration human space exploration missions are offered. This small fan aerodynamic and acoustic test rig and the NASA Glenn Acoustical Testing Laboratory are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Fan, Noise, Ventilation↗

Quiet Spacecraft Cabin Ventilation Fan: Vibration Measurements Results

Quiet, efficient fans with minimal vibrations are needed to maximize the mechanical life of atmospheric revitalization system fans used for human life support systems for long duration space exploration missions. Several metal spacecraft cabin ventilation fan prototypes have been designed, built, and tested at the NASA Glenn Research Center Acoustical Testing Laboratory. Tests performed in 2021 of the first prototype of the metal fan measured vibrations greater than desired at design point speed and backpressure conditions. To try to reduce those vibrations, a second prototype of the fan design was developed which included a new lighter rotor with a tighter balance tolerance, a new collet to attach the rotor to the motor shaft more securely and repeatably, and a new bracket to center and hold the motor in the fan centerbody more precisely. The second prototype of the fan was tested in 2023 and the vibrations were measured with the fan operating at design point speeds in isolation but not throttled to design point back pressure conditions since it was not installed with inlet and exhaust ducting. Peak vibration was reduced from 4 mm/s to 1 mm/s. This paper is part of a series of reports documenting the performance of the prototype fan.

Fan↗

Spacecraft Cabin Ventilation Fan: Wake Measurements Results

Quiet, efficient fans with minimal vibrations are required for revitalization system fans used for human support system in long duration space exploration missions. A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed in NASA Glenn research center. Two copies of the fan assembly were fabricated and tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot-wire measurements of the fan wake. Hot-wire measurements were obtained by radially traversing a x-wire probe downstream of the rotor. This report documents the phase-locked wake velocity, flow angle and turbulence measurements from the hot-wire surveys as part of a series of reports.

Hotwire Measurement↗

Quiet Spacecraft Cabin Ventilation Fan: Vibration Measurements Results

The vibrations of a metal spacecraft cabin ventilation fan that tested in 2021 were greater than desired. We diagnosed the problem and modified the rotor assembly in 2022 to try and reduce those vibrations. The design changes included a new lighter rotor with a tighter balance tolerance, a new collet to attach the rotor to the motor shaft more securely and repeatably, and a new bracket to center and hold the motor a little better. The redesigned rotor was tested in 2023 and vibrations were significantly reduced. The measured peak vibration was reduced from 4 mm/s second to less than 1 mm/s, corresponding to a reduction from a balance grade G4 to a grade G 0.6.

Fan, Noise, Ventilation↗

Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in) in diameter and 0.223 m (9.00 in) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.0709 m3/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 rpm to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

fan↗

The Trade-off between Solar Reflectance and Above-Sheathing Ventilation for Metal Roofs on Residential and Commercial Buildings

An alternative to white and cool-color roofs that meets prescriptive requirements for steep-slope (residential and non-residential) and low-slope (non-residential) roofing has been documented. Roofs fitted with an inclined air space above the sheathing (herein termed above-sheathing ventilation, or ASV), performed as well as if not better than high-reflectance, high-emittance roofs fastened directly to the deck. Field measurements demonstrated the benefit of roofs designed with ASV. A computer tool was benchmarked against the field data. Testing and benchmarks were conducted at roofs inclined at 18.34 ; the roof span from soffit to ridge was 18.7 ft (5.7 m). The tool was then exercised to compute the solar reflectance needed by a roof equipped with ASV to exhibit the same annual cooling load as that for a direct-to-deck cool-color roof. A painted metal roof with an air space height of 0.75 in. (0.019 m) and spanning 18.7 ft (5.7 m) up the roof incline of 18.34 needed only a 0.10 solar reflectance to exhibit the same annual cooling load as a direct-to-deck cool-color metal roof (solar reflectance of 0.25). This held for all eight ASHRAE climate zones complying with ASHRAE 90.1 (2007a). A dark heat-absorbing roof fitted with 1.5 in. (0.038 m) air space spanning 18.7 ft (5.7 m) and inclined at 18.34 was shown to have a seasonal cooling load equivalent to that of a conventional direct-to-deck cool-color metal roof. Computations for retrofit application based on ASHRAE 90.1 (1980) showed that ASV air spaces of either 0.75 or 1.5 in. (0.019 and 0.038 m) would permit black roofs to have annual cooling loads equivalent to the direct-to-deck cool roof. Results are encouraging, and a parametric study of roof slope and ASV aspect ratio is needed for developing guidelines applicable to all steep- and low-slope roof applications.

above sheathing ventilation↗

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

Improvement of a Chemical Storage Room Ventilation System

Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories, as well as structural improvements made to improve safety and security, to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. This manuscript is the third in a series of five case studies describing laboratory incidents, accidents, and laboratory improvements. We summarize an improvement to the chemical storage room ventilation system at Al-Nahrain University to create and maintain a safe working atmosphere in an area where chemicals are stored and handled, using US and European design practices, standards, and regulations.

chemistry laboratory↗

Utilization of ventilation air methane as a supplementary fuel at a circulating fluidized bed combustion boiler

Ventilation air methane (VAM) accounts for 60-80% of the total emissions from underground coal mining activities in China, which is of serious greenhouse gas concerns as well as a waste of valuable fuel sources. This contribution evaluates the use of the VAM utilization methods as a supplementary fuel at a circulating fluidized bed combustion boiler. The paper describes the system design and discusses some potential technical challenges such as methane oxidation rate, corrosion, and efficiency. Laboratory experimentation has shown that the VAM can be burnt completely in circulated fluidized bed furnaces, and the VAM oxidation does not obviously affect the boiler operation when the methane concentration is less than 0.6%. The VAM decreased the incomplete combustion loss for the circulating fluidized bed combustion furnace. The economic benefit from the coal saving insures that the proposed system is more economically feasible. 17 refs., 3 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗