Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Metamaterials program at Sandia National Laboratories.

Sandia National Laboratories Metamaterial Science and Technology Program has developed novel HPC-based design tools, wafer scale 3D fabrication processes, and characterization tools to enable thermal IR optical metamaterial application studies.

36 MATERIALS SCIENCE↗

Microstructure in the extreme environment: understanding and predicting dynamic damage processes

The future of materials science: strategic application for functionally controlled materials properties is emphasized by the need to control material performance in extreme environments. To this end, this study examines the separate effects of kinetics (in the form of dynamic loading rate and shock wave shape) from that of length-scale effects (in the form of microstructural defect distributions). Recently available mesoscale modeling techniques are being used to capture a physical link between kinetic and length-scale influences on dynamic loading. This work contributes innovative new tools in the form of shock-wave shaping techniques in dynamic experimentation, materials characterization, lending insight into 3D damage field analysis at micron resolution, and the physics necessary to provide predictive capabilities for dynamic damage evolution. Experimental results tailored for the discreet understanding of length-scale and kinetic effects during dynamic loading are obtained to provide the basis for the development of process-aware material performance models. The understanding of length-scale and kinetic effects in extreme environments of dynamic loading advances the understanding of current emerging issues relevant to phenomena such as inclusion related failure in metals, grain size dependence on ejecta, and benefits of interfaces in mitigating defect development specifically driven by the need to tailor material response. Finally, the coupling of experimental techniques with theory and simulation is aimed at advancing process-aware damage modeling as well as transitioning materials science from observation to property control.

36 MATERIALS SCIENCE↗

3D hierarchical Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O and Zn{sub 3}(VO{sub 4}){sub 2} microspheres: Synthesis, characterization and photoluminescence

Highlights: Black-Right-Pointing-Pointer 3D hierarchical microspheres of Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O were gained with glycine-assisted hydrothermal method. Black-Right-Pointing-Pointer Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O can be transformed into Zn{sub 3}(VO{sub 4}){sub 2} with the similar morphologies by calcination. Black-Right-Pointing-Pointer The PL properties of Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O and Zn{sub 3}(VO{sub 4}){sub 2} were studied. -- Abstract: Via a simple glycine-assisted hydrothermal route, large-scale 3D hierarchical Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O microspheres have been fabricated. Their purity, crystalline phase, morphologies and thermal stability were characterized by X-ray diffraction (XRD), X-ray photoelectron spectra (XPS), Fourier transform IR (FTIR), scanning electron microscopy (SEM) and thermogravimetry-differential scanning calorimetry (TG-DSC). The SEM results indicate that the microspheres are self-assembled by numerous nanoflakes with mean thickness of 100 nm. Some factors influencing the morphologies of the Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O micro-/nanostructures have been systematically investigated, as well as quantity of glycine and the reaction time. The possible mechanism of the crystal growth and assembled procedure were also proposed. The as-prepared Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O can be transformed into Zn{sub 3}(VO{sub 4}){sub 2} with the similar morphologies by calcination in air at 600 Degree-Sign C. Furthermore, the photoluminescent properties of both Zn{sub 3}(OH){sub 2}V{sub 2}O{sub 7}{center_dot}2H{sub 2}O and Zn{sub 3}(VO{sub 4}){sub 2} were studied and exhibited different spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of core asymmetries in inertial confinement fusion implosions using three-dimensional hot-spot reconstruction

Three-dimensional effects play a crucial role during the hot-spot formation in inertial confinement fusion (ICF) implosions. A data analysis technique for 3D hot-spot reconstruction from experimental observables has been developed to characterize the effects of low modes on 3D hot-spot formations. In nuclear measurements, the effective flow direction, governed by the maximum eigenvalue in the velocity variance of apparent ion temperatures, has been found to agree with the measured hot-spot flows for implosions dominated by mode ℓ = 1. Asymmetries in areal-density (ρR) measurements were found to be characterized by a unique cosine variation along the hot-spot flow axis. In x-ray images, a 3D hot-spot x-ray emission tomography method was developed to reconstruct the 3D hot-spot plasma emissivity using a generalized spherical-harmonic Gaussian function. The gradient-descent algorithm was used to optimize the mapping between the projections from the 3D hot-spot emission model and the measured x-ray images along multiple views. Furthermore, this work establishes a platform to analyze 3D low-mode core asymmetries in ICF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical verification of Orbit and Nemato codes for magnetic topology diagnosis

We present the results of a benchmark study involving the Orbit and Nemato codes. The two codes have been used to compare magnetic structure in a reversed-field pinch (RFP), where conserved magnetic structures/islands appear both in the core (dominated by m = 1 modes) and in the edge (dominated by m = 0 modes). As input, a snapshot of a 3D nonlinear MHD visco-resistive simulation (produced by the SpeCyl code) has been used. The first test is given by the reconstruction via Poincaré surface of section plot of an island generated by a single mode. In this case, the magnetic field topology corresponds to a time-independent Hamiltonian and shows conserved flux-surfaces used as a reference. Both codes successfully yield field lines which follow the same flux surfaces, in both the m = 1 and m = 0 cases. The benchmark between the codes has then been extended to a more complex configuration with chaotic magnetic field, using as input a fully 3D multiple mode RFP condition, characterized by the typical chain of edge magnetic islands providing a transport barrier. Finally, a quantitative benchmark has been performed, using the same 3D input, by estimating the correlation length of the magnetic field line in a bounded stochastic domain. The conclusion is that both codes yield consistent Poincaré plot structure on one hand, and very good quantitative agreement in correlation length estimate. This gives confidence to the application of both codes to magnetic topology in the RFX-mod device, for which they are used routinely, as well as for a generic fusion device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film planes. Measured and simulated PDD profiles agree within a root-mean-square difference of 1.3%. In-field film stack dosimeter and TLD measurements agree within 5%, and measurements in the field penumbra agree within 0.5 mm. Film stack dosimeter and TLD measurements have expanded (k = 2) overall measurement uncertainties of 6.2% and 5.8%, respectively. Film stack dosimeter measurements of an IMRT dose distribution have 98% agreement with the treatment planning system dose calculation, using gamma criteria of 3% and 2 mm. Conclusions: The film stack dosimeter is capable of high-resolution, low-uncertainty 3D dose measurements, and can be readily incorporated into an existing film dosimetry program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic inflammation in a mouse model. The authors’ evaluation considered three mice, two with an inflammation phenotype and one control. The authors’ iterative 3D histology reconstruction yielded a 70.1% ± 2.7% overlap with the ex vivo MRI volume. Across a total of 17 anatomic landmarks manually delineated at the division of airways, the target registration error between the ex vivo MRI and 3D histology reconstruction was 0.85 ± 0.44 mm, suggesting that a good alignment of the ex vivo 3D histology and ex vivo MRI had been achieved. The 3D histology-in vivo MRI coregistered volumes resulted in an overlap of 73.7% ± 0.9%. Preliminary computerized feature analysis was performed on an additional four control mice, for a total of seven mice considered in this study. Gabor texture filters appeared to best capture differences between the inflamed and noninflamed regions on MRI. Conclusions: The authors’ 3D histology reconstruction and multimodal registration framework were successfully employed to reconstruct the histology volume of the lung and fuse it with in vivo MRI to create a ground truth map for inflammation on in vivo MRI. The analytic platform presented here lays the framework for a rigorous validation of the identified imaging features for chronic lung inflammation on MRI in a large prospective cohort.

60 APPLIED LIFE SCIENCES↗

Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored, circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retroreflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

Pappa, Richard S.↗

Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retro- reflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

Black, Jonathan T.↗

Early Lessons on Combining Lidar and Multi‑baseline SAR Measurements for Forest Structure Characterization

The estimation and monitoring of 3D forest structure at large scales strongly rely on the use of remote sensing techniques. Today, two of them are able to provide 3D forest structure estimates: lidar and synthetic aperture radar (SAR) configurations. The differences in wavelength, imaging geometry, and technical implementation make the measurements pro-vided by the two configurations different and, when it comes to the sensitivity to individual 3D forest structure components, complementary. Accordingly, the potential of combining lidar and SAR measurements toward an improved 3D forest structure estimation has been recognised from the very beginning. However, until today there is no established frame-work for this combination. This paper attempts to review differences, commonalities, and complementarities of lidar and SAR measurements. First, vertical lidar reflectance and SAR reflectivity profiles at different wavelengths are compared in different forest types. Then, current perspectives on their combination for the generation of enhanced structure products are discussed. Two promising frameworks for combining lidar and SAR measurements are reviewed. The first one is a model-based framework where lidar-derived parameters are used to initialize SAR scattering models, and relies on both the validity of the models and on the physical equivalence of the used lidar and SAR parameters. The second one is a structure-based framework based on the ability of lidar and SAR measurements to express physical forest structure by means of appropriate indices. These indices can then be used to establish a link between the two kind of measurements. The review is supported by experimental results achieved using space- and airborne data acquired in recent relevant mission and campaigns.

Matteo Pardini↗

Three-dimensional (3D) visualization of reflow porosity and modeling of deformation in Pb-free solder joints

The volume, size, and dispersion of porosity in solder joints are known to affect mechanical performance and reliability. Most of the techniques used to characterize the three-dimensional (3D) nature of these defects are destructive. With the enhancements in high resolution computed tomography (CT), the detection limits of intrinsic microstructures have been significantly improved. Furthermore, the 3D microstructure of the material can be used in finite element models to understand their effect on microscopic deformation. In this paper we describe a technique utilizing high resolution (< 1 {mu}m) X-ray tomography for the three-dimensional (3D) visualization of pores in Sn-3.9Ag-0.7Cu/Cu joints. The characteristics of reflow porosity, including volume fraction and distribution, were investigated for two reflow profiles. The size and distribution of porosity size were visualized in 3D for four different solder joints. In addition, the 3D virtual microstructure was incorporated into a finite element model to quantify the effect of voids on the lap shear behavior of a solder joint. The presence, size, and location of voids significantly increased the severity of strain localization at the solder/copper interface.

36 MATERIALS SCIENCE↗

Reducing Artifacts in BF and HAADF-STEM Images of Pt/C Fuel Cells using MBIR-ARAR

Electron tomography is a powerful tool for characterization of three-dimensional (3D) nanoscale materials and devices. Bright-field (BF) and high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) are two widely used imaging modes in electron tomography. These imaging modalities have proven to be useful for characterizing the structure of carbon-supported platinum (Pt/C) electrocatalysts used in fuel cells, which are an important class of clean energy conversion systems. BF and HAADF-STEM images are typically simultaneously acquired due to the complementary information they contain, as BF-STEM is more suitable for characterizing carbon due to its ability to detect lighter elements, while HAADF-STEM is more suitable for characterizing platinum due to its sensitivity to atomic number. However, the quality of BF- and HAADF-STEM images is often compromised by various artifacts, such as local blurring due to abrupt contrast changes as well as missing wedge artifacts which can severely impact the accuracy of the reconstructed 3D images. The traditional methods of reconstruction, such as Filtered Back-projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT), and Model-Based Iterative Reconstruction (MBIR), are often not suitable for removing these artifacts effectively. Here, to address this challenge, we present a novel approach called MBIR with Artifact Reduction and Adaptive Regularization (MBIR-ARAR).

25 ENERGY STORAGE↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Local characterization of hindered Brownian motion by using digital video microscopy and 3D particle tracking

In this article we present methods for measuring hindered Brownian motion in the confinement of complex 3D geometries using digital video microscopy. Here we discuss essential features of automated 3D particle tracking as well as diffusion data analysis. By introducing local mean squared displacement-vs-time curves, we are able to simultaneously measure the spatial dependence of diffusion coefficients, tracking accuracies and drift velocities. Such local measurements allow a more detailed and appropriate description of strongly heterogeneous systems as opposed to global measurements. Finite size effects of the tracking region on measuring mean squared displacements are also discussed. The use of these methods was crucial for the measurement of the diffusive behavior of spherical polystyrene particles (505 nm diameter) in a microfluidic chip. The particles explored an array of parallel channels with different cross sections as well as the bulk reservoirs. For this experiment we present the measurement of local tracking accuracies in all three axial directions as well as the diffusivity parallel to the channel axis while we observed no significant flow but purely Brownian motion. Finally, the presented algorithm is suitable also for tracking of fluorescently labeled particles and particles driven by an external force, e.g., electrokinetic or dielectrophoretic forces.

74 ATOMIC AND MOLECULAR PHYSICS↗

RF Characterization of a Photocurable PEDOT:PSS:PEGDA Conductive Biomaterial for 3D-Printing Implantable Antennas

In this work, we demonstrate photocurable PEDOT:PSS:PEGDA biomaterial as a promising candidate for intracorporeal 3D printing. Intracorporeal 3D printing offers a less invasive method which offer flexibility to tailor the form factor of printed structures. Previous work has demonstrated the feasibility of a robotic probe to 3D-print biological tissues intracorporeally via a minor incision. This same probe could also 3D-print implantable antennas as long as a suitable conductive material is identified in terms of conductivity, biocompatibility, and ability to cure at room/body temperature for safety purposes. We assess the frequency-dependent conductivity of this biomaterial and explore the Radio-Frequency (RF) performance of resulting antennas operating in free-space and inside tissue-emulating phantoms. Results show that PEDOT:PSS biomaterial with 21% and 30% PEGDA content exhibit a conductivity of ~10 4 S/m up to 5 GHz, suitable for wireless implants. Comparing the two, 21% PEGDA content exhibits poorer curing abilities, while 30% PEGDA exhibits slightly lower conductivity. Measurements for 2.4 GHz free-space dipoles conducted in an anechoic chamber reveal only ~0.8 dB and ~1 dB lower gain for PEDOT:PSS:21%PEGDA and PEDOT:PSS:30%PEGDA biomaterial, respectively, as compared to their copper counterpart. For a 5 mm-deep implanted patch antenna, these two biomaterials exhibit 3.05 dB and 3.84 dB higher transmission loss than copper, respectively. If deemed necessary, this performance degradation can be overcome by increasing the overall antenna size since the printing process is now minimally invasive and miniaturization requirements can be relaxed.

3D-printing↗