Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Demonstration of Electrochemically-Driven CO 2 Separation Using Hydroxide Exchange Membranes

Hydroxide exchange membrane fuel cells (HEMFCs) are a potentially lower-cost hydrogen fuel cell technology; however, ambient levels of CO 2 in air significantly reduce HEMFCs’ performance. In this work, we demonstrate an electrochemically-driven CO 2 separator (EDCS) which can be used to remove ambient levels of CO 2 from air upstream of the HEMFC stack in fuel cell vehicles, protecting it from CO 2 -related performance losses. The EDCS operating window was explored for current density, anode flow, and cathode flow with respect to its impact on CO 2 separation performance. Additionally, gas-phase mass transport was improved by selecting flow fields and gas diffusion layers conducive to the EDCS operating regime. The use of a carbon-ionomer interlayer at the cathode was explored and improved CO 2 removal performance from 77.7% to 98.2% at 20 mA cm −2 . An analytical, 1-D model is used to explain the experimental observations and design improvements. A single-cell, 25 cm 2 EDCS using the aforementioned improved design demonstrated greater than 98% CO 2 removal at a cathode flow rate of 1300 sccm for 100 h with 2.7% hydrogen stack consumption.

Matz, Stephanie↗

Testing of Microchannels and Lab-Grown Stress Corrosion Cracks for Quantification of Aerosol Transmission

The formation of a stress corrosion crack (SCC) in the canister wall of a dry cask storage system (DCSS) has been identified as a potential issue for the long-term storage of spent nuclear fuel. The presence of an SCC in a storage system could represent a through-wall flow path from the canister interior to the environment. Modern, vertical DCSSs are of particular interest due to the commercial practice of using higher backfill pressures in the canister, up to approximately 800 kPa, compared to their horizontal counterparts. This pressure differential offers a relatively high driving potential for blowdown of any particulates that might be present in the canister. In this study, the rates of gas flow and aerosol transmission of a spent fuel surrogate through an engineered microchannel with dimensions representative of an SCC were evaluated experimentally using coupled mass flow and aerosol analyzers. The microchannel was formed by mating two gage blocks with a linearly tapering slot orifice nominally 13 μm (0.005 in.) tall on the upstream side and 25 μm (0.0010 in.) tall on the downstream side. The orifice is 12.7 mm (0.500 in.) wide by 8.86 mm (0.349 in.) long (flow length). Surrogate aerosols of cerium oxide, CeO 2 , were seeded and mixed with either helium or air inside a pressurized tank. The aerosol characteristics were measured immediately upstream and downstream of the simulated SCC at elevated and ambient pressures, respectively. These data sets are intended to add to previous testing that characterized SCCs under well-controlled boundary conditions through the inclusion of testing improvements that establish initial conditions in a more consistent way. While the engineered microchannel has dimensions similar to actual SCCs, it does not reproduce the tortuous path the aerosol laden flow would have to traverse for eventual transmission. SCCs can be rapidly grown in a laboratory setting given the right conditions, and initial characterization and clean-flow testing has begun on lab grown crack samples provided to Sandia National Laboratories (SNL). Many such samples are required to produce statistically relevant transmission results, and SNL is developing a procedure to produce samples in welded steel plates. These ongoing testing efforts are focused on understanding the evolution in both size and quantity of a hypothetical release of aerosolized spent fuel particles from failed fuel to the canister interior and ultimately through an SCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-modal chemical characterization of highly viscous submicrometer organic particles

Distinguishing highly viscous organic particles within complex mixtures of atmospheric aerosol and accurate descriptions of their composition, size distributions, and mixing states are challenges at the forefront of aerosol measurement science and technology. Here, we present results obtained from complementary single-particle measurement techniques employed for the in-depth characterization of highly viscous particles. In this study, we demonstrate advantages and synergy of this multi-modal particle characterization approach based on the analysis of individual viscous particles formed in the air-discharged waste produced by a common sewer pipe rehabilitation technology. Using oil immersion flow microscopy, we investigate particle size distributions and morphology of colloidal components present in field-collected aqueous waste condensates. We compare these results with corresponding measurements of viscous particles formed in drying droplets of the aerosolized discharged waste. The colloidal components and viscous particles were found to be approximately 10 µm and 0.5 µm, respectively. The aerosolized viscous particles exhibited a spherical morphology, while the colloidal particles appeared noticeably fractal, resembling fragments of a cured composite material. Chemical imaging of the viscous particles collected on substrates was performed using scanning electron microscopy and soft X-ray spectro-microscopy techniques. Through these methods, comprehensive description of these particles emerged, confirming their high solid-like viscosity, wide-ranging sizes, diverse carbon speciation with high degrees of oxygenation, and high organic volume fractions. The aerosolized viscous particles were further characterized using high-throughput single particle mass spectrometry. This technique provides real-time measurements of composition, size, and morphological metrics for large numbers of individual particles, enabling the identification of their distinct mass spectrometric signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deforestation reshapes land-surface energy-flux partitioning

Land-use and land-cover change significantly modify local land-surface characteristics and water/energy exchanges, which can lead to atmospheric circulation and regional climate changes. In particular, deforestation accounts for a large portion of global land-use changes, which transforms forests into other land cover types, such as croplands and grazing lands. Many previous efforts have focused on observing and modeling land–atmosphere–water/energy fluxes to investigate land–atmosphere coupling induced by deforestation. However, interpreting land–atmosphere–water/energy-flux responses to deforestation is often complicated by the concurrent impacts from shifts in land-surface properties versus background atmospheric forcings. In this study, we used 29 paired FLUXNET sites, to improve understanding of how deforested land surfaces drive changes in surface-energy-flux partitioning. Each paired sites included an intact forested and non-forested site that had similar background climate. We employed transfer entropy, a method based on information theory, to diagnose directional controls between coupling variables, and identify nonlinear cause–effect relationships. Transfer entropy is a powerful tool to detective causal relationships in nonlinear and asynchronous systems. The paired eddy covariance flux measurements showed consistent and strong information flows from vegetation activity (gross primary productivity (GPP)) and physical climate (e.g. shortwave radiation, air temperature) to evaporative fraction (EF) over both non-forested and forested land surfaces. More importantly, the information transfers from radiation, precipitation, and GPP to EF were significantly reduced at non-forested sites, compared to forested sites. We then applied these observationally constrained metrics as benchmarks to evaluate the Energy Exascale Earth System Model (E3SM) land model (ELM). ELM predicted vegetation controls on EF relatively well, but underpredicted climate factors on EF, indicating model deficiencies in describing the relationships between atmospheric state and surface fluxes. Moreover, changes in controls on surface energy flux partitioning due to deforestation were not detected in the model. We highlight the need for benchmarking model simulated surface-energy fluxes and the corresponding causal relationships against those of observations, to improve our understanding of model predictability on how deforestation reshapes land surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and material selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including Colmonoy grades, Stellite grades, and a novel Nickel Tungsten Carbide alloy (HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the molten salt. The pump wetted components are made of Inconel 625 and features a carbon ring seal (CIRPAC Seal) flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. A comprehensive pump test program has been completed. Over 90 hours run time pumping hot chloride salts at temperatures up to 720 °C in which enough data was captured to produce performance curves at 3 different operating speeds. This research showcases a promising design for use in the Concentrated Solar Power (CSP) Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

14 SOLAR ENERGY↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

AIR Algebraic Multigrid for a Space-Time Hybridizable Discontinuous Galerkin Discretization of Advection(-Diffusion)

This article investigates the efficiency, robustness, and scalability of approximate ideal restriction (AIR) algebraic multigrid as a preconditioner in the all-at-once solution of a space-time hybridizable discontinuous Galerkin discretization of advection-dominated flows. The motivation for this study is that the time-dependent advection-diffusion equation can be seen as a “steady” advection-diffusion problem in $(d+1)$-dimensions and AIR has been shown to be a robust solver for steady advection-dominated problems. Numerical examples demonstrate the effectiveness of AIR as a preconditioner for advection-diffusion problems on fixed and time-dependent domains, using both slab-by-slab and all-at-once space-time discretizations, and in the context of uniform and space-time adaptive mesh refinement. A closer look at the geometric coarsening structure that arises in AIR also explains why AIR can provide robust, scalable, space-time convergence on advective and hyperbolic problems, while most multilevel parallel-in-time schemes struggle with such problems.

97 MATHEMATICS AND COMPUTING↗

Experimental and computational investigation of the influence of iso -butanol on autoignition of n -decane and n -heptane in non-premixed flows

Experimental and computational investigation is carried out to elucidate the influence of iso-butanol on critical conditions of autoignition of n-decane and n-heptane. The counterflow configuration is employed. In this configuration an axisymmetric stream of air is directed over the surface of an evaporating pool of a liquid fuel. A stagnation plane is established. The temperature of the air is increased until autoignition is achieved in the mixing layer in the vicinity of the stagnation plane. The temperature of the air stream at autoignition, T ig , is measured at various values of the strain rate, which is defined as the axial gradient of the axial component of the flow velocity at the stagnation plane. Fuels tested are n-decane, n-heptane, iso-butanol and various mixtures of n-decane/iso-butanol and n-heptane/iso-butanol. Kinetic modeling is carried out using the recently updated version of the comprehensive CRECK chemical-kinetic mechanism. Critical conditions of autoignition are predicted for all fuels and fuel mixtures and the results are compared with the measurements. Computations show that low-temperature chemistry plays a significant role in promoting autoignition of n-decane and n-heptane, and the influence of low-temperature chemistry decreases with increasing strain rates because there is insufficient residence for the low-temperature reactions to take place. Experimental data and numerical simulations show that addition of even small amounts of iso-butanol to n-decane or n-heptane increases the value of T ig at low strain rates indicating that iso-butanol strongly inhibits the low-temperature chemistry of n-decane and n-heptane. Furthermore, the simulations show that when iso-butanol is present in the liquid fuel, only a small amount of n-decane is available in the gas phase and its low concentration cannot effectively sustain the low temperature degenerate branching oxidation process. Here, predicted flame structures show that the peak values of mole fraction of ketohydroperoxide are significantly reduced when iso-butanol is added to n-decane indicating that the kinetic pathway to low temperature ignition is blocked. This observation is confirmed from sensitivity analysis.

42 ENGINEERING↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

“Hybridizing heat-integrated 3D printed modules with mass manufacturable, low pressure drop fiber sorbents” (Final Report)

The overall objective of this proposal was to research, develop, and evaluate a modular direct air capture (DAC) system that is simple and scalable. This system was based on the adsorption of CO 2 into commercial polyamines supported by porous fiber sorbents, which can be produced at kilometer per hour scales using our pre-pilot spinning line. We have housed these fiber materials in novel 3D printed modular housing systems that provide easy-to-manufacture and localized heat integration and flow control. This hybridization of fiber sorbent technology with modular housing provided several advantages that led to lower air pressure drops, higher sorbent productivity, as well as ease of manufacturing and assembly unrivaled by existing and emerging heat integrated contactor designs. The modular housing was fabricated with the following features, at a minimum: (i) a tapered air intake to reduce pressure drop related to entrance effects, (ii) a structured network of heat transfer channels to enable localized cooling and heating during adsorption and desorption, respectively, and (iii) low pressure drop supports for the fiber sorbents. This hybrid manufacturing approach provides a facile method for taking fiber sorbents from lab scale to pilot scale as it dramatically simplifies the fabrication of heat integrated contactor structures.

42 ENGINEERING↗

Experiments and CFD simulation of mass transfer and hydrodynamics in a cylindrical bubble column

Flow visualization, Particle Image Velocimetry (PIV) and dissolved oxygen charging experiments are carried out in a small-scale cylindrical air-water bubble column at different superficial gas velocities. Void fraction profile, total gas holdup, liquid phase velocity field and volumetric mass transfer coefficient are obtained. Details of each experiment are given, with a new procedure for obtaining a 2D void fraction profile from flow visualization by image processing and time averaging which could provide useful information for CFD model validation. The experimental results are analyzed and compared with simulations where good agreement is found for both local and global flow patterns. The averaged governing equations and constitutive relations used in the simulation are discussed briefly, with emphasis on the proper comparison between simulations and experiments based on the derivation of the two-fluid model. Finally, by conducting three sets of experiments related to phase distribution, velocity field and mass transfer in the same apparatus, a validated CFD model for multiphase mass transfer is established and can be used in the future design of a multi-phase reactor.

42 ENGINEERING↗