Search NASA⌕ Search

SEARCH · Search NASA

Results for “AXIAL RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen induced circumferential distortions of 90 degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

Experimental Investigation of Stage Performance of J71 Three-stage Turbine

An experimental investigation of the stage performance of the J71 three-stage turbine at design speed and pressure ratio was conducted as part of a program involving research on the design and operational characteristics of high-work-output multistage axial-flow turbines. The investigation indicated that the over-all work output of the turbine based on temperature measurements at design speed and pressure ratio was 95 percent of the design value, with the greatest loss in work output and efficiency occurring in the first stage. Choking in the second-stage stator over most of the pressure ratios investigated prevented the attainment of design first-stage work output and also prevented any increase in work output of the first stage with increasing over-all pressure ratio at design speed. High losses in the first stage were a contributing factor to this choking condition.

Forrette, Obert E↗

Internal low Reynolds number turbulent heat transfer

The results of a semi-analytical and experimental study of adiabatic tube flow and an analytical and experimental investigation of the thermal entrance region for gas flowing through electrically heated circular tubes are presented. Emphasis is placed on the low Reynolds number turbulent flow regime--defined as fully turbulent flow at bulk Reynolds numbers from 3,000 to about 15,000. Adiabatic air velocity and friction data and localized heat transfer measurements for air and helium, at low heating rates, are presented for this range. The adiabatic data were obtained in a 1.61 inch 1D tube for flow at bulk Reynolds numbers from 3,000 to 15,000. A continuous, Reynolds number-dependent, profile is developed from the data by using a modification of Reichardts' wall and middle law eddy diffusivity expressions. The velocity profile satisfies continuity. It is valid for all Reynolds numbers in excess of 3,000 for which the flow is fully turbulent and the Blasius friction factor expression is valid. The thermal entrance problem for a fully developed velocity profile is solved analytically by the method of Sparrow, Hallman, and Siegel. The solution is based on the profile developed from the velocity study. Tabular values of the eigenvalues and normalized Nusselt numbers for gases are presented for it range of Reynolds numbers from 3,000 to 50,000. The axial variation of Nusselt number is found to be correlated by [Nu/Nu_(∞)] = 1 + 0.8 (1+ 70,000 Re^(-3/2)) ((x/D)^(-1)) to within ± 5 per cent for x/D ≥2. The fully developed value agrees with the Dittus - Boelter correlation, Nu_(∞) = 0.021 Re^(0.8) Pr^(0.4) For the eigenvalues, λ^(2)_(n), and the associated constants, A_(n), correlations of the form λ^(2)_(n) =A_(1,n) Re^(-b_(1,n) + C_(1,n) Re^(-d_(1,n)) A_(n) = -A_(2,n) Re^(-b_(2,n) + C_(2,n) Re^(-d_(2,n)) are obtained. The coefficients and powers are presented in tabular form. Heat transfer data are presented, primarily for helium, for the low Reynolds number turbulent range. A one-quarter inch, resistively heated, vertical, circular tube was used for the study. The data cover an axial range from 1.2 to 96 diameters; wall-to-bulk temperature ratios vary from 1 to 1.4. In the low Reynolds number turbulent regime, these data clearly support the present analytical solution rather than the prediction obtained by applying the eddy diffusivity distribution used by Sparrow, Hallman, and Siegel.

Harold C. Reynolds, Jr.↗

Two-stage fan. 3: Data and performance with rotor tip casing treatment, uniform and distorted inlet flows

A two stage fan with a 1st-stage rotor design tip speed of 1450 ft/sec, a design pressure ratio of 2.8, and corrected flow of 184.2 lbm/sec was tested with axial skewed slots in the casings over the tips of both rotors. The variable stagger stators were set in the nominal positions. Casing treatment improved stall margin by nine percentage points at 70 percent speed but decreased stall margin, efficiency, and flow by small amounts at design speed. Treatment improved first stage performance at low speed only and decreased second stage performance at all operating conditions. Casing treatment did not affect the stall line with tip radially distorted flow but improved stall margin with circumferentially distorted flow. Casing treatment increased the attenuation for both types of inlet flow distortion.

Burger, G. D.↗

Experimental Vibration Damping Characteristics of the Third-stage Rotor of a Three-stage Transonic Axial-flow Compressor

Rotor blade aerodynamic damping is experimentally determined in a three-stage transonic axial flow compressor having design aerodynamic performance goals of 4.5:1 pressure ratio and 65.5 lbm/sec weight flow. The combined damping associated with each mode is determined by a least squares fit of a single degree of freedom system transfer function to the nonsynchronous portion of the rotor blade strain gage output power spectra. The combined damping consists of the aerodynamic damping and the structural and mechanical damping. The aerodynamic damping varies linearly with the inlet total pressure for a given corrected speed, weight flow, and pressure ratio while the structural and mechanical damping is assumed to remain constant. The combined damping is determined at three inlet total pressure levels to obtain the aerodynamic damping. The third-stage rotor blade aerodynamic damping is presented and discussed for the design equivalent speed with the stator blades reset for maximum efficiency. The compressor overall preformance and experimental Campbell diagrams for the third-stage rotor blade row are also presented.

Newman, Frederick A.↗

Experimental Determination of Aerodynamic Damping in a Three-Stage Transonic Axial-Flow Compressor

Rotor blade aerodynamic damping is experimentally determined in a three-stage transonic axial flow compressor having design aerodynamic performance goals of 4.5:1 pressure ratio and 65.5 lbm/sec weight flow. The combined damping associated with each mode is determined by a least squares fit of a single degree of freedom system transfer function to the nonsynchronous portion of the rotor blade strain gauge output power spectra. The combined damping consists of aerodynamic and structural and mechanical damping. The aerodynamic damping varies linearly with the inlet total pressure for a given equivalent speed, equivalent mass flow, and pressure ratio while structural and mechanical damping are assumed to be constant. The combined damping is determined at three inlet total pressure levels to obtain the aerodynamic damping. The third stage rotor blade aerodynamic damping is presented and discussed for 70, 80, 90, and 100 percent design equivalent speed. The compressor overall performance and experimental Campbell diagrams for the third stage rotor blade row are also presented.

Newman, Frederick A.↗

Experimental vibration damping characteristics of the third-stage rotor of a three-stage transonic axial-flow compressor

Rotor blade aerodynamic damping is experimentally determined in a three-stage transonic axial flow compressor having design aerodynamic performance goals of 4.5:1 pressure ratio and 65.5 lbm/sec weight flow. The combined damping associated with each mode is determined by a least squares fit of a single degree of freedom system transfer function to the nonsynchronous portion of the rotor blade strain gage output power spectra. The combined damping consists of the aerodynanmic damping and the structural and mechanical damping. The aerodynamic damping varies linearly with the inlet total pressure for a given corrected speed, weight flow, and pressure ratio while the structural and mechanical damping is assumed to remain constant. The combined damping is determined at three inlet total pressure levels to obtain the aerodynamic damping. The third-stage rotor blade aerodynamic damping is presented and discussed for the design equivalent speed with the stator blades reset for maximum efficiency. The compressor overall performance and experimental Campbell diagrams for the third-stage rotor blade row are also presented.

Newman, Frederick A.↗

Eccentricity effects upon the flow field inside a whirling annular seal

The flow field inside a whirling annular seal operating at a Reynolds number of 24,000 and a Taylor number of 6600 has been measured using a 3-D laser Doppler anemometer system. Two eccentricity ratios were considered, 0.10 and 0.50. The seal has a diameter of 164 mm, is 37.3 mm long, and has a clearance of 1.27 mm. The rotor was mounted eccentrically on the shaft such that the whirl ratio is 1.0 and the rotor follows a circular orbit. The mean axial velocity is not uniform around the circumference of the seal; near the inlet a region characterized by high velocity of the seal. By the exit, another region of high axial velocity is not uniform around the circumference of the seal; near the inlet a region characterized by high velocity of the seal. By the exit, another region of high axial velocity has developed, this time on the suction side of the seal. The magnitude and azimuthal distance of the migration increased with increasing whirl amplitude (eccentricity). Throughout the seal length, the azimuthal mean velocity varied inversely with the mean axial velocity. Increasing the whirl amplitude did not increase the magnitude of the azimuthal velocity at the seal exit.

Morrison, Gerald L.↗

The investigation of the mechanical properties of thermoviscoelastic material

An image moire method is used to determine Poisson's ratio for PMMA at different temperatures. A uniaxial tensile specimen is strained axially to a constant strain, and the lateral strain and the axial strain are monitored by a period photographic record. Simultaneous recording of the tensile stress yields the Young's modulus in relaxation and the corresponding Poisson effect. The test temperatures range from room temperature to 125 C. The data are then used to deduce the bulk relaxation moduli.

Knauss, W. G.↗

Mixing of Multiple Jets with a Confined Subsonic Crossflow in a Cylindrical Duct

This paper summarizes NASA-supported experimental and computational results on the mixing of a row of jets with a confined subsonic crossflow in a cylindrical duct. The studies from which these results were derived investigated flow and geometric variations typical of the complex 3-D flowfield in the combustion chambers in gas turbine engines. The principal observations were that the momentum-flux ratio and the number of orifices were significant variables. Jet penetration was critical, and jet penetration decreased as either the number of orifices increased or the momentum-flux ratio decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the number of orifices was proportional to the square-root of the momentum-flux ratio. In the cylindrical geometry, planar variances are very sensitive to events in the near wall region, so planar averages must be considered in context with the distributions. The mass-flow ratios and orifices investigated were often very large (mass-flow ratio greater than 1 and ratio of orifice area-to-mainstream cross-sectional area up to 0.5), and the axial planes of interest were sometimes near the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations. The results shown also seem to indicate that non-reacting dimensionless scalar profiles can emulate the reacting flow equivalence ratio distribution reasonably well. The results cited suggest that further study may not necessarily lead to a universal 'rule of thumb' for mixer design for lowest emissions, because optimization will likely require an assessment for a specific application.

Holdeman, James D.↗

Performance Study of a Ducted Fan System

An experimental investigation was completed in the NASA Ames 7- by 10-Foot Wind Tunnel with the objective of determining the performance characteristics of a ducted fan. The model was an annular duct with a 38-in diameter, 10-in chord, and a 5-bladed fixed-pitch fan. Model variations included duct angle of attack, exit vane flap length, flap deflection angle, and duct chord length. Duct performance data were obtained for axial and forward flight test conditions. Axial flow test data showed figure of merit decreases with increasing advance ratio. Forward flight data showed an increasing propulsive force with decreasing duct angle of attack. Exit vane flap deflection angle and flap chord length were shown to be an effective way of providing side force. Extending the duct chord did not effect the duct performance.

Abrego, Anita I.↗

Flow visualization of secondary flows in three curve ducts

Streak photography flow measurements are made for secondary flows in three 90-deg curved ducts of square cross section and different radii of curvature, at Dean numbers of 15,000-36,000 and radius ratios of 0.5, 2.3, and 3.0. Attention is given to secondary flow patterns for three cross sections in each bend: the inlet zero-deg plane, the midpoint 45-deg plane, and the outlet 90-deg plane. After a rapid transition region, the pressure-driven secondary flow patterns were characterized by flow moving toward the outer curved wall at the axial midplane and returning to the inner wall along the duct walls. The 0.5-radius ratio elbow was found to have the greatest influence on upstream inlet conditions.

Sanz, G. M.↗

DEVELOPMENT OF DESIGN STRENGTH LEVELS FOR THE ELASTIC STABILITY OF MONOCOQUE CONES UNDER AXIAL COMPRESSION

Design relationships have been derived for the determination of elastic buckling strength levels for unpressurized monocoque truncated cones under axial compression. Theoretical implications have been considered in the establishment of a semi-empirical analysis leading to the development of probability based design expressions. Data from 170 tests by various investigators were statistically evaluated for the expected mean, 90%, and 99% probability strength levels. Dispersion of data was found to be slightly less than that of monocoque cylinders. Non-linear effects of radius to thickness ratio or strength deterioration with length to radius ratio were not discernible.

AXIAL COMPRESSION↗

Low Velocity Difference Thermal Shear Layer Mixing Rate Measurements

Current CFD modeling techniques are known to do a poor job of predicting the mixing rate and persistence of slot film flow in co-annular flowing ducts with relatively small velocity differences but large thermal gradients. A co-annular test was devised to empirically determine the mixing rate of slot film flow in a constant area circular duct (D approx. 1ft, L approx. 10ft). The axial rate of wall heat-up is a sensitive measure of the mixing rate of the two flows. The inflow conditions were varied to simulate a variety of conditions characteristic of moderate by-pass ratio engines. A series of air temperature measurements near the duct wall provided a straightforward means to measure the axial temperature distribution and thus infer the mixing rate. This data provides a characterization of the slot film mixing rates encountered in typical jet engine environments. The experimental geometry and entrance conditions, along with the sensitivity of the results as the entrance conditions vary, make this a good test for turbulence models in a regime important to modern air-breathing propulsion research and development.

Bush, Robert H.↗

Compressor Study to Meet Large Civil Tilt Rotor Engine Requirements

A vehicle concept study has been made to meet the requirements of the Large Civil Tilt Rotorcraft vehicle mission. A vehicle concept was determined, and a notional turboshaft engine system study was conducted. The engine study defined requirements for the major engine components, including the compressor. The compressor design-point goal was to deliver a pressure ratio of 31:1 at an inlet weight flow of 28.4 lbm/sec. To perform a conceptual design of two potential compressor configurations to meet the design requirement, a mean-line compressor flow analysis and design code were used. The first configuration is an eight-stage axial compressor. Some challenges of the all-axial compressor are the small blade spans of the rear-block stages being 0.28 in., resulting in the last-stage blade tip clearance-to-span ratio of 2.4%. The second configuration is a seven-stage axial compressor, with a centrifugal stage having a 0.28-in. impeller-exit blade span. The compressors conceptual designs helped estimate the flow path dimensions, rotor leading and trailing edge blade angles, flow conditions, and velocity triangles for each stage.

Veres, Joseph P.↗

Extended magnetohydrodynamics simulations of thin-foil Z-pinch implosions with comparison to experiments

Cylindrical foil liners, with foil thicknesses on the order of 400 nm, are often used in university-scale Z-pinch experiments (~1 MA in 100 ns) to study physics relevant to inertial confinement fusion efforts on larger-scale facilities (e.g., the MagLIF effort on the 25-MA Z facility at Sandia National Laboratories). The use of ultrathin foil liners typically requires a central support rod to maintain the structural integrity of the liner target assembly prior to implosion. The radius of this support rod sets a limit on the maximum convergence ratio achievable for the implosion. In recent experiments with a support rod and a preimposed axial magnetic field, helical instability structures in the imploding foil plasma were found to persist as the foil plasma stagnated on the rod and subsequently expanded away from the rod. We have now used the 3D extended magnetohydrodynamics simulation code PERSEUS (which includes Hall physics) to study these experiments. The results suggest that it is the support rod which is responsible for the helical structures persisting beyond stagnation. Furthermore, we find that as the radius of the support rod decreases (i.e., as the convergence ratio increases), the integrity and persistence of the helical modes diminish. In the limit with no support rod, we find that the structure of the final stagnation column is governed by the structure of the central precursor plasma column. Furthermore, these simulation results and their comparisons to experiment are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗