Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

REDEX - The ranging equipment diagnostic expert system

REDEX, an advanced prototype expert system that diagnoses hardware failures in the Ranging Equipment (RE) at NASA's Ground Network tracking stations is described. REDEX will help the RE technician identify faulty circuit cards or modules that must be replaced, and thereby reduce troubleshooting time. It features a highly graphical user interface that uses color block diagrams and layout diagrams to illustrate the location of a fault. A semantic network knowledge representation technique was used to model the design structure of the RE. A catalog of generic troubleshooting rules was compiled to represent heuristics that are applied in diagnosing electronic equipment. Specific troubleshooting rules were identified to represent additional diagnostic knowledge that is unique to the RE. Over 50 generic and 250 specific troubleshooting rules have been derived. REDEX is implemented in Prolog on an IBM PC AT-compatible workstation. Block diagram graphics displays are color-coded to identify signals that have been monitored or inferred to have nominal values, signals that are out of tolerance, and circuit cards and functions that are diagnosed as faulty. A hypertext-like scheme is used to allow the user to easily navigate through the space of diagrams and tables. Over 50 graphic and tabular displays have been implemented. REDEX is currently being evaluated in a stand-alone mode using simulated RE fault scenarios. It will soon be interfaced to the RE and tested in an online environment. When completed and fielded, REDEX will be a concrete example of the application of expert systems technology to the problem of improving performance and reducing the lifecycle costs of operating NASA's communications networks in the 1990s.

Luczak, Edward C.↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗

Electrical Transport Experiments at High Pressure

High-pressure electrical measurements have a long history of use in the study of materials under ultra-high pressures. In recent years, electrical transport experiments have played a key role in the study of many interesting high pressure phenomena including pressure-induced superconductivity, insulator-to-metal transitions, and quantum critical behavior. High-pressure electrical transport experiments also play an important function in geophysics and the study of the Earth's interior. Besides electrical conductivity measurements, electrical transport experiments also encompass techniques for the study of the optoelectronic and thermoelectric properties of materials under high pressures. In addition, electrical transport techniques, i.e., the ability to extend electrically conductive wires from outside instrumentation into the high pressure sample chamber have been utilized to perform other types of experiments as well, such as high-pressure magnetic susceptibility and de Haas-van Alphen Fermi surface experiments. Finally, electrical transport techniques have also been utilized for delivering significant amounts of electrical power to high pressure samples, for the purpose of performing high-pressure and -temperature experiments. Thus, not only do high-pressure electrical transport experiments provide much interesting and valuable data on the physical properties of materials extreme compression, but the underlying high-pressure electrical transport techniques can be used in a number of ways to develop additional diagnostic techniques and to advance high pressure capabilities.

58 GEOSCIENCES↗

Diagnostics for first plasma and development plan on KSTAR

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An updated technique to obtain explosive kinetics data on microsecond timescales

There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ~1000 K on microsecond timescales. Wenograd loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Discovery Science and Inertial Fusion Energy Research at the Jupiter Laser Facility (Research Performance Progress Report)

The goal of this project is to provide operational support to run the Jupiter Laser Facility within the LaserNetUS network to achieve the following four objectives: • Develop new science, techniques, and platforms for discovery science and IFE research, in partnership with academia, other LaserNetUS nodes, and the greater community. • Advance the development of secondary sources of photons and particles for applications relevant to discovery science and IFE; • Serve as a testbed for new laser, optical, target, and diagnostic capabilities that will advance IFE; • Attract, train, and retain talent in high-energy-density and laser science that will be essential in furthering development of IFE, and help build new collaborations between national laboratory and academic researchers. We have accomplished our four objectives by: • Providing access to the three JLF platforms (Titan, Janus, and COMET) to LaserNetUS users after their proposals have been independently reviewed and ranked by the LaserNetUS PRP; • Providing expertise and technical capabilities to support focused science research thrusts at the facility; • Promoting and maintaining technical relationships and collaborations with other members of the LaserNetUS community to nurture and grow the discovery science and IFE workforce— especially students and early career scientists—on LaserNetUS facilities. • Augmenting JLF with specific improvements while coordinating efforts with LLNL organizations and collaborators to provide users with optimal laser, target, and diagnostic resources to help them maximize technical impact.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Goes-R Geostationary Lightning Mapper (GLM)

The Geostationary Operational Environmental Satellite (GOES-R) is the next series to follow the existing GOES system currently operating over the Western Hemisphere. Superior spacecraft and instrument technology will support expanded detection of environmental phenomena, resulting in more timely and accurate forecasts and warnings. Advancements over current GOES capabilities include a new capability for total lightning detection (cloud and cloud-to-ground flashes) from the Geostationary Lightning Mapper (GLM), and improved storm diagnostic capability with the Advanced Baseline Imager. The GLM will map total lightning activity (in-cloud and cloud-to-ground lighting flashes) continuously day and night with near-uniform spatial resolution of 8 km with a product refresh rate of less than 20 sec over the Americas and adjacent oceanic regions. This will aid in forecasting severe storms and tornado activity, and convective weather impacts on aviation safety and efficiency. In parallel with the instrument development, a GOES-R Risk Reduction Team and Algorithm Working Group Lightning Applications Team have begun to develop the Level 2 algorithms, cal/val performance monitoring tools, and new applications. Proxy total lightning data from the NASA Lightning Imaging Sensor on the Tropical Rainfall Measuring Mission (TRMM) satellite and regional test beds are being used to develop the pre-launch algorithms and applications, and also improve our knowledge of thunderstorm initiation and evolution. In this paper we will report on new Nowcasting and storm warning applications being developed and evaluated at various NOAA Testbeds.

Goodman, Steven J.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Deciphering the Cathode-Electrolyte Interfacial Chemistry in Sodium Layered Cathode Materials

The ever–increasing demand for stationary energy storage has driven the prosperous investigation of low–cost sodium ion batteries. The inferior long–term cycling stability of cathode materials is a significant roadblock toward the wide commercialization of sodium ion batteries. This study enlightens a path toward empowering stable sodium ion batteries through incisive diagnostics of the multiscale surface chemical processes in layered oxide materials (e.g., O3–NaNi 1/3 Fe 1/3 Mn 1/3 O 2 ). The major challenges are unraveled in a promising sodium layered cathode material using a range of complementary advanced spectroscopic and imaging diagnostic techniques. It is discovered that the cathode–electrolyte interfacial reaction triggers transition metal reduction, heterogeneous surface reconstruction, metal dissolution, and formation of intragranular nanocracks. These surface chemistry driven processes are partly responsible for significant performance decay. This diagnostic study also rationalizes the elemental substitution and surface passivation methods that are widely applied in the field. The prepassivated and Ti–substituted cathode materials allow for significantly improved cycling stability by inhibiting the metal dissolution. Furthermore, incisively diagnosing the interfacial chemistry not only creates scientific insights into understanding sodium cathode chemistry, but also represents an advance toward establishing universal interfacial design principles for all alkali metal ion cathode materials.

25 ENERGY STORAGE↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propulsion Controls and Diagnostics Research in Support of NASA Aeronautics and Exploration Mission Programs

The Controls and Dynamics Branch (CDB) at National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research and Exploration Systems Missions. This paper provides a brief overview of the various CDB tasks in support of the NASA programs. The programmatic structure of the CDB activities is described along with a brief overview of each of the CDB tasks including research objectives, technical challenges, and recent accomplishments. These tasks include active control of propulsion system components, intelligent propulsion diagnostics and control for reliable fault identification and accommodation, distributed engine control, and investigations into unsteady propulsion systems.

Garg, Sanjay↗

Enabling integrated AI control on DIII-D: a control system design with state-of-the-art experiments

We present the design and application of a general algorithm for Prediction And Control using MAchiNe learning (PACMAN) in DIII-D. Machine learning (ML)-based predictors and controllers have shown great promise in achieving regimes in which traditional controllers fail, such as tearing mode (TM) free scenarios, ELM-free scenarios and stable advanced tokamak conditions. The architecture presented here was deployed on DIII-D to facilitate the end-to-end implementation of advanced control experiments, from diagnostic processing to final actuation commands. This paper describes the detailed design of the algorithm and explains the motivation behind each design point. We also describe several successful ML control experiments in DIII-D using this algorithm, including a reinforcement learning controller targeting advanced non-inductive plasmas, a wide-pedestal quiescent H-mode ELM predictor, an Alfvén Eigenmode controller, a Model Predictive Control plasma profile controller and a state-machine TM predictor-controller. There is also discussion on guiding principles for real-time ML controller design and implementation.

machine learning↗

Spontaneous Raman Scattering Diagnostics: Applications in Practical Combustion Systems

In this chapter, the recent advancements and practical aspects of laser SRS diagnostics have been reviewed wi til regards to applications in practical combustion systems. Clearly, SRS represents a theoretically and experimentally mature diagnostic technology that has become an essential tool for multiscalar measurements in turbulent combustion at elevated pressures. Today, time-, space-, spectrally, and even polarization-resolved S RS diagnostics is at hand, with aid from recent innovations in theoretical and technological developments on electro-optical or electromechanical devices. Whilst a linear increase in SRS signals can be expected in high-pressure systems (this is perhaps one of the most important advantages for using SRS in high-pressure systems), there are practical (often severe) restrictions associated with pressurized vessels, due mainly to the limited degree of optical access. This narrows ti,e available choice of diagnostics that can be employed at any given time. Point-wise SRS diagnostics provides the highest accuracy on the chemical species and temperature measurements, and will continue to remain a vital approach for the study in such harsh environments. The practical design considerations and hands-on set-up guide for SRS diagnostics provided in this chapter are rarely presented elsewhere. Although the second-harmonic Nd:YAG pulsed laser (532 nm), combined with pulse-stretching optics or the recently introduced White Cell-based laser, seems to be the most favored excitation source of choice by the research community, UV excitation will undoubtedly continue to be used on many occasions, and especially in sooting flames. Detection methods may be divided into ICCD-based nanosecond-gate detection or a rotary-chopper electromechanical shutter-based CCD array detection, and the levels of background flame emission in individual cases would determine this critical design choice. Here, a process of Raman signal calibration based on ti,e crosstalk matrix formalism was explained step-by-step. As tI,is process may be very time-consuming and expensive, a well-planned experimental approach (01' building a transferable calibration database or library (at least with in a user's own facility over a series of different testing and runs) is vitally important. Hands on advice on the design and construction of flow control systems for high pressure burner facilities were also presented.

Kojima, Jun↗

Challenges in Accelerator Beam Instrumentation

The challenges in beam instrumentation and diagnostics for present and future particle accelerator projects are presented. A few examples for advanced hadron and lepton beam diagnostics are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fuel Injector Patternation Evaluation in Advanced Liquid-Fueled, High Pressure, Gas Turbine Combustors, Using Nonintrusive Optical Diagnostic Techniques

Planar laser-induced fluorescence (PLIF) imaging and planar Mie scattering are used to examine the fuel distribution pattern (patternation) for advanced fuel injector concepts in kerosene burning, high pressure gas turbine combustors. Three diverse fuel injector concepts for aerospace applications were investigated under a broad range of operating conditions. Fuel PLIF patternation results are contrasted with those obtained by planar Mie scattering. Further comparison is also made for one injector with data obtained through phase Doppler measurements. Differences in spray patterns for diverse conditions and fuel injector configurations are readily discernible. An examination of the data has shown that a direct determination of the fuel spray angle at realistic conditions is also possible. The results obtained in this study demonstrate the applicability and usefulness of these nonintrusive optical techniques for investigating fuel spray patternation under actual combustor conditions.

Locke, R. J.↗

Microbiome-wide association studies link dynamic microbial consortia to disease

Rapid advances in DNA sequencing, metabolomics, proteomics and computational tools are dramatically increasing access to the microbiome and identification of its links with disease. In particular, time-series studies and multiple molecular perspectives are facilitating microbiome-wide association studies, which are analogous to genome-wide association studies. Early findings point to actionable outcomes of microbiome-wide association studies, although their clinical application has yet to be approved. An appreciation of the complexity of interactions among the microbiome and the host's diet, chemistry and health, as well as determining the frequency of observations that are needed to capture and integrate this dynamic interface, is paramount for developing precision diagnostics and therapies that are based on the microbiome.

Gilbert, Jack A.↗