Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Facilities for high-pressure research with the diamond anvil cell at GSECARS

An overview of facilities for high-pressure research with the diamond anvil cell (DAC) at the GeoSoilEnviroCARS (GSECARS) sector at the Advanced Photon Source (Argonne, Illinois) is presented. There are three operational experimental stations (13-ID-C, 13-ID-D and 13-BM-D) where DAC instrumentation is installed for various types of experiments at high pressure and extreme temperature conditions. A fourth station (13-BM-C) is under construction and will be operational in 2006. While most X-ray diffraction experiments have been undertaken with powder samples so far, there is a growing demand for single-crystal diffraction (SCD) at high pressure. As one of the principal components at GSECARS, SCD is currently under rapid development. Other relevant techniques have also been developed for obtaining complementary information from powder or single-crystal samples at high pressure. For example, an on-line Brillouin system is installed and operational at 13-BM-D for acoustic velocity and single-crystal elasticity determinations. In addition, various X-ray spectroscopy techniques (e.g. X-ray emission and X-ray Raman) are employed for measuring electronic and magnetic properties. Future developments are discussed with the DAC program at GSECARS.

43 PARTICLE ACCELERATORS↗

Transverse impedance measurement using response matrix fit method at APS.

The Advanced Photon Source (APS) is a third-generation synchrotron light source based on a 7-GeV electron storage ring. In third-generation light sources the synchrotron radiation is mainly produced in undulators. In order to achieve high photon flux and tunability, the magnet gap in undulators has to be as small as possible. Therefore, the undulators are installed on dedicated small-gap insertion device (ID) vacuum chambers. APS has thirty-five 5-m-long straight sections available for undulators. At the time of the measurements, there were 31 straight sections occupied with various insertion devices, and 4 straight sections were still empty. Most of the ID vacuum chambers have a 8-mm in-vacuum gap, and two chambers have a 5-mm gap. These narrow-gap vacuum chambers are believed to be the main source of the transverse impedance of the machine. One can measure the combined impedance by measuring the transverse tune slope with single-bunch current. Comparing this slope before and after installation of the narrow-gap vacuum chamber, one can deduce the impedance of the chamber. It is difficult to accurately measure the change in the tune slope after one or a few new ID chambers are installed. If several identical ID vacuum chambers are installed over a period of time, then one can estimate the contribution of one ID chamber. Over the last few years there have been a number of attempts to measure the impedance of separate components of accelerators. Phase-advance measurements from beam position monitor (BPM) turn-by-turn histories were used at LEP to measure the impedance distribution around the ring. Researches at LEP were able to fit average impedance in the long sections of the LEP arc and determine the impedance of the rf sections. The method was tried at APS; however, the accuracy of the measurements was not enough to determine the small impedance of a single ID vacuum chamber. There is also a different approach that uses local orbit bumps to probe different parts of an accelerator. The orbit bump method was done at BINP, APS, and ESRF. All these methods have one common feature: they employ the fact that the beam sees the impedance as an additional defocusing quadrupole whose strength depends on the beam current. At APS we use an orbit response matrix fit to determine the distribution of focusing errors around the machine, and then use these errors to calculate beta functions. Since the beam sees the impedance as a quadrupole whose strength depends on the beam current, the measurement of the beta functions with different currents could be used to determine the impedance distribution around the machine. This approach was first used at APS and reported in.

43 PARTICLE ACCELERATORS↗

X-ray Parametric Down Conversion at the APS Synchrotron

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. We use an incoming pump beam at 22 keV to observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Technical Report-Grant # DE-FG02-97ER45628 ?Structural Diorder in Materials?

Since the grant was renewed in 2000 and 2003 final technical reports of the grant have been previously submitted for those years. For that reason this final technical report covers the last four years of the grant. We had an exceptionally successful and productive last four years under the support of the grant. Our progress takes three different aspects, described in more detail below: 1.1 instrumentation, infrastructure, and other research support at Sector 20 of the Advanced Photon Source (APS); 1.2 research on which Profs. Stern or Seidler were PI?s; and 1.3 research on which Profs. Stern or Seidler were co-PI?s or where Drs. Dale Brewe or Julie Cross were authors or co-authors. Drs. Brewe and Cross are the two research scientists (permanently stationed at sector 20) who are supported by the grant. They provide support to the scientific goals of the grant and more broadly provide research support for many general users at Sector 20. Finally, in section 1.4 we provide a complete list of publications resulting from funding in the grant on which at least one of Stern, Seidler, Cross, or Brewe were co-authors. Given the inclusion of operations funding in the grant, this is of course a subset of the full scientific impact of the grant.

36 MATERIALS SCIENCE↗

High-pressure X-ray diffraction studies of potassium chlorate

Two static high-pressure X-ray diffraction (XRD) studies of potassium chlorate have been performed at pressures of up to {approx}14.3 GPa in a diamond anvil cell at ambient temperature using the 16 ID-B undulator beamline at the Advanced Photon Source for the X-ray source. The first experiment was conducted to ascertain decomposition rates of potassium chlorate as a function of pressure. Below 2 GPa, the sample was observed to decompose rapidly in the presence of the X-ray beam and release oxygen. Above 2 GPa (near the phase I phase II transition), the decomposition rate dramatically slowed so that good quality XRD patterns could be acquired. This suggests a phase-dependent decomposition rate. In the second study, X-ray diffraction spectra were collected at pressures from 2 to 14.3 GPa by aligning virgin portions of the sample into the focused X-ray beam at each pressure. The results suggest the co-existence of mixed monoclinic (I) and rhombohedral (II) phases of potassium chlorate near 2 GPa. At pressures beyond 4 GPa, the XRD patterns show a very good fit to KClO{sub 3} in the rhombohedral phase with space group R3m, in agreement with earlier studies. No further phase transitions were observed with pressure. Decompression of the sample to ambient pressure indicated mixed phases I and II coupled with a small amount of synchrotron X-ray-induced decomposition product. The equation of state within this pressure regime has been determined.

43 PARTICLE ACCELERATORS↗

The Intensity Of The 2.7nm Reflection As A Constraint For Models Of Myosin Docking To Actin

Previous workers have proposed high resolution models for the docking of the myosin heads on actin on the basis of combined crystallographic and electron microscopy data (Mendelson and Morris, 1997 PNAS 94:8533; Holmes et al. 2003 Nature 425:423). We have used data from small angle X-ray fiber diffraction from living muscle to check the predictions of these models. Whole sartorius muscles from Rana pipiens were mounted in a chamber containing Ringer's solution at 10 C and at rest length at the BioCAT beamline (18 ID, Advanced Photon Source, Argonne, IL-U.S.A.). The muscles were activated by electrical stimulation and the force was recorded with a muscle lever system type 300B (Aurora Scientific). X-ray patterns were collected with 1s total exposures at rest and during isometric contraction out to 0.5 nm{sup -1} in reciprocal space, as the higher angle reflections are expected to be more sensitive to the arrangement of myosin heads on actin. We observed that during isometric contraction the meridional reflection originating from the 2.73nm repeat of the actin monomers along the actin filament increases its intensity by a factor 2.1 {+-} 0.2 relative to rest. Among the models tested, Holmes et al. fits the data when the actin filament is decorated with 30-40% the total available myosin heads, a fraction similar to that estimated with fast single fiber mechanics by Piazzesi et al. (2007, Cell 131:784). However, when the mismatch between the periodicities of actin and myosin filaments is taken into account, none of the models can reproduce the fiber diffraction data. We suggest that the fiber diffraction data should be used as a further constraint on new high resolution models for the docking of the myosin heads on actin.

43 PARTICLE ACCELERATORS↗

2D and 3D X-Ray Structural Microscopy Using Submicron-Resolution Laue Microdiffraction

We have developed a scanning, polychromatic x-ray microscopy technique with submicron spatial resolution at the Advanced Photon Source. In this technique, white undulator radiation is focused to submicron diameter using elliptical mirrors. Laue diffraction patterns scattered from the sample are collected with an area detector and then analyzed to obtain the local crystal structure, lattice orientation, and strain tensor. These new microdiffraction capabilities have enabled both 2D and 3D structural studies of materials on mesoscopic length-scales of tenths-to-hundreds of microns. For thin samples such as deposited films, 2D structural maps are obtained by step-scanning the area of interest. For example, 2D x-ray microscopy has been applied in studies of the epitaxial growth of oxide films. For bulk samples, a 3D differential-aperture x-ray microscopy technique has been developed that yields the full diffraction information from each submicron volume element. The capabilities of 3D x-ray microscopy are demonstrated here with measurements of grain orientations and grain boundary motion in polycrystalline aluminum during 3D thermal grain growth. X-ray microscopy provides the needed, direct link between the experimentally measured 3D microstructural evolution and the results of theory and modeling of materials processes on mesoscopic length scales.

36 MATERIALS SCIENCE↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

In situ TEM and synchrotron characterization of U–10Mo thin specimen annealed at the fast reactor temperature regime

U–Mo metallic alloys have been extensively used for the Reduced Enrichment for Research and Test Reactors (RERTR) program, which is now known as the Office of Material Management and Minimization under the Conversion Program. This fuel form has also recently been proposed as fast reactor metallic fuels in the recent DOE Ultra-high Burnup Fast Reactor project. In order to better understand the behavior of U–10Mo fuels within the fast reactor temperature regime, a series of annealing and characterization experiments have been performed. Annealing experiments were performed in situ at the Intermediate Voltage Electron Microscope (IVEM-Tandem) facility at Argonne National Laboratory (ANL). An electro-polished U–10Mo alloy fuel specimen was annealed in situ up to 700 °C. At an elevated temperature of about 540 °C, the U–10Mo specimen underwent a relatively slow microstructure transition. Nano-sized grains were observed to emerge near the surface. At the end temperature of 700 °C, the near-surface microstructure had evolved to a nano-crystalline state. In order to clarify the nature of the observed microstructure, Laue diffraction and powder diffraction experiments were carried out at beam line 34-ID of the Advanced Photon Source (APS) at ANL. Phases present in the as-annealed specimen were identified with both Laue diffraction and powder diffraction techniques. The U–10Mo was found to recrystallize due to thermally-induced recrystallization driven by a high density of pre-existing dislocations. A separate in situ annealing experiment was carried out with a Focused Ion Beam processed (FIB) specimen. A similar microstructure transition occurred at a lower temperature of about 460 °C with a much faster transition rate compared to the electro-polished specimen. - Highlights: • TEM annealing experiments were performed in situ at the IVEM facility up to fast reactor temperature. • At 540 °C, the U-10Mo specimen underwent a slow microstructure transition where nano-sized grains were observed to emerge. • UO{sub 2} phase exists at the thin area of the as-annealed specimen whereas U-10Mo γ phase dominated at the thicker part. • Bcc γ U-10Mo recrystallized to become nano-meter sized crystallites near the specimen surface. • A separateannealing experiment was conducted with a FIB processed specimen where similar transition occurred at a lower temperature of 460 °C with a faster rate.

36 MATERIALS SCIENCE↗

Au-Ag Alloy Static High Pressure EOS measurements: FY09 summary of results

Static high-pressure measurements of the equation of state of a Gold-Silver alloy (23.5 wt-% Ag) at room temperature were performed up to a pressure of approximately 100 GPA (1 megabar). Measurements were made using an energy-dispersive x-ray diffraction method. The data was analyzed, yielding crystal structure lattice constants and volume/density as a function of pressure. The results are extremely precise yielding accuracy of better than 1%. The experiments were carried out at the HPCAT 16BM-D beamline at the Advanced Photon Source. Two experiments on separate samples were carried out using conventional membrane diamond anvil cells. To achieve hydrostatic conditions, we loaded a 50-100 micron piece of the Au-Ag alloy into the cell and surrounded it with neon and mineral oil pressure media in the respective experiments. The differing pressure media demonstrated no measurable difference on the resultant crystal structures, lattice constants or pressure-volume curves. Results of our work are shown in the figures below. Up to the maximum pressure of 100 GPa the sample remained in the face-centered cubic structure, e.g., we observed no change in crystal structure. EOS curves of silver and gold, taken from the literature, are shown for comparison. We fit our data to a Vinet EOS functional form, and the parameters for this EOS were found to be, Reference (ambient pressure) volume, V{sub 0} = 16.965435 {angstrom}{sup 3}; Reference (ambient pressure) density, {rho}{sub 0} = 16.14584 g/cm{sup 3}; Bulk Modulus, K{sub 0} = 144 GPa; and Bulk Mod Derivative, K{prime}{sub 0} = 5.66. As one might expect the Au-Ag alloy lies between the gold and silver EOS curves, and tracks more closely to the gold EOS. These data are useful in validating and developing predictive EOS models of the pressure-dependent behavior of Au-Ag alloys.

36 MATERIALS SCIENCE↗

Considerations on ODR beam-size monitoring for gamma = 1000 beams

We discuss the feasibility of monitoring the beam size of {gamma} = 1000 beams with 3000 times more charge in a video frame time and with a more sensitive 12- to 16-bit camera than were used in the previous electron beam studies at 7 GeV at the Advanced Photon Source. Such a beam would be generated at Fermilab in a new facility in the coming years. Numerical integrations of our base model show beam size sensitivity for {+-} 20% level changes at 200- and 400-{micro}m base beam sizes. We also evaluated impact parameters of 5 {sigma}{sub y} and 12 {sigma}{sub y} for both 800-nm and 10-{micro}m observation wavelengths. The latter examples are related to a proposal to apply the technique to an {approx}0.98 TeV proton beam, and this study shows there are trades on photon intensity and beam size sensitivity to be considered at such gammas. In addition, we report on first results at {gamma} = 1800 on a superconducting rf linac.

43 PARTICLE ACCELERATORS↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Application of pixel array detectors at x-ray synchrotrons.

Pixel array detectors have only recently been seriously used at x-ray synchrotrons. We describe the application of a digital pixel array detector (Pilatus100k) to a variety of synchrotron experiments at the Advanced Photon Source at Argonne National Laboratory. The Pilatus100k was developed at the Paul Scherrer Institut (PSI). It has been commercialized by a PSI spinoff (Dectrics Ltd.) This is the first commercially available pixel array detector for x-ray synchrotron applications. The APS synchrotron provides tunable x-ray pulses with duration of {approx}80 ps and a repetition period of 153 ns (24-bunch mode). The Pilatus100k is a direct detection x-ray detector where each 172 micron pixel counts individual x-ray pulses above a lower threshold. It consists of {approx}100k pixels each of which is capable of single-photon counting (>3 keV) at count rates up to {approx}1 MHz. In addition, the Pilatus100k is an electronically gateable detector. We present data showing that the Pilatus100k is capable of isolating a single x-ray bunch at the APS in 24 bunch mode. We will also present a variety of different experiments exploiting the unique capabilities of the Pilatus100k.

43 PARTICLE ACCELERATORS↗

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

43 PARTICLE ACCELERATORS↗

Development of short-period Nb{sub 3}Sn superconducting undulators for the APS.

Superconducting undulators (SCUs) with a period of 14.5 mm are under development for the Advanced Photon Source (APS) using Nb{sub 3}Sn superconductors. The initial goal is to install a SCU with a 19- to 29-keV tuning range for the first harmonic photon energy. The design of the SCU assembly includes the interface with the beam chamber as an integral part of the assembly. A four-period Nb{sub 3}Sn half SCU was fabricated and tested. After a number of quenches, the SCU was charged to an engineering current density of 1.92 kA/mm{sup 2} in the coil pack. This corresponds to a peak field of 1.08 T on the beam axis with a pole gap of 8.5 mm. The achieved current density was approximately 90% of the engineering critical current density for the design calculations. With an operating current density of 1.6 kA/mm{sup 2}, the SCU will operate at a peak field of 0.95 T with some degree of stability.

43 PARTICLE ACCELERATORS↗

In-Situ phase and texture characterization of solution deposited PZT thin films during crystallization.

Ferroelectric lead zirconate titanate (PZT) thin films are used for integrated capacitors, ferroelectric memory, and piezoelectric actuators. Solution deposition is routinely used to fabricate these thin films. During the solution deposition process, the precursor solutions are spin coated onto the substrate and then pyrolyzed to form an amorphous film. The amorphous film is then heated at a higher temperature (650-700 C) to crystallize the film into the desired perovskite phase. Phase purity is critical in achieving high ferroelectric properties. Moreover, due to the anisotropy in the structure and properties of PZT, it is desirable to control the texture obtained in these thin films. The heating rate during crystallization process is known to affect the sequence of phase evolution and texture obtained in these thin films. However, to date, a comprehensive understanding of how phase and texture evolution takes place is still lacking. To understand the effects of heating rate on phase and texture evolution, in-situ diffraction experiments during the crystallization of solution deposited PZT thin films were carried out at beamline 6-ID-B, Advanced Photon Source (APS). The high X-ray flux coupled with the sophisticated detectors available at the APS synchrotron source allow for in-situ characterization of phase and texture evolution at the high ramp rates that are commonly used during processing of PZT thin films. A PZT solution of nominal composition 52/48 (Zr/Ti) was spin coated onto a platinum-coated Si substrate (Pt//TiO{sub x}//SiO{sub 2}//Si). The films were crystallized using an infrared lamp, similar to a rapid thermal annealing furnace. The ramp rate was adjusted by controlling the voltage applied to the infrared lamp and increasing the voltage by a constant step with every acquisition. Four different ramp rates, ranging from {approx}1000 C/s to {approx}1 C/s, were investigated. The sample was aligned in grazing incidence to maximize the signal from the thin films. Successive diffraction patterns were acquired with a 1s acquisition time using a MAR SX-165 CCD detector during crystallization. The sample to detector distance and the tilt rotations of the detector were determined in Fit2D{copyright} by using Al{sub 2}O{sub 3} as the calibrant. These corrections were applied to the patterns when binning the data into radial (2{theta}) and azimuthal bins. The texture observed in the thin film was qualitatively analyzed by fitting the intensity peaks along the azimuthal direction with a gaussian profile function to obtain the integrated intensity of the peaks. Data analysis and peak fitting was done using the curve fitting toolbox in MATLAB{copyright}. A fluorite-type phase was observed to form before the perovskite phase for all ramp rates. PtxPb is a transient intermetallic formed due to the interaction of the thin film and the bottom electrode during crystallization. Ramp rate was observed to significantly affect the amount of PtxPb observed in the thin films during crystallization. Ramp rate was also observed to affect the final texture obtained in the thin films. These results will be discussed in the poster in view of the current understanding of these materials.

43 PARTICLE ACCELERATORS↗

A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure

A modified Drickamer anvil apparatus has been developed to combine with monochromatic synchrotron radiation for high-pressure X-ray diffraction and radiography in the GSECARS bending-magnet station, 13-BM-D, at the Advanced Photon Source, Argonne, USA. Using this experimental set-up, deformation experiments can be carried out at pressures in excess of 30 GPa at high temperatures. Differential stresses and total axial strains of polycrystalline platinum and Mg{sub 2}SiO{sub 4} ringwoodite have been measured up to 32 GPa at room temperature using tungsten carbide anvils. The total axial strain of the platinum increases with pressure and reaches about 55% at the highest pressure. A test run using a composite sintered diamond anvil system was performed. The use of X-ray-tranparent anvils enables the entire Debye rings to be observed up to 10{sup o} 2{theta}. With high-energy photons (65-70 keV), this allows a coverage in Q (= 2{pi} sin{theta}/{lambda}) to about 3 {angstrom}{sup -1}, thus making it possible to evaluate hydrostatic pressure and differential stress in crystalline minerals using diffraction. This, coupled with the ability to determine axial strain, allows deformation studies to be performed to pressures above 30 GPa.

43 PARTICLE ACCELERATORS↗