Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Advanced nickel-hydrogen spacecraft battery development

Eagle-Picher currently has several advanced nickel-hydrogen (NiH2) cell component and battery designs under development including common pressure vessel (CPV), single pressure vessel (SPV), and dependent pressure vessel (DPV) designs. A CPV NiH2 battery, utilizing low-cost 64 mm (2.5 in.) cell diameter technology, has been designed and built for multiple smallsat programs, including the TUBSAT B spacecraft which is currently scheduled (24 Nov. 93) for launch aboard a Russian Proton rocket. An advanced 90 mm (3.5 in.) NiH2 cell design is currently being manufactured for the Space Station Freedom program. Prototype 254 mm (10 in.) diameter SPV batteries are currently under construction and initial boilerplate testing has shown excellent results. NiH2 cycle life testing is being continued at Eagle-Picher and IPV cells have currently completed more than 89,000 accelerated LEO cycles at 15% DOD, 49,000 real-time LEO cycles at 30 percent DOD, 37,800 cycles under a real-time LEO profile, 30 eclipse seasons in accelerated GEO, and 6 eclipse seasons in real-time GEO testing at 75 percent DOD maximum. Nickel-metal hydride battery development is continuing for both aerospace and electric vehicle applications. Eagle-Picher has also developed an extensive range of battery evaluation, test, and analysis (BETA) measurement and control equipment and software, based on Hewlett-Packard computerized data acquisition/control hardware.

Coates, Dwaine K.↗

Flight critical system design guidelines and validation methods

Efforts being expended at NASA-Langley to define a validation methodology, techniques for comparing advanced systems concepts, and design guidelines for characterizing fault tolerant digital avionics are described with an emphasis on the capabilities of AIRLAB, an environmentally controlled laboratory. AIRLAB has VAX 11/750 and 11/780 computers with an aggregate of 22 Mb memory and over 650 Mb storage, interconnected at 256 kbaud. An additional computer is programmed to emulate digital devices. Ongoing work is easily accessed at user stations by either chronological or key word indexing. The CARE III program aids in analyzing the capabilities of test systems to recover from faults. An additional code, the semi-Markov unreliability program (SURE) generates upper and lower reliability bounds. The AIRLAB facility is mainly dedicated to research on designs of digital flight-critical systems which must have acceptable reliability before incorporation into aircraft control systems. The digital systems would be too costly to submit to a full battery of flight tests and must be initially examined with the AIRLAB simulation capabilities.

Holt, H. M.↗

Hypovolemia in syncope and orthostatic intolerance role of the renin-angiotensin system

PURPOSE: Orthostatic intolerance is the cause of significant disability in otherwise normal patients. Orthostatic tachycardia is usually the dominant hemodynamic abnormality, but symptoms may include dizziness, visual changes, discomfort in the head or neck, poor concentration, fatigue, palpitations, tremulousness, anxiety and, in some cases, syncope. It is the most common disorder of blood pressure regulation after essential hypertension. There is a predilection for younger rather than older adults and for women more than men. Its cause is unknown; partial sympathetic denervation or hypovolemia has been proposed. METHODS AND MATERIALS: We tested the hypothesis that reduced plasma renin activity, perhaps from defects in sympathetic innervation of the kidney, could underlie a hypovolemia, giving rise to these clinical symptoms. Sixteen patients (14 female, 2 male) ranging in age from 16 to 44 years were studied. Patients were enrolled in the study if they had orthostatic intolerance, together with a raised upright plasma norepinephrine (> or = 600 pg/mL). Patients underwent a battery of autonomic tests and biochemical determinations. RESULTS: There was a strong positive correlation between the blood volume and plasma renin activity (r = 0.84, P = 0.001). The tachycardic response to upright posture correlated with the severity of the hypovolemia. There was also a correlation between the plasma renin activity measured in these patients and their concomitant plasma aldosterone level. CONCLUSIONS: Hypovolemia occurs commonly in orthostatic intolerance. It is accompanied by an inappropriately low level of plasma renin activity. The degree of abnormality of blood volume correlates closely with the degree of abnormality in plasma renin activity. Taken together, these observations suggest that reduced plasma renin activity may be an important pathophysiologic component of the syndrome of orthostatic intolerance.

Non-NASA Center↗

Swing Bed Scrubber Design and Test Integration Results for Carbon Dioxide Removal in the Ventilation Test Loop 2.0

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS provides the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The PLSS ventilation subsystem is responsible for providing adequate carbon dioxide (CO2) and water vapor removal. To experimentally validate the performance of CO2 removal and advanced CO2 sensing systems, NASA Johnson Space Center developed the Ventilation Test Loop 2.0 (VTL2) and tested the Oceaneering Swing Bed Scrubber (SBS) that was fabricated and delivered under the Constellation Space Suit System Contract in 2015. The SBS was designed to continuously remove CO2 and water vapor from a space suit ventilation loop with a pair of thermally integrated amine beds that alternately adsorb and desorb water vapor and CO2. The SBS hardware was recently resurrected and reassembled to support a full battery of performance testing in the VTL2. This paper describes the design and development of the SBS and the VTL2 along with the performance test results of the SBS.

Ventilation Test Loop↗

The 1973 GSFC battery workshop, second day

Technological progress in the development, testing, and manufacturing of nickel-cadmium battery cells as well as hydrogen cells is presented. The following major topics were discussed: (1) carbonate analysis; (2) nickel-cadmium memory effect; (3) use of batteries in an automatic acquisition and control system; (4) accelerated testing; (5) formulation of a mathematical odel for a nickel-cadmium cell; (6) development of a light weight nickel-cadmium battery capable of delivering 20 watt hours per pound; (7) magnetic testing of nickel-cadmium cells; (8) design and performance characteristics of nickel-hydrogen and silver-hydrogen cells; and (9) development of a semiprismatic cell design. For Vol. 1, see N75-15152.

Source record↗

Parametric and cycle tests of a 40-AH bipolar nickel-hydrogen battery

The performance of a 12 V, 40 ampere-hour bipolar battery during various charge current, discharge current, temperature, and pressure operating conditions is investigated. The cell voltages, temperatures, ampere-hours, and watt-hours derived from the charge/discharge cycle tests are studied. Consideration is given to battery voltage and discharge capacity as a function of discharge current, the correlation between energy delivered on a discharge and battery temperature, battery voltage response to pulse discharges, and the voltage-temperature relationship. The data reveal that the bipolar Ni-H battery is applicable to high power systems.

Cataldo, R. L.↗

NiCd battery reliability for shuttle serviced spacecraft

Data from life-cycle testing of 22-cell NiCd batteries designed for shuttle-service spacecrafts are analyzed, first by averaging battery cycle lives as a function of temperature and depth of discharge, and then by calculating single cell failure and survival probabilities as a function of temperature, depth of discharge, and number of operating cycles. The single cell data are used to calculate battery survival probabilities. A mathematical failure model which is a function of the quantity of charge through the battery and the temperature is characterized, suggesting a predictive capability for accurate estimation of energy storage subsystem life and performance of accelerated tests. The failure mechanism described is apparently independent of most charge-discharge parameters and common to most cell sizes.

Eliason, J.↗

The 1975 GSFC Battery Workshop

The proceedings of the 1975 Goddard Space Flight Center Battery Workshop are presented. The major topics of discussion were nickel cadmium batteries and, to a lesser extent, nickel hydrogen batteries. Battery design, manufacturing techniques, testing programs, and electrochemical characteristics were considered. The utilization of these batteries for spacecraft power supplies was given particular attention.

Source record↗

Viking lander spacecraft battery

The Viking Lander was the first spacecraft to fly a sterilized nickel-cadmium battery on a mission to explore the surface of a planet. The significant results of the battery development program from its inception through the design, manufacture, and test of the flight batteries which were flown on the two Lander spacecraft are documented. The flight performance during the early phase of the mission is also presented.

Newell, D. R.↗

SMS/GOES cell and battery data analysis report

The nickel-cadmium battery design developed for the Synchronous Meteorological Satellite (SMS) and Geostationary Operational Environmental Satellite (GOES) provided background and guidelines for future development, manufacture, and application of spacecraft batteries. SMS/GOES battery design, development, qualification testing, acceptance testing, and life testing/mission performance characteristics were evaluated for correlation with battery cell manufacturing process variables.

Armantrout, J. D.↗

Development of a Woven-Grid Quasi-Bipolar Battery

This report describes an analytical and experimental investigation of AeroVironment's Quasi-Bipolar battery concept. The modelling/battery design part of the study demonstrates that there is a trade-off between thermal and specified electrical performance. Even so, quasi-bipolar batteries can be designed, with ten times better thermal uniformity, that meet or exceed current state-of-the-art hybrid-electric vehicle battery pack performance, even using the same active materials. The thermal uniformity, power, and energy for these quasi-bipolar battery packs is projected to be very good. The experimental part of the investigation demonstrates the concept of the quasi-bipolar plate applied to a lead foil current collector wrapping around two sides of an inexpensive plastic film core. Approximately 50 quasi-biplate samples were fabricated using a hot laminating press. Hot lamination with "texture" between the plastic and lead shows some promise as a low cost method for fabricating the plates. Five of these plates were assembled into two cells plus one two-cell battery. Data from these test cells were compared with existing data for similar true bipolar batteries. The positive side of the plates exhibited corrosion where not protected by the active material.

Tokumaru, P.↗

Additively Manufactured Ink-based Cell Batteries for Flexible Conformational Applications

With the rise of additively manufactured electronics, the importance of thin, flexible printed batteries has increased for shape-conformal electronics. Traditionally, battery cells such as industry-standard lithium-ion batteries, have been rigid and therefore unable to conform to time-variant surfaces such as smart cards/RFID devices, disposable battery-powered skin patches, foldable electronic devices, and IoT nodes. Aligned with the effort to advance technologies on printed electronics for habitat systems and advanced manufacturing, this proof-of-concept will focus on printing a 50 mAh Zn-Ag battery implementing a DIW Technique. After prototype manufacturing, electrical and environmental testing on the flexible battery cell will be conducted to the evaluate energy and power density over 50 charge cycles under standard atmosphere conditions. The project aims to provide PCB designers, fabricators, and assemblers an integrated battery package to eliminate external batteries, external wiring and connectors, and conformational complexity. Potential end uses of the printed battery process will be within Martian and lunar habitat systems, Gateway, and surface vehicles, or aerial robots where space and geometry is a restriction.

Printed Electronics↗

Hubble Space Telescope Battery Capacity Update

Orbital battery performance for the Hubble Space Telescope is discussed and battery life is predicted which supports decision to replace orbital batteries by 2009-2010 timeframe. Ground characterization testing of cells from the replacement battery build is discussed, with comparison of data from battery capacity characterization with cell studies of Cycle Life and 60% Stress Test at the Naval Weapons Surface Center (NWSC)-Crane, and cell Cycle Life testing at the Marshal Space Flight Center (MSFC). The contents of this presentation includes an update to the performance of the on-orbit batteries, as well as a discussion of the HST Service Mission 4 (SM4) batteries manufactured in 1996 and activated in 2000, and a second set of SM4 backup replacement batteries which began manufacture Jan 11, 2007, with delivery scheduled for July 2008.

Hollandsworth, Roger↗

Microbatteries for Combinatorial Studies of Conventional Lithium-Ion Batteries

Integrated arrays of microscopic solid-state batteries have been demonstrated in a continuing effort to develop microscopic sources of power and of voltage reference circuits to be incorporated into low-power integrated circuits. Perhaps even more importantly, arrays of microscopic batteries can be fabricated and tested in combinatorial experiments directed toward optimization and discovery of battery materials. The value of the combinatorial approach to optimization and discovery has been proven in the optoelectronic, pharmaceutical, and bioengineering industries. Depending on the specific application, the combinatorial approach can involve the investigation of hundreds or even thousands of different combinations; hence, it is time-consuming and expensive to attempt to implement the combinatorial approach by building and testing full-size, discrete cells and batteries. The conception of microbattery arrays makes it practical to bring the advantages of the combinatorial approach to the development of batteries.

West, William↗

Human-rated Safety Certification of a High Voltage Robonaut Lithium-ion Battery

NASA's rigorous certification process is being followed for the R2 high voltage battery program for use of R2 on International Space Station (ISS). Rigorous development testing at appropriate levels to credible off-nominal conditions and review of test data led to design improvements for safety at the virtual cell, cartridge and battery levels. Tests were carried out at all levels to confirm that both hardware and software controls work. Stringent flight acceptance testing of the flight battery will be completed before launch for mission use on ISS.

Jeevarajan, Judith↗