Search NASA⌕ Search

SEARCH · Search NASA

Results for “Boosting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Long carbon fibers boost performance of dry processed Li-ion battery electrodes

Dry processing (DP) is an advanced manufacturing technique for lithium-ion battery (LIB) electrodes. Unlike conventional wet-process-based manufacturing that involves dissolving polyvinylidene fluoride (PVDF) binder in n-methyl-2-pyrrolidone (NMP) solvent for slurry-casting, DP involves fibrillation of polymer binders. This method offers environmental and cost benefits by eliminating the need for expensive and environmentally hazardous organic solvents. However, DP-produced electrode films often lack mechanical stability due to the absence of a current collector substrate during electrode material layer fabrication. This reduced mechanical instability results in difficulty during fabricating of thin electrodes (≈5 mAh/cm 2 ). To address this issue, long (>8 mm) carbon fiber (CF) has been incorporated to reinforce the mechanical strength of the electrode films. In conclusion, the study demonstrates that the inclusion of long carbon fiber boosts the mechanical, electrical, thermal, and electrochemical performance of DP electrodes.

25 ENERGY STORAGE↗

Nanoparticles-constructed spinel ZnFe2O4 anode material with superior lithium storage performance boosted by pseudocapacitance

Highlights: • Nanoparticles-constructed ZnFe{sub 2}O{sub 4} was fabricated by co-precipitation method. • The ZnFe{sub 2}O{sub 4} sample shows excellent high rate capability and cycling stability. • The lithium storage mechanism was analyzed by CV and EIS measurements. • Pseudocapacitive effect has a significant contribution to the total stored charge. - Abstract: The practical application of ZnFe{sub 2}O{sub 4} in lithium ion batteries (LIBs) is severely hampered by its fast capacity fading and poor rate performance. To overcome these issues, herein, ZnFe{sub 2}O{sub 4} powders consist of aggregated nanoparticles (50∼100 nm) with porosity were prepared by a facile co-precipitation method and subsequent thermal decomposition. When used as anode material for LIBs, the ZnFe{sub 2}O{sub 4} sample delivers capacities of 920, 820, 650, 485, and 421 mA h g{sup −1} at current densities of 0.5, 1, 3, 7, and 10 A g{sup −1}, respectively. Moreover, the sample can maintain a capacity of 814 mA h g{sup −1} even after 300 cycles at the current density of 1 A g{sup −1}, implying an excellent rate capability and cycling stability. Cyclic voltammetry analysis reveals that both diffusion-controlled lithium storage and surface pseudocapacitive lithium storage contribute to the total stored charge of ZnFe{sub 2}O{sub 4}, which boosts the high rate capability and superior cycling stability of the ZnFe{sub 2}O{sub 4}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Approach to Computing Normal Tissue Complication Probability of an Intensity-Modulated Radiotherapy Treatment with Stereotactic Radiotherapy Boost of Nasopharyngeal Carcinoma: A Case Study

We attempted to develop a method to compute the normal tissue complication probability (NTCP) of various critical organs from combined intensity-modulated radiotherapy (IMRT) and stereotactic radiotherapy (SRT) boost treatment of nasopharyngeal carcinoma (NPC), with the aid of a nonlinear image registration method. The SRT's planning computed tomography (CT) of a NPC patient treated with IMRT was warped to the IMRT's planning CT using a nonlinear image registration. Because CT and dose were inherently in-register, the entire dose distribution could be deformed using the same deformation field derived from the two CT sets. Using the biologically effective dose concept and the linear-quadratic model, physical doses of IMRT and SRT were converted to a 2Gy-per-fraction equivalent dose to facilitate dose summation. The variation of organs' maximum doses of the combined treatments between traditional maximum dose sum and the proposed method was 1.5Gy {+-} 1.7Gy. After the correction of the effect of fractionation and dose heterogeneity within each organ, NTCP of each organ of interest was computed for the combined treatments. Based on the results of this case study, it is believed that dose registration could be a method for the NTCP computation of various critical organs when different fractionation schemes of radiation therapy treatment are instituted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decrease of the lumpectomy cavity volume after whole-breast irradiation affects small field boost planning

To determine whether small field boost (SFB) replanning is necessary when the lumpectomy cavity (LPC) decreases during whole-breast irradiation (WBI) and what parameters might predict a change in the SFB plan. Forty patients had computed tomography (CT) simulation (CT1) within 60 days of surgery and were resimulated (CT2) after 37.8-41.4 Gy for SFB planning. A 3-field photon plan and a single en face electron plan were created on both CTs and compared. In the 26 patients who had a {>=}5 cm{sup 3} and a {>=}25% decrease in lumpectomy cavity volume (LCV) between CT scans, the SFB plan using photons was different in terms of normal breast tissue volume irradiated (BTV) (p < 0.001), and field dimensions (p < 0.001). In 20/35 patients, the energy or field size changed for electron plans on CT2, but no tested characteristics predicted for a change. Less BTV was irradiated using electrons than photons in 29% (CT1) to 37% (CT2). SFB replanning needs to be individualized to each patient because of the variety of factors that can impact dosimetric planning. Replanning is recommended when using 3-field photons if the patient has experienced a {>=}5 cm{sup 3} and a {>=}25% decrease in LCV during WBI. Some patients may benefit from electron SFB replanning but no tested characteristics reliably predict those who may benefit the most. The amount of BTV irradiated is less with electrons than in photon plans and this has the potential to improve cosmesis, a clinically important outcome in breast-conserving therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer

This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV){sub 63} {sub Gy} as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV{sub 70} {sub Gy} and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV{sub 70} {sub Gy} coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: A simulation study based on intrafractional motion in the prone position

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3 mm received a dose of 94.5 Gy, whereas the remainder of the prostate + 7 mm received a dose of 75.6 Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4 mm (− 3.1 to 8.2 mm), − 2.2 mm (− 9.1 to 1.5 mm), and − 0.3 mm (− 5.0 to 1.8 mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V{sub 90%} of the IPL and V{sub 100%} of the prostate between the simulated plan and original plan were − 3.9% to − 0.3% and − 0.6% to 1.1% for respiration-induced motion and 3.1% to − 67.8% and 3.6% to − 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Boosting CO 2 reduction on Fe-N-C with sulfur incorporation: Synergistic electronic and structural engineering

Developing earth-abundant efficient catalysts for CO 2 reduction reaction (CO 2 RR) is of paramount importance for electrochemical conversion of CO 2 into value-added products. Despite numerous studies on iron and nitrogen codoped carbon (Fe-N-C) catalysts, grand challenges exist due to limited performance and understanding of catalytic mechanisms. This study reports a general strategy to boost electrocatalytic CO 2 RR activity of Fe-N-C with the incorporation of S atoms to engineer carbon support structure and electronic properties of active Fe-N sites simultaneously via a copolymer-assisted synthetic approach. The employment of N,S comonomers significantly increases the numbers of micropores and surface area, enabling dense atomic Fe-N and enhanced utilization efficiency. We report the first-principles calculations reveal that S modulation upraises the Fermi energy of Fe 3d and increases charge density on Fe atoms of Fe-N 4 , thereby enhancing intrinsic catalytic reactivity and selectivity for CO 2 reduction by strengthening the binding interaction between the Fe site and key COOH* intermediate. These integrated structural and electronic merits endow Fe-NS-C with outstanding activity (e.g., CO Faradaic efficiency of 98% at an overpotential of 490 mV) and stability (without deactivation in 30 h), ranking it one of the most active Fe-N-C reported to date. The finding offers an innovative design strategy to enable the design of advanced catalysts for CO 2 conversion.

25 ENERGY STORAGE↗

Polyimide as a durable cathode for all-solid-state Li(Na)–organic batteries with boosted cell-level energy density

The integration of organic electrode materials (OEMs) with solid-state electrolytes (SSEs) is expected to build an all-solid-state battery (ASSB) with long-term sustainability, high safety, and high energy density. Despite this great promise, the cell-level energy density is still far from practically applicable, which stems from the ultrathick SSE layer and thin cathode layer used in a pellet-type ASSB design. Here, a cost-effective polyimide (PI) material was first exploited as an organic cathode for sulfide-based ASSBs. A capacity of ~190 mAh g -1 was delivered with almost no capacity decay over 300 cycles. Moreover, for the first time, a dry-film approach was introduced to manufacture a sheet-type Li–organic ASSB with an ultrathin SSE layer and a high-areal-loading PI cathode. Notably, PI is a perfect candidate for dry-film technology due to its high thermal stability and extraordinary chemical inertness toward sulfide SSEs. Remarkably, the free-standing SSE membrane was merely 46 μm thick, and an ultralow areal resistance of 3.3 Ω cm 2 was achieved, more than tenfold lower than that of reported SSE pellets. One order of magnitude boost in the cell-level energy density was achieved. This work presents a significant leap in transferring organic ASSB technology from laboratory research to factory manufacturing.

25 ENERGY STORAGE↗

Search for Wγ resonances in proton-proton collisions at √s=13 TeV using hadronic decays of Lorentz-boosted W bosons

A search for W$\gamma$ resonances in the mass range between 0.7 and 6.0 TeV is presented. The W boson is reconstructed via its hadronic decays, with the final-state products forming a single large-radius jet, owing to a high Lorentz boost of the W boson. The search is based on proton-proton collision data at $\sqrt{s} = $ 13 TeV, corresponding to an integrated luminosity of 137 fb$^{-1}$, collected with the CMS detector at the LHC in 2016-2018. The W$\gamma$ mass spectrum is parameterized with a smoothly falling background function and examined for the presence of resonance-like signals. No significant excess above the predicted background is observed. Model-specific upper limits at 95% confidence level on the product of the cross section and branching fraction to the W$\gamma$ channel are set. Limits for narrow resonances and for resonances with an intrinsic width equal to 5% of their mass, for spin-0 and spin-1 hypotheses, range between 0.17 fb at 6.0 TeV and 55 fb at 0.7 TeV. These are the most restrictive limits to date on the existence of such resonances. In specific narrow-resonance benchmark models, heavy scalar (vector) triplet resonances with masses between 0.75 (1.15) and 1.40 (1.36) TeV are excluded for a range of model parameters. Model-independent limits on the product of the cross section, signal acceptance, and branching fraction to the W$\gamma$ channel are set for minimum W$\gamma$ mass thresholds between 1.5 and 8.0 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for pair production of boosted Higgs bosons via vector-boson fusion in the $b$$\overline{b}$$b$$\overline{b}$ final state using $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for Higgs boson pair production via vector-boson fusion is performed in the Lorentz-boosted regime, where a Higgs boson candidate is reconstructed as a single large-radius jet, using 140 fb−1 of proton–proton collision data at $\sqrt{s}$ = 13 TeV recorded by the ATLAS detector at the Large Hadron Collider. Only Higgs boson decays into bottom quark pairs are considered. The search is particularly sensitive to the quartic coupling between two vector bosons and two Higgs bosons relative to its Standard Model prediction, K 2V . This study constrains K 2V to 0.55 < K 2V < 1.49 at the 95% confidence level. The value K 2V = 0 is excluded with a significance of 3.8 standard deviations with other Higgs boson couplings fixed to their Standard Model values. A search for new heavy spin-0 resonances that would mediate Higgs boson pair production via vector-boson fusion is carried out in the mass range of 1–5 TeV for the first time under several model and decay-width assumptions. No significant deviation from the Standard Model hypothesis is observed and exclusion limits at the 95% confidence level are derived.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Higgs boson exotic decays into Lorentz-boosted light bosons in the four-τ final state at $\sqrt{s}$ = 13 with the ATLAS detector

A search for exotic decays of the Higgs boson into a pair of low-mass scalars that subsequently decay into τ-leptons, H → aa → τ + τ – τ + τ – , is presented. In models with Yukawa-like couplings, the decay to τ-leptons is favoured for light a-bosons, with mass in the range of 2m τ < m a < 2m b . Results are presented in the range of 4 GeV < m a < 15 GeV using the 140 fb –1 of proton–proton collisions at $\sqrt{s}$ = 13 TeV recorded with the ATLAS detector during Run 2 of the Large Hadron Collider. This search focuses on the scenario where, for both di-τ pairs, one of the τ-leptons decays to hadrons and neutrinos, while the other decays to a muon and neutrinos. In this mass range, the a → τ + τ – is Lorentz-boosted and a dedicated muon removal technique is used to reconstruct the di-τ pairs.

BSM Higgs↗

Search for a boosted Higgs boson decaying to bottom quark pairs in association with a W or Z boson in proton-proton collisions at $\sqrt{s}$ = 13TeV

A search is conducted for standard model Higgs bosons with large transverse momentum ($p_\mathrm{T}$) decaying to bottom quark pairs and produced in association with a hadronically decaying W or Z boson at the LHC. The result is based on a dataset of proton-proton collisions at a center-of-mass energy of 13 TeV collected with the CMS detector in 2016$-$2018, corresponding to an integrated luminosity of 138 fb$^{-1}$. Boosted Higgs, W, and Z boson decays are reconstructed using large-radius jets with $p_\mathrm{T}$$\gt$ 450 GeV and identified with heavy-flavor classifiers based on a graph convolutional neural network. The observed signal strength relative to the standard model expectation is $μ$ = 0.72 $^{+0.75}_{-0.71}$ including statistical and systematic uncertainties.

CMS↗

Fluorinated polythiophenes with ester side chains for boosting the V OC and efficiency in non-fullerene polymer solar cells

As the power conversion efficiency (PCE) of organic photovoltaics (OPVs) approximates the 19 % threshold, wide bandgap (WBG) polythiophenes (PTs) have gained increasing attention due to their simple chemical structures and ease of synthesis, making them promising candidates for large-scale production. However, the benchmark polymer poly(3-hexylthiophene) (P3HT) is limited by its high-lying HOMO energy level, which restricts the open-circuit voltage (V OC ) in solar cells. Here, in this study, we introduce a novel series of PT derivatives (PDC8-T, PDC8-3T, PDC16-3T, and PDC16-3T-2F) featuring ester side chains designed to fine-tune electronic properties through a streamlined three-step synthesis. Additionally, we incorporated a π-spacer to reduce steric hindrance and elongated alkyl side chains to improve solubility and processability. Compared to P3HT, these PT derivatives demonstrate a significant reduction in HOMO energy levels, lowering by approximately 0.3–0.4 eV. Among them, PDC16-3T-2F—with fluorine atom substitution—achieves the lowest HOMO energy level, induces a coplanar molecular conformation, and enhances polymer aggregation behavior. We evaluated these PT derivatives in inverted non-fullerene bulk-heterojunction (NFA BHJ) OPVs. The PDC8-3T device showed a relatively low PCE of 0.69 %, with a V OC of 0.76 V, a short-circuit current density (J SC ) of 3.32 mA/cm 2 , and a fill factor (FF) of 27.3 %. In contrast, the PDC16-3T-2F device achieved an impressive PCE of 7.21 %, with a V OC of 0.85 V, a J SC of 14.60 mA/cm 2 , and an FF of 58.4 %. This remarkable improvement is attributed to the fluorine substitution, which not only enhances molecular orientation but also downshifts the HOMO energy level and further boosts the V OC . Hence, these molecular design strategies have led to a fibrillar bicontinuous interpenetrating network with optimal nanoscale phase separation within the active layer.

14 SOLAR ENERGY↗