Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Numerical simulation of tornado wind loading on structures

A numerical simulation of a tornado interacting with a building was undertaken in order to compare the pressures due to a rotational unsteady wind with that due to steady straight winds used in design of nuclear facilities. The numerical simulations were performed on a two-dimensional compressible hydrodynamics code. Calculated pressure profiles for a typical building were then subjected to a tornado wind field and the results were compared with current quasisteady design calculations. The analysis indicates that current design practices are conservative.

Maiden, D. E.↗

Inspection design using 2D phased array, TFM and cueMAP software

A simulation suite, cueMAP, has been developed to facilitate the design of inspection processes and sparse 2D array configurations. At the core of cueMAP is a Total Focusing Method (TFM) imaging algorithm that enables computer assisted design of ultrasonic inspection scenarios, including the design of bespoke array configurations to match the inspection criteria. This in-house developed TFM code allows for interactive evaluation of image quality indicators of ultrasonic imaging performance when utilizing a 2D phased array working in FMC/TFM mode. The cueMAP software uses a series of TFM images to build a map of resolution, contrast and sensitivity of imaging performance of a simulated reflector, swept across the inspection volume. The software takes into account probe properties, wedge or water standoff, and effects of specimen curvature. In the validation process of this new software package, two 2D arrays have been evaluated on 304n stainless steel samples, typical of the primary circuit in nuclear plants. Thick section samples have been inspected using a 1MHz 2D matrix array. Due to the processing efficiency of the software, the data collected from these array configurations has been used to investigate the influence sub-aperture operation on inspection performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Highlight: NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact Sheet)

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home's air conditioning equipment. An efficiency validation method for mini-split heat pumps (MSHPs) - highly efficient refrigerant-based air conditioning and heating systems that permit room-by-room conditioning and control - will enable building researchers to easily explore the installed performance of this class of equipment. MSHPs are very popular overseas and are gaining market share in energy efficient home upgrades throughout the United States. Yet, because MSHPs have multiple variable-speed components that work in tandem, their performance is challenging to measure in a real home. NREL researchers developed a field evaluation method including test equipment, methods, and data analysis to determine the installed performance of this equipment in occupied homes. A field test was conducted to validate the method. When testing a home's operation, it is often important to simulate occupancy within an unoccupied home. That way, the researcher will know the actual usage profiles for heat and moisture generation; this removes the uncertainty associated with real occupants. The second test method details a standardized protocol for generating heat and moisture loads, to mimic occupants and their activities by using heaters and humidifiers. Realistic heat and moisture loads can be used to drive air conditioning systems, evaluate air distribution systems, and examine building enclosure technologies. These loads are drawn from the Building America House Simulation Protocols. Proper application of the method will result in better comparison between performance of the test home and its simulated analogue. This method is also validated by field testing. These test methods are now available in two technical reports. The methods can be used widely by the building research community to confirm proper operation of space conditioning equipment in homes, thereby improving thermal comfort, building health, and durability. National objectives for cost-effective energy savings in the residential sector can be met more quickly and with greater consistency.

14 SOLAR ENERGY↗

Validation of Fitness for Duty Standards Using Pre- and Post-Flight Capsule Egress and Suited Functional Performance Tasks in Simulated Reduced Gravity (Pilot Egress Fitness)

As NASA prepares for exploration missions, it will be critical to understand and build upon known crew capabilities. Specifically, we need to know the functional capacities of crew at different stages of a mission and characterize these profiles so that the appropriate vehicle requirements and mission concepts of operations (ConOps) can be developed. One of the most complex phases of any missions is when there is a transition between gravity environments. For instance, both physiological adaptation to microgravity and subsequent re-entry into a gravity environment result in reduced functional capacity, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk tasks may have to be performed soon after gravity transitions: •Unassisted capsule egress task after return to Earth •Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study has been broken down into two phases. A pilot phase to assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing and the full Egress Fitness study, which will be part of the CIPHER complement. This study uses a functional task approach to characterize performance of these high-risk tasks in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and mobility to be able to complete the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth based emergency egress out of a functional capsule mockup, and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing can occur almost anytime pre-flight, but post-flight scheduling is much more critical with the capsule egress test occurring 1-4 hours after landing and the planetary EVA approximately 18-36 hours after landing. Data collected for both tasks includes task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed baseline pre-flight testing on 3 astronaut subjects. Post-flight testing of the first two subjects will be completed in November 2021 and the final subject around March 2022. Results and lessons learned from this pilot study will inform the full Egress Fitness study, which will incorporate additional pre-flight sessions, longer EVA tasks, and post-flight testing on R+1, 4, and 7 to characterize the timeframe of recovery

J R Norcross↗

Analysis of Debris Trajectories at the Scaled Wind Farm Technology (SWiFT) Facility

Sandia National Laboratories operates the Scaled Wind Farm Technology Facility (SWiFT) on behalf of the Department of Energy Wind and Water Power Technologies Office. An analysis was performed to evaluate the hazards associated with debris thrown from one of SWiFT’s operating wind turbines, assuming a catastrophic failure. A Monte Carlo analysis was conducted to assess the complex variable space associated with debris throw hazards that included wind speed, wind direction, azimuth and pitch angles of the blade, and percentage of the blade that was separated. In addition, a set of high fidelity explicit dynamic finite element simulations were performed to determine the threshold impact energy envelope for the turbine control building located on-site. Assuming that all of the layered, independent, passive and active engineered safety systems and administrative procedures failed (a 100% failure rate of the safety systems), the likelihood of the control building being struck was calculated to be less than 5/10,000 and ballistic simulations showed that the control building would not provide passive protection for the majority of impact scenarios. Although options exist to improve the ballistic resistance of the control building, the recommendation is not to pursue them because there is a low probability of strike and there is an equal likelihood personnel could be located at similar distances in other areas of the SWiFT facility which are not passively protected, while the turbines are operating. A fenced exclusion area has been created around the turbines which restricts access to the boundary of the 1/100 strike probability. The overall recommendation is to neither relocate nor improve passive protection of the control building as the turbine safety systems have been improved to have no less than two independent, redundant, high quality engineered safety systems. Considering this, in combination with a control building strike probability of less than 5/10,000, the overall probability of turbine debris striking the control building is less than 1/1,000,000.

17 WIND ENERGY↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rethinking Occupancy - Based Ventilation Controls

Traditionally, occupancy-based ventilation controls have only ventilated when occupants are present – usually based on measurements of CO2 and/or humidity. These indictors may be fine for pollutants released directly by occupants, such as bioeffluents, or by their activities, such as cooking and cleaning. However, they do not account for pollutants not associated with occupancy, such as formaldehyde from building materials and furnishings. In this study we examined how occupancy-based ventilation controls could account for these other pollutants using the relative exposure approach for variable ventilation. A real-time control was used for exhaust and balanced fans, three occupancy schedules and two different pollutant emission assumptions using the REGCAP ventilation and residential energy simulation program. The simulations were performed for a prototype high performance home compliant with U.S. Department of Energy Building America Zero Energy Ready program requirements in the 15 climate zones defined by the U.S. DOE. Median ventilation energy savings were between zero and 26% of ventilation-related energy use depending on the occupancy schedule, climate, fan type and emission assumptions. Occupancy-based control savings increased for balanced ventilation fans, reduced emissions during unoccupied periods, and longer unoccupied times. Accounting for pollutant emissions during unoccupied times significantly reduces the energy savings for occupancy-based controls.

Walker, Iain↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-QI-15: Single Point Dosimetry by Means of Cerenkov Radiation Energy Transfer (CRET)

Purpose: Cerenkov light is generated when a charged particles with energy greater then 250 keV, moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons during the static megavoltage linear accelerator (LINAC) operational mode. Recently, Cerenkov radiation gained considerable interest as possible candidate as a new imaging modality. Optical signals generated by Cerenkov radiation may act as a surrogate for the absorbed superficial radiation dose. We demonstrated a novel single point dosimetry method for megavoltage photon and electron therapy utilizing down conversion of Cerenkov photons. Methods: The custom build signal characterization system was used: a sample holder (probe) with adjacent light tight compartments was connected via fiber-optic cables to a photon counting photomultiplier tube (PMT). One compartment contains a medium only while the other contains medium and red-shifting nano-particles (Q-dots, nanoclusters). By taking the difference between the two signals (Cerenkov photons and CRET photons) we obtain a measure of the down-converted light, which we expect to be proportional to dose as measured with an adjacent ion chamber. Experimental results are compared to Monte Carlo simulations performed using the GEANT4 code. Results: The signal correlation between CR signal, CRET readings and dose produced by LINAC at a single point were investigated. The experimental results were compared with simulations. The dose linearity, signal to noise ratio and dose rate dependence were tested with custom build CRET based probe. Conclusion: Performance characteristics of the proposed single point CRET based probe were evaluated. The direct use of the induced Cerenkov emission and CRET in an irradiated single point volume as an indirect surrogate for the imparted dose was investigated. We conclude that CRET is a promising optical based dosimetry method that offers advantages over those already proposed.

60 APPLIED LIFE SCIENCES↗

Photoinduced non-adiabatic energy transfer pathways in dendrimer building blocks

The efficiency of the intramolecular energy transfer in light harvesting dendrimers is determined by their well-defined architecture with high degree of order. After photoexcitation, through-space and through-bond energy transfer mechanisms can take place, involving vectorial exciton migration among different chromophores within dendrimer highly branched structures. Their inherent intramolecular energy gradient depends on how the multiple chromophoric units have been assembled, subject to their inter-connects, spatial distances, and orientations. Herein, we compare the photoinduced nonadiabatic molecular dynamics simulations performed on a set of different combinations of a chain of linked dendrimer building blocks composed of two-, three-, and four-ring linear polyphenylene chromophoric units. The calculations are performed with the recently developed ab initio multiple cloning-time dependent diabatic basis implementation of the Multiconfigurational Ehrenfest (MCE) approach. Despite differences in short time relaxation pathways and different initial exciton localization, at longer time scales, electronic relaxation rates and exciton final redistributions are very similar for all combinations. Unlike the systems composed of two building blocks, considered previously, for the larger 3 block systems here we observe that bifurcation of the wave function accounted by cloning is important. In all the systems considered in this work, at the time scale of few hundreds of femtoseconds, cloning enhances the electronic energy relaxation by ~13% compared to that of the MCE method without cloning. Thus, accurate description of quantum effects is essential for understanding of the energy exchange in dendrimers both at short and long time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY22 Laboratory Directed Research and Development Annual Report

The Laboratory Directed Research and Development (LDRD) program yields foundational scientific research and development (R&D) essential to growing SRNL’s core competencies, in alignment with SRNL’s Strategic Plan to provide long-term benefits to the Department of Energy (DOE), the National Nuclear Security Administration (NNSA), and other customers and stakeholders. Five strategic goals are outlined in SRNL’s strategic plan: 1) Provide applied science and engineering for EM’s active clean-up sites and LM’s post closure management sites; 2) Provide science-based solutions for gaps identified in nonproliferation strategic vision and support the government in actives impacting national security; 3) Lead ST&E as the central technical authority for processing tritium loaded reservoirs and support production of plutonium pits; 4) Align science and energy security programs by focusing modern modeling, simulation, and data analytics tools on materials engineering and performance applications; 5) Build a workforce for the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyses to Verify and Improve the Accuracy of the Manufactured Home Energy Audit (MHEA)

A series of analyses were performed to determine the reasons that the Manufactured Home Energy Audit (MHEA) over predicted space-heating energy savings as measured in a recent field test and to develop appropriate corrections to improve its performance. The study used the Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) to verify that MHEA accurately calculates the UA-values of mobile home envelope components and space-heating energy loads as compared with other, well-accepted hourly energy simulation programs. The study also used the Procedures for Verification of RESNET Accredited HERS Software Tools to determine that MHEA accurately calculates space-heating energy consumptions for gas furnaces, heat pumps, and electric-resistance furnaces. Even though MHEA's calculations were shown to be correct from an engineering point of view, three modifications to MHEA's algorithms and use of a 0.6 correction factor were incorporated into MHEA to true-up its predicted savings to values measured in a recent field test. A simulated use of the revised version of MHEA in a weatherization program revealed that MHEA would likely still recommend a significant number of cost-effective weatherization measures in mobile homes (including ceiling, floor, and even wall insulation and far fewer storm windows). Based on the findings from this study, it was recommended that a revised version of MHEA with all the changes and modifications outlined in this report should be finalized and made available to the weatherization community as soon as possible, preferably in time for use within the 2009 Program Year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine

A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.

Hurlbert, Eric A.↗