Search NASA⌕ Search

SEARCH · Search NASA

Results for “CERTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Dynamic System Scaling Applied to Zr-4 Cladding under RIA Conditions

The research and development lifecycle for new fuel designs currently has an ideal 20-25 year timeline. Efforts are currrently underway to accelerate fuel design and development using high performance fuel modeling codes and reduced scale experiments with new instrumentation techniques. However current tools available require a full scale prototype to be designed and tested for fuel qualification. The thermal-hydraulics community has leveraged scaling methodologies to use reduced scale integral effect test facilities (Westinghouse AP600/1000, NuScale Power Module) in lieu of building full scale prototypes for reactor design certification. Dynamic System Scaling (DSS) is a recent development to scaling methodologies that enable the tracking and quantification of dynamic scaling distortions experienced throughout a transient. Recent TREAT experiments performed reactivity initiated accident (RIA) pulses on UO2 fuel rodlets in Zr-4 cladding and were accompanied by BISON predictions for the cladding temperature. DSS is applied to pyrometer data of outer cladding temperatures and two BISON predictions after peak cladding temperature has been reached. One BISON case uses a constant gap conductance value between the fuel and cladding and the other using a conventional gap conductance model. Results from the DSS analysis show that there is good agreement between both BISON predictions and the experimental data and that there is not a significant distortion seen between using either gap conductance model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined-Accelerated Stress Testing for Advanced Reliability Assessment of Photovoltaic Modules

New and previously undiscovered degradation mechanisms continue to be identified after field exposure in new photovoltaic module designs or materials oftentimes results in significant losses in investment. This is despite passing certification tests. Testing is insufficient largely due to their single-or double-stress nature. A Combined-Accelerated Stress Test (C-AST) has recently been developed. The test combines multiple stress factors of the natural environment to better replicate conditions experienced by modules in the field and detect mechanisms not a-priori known in new materials and designs.

accelerator factor modeling↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

IS BLOCKCHAIN A SUITABLE TECHNOLOGY FOR ENSURING THE INTEGRITY OF DATA SHARED BY LIGHTING AND OTHER BUILDING SYSTEMS?

Increasing amounts of data are available from lighting and other building systems. In commercial buildings, these data can be used to improve system and energy performance, detect and diagnose faults, and facilitate maintenance. Building data are not only of interest to owners and operators of the building systems, however. Owners and operators of similar buildings, manufacturers of building systems, utilities, and city agencies also have interesting use cases. Energy data can, for example, be used to verify the performance of energy-conservation measures, issue renewableenergy certificates, and financially settle grid services. Increased data sharing, however, significantly expands the cyber-attack surface, creating new challenges. In this work, blockchain is explored as an option for ensuring the integrity of data that are shared by lighting and other building systems. Blockchain fundamentals and variants are briefly reviewed, and value propositions relevant to building systems are discussed. A recently developed blockchain applicability framework (BAF) that builds upon and addresses the limitations of previous applicability models is also briefly reviewed. The BAF is used to assess the suitability of blockchain over other technologies or approaches for building-data applications, using emerging connected lighting systems as an example use case.

blockchain, connected lighting system, data integr↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Competitiveness Improvement Project 2020 Informational Workshop

These presentations from the Dec. 8, 2020, Competitiveness Improvement Project (CIP) workshop provide an overview of the CIP process, evaluation criteria, certification requirements, and NREL's technical support opportunities for those interested in applying to CIP solicitations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

FTS3: Data Movement Service in containers deployed in OKD

The File Transfer Service (FTS3) is a data movement service developed at CERN which is used to distribute the majority of the Large Hadron Collider's data across the Worldwide LHC Computing Grid (WLCG) infrastructure. At Fermilab, we have deployed FTS3 instances for Intensity Frontier experiments (e.g. DUNE) to transfer data in America and Europe, using a container-based strategy. In this article we summarize our experience building docker images based on work from the SLATE project (slateci.io) and deployed in OKD, the community distribution of Red Hat OpenShift. Additionally, we discuss our method of certificate management and maintenance utilizing Kubernetes CronJobs. Finally, we also report on the two different configurations currently running at Fermilab, comparing and contrasting a Docker-based OKD deployment against a traditional RPM-based deployment.

Lobato Pardavila, Lorena↗

The CYBER security – Competency Health and Maturity Progression (CYBER-CHAMP) model: Extending the National Initiative for Cybersecurity Education (NICE) Framework Across Organizational Security

Problem Statement: There is a pervasive talent deficit in the cybersecurity industry that prevents employers from being able to fill their open positions efficiently. A holistic approach to security is required to ensure organizations have adequate prevention and response capabilities in case of a cyberattack. Specifically, industrial control systems (ICS’s) and their operational technology (OT) components have become a constant target for cyberattacks. Research Questions: It is proposed that the NICE Framework should be extended in the following areas: 1) Include guidance regarding the job roles and competencies for both IT and OT professionals. 2) Offer step-by-step solutions, based on the work role mappings from the NICE Framework, to increase cybersecurity through employee training and education. 3) Provide a streamlined, lifecycle approach to building a cybersecurity program. Contribution: The CYBER security – Competency Health and Maturity Progression (CYBER-CHAMP©) model provides a customized solution for businesses to understand their education gaps in organizational security and target areas for improvement. Rationale: The Framework for Improving Critical Infrastructure Cybersecurity v1.1 addresses ICS but does not offer a measurement of cybersecurity maturity or clear methods to ascertain an organization’s current risk profile. In Phases 1 and 5 of the model, measurements are provided to help an organization build their current and target risk profiles. The NICE framework provides a structure for planning an IT cybersecurity workforce, but the OT aspects of cybersecurity are only briefly discussed. The model uses Phases 2-3 to examine the competencies of an organization’s workforce, which includes both IT and OT roles. Current frameworks do not offer next steps to increase an organization’s cybersecurity. During Phase 4, employees’ roles are mapped to training, education, and/or certifications from common vendors. Investigative Approach: The model provides measurements and metrics for both an organization’s status and continual improvement. This improvement methodology includes guidance for creating an overall strategic plan for security improvement via products designed to increase an organization’s operational readiness through workforce competency health. Lessons Learned: Depending on who was participating, there were contradicting answers given in Phase 1 due to different security cultures in the organization. This revelation has influenced the steps listed in the User’s Guide, where Phase 1’s first recommended step is to assemble a team that champions the facilitation and implementation of the model in the organization. During Phase 2, the discovery was made that organizations may be missing roles that are necessary to perform critical cybersecurity functions. By understanding the functional roles and competencies needed, they can contract or hire cybersecurity help to fill these gaps. Implications: Using the model, organizations can discuss quantitative measures for improvement as a business case for advancing their security program. Future research can validate and extend the present theory and model to a variety of environments. It is of interest to investigate additional security roles and knowledge domains that are used to build standardized cybersecurity curriculum.

97 MATHEMATICS AND COMPUTING↗

Status and Trends in the Voluntary Market (2020 Data)

Green power refers to renewable electricity voluntarily purchased by retail electricity customers. Renewable energy sources for green power include solar, wind, biomass, geothermal, and small-scale hydropower. This report summarizes data on the various ways in which voluntary purchasers - including residential, commercial, and institutional customers - purchase green power. We summarize key historic trends in U.S. voluntary green power markets and the current status of green power sales through seven products: utility green pricing programs, utility renewable contracts, competitive suppliers, unbundled renewable energy certificates, community choice aggregations, and power purchase agreements. It includes discussion of how the voluntary market may impact the grid.

community choice aggregation↗

Challenges of Interpreting and Applying New IPC-J-STD-001 Cleanliness Standards in High-Reliability Applications

The electronics industry has rapidly and widely embraced the replacement of ROSE testing with an SIR-focused approach to testing for certification of a qualified manufacturing plan. These new cleanliness documentation standards, housed in IPC J-STD-001 Rev. H, have just begun to impact electronics manufacturers as design and production teams work through how to meet them. This research focuses on the particular challenges of applying these new standards in high-reliability product applications, through the lens of interpreting SIR test results and what they mean for process capability, repeatability and diagnosing a need for process changes. The experiments examined a variety of factors that influence SIR results and suggest areas where SIR test plans can be greatly improved.

Capen, William↗

Weatherization Updates From the National Renewable Energy Laboratory

The National Renewable Energy Laboratory (NREL) provides technical assistance and research to support high-quality work and highly qualified workers in the weatherization and home performance industry. NREL staff will provide updates on their work on the Standard Work Specifications, Home Energy Professional Certifications, Continuous Improvement Workshops, workforce training and research, and other topics.

continuous improvement↗

OPF-Learn: An Open-Source Framework for Creating Representative AC Optimal Power Flow Datasets: Preprint

Increasing levels of renewable generation motivate a growing interest in data-driven approaches for AC optimal power flow (AC OPF) to manage uncertainty. However, a lack of disciplined dataset creation and benchmarking prohibits useful comparison between approaches in the literature. To instigate confidence, models must be able to reliably predict solutions across a wide range of operating conditions. This paper develops the OPF-Learn package for Julia and Python which uses a computationally efficient approach to create representative datasets that span a wide spectrum of the AC OPF feasible region. Load profiles are uniformly sampled from a convex set that contains the AC OPF feasible set. For each infeasible point found, the convex set is reduced using infeasibility certificates, found by utilizing properties of a relaxed formulation. The framework is shown to generate datasets which are more representative of the entire feasible space versus traditional techniques seen in the literature, improving machine learning model performance.

dataset↗

Investigation of INL Site Implementation of ARG-US

The Packaging Certification and Life Cycle Management department at Argonne National Laboratory (ANL) developed a suite of monitoring systems collectively referred to here as ARG-US. ARG-US is used to provide necessary data for nuclear facility and system operation and maintenance. ARG-US has been previously demonstrated in hot cells, radioactive material (RAM) storage areas, and RAM shipment trucks. It has also been installed directly on RAM storage and shipment containers. ARG-US offers some unique advantages over other commercially available systems by using wireless data connections, battery power supplies, and customizable monitoring methods. Idaho National Laboratory (INL) has been tasked with investigating applications for ARG-US at INL site facilities, which are operated by several different contractors. The initial investigation scope centered on CPP-603 Wet & Dry Fuel Storage Facility in relation to the upcoming DOE Spent (SNF) Packaging Demonstration. The investigation has been led by the Used Fuel Management Department in the Nuclear Science and Technology Directorate. This investigation is expected to recommend processes or facilities at the INL site at which to implement ARG-US systems. INL has engaged local site technical and oversite representatives, security, nuclear safeguards, and program management to identify good candidates for ARG-US test implementations. INL has identified high-level goals for any INL site implementation of ARG-US: provide unique testing environments, prompt development of new monitoring methods/techniques for the ARG-US suite, and acquire useful monitoring for the user facility. To these ends, INL suggests 3 program areas for further investigation: CPP-603 Fuel Handling Cave (FHC), legacy mixed waste storage systems at Idaho Nuclear Technology & Engineering Center (INTEC) known as the “tank farm”, and periodic and emergency environmental monitoring. This progress report relates activities undertaken in this investigation, describes the preliminary areas of interest for limited scope ARG-US testing or implementation, and relays expected actions needed to complete the task scope. This report offers an opportunity to the program sponsor, technical leads at ANL, and INL site representatives to give feedback on the initial assessment and make recommendations on the forthcoming activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

Building Envelope Characteristics in Cold Climates

Prescriptive guidelines for thermal insulation in the design of buildings in cold climates have traditionally been derived by a holistic consideration of climatic factors, energy policy, environmental policy, and economics. The differences in thermal barrier requirements in buildings across the arctic and subarctic regions of the world are influenced as much by the differing priorities of the governing bodies that set these requirements as by actual physical demands and conditions. Usually, national requirements for building envelope characteristics such as thermal insulation values, building envelope airtightness, vapor permeability, building mass, and detailing are based on economics, durability, and environmental considerations. Consideration of thermal energy system resilience provides a new paradigm through which to view the optimization of these parameters. The paper describes specifics of construction in cold climates; summarizes best practice requirements for the building envelope characteristics for buildings located in cold and arctic climate of the United States, Canada, and Scandinavian countries; provides some details illustrating how to implement these requirements; and compares the effects of different levels of building envelope efficiency and building mass on indoor air temperature decay when heat supply is interrupted. The paper also presents results from experts' discussions during the consultation forum "Thermal Energy Systems Resilience in Cold/Arctic Climates" (ERDC 2020) and research conducted under the IEA EBC Annex 73, the Environmental Security Technology Certification Program (ESTCP) Project "Technologies Integration to Achieve Resilient, Low-Energy Military Installations," and U.S. Army Program project 633734T1500 under Military Engineering Technology Demonstration. The paper complements the Cold-Climate Design Guide (ASHRAE 2015) with a focus on the resilience of thermal energy systems.

Arctic↗

How Does Home Energy Score Affect Home Value and Mortgage Performance?

Energy-efficient homes save their occupants money through lower energy bills. These savings might be capitalized into higher home sale prices. They also improve the household’s net cash flow, which might make households better able to pay mortgage debt. The U.S. Department of Energy (DOE)’s Home Energy Score (HES) assigns a 1-10 score to homes and estimates annual energy bills based on modeled energy consumption. In this paper we investigated the relationship between HES metrics and two housing market outcomes: home sale price and mortgage performance. We found that the relationship was only statistically significant in places with a mandatory HES assessment at the time of sale. Using a sample of 26,291 home sales that occurred after HES assessments, we found that a one-point increase in HES in these locations was associated with a 0.5% increase in sale price, and an increase in $100 of estimated annual energy bills was associated with a 0.4% decrease. This magnitude of effect is consistent with estimated magnitudes of home sale premiums for other green or energy-efficient home certifications in the literature. We also found that a one-point increase in HES was associated with a 5.5% reduction in the odds of a loan going 30 days delinquent if the loan originated after the assessment occurred. Similarly, we found that a $100 decrease in estimated annual energy bills was associated with a 2.3% decrease in the odds of a loan going delinquent if it originated after the assessment occurred. Our results suggest that HES provides a valuable signal for housing market transactions in specific situations.

Pigman, Margaret↗

Status and Trends in the Voluntary Market (2021 Data)

Green power refers to renewable electricity voluntarily purchased by retail electricity customers. Renewable energy sources for green power include solar, wind, biomass, geothermal, and small-scale hydropower. This report summarizes data on the various ways in which voluntary purchasers including residential, commercial, and institutional customers purchase green power. We summarize key historic trends in U.S. voluntary green power markets and the current status of green power sales through seven products: utility green pricing programs, utility renewable contracts, competitive suppliers, unbundled renewable energy certificates, community choice aggregations, and power purchase agreements. It includes discussion of how the voluntary market may impact the grid.

ENERGY PLANNING, POLICY, AND ECONOMY↗