Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis

In relation to developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. Lastly, we then couple this micro HPLC with an electrospray ionization – mass spectrometer for peptide and protein separations and identifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of the influence of the heat generated by viscous friction on the efficiency of chromatography columns

The combination of the heat balance in a chromatographic column percolated by a stream of mobile phase and of the model of band migration under linear conditions along such a column permits the calculation of the axial and radial temperature distributions in the column, of the elution band profiles, and of the column efficiency under different sets of experimental conditions. The calculated results are always consistent with the experimental results published by different groups and often in good quantitative agreement. Minor discrepancies arise from difficulties in deriving precise estimates of the heat transfers from the column due to the massive endfittings of the column and to uncontrolled heat transfer from the column tube to ambient air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of the performance of a few packing materials designed to minimize the thermodynamic band tailing of basic compounds in reversed-phase liquid chromatography

The adsorption isotherms of phenol, caffeine, propranolol chloride, and amitriptyline chloride were measured on three new brands of C{sub 18}-bonded silica that have been designed to be more resistant than conventional C{sub 18}-bonded silica at high pHs (>8). These columns were the 4 {micro}m Bidendate Cogent-C{sub 18} (Microsolv Technology Corporation, Long Branch, NJ, USA), the 3.5 {micro}m Zorbax Extend-C{sub 18} (Agilent Technologies, Palo Alto, CA, USA), and the 5 {micro}m XTerra-C{sub 18} (Waters, Milford, MA, USA). The originality of these adsorbents is due to their surface chemistry, which protects them from rapid hydrolysis or dissolution at extreme pH conditions. Their adsorption properties were compared to those of the 3 {micro}m Luna-C{sub 18} (Phenomenex, Torrance, CA), which is a more conventional monofunctional material. The adsorption data were acquired by frontal analysis (FA) and the adsorption energy distributions (AEDs) of all systems studied were calculated by the expectation-maximization (EM) method. The experimental results show that neither a simple surface protection (Extend-C{sub 18}) nor the elimination of most of the silanol groups (Cogent-C{sub 18}) is sufficient to avoid a peak tailing of the basic compounds at pH 8 that is of thermodynamic origin. The incorporation of organic moieties in the silica matrix, which was achieved in XTerra-C{sub 18}, the first generation of hybrid methyl/silica material, reduces the silanols activity and is more successful in reducing this peak tailing.

36 MATERIALS SCIENCE↗

Adsorption mechanism of acids and bases in reversed-phase liquid chromatography in weak buffered mobile phases designed for liquid chromatography/mass spectrometry

The overloaded band profiles of five acido-basic compounds were measured, using weakly buffered mobile phases. Low buffer concentrations were selected to provide a better understanding of the band profiles recorded in LC/MS analyses, which are often carried out at low buffer concentrations. In this work, 10 {micro}L samples of a 50 mM probe solution were injected into C{sub 18}-bonded columns using a series of five buffered mobile phases at {sub W}{sup S}pH between 2 and 12. The retention times and the shapes of the bands were analyzed based on thermodynamic arguments. A new adsorption model that takes into account the simultaneous adsorption of the acidic and the basic species onto the endcapped adsorbent, predicts accurately the complex experimental profiles recorded. The adsorption mechanism of acido-basic compounds onto RPLC phases seems to be consistent with the following microscopic model. No matter whether the acid or the base is the neutral or the basic species, the neutral species adsorbs onto a large number of weak adsorption sites (their saturation capacity is several tens g/L and their equilibrium constant of the order of 0.1 L/g). In contrast, the ionic species adsorbs strongly onto fewer active sites (their saturation capacity is about 1 g/L and their equilibrium constant of the order of a few L/g). From a microscopic point of view and in agreement with the adsorption isotherm of the compound measured by frontal analysis (FA) and with the results of Monte-Carlo calculations performed by Schure et al., the first type of adsorption sites are most likely located in between C{sub 18}-bonded chains and the second type of adsorption sites are located deeper in contact with the silica surface. The injected concentration (50 mM) was too low to probe the weakest adsorption sites (saturation capacity of a few hundreds g/L with an equilibrium constant of one hundredth of L/g) that are located at the very interface between the C{sub 18}-bonded layer and the bulk phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak shapes of acids and bases under overloaded conditions in reversed-phase liquid chromatography, with weakly buffered mobile phases of various pH: A thermodynamic interpretation

We measured overloaded band profiles for a series of nine compounds (phenol, caffeine, 3-phenyl 1-propanol, 2-phenylbutyric acid, amphetamine, aniline, benzylamine, p-toluidine, and procainamidium chloride) on columns packed with four different C{sub 18}-bonded packing materials: XTerra-C{sub 18}, Gemini-C{sub 18}, Luna-C{sub 18}(2), and Halo-C{sub 18}, using buffered methanol-water mobile phases. The {sub W}{sup S}pH of the mobile phase was increased from 2.6 to 11.3. The buffer concentration (either phosphate, acetate, or carbonate buffers) was set constant at values below the maximum concentration of the sample in the band. The influence of the surface chemistry of the packing material on the retention and the shape of the peaks was investigated. Adsorbents having a hybrid inorganic/organic structure tend to give peaks exhibiting moderate or little tailing. The retention and the shape of the band profiles can easily be interpreted at {sub W}{sup S}pHs that are well above or well below the {sub W}{sup S}pK{sub a} of the compound studied. In contrast, the peak shapes in the intermediary pH range (i.e., close to the compound {sub W}{sup S}pK{sub a}) have rarely been studied. These shapes reveal the complexity of the competitive adsorption behavior of couples of acido-basic conjugated compounds at {sub W}{sup S}pHs that are close to their {sub W}{sup S}pK{sub a}. They also reveal the role of the buffer capacity on the resulting peak shape. With increasing {sub W}{sup S}pH, the overloaded profiles are first langmuirian (isotherm type I) at low {sub W}{sup S}pHs, they become S-shaped (isotherm type II), then anti-langmuirian (isotherm type III), S-shaped again at intermediate {sub W}{sup S}pHs, and finally return to a langmuirian shape at high {sub W}{sup S}pHs. A new general adsorption isotherm model that takes into account the dissociation equilibrium of conjugated acidic and basic species in the bulk mobile phase accounts for these transient band shapes. An excellent agreement was achieved between experimental profiles and those calculated with a two-sites adsorption isotherm model at all {sub W}{sup S}pHs. The neutral species adsorbs strongly on a first type of sites that have a high density while the ionic species adsorb preferentially on a second type of sites that have a very low density. The evolution of the peak shape when the {sub W}{sup S}pH changes from acidic to basic is well explained by the weak buffer capacity of the mobile phase used compared to the concentration of the eluted compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequences in two-dimensional high-performance liquid chromatography

The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was greater than the injection plug viscosity. Under the first condition, retention time and elution performance decreased as the viscosity contrast between the mobile phase and injection plug increased. The effect on performance was more marked as the injection volume increased. A decrease in performance of 12% for compounds with retention factors up to 2.8 was apparent even when the viscosity contrast was only 0.165 cP. In the second set of conditions, elution performance was actually observed to increase, by as much as 25% for a 40 {micro}L injection, as the viscosity contrast between the mobile phase and the solute plug increased. No change in the retention factor was observed. This behaviour was attributed to the shape of an injection plug as it enters into the column, whereby a low viscosity plug permeates away from the wall when the column contains a higher viscosity mobile phase, and vice a versa for a high viscosity plug entering a low viscosity mobile phase. At no stage was either a band splitting or shoulders observed with viscosity contrasts up to 1.283 cP, as could have been expected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of thermal processes in high pressure liquid chromatography. I. Low pressure onset of thermal heterogeneity

Heat due to viscous friction is generated in chromatographic columns. When these columns are operated at high flow rates, under a high inlet pressure, this heat causes the formation of significant axial and radial temperature gradients. Consequently, these columns become heterogeneous and several physico-chemical parameters, including the retention factors and the parameters of the mass transfer kinetics of analytes are no longer constant along and across the columns. A robust modeling of the distributions of the physico-chemical parameters allows the analysis of the impact of the heat generated on column performance. We developed a new model of the coupled heat and mass transfers in chromatographic columns, calculated the axial and radial temperature distributions in a column, and derived the distributions of the viscosity and the density of the mobile phase, hence of the axial and radial mobile phase velocities. The coupling of the mass and the heat balances in chromatographic columns was used to model the migration of a compound band under linear conditions. This process yielded the elution band profiles of analytes, hence the column efficiency under two different sets of experimental conditions: (1) the column is operated under natural convection conditions; (2) the column is dipped in a stream of thermostated fluid. The calculated results show that the column efficiency is remarkably lower in the second than in the first case. The inconvenience of maintaining constant the temperature of the column wall (case 2) is that retention factors and mobile phase velocities vary much more significantly across the column than if the column is kept under natural convection conditions (case 1).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metabolism and pharmacokinetics of the combination Zidovudine plus Lamivudine in the adult Erythrocebus patas monkey determined by liquid chromatography-tandem mass spectrometric analysis

Because of their similarity to humans, non-human primates constitute useful preclinical models in which to examine potential human drug toxicities. Antiretroviral nucleoside reverse transcriptase inhibitor (NRTI) toxicity is currently under investigation in Erythrocebus patas monkeys, and whereas NRTI pharmacokinetics have been studied in other monkey species, pharmacokinetics for Zidovudine plus Lamivudine (AZT/3TC) dosing have not been reported in the patas. Here we present 24 h serum pharmacokinetic parameters after a single oral exposure to the combination of AZT (40 mg) and 3TC (24 mg), doses equivalent to a human daily dose of Combivir (registered) . The patas (n = 3) AZT/3TC pharmacokinetic profiles were similar to those seen in other primate species. Average maximum serum concentrations (C{sub max}) for AZT and 3TC were 2.35 and 2.65 {mu}g/ml, respectively, and were observed at 0.83 h (T{sub max}). C{sub max} was 13.34 {mu}g/ml for the AZT-glucuronide (AZT-G) and was 0.023 {mu}g/ml for the potentially toxic minor metabolite 3'-amino-3'-deoxythymidine (AMT), both occurring at about 1 h after dosing. Similar elimination half-times, 0.70 and 0.68 h{sup -1}, were found for AZT and AZT-G, respectively, while 3TC was eliminated about half as fast (0.33 h{sup -1}) resulting in AUC{sub (0-{infinity})} values of 6.97 {mu}g/ml h for 3TC, 2.99 {mu}g/ml h for AZT, 20.5 {mu}g/ml h for AZT-G and 0.002 for AMT 6.97 {mu}g/ml h. This study shows similar metabolism and pharmacokinetics for oral administration of AZT/3TC in the adult patas monkey, other primate species and humans. The data validate the use of the patas monkey for studies of NRTI toxicity.

60 APPLIED LIFE SCIENCES↗

Characterization of Diesel Fuel by Chemical Separation Combined with Capillary Gas Chromatography (GC) Isotope Ratio Mass Spectrometry (IRMS)

The purpose of this study was to perform a preliminary investigation of compound-specific isotope analysis (CSIA) of diesel fuels to evaluate whether the technique could distinguish between the diesel samples from different sources/locations. The ability to differentiate or correlate diesel samples could be valuable for detecting fuel tax evasion schemes. Two fractionation techniques were used to isolate the n-alkanes from the fuel. Both δ13C and δD values for the n-alkanes were then determined by CSIA in each sample. Plots of δD versus δ13C with sample n-alkane points connected in order of increasing carbon number gave well separated clusters with characteristic shapes for each sample. Principal components analysis (PCA) with δ13C, δD, or combined δ13C and δD data on the yielded scores plots that could clearly differentiate the samples, thereby demonstrating the potential of this approach for fingerprinting fuel samples using the δ13C and δD values.

compound specific isotope ratio mass spectrometry↗

Improved Resolution of Hydrocarbon Structures and Constitutional Isomers in Complex Mixtures Using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry

Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography/mass spectrometry (GC/MS) techniques. In this study, we use vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally “unresolved complex mixture” by separating components by GC retention time, t R , and mass-to-charge ratio, m/z, which are used to determine carbon number, N C , and the number of rings and double bonds, N DBE . Constitutional isomers are resolved on the basis of t R , enabling the most complete quantitative analysis to date of structural isomers in an environmentally relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. Lastly, the classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complete temperature profiles in ultra-high pressure liquid chromatography columns

The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C{sub 18} particles, average d{sub p} {approx} 1.7 {micro}m) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than {+-}0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

36 MATERIALS SCIENCE↗

Signatures of Biologically Driven Hemicellulose Modification Quantified by Analytical Pyrolysis Coupled with Multidimensional Gas Chromatography Mass Spectrometry

Biomass storage operation is one major source of feedstock quality variability that impacts on downstream preprocessing, feeding, handling and conversion into biofuels, chemicals and products. In field Ccorn stover biomass bales undergoes degradation and cell wall components modification resulting from microbial biological heating occurring during storage. A molecular characterization of the modification was achieved to unveil and understand the changes of structural cell wall modification in corn stover samples by conducting low temperature (400°C) pyrolysis, comparing samples that were mildly biologicallyun heated to those that had been subjected to microbial severe biological heating (~60°C). Pyrolysis of the samples originating from biomass that had been heated during storage generated small oxygenates such as furfural, 5-methylfurfural and 2-(5H)-furanone with efficiencies that were as much as ten times greater than those measured for the mildly unheated samples. Most of the compounds having enhanced efficiencies were C5 oxygenates, suggesting that the pyrolysis products may be formed from hemicellulosic precursor polymers in the corn stover. The findings suggest that microbial heating may be disrupting the cell wall structure, fragmenting the hemicellulose or cellulose chains, generating more polymer termini that have higher efficiency for generating the oxygenates at lower temperatures. Pyrolysis variability with temperature may be a beneficial strategy for improved biomass cell wall characterization, and for guiding control strategies for enhanced control over product distributions , providing insights to understand and manage the feedstock variability as well as to inform harvest and storage best management practices.

09 BIOMASS FUELS↗

Integration of Gas Chromatography Mass Spectrometry Methods for Differentiating Ricin Preparation Methods

The investigation of crimes involving chemical or biological agents is infrequent, but presents unique analytical challenges. The protein toxin ricin is encountered more frequently than other agents and is found in the seeds of the castor plant Ricinus communis. Typically, the toxin is extracted from castor seeds utilizing a variety of different recipes that result in varying purity of the toxin. Moreover, these various purification steps can also leave or differentially remove a variety of exogenous and endogenous residual components with the toxin that may indicate the type and number of purification steps involved. We have applied three gas chromatographic - mass spectrometric (GC-MS) based analytical methods to measure the variation in seed carbohydrates and castor oil ricinoleic acid as well as the presence of solvents used for purification. These methods were applied to the same samples prepared using four previously identified toxin preparation methods starting from four varieties of castor seeds. The individual data sets for seed carbohydrate profiles, ricinoleic acid or acetone amount each provided information capable of differentiating different types of toxin preparations across seed types. However, the integration of the data sets using multivariate factor analysis provided a clear distinction of all samples based on the preparation method and independent of the seed source. In particular the abundance of mannose, arabinose, fucose, ricinoleic acid and acetone were shown to be important differentiating factors. These complementary tools provide a more confident determination of the method of toxin preparation.

59 BASIC BIOLOGICAL SCIENCES↗

Explorations of TALSPEAK chemistry in extraction chromatography: Comparisons of TTHA with DTPA and HDEHP with HEH[EHP]

An advanced nuclear fuel cycle includes a reprocessing stage for the group separation of the lanthanides from the trivalent actinides. The TALSPEAK (Trivalent Actinide - Lanthanide Separation by Phosphorus reagent Extraction from Aqueous Komplexes) solvent extraction process provides the An3+/Ln3+ separation through the use of an organic lanthanide extractant (bis-2-ethyl(hexyl) phosphoric acid, HDEHP) and an aqueous actinide-selective holdback reagent (diethylenetriamine-N,N,N’,N’’,N’’-pentaacetic acid, DTPA). Organic phase interactions in TALSPEAK have proven sufficiently complex that, even with substantial research effort, a descriptive thermodynamic model has yet to be developed. If one were to consider an extraction chromatographic (EXC) version of TALSPEAK, the presence of concentrated extractant on the resin surface should augment the multifaceted organic phase chemistry. This study examines the previously unexplored impact of each aqueous phase TALSPEAK component (holdback reagent, carboxylic acid buffer, and pH) on the chemistry of the EXC system. The presence of alternative reagents, 2-ethyl(hexyl) phosphonic acid mono-2-ethyl(hexyl) ester acid (HEH[EHP]) and triethylenetetramine-N,N,N’,N’’,N’’’,N’’’-hexaacetic acid (TTHA) are also considered. Results indicate the concentrated extractant appears to enhance solid-phase reactions that most likely involve water, lactate and sodium. The presumed water, lactate and sodium partitioning consumes resin capacity sufficiently that the weaker hold-back reagent under TALSPEAK aqueous conditions (pH ~ 3.6), TTHA, provides preferential Am3+/Ln3+ separations performance. If a TALSPEAK-EXC process were to be developed, a resin with solvent diluted extractant or covalently bound functional groups may be preferential to reduce the complexity of the solid-phase chemistry.

actinide separation↗

The Coordination Chemistry and Stoichiometry of Extracted Diglycolamide Complexes of Lanthanides in Extraction Chromatography Materials

Industrial rare earth element (REE) separations predominantly utilize solvent extraction processes tailored toward conventional resources such as bastnäsite, monazite, and ion adsorption clays. Advances in diglycolamide (DGA) chemistry have shown effective extraction characteristics for REE separations. However, limitations associated with traditional DGA solvent extraction techniques, such as third-phase formation and gelling, have hindered commercial viability. By supporting DGA extractants on porous resins such as polystyrene divinyl benzene (PS-DVB), the desirable combination of solvent extraction selectivity and ease of operation of sorbent columns can be achieved. To design a low-cost model for such solid-supported DGAs, extraction characteristics as influenced by the underlying coordination chemistry must be explored to achieve efficient functional systems. Within this study, we report novel DGA resin materials, each incorporating one of the DGAs N,N,N’,N’-tetra-(1-octyl)-3-oxapentane-1,5-diamide (TODGA), N,N'-dimethyl-N,N'-dioctyl-3-oxapentane-1,5-diamide (DMDODGA), and 2,2'-oxybis(1-(3-(((2-ethylhexyl)thio)methyl)-4-methylpyrrolidin-1-yl)ethan-1-one) (DEHPDGA). The affinity of DGAs across the lanthanide (Ln) series was evaluated for both hydrochloric acid and nitric acid media with varying Ln feed concentrations to study distribution ratios and loading characteristics. Focusing on dysprosium, extended X-Ray Absorption Fine Structure (EXAFS) and density functional theory (DFT) calculations were also utilized to explore coordination chemistry and their effects on ligand performance. The general trend for both acid media resulted in DMDODGA having the highest extraction strength of all three DGAs at varying acid concentrations. Coordination-chemistry analysis supported by loading data, DFT calculations, and EXAFS results under forced loading conditions posited less than the expected 3:1 ligand-to-metal coordination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗