Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Experimental tests of an infrared video bolometer on Alcator C-Mod

A prototype of an infrared imaging bolometer (IRVB) was successfully tested on the Alcator C-Mod tokamak at the end of its 2016 campaign. The IRVB method interprets the power radiated from the plasma by measuring the temperature rise of a thin, ~2 μm, Pt absorber that is placed in the torus vacuum and exposed, using a pinhole camera, to the full-spectrum of plasma’s photon emission. The IRVB installed on C-Mod viewed the poloidal cross section of the core plasma and observed Ohmic and ion cyclotron range of frequency (ICRF)-heated plasmas. Analysis of total radiated power and on-axis emissivity from IRVB is summarized, and quantitative comparisons made to data from both resistive bolometers and AXUV diodes. IRVB results are clearly within a factor of two, but additional effort is needed for it to be used to fully support power exhaust research. The IRVB is shown to be immune to electromagnetic interference from ICRF which strongly impacts C-Mod’s resistive bolometers. Results of the bench-top calibration are summarized, including a novel temperature calibration method useful for IRVBs.

47 OTHER INSTRUMENTATION↗

DETECTION OF ROTATIONAL SPECTRAL VARIATION ON THE M-TYPE ASTEROID (16) PSYCHE

The asteroid (16) Psyche is of scientific interest because it contains ∼1% of the total mass of the asteroid belt and is thought to be the remnant metallic core of a protoplanet. Radar observations have indicated the significant presence of metal on the surface with a small percentage of silicates. Prior ground-based observations showed rotational variations in the near-infrared (NIR) spectra and radar albedo of this asteroid. However, no comprehensive study that combines multi-wavelength data has been conducted so far. Here we present rotationally resolved NIR spectra (0.7–2.5 μ m) of (16) Psyche obtained with the NASA Infrared Telescope Facility. These data have been combined with shape models of the asteroid for each rotation phase. Spectral band parameters extracted from the NIR spectra show that the pyroxene band center varies from ∼0.92 to 0.94 μ m. Band center values were used to calculate the pyroxene chemistry of the asteroid, whose average value was found to be Fs{sub 30}En{sub 65}Wo{sub 5}. Variations in the band depth (BD) were also observed, with values ranging from 1.0% to 1.5%. Using a new laboratory spectral calibration method, we estimated an average orthopyroxene content of 6% ± 1%. The mass-deficit region of Psyche, which exhibits the highest radar albedo, also shows the highest value for the spectral slope and the minimum BD. The spectral characteristics of Psyche suggest that its parent body did not have the typical structure expected for a differentiated body or that the sequence of events that led to its current state was more complex than previously thought.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration verification for stochastic agent-based disease spread models

Accurate disease spread modeling is crucial for identifying the severity of outbreaks and planning effective mitigation efforts. To be reliable when applied to new outbreaks, model calibration techniques must be robust. However, current methods frequently forgo calibration verification (a stand-alone process evaluating the calibration procedure) and instead use overall model validation (a process comparing calibrated model results to data) to check calibration processes, which may conceal errors in calibration. In this work, we develop a stochastic agent-based disease spread model to act as a testing environment as we test two calibration methods using simulation-based calibration, which is a synthetic data calibration verification method. The first calibration method is a Bayesian inference approach using an empirically-constructed likelihood and Markov chain Monte Carlo (MCMC) sampling, while the second method is a likelihood-free approach using approximate Bayesian computation (ABC). Simulation-based calibration suggests that there are challenges with the empirical likelihood calculation used in the first calibration method in this context. These issues are alleviated in the ABC approach. Despite these challenges, we note that the first calibration method performs well in a synthetic data model validation test similar to those common in disease spread modeling literature. We conclude that stand-alone calibration verification using synthetic data may benefit epidemiological researchers in identifying model calibration challenges that may be difficult to identify with other commonly used model validation techniques.

60 APPLIED LIFE SCIENCES↗

Isotopic exchange on solid-phase micro extraction fiber in sediment under stagnant conditions: Implications for field application of performance reference compound calibration

An overlooked issue for field application of in situ performance reference compound (PRC) calibration methods is the validity of the assumption that both the sorption of a target compound and desorption of its corresponding PRC follow the first-order kinetics with the same rate constants under stagnant conditions. In the present study, disposable polydimethylsiloxane fibers of 2 sizes (7 and 35 µm) impregnated with 8 13 C-labeled or deuterated PRCs were statically deployed into different marine sediments, from which the kinetics for sorption of the target compounds and desorption of the PRCs were characterized. Nonsymmetrical profiles were observed for exchange of the target analytes and their corresponding PRCs in sediment under stagnant conditions. Further, the hysteretic desorption of PRCs in the kinetic regime may be ascribed to the low chemical potential between the fiber and sediment porewater, which reflects the inability of water molecules to rapidly diffuse through sediment to solvate the PRCs in the aqueous layer around the fiber surface. A moderate correlation (r = 0.77 and r = 0.57, p < 0.05 for both regressions) between the PRC-calibrated equilibrium concentrations of 1,1-dichloro-2,2-bis-(chlorophenyl) ethylene (p,p'-DDE) and polychlorinated biphenyl (PCB)-153 and the lipid normalized levels in worms (Neanthes arenaceodentata) was obtained in co-exposure tests under simulating field conditions, probably resulting from slightly overestimated bioavailability because of the hysteretic desorption of PRCs and toxic effects. Environ Toxicol Chem 2016;35:1978–1985. © 2015 SETAC

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance

A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring method for neutron flux for a spallation target in an accelerator driven sub-critical system

Here in this paper, we study a monitoring method for neutron flux for the spallation target used in an accelerator driven sub-critical (ADS) system, where a spallation target located vertically at the centre of a sub-critical core is bombarded vertically by high-energy protons from an accelerator. First, by considering the characteristics in the spatial variation of neutron flux from the spallation target, we propose a multi-point measurement technique, i.e. the spallation neutron flux should be measured at multiple vertical locations. To explain why the flux should be measured at multiple locations, we have studied neutron production from a tungsten target bombarded by a 250 MeV-proton beam with Geant4-based Monte Carlo simulations. The simulation results indicate that the neutron flux at the central location is up to three orders of magnitude higher than the flux at lower locations. Secondly, we have developed an effective technique in order to measure the spallation neutron flux with a fission chamber (FC), by establishing the relation between the fission rate measured by FC and the spallation neutron flux. Since this relation is linear for a FC, a constant calibration factor is used to derive the neutron flux from the measured fission rate. This calibration factor can be extracted from the energy spectra of spallation neutrons. Finally, we have evaluated the proposed calibration method for a FC in the environment of an ADS system. The results indicate that the proposed method functions very well.

43 PARTICLE ACCELERATORS↗

SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specific geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.

60 APPLIED LIFE SCIENCES↗

Determination of Main Components of Glass-Forming Cu–Zr Alloys

A rapid procedure is developed for determination of copper and zirconium in their binary alloys Cu{sub 100–x}Zr{sub x} in the content ranges corresponding to the region of bulk amorphization (x = 30–70) using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The spectrometer operating conditions are optimized, and the analytical spectral lines (Cu II 224.700 nm and Zr II 354.262 nm) are selected, as well as calibration method and sampling procedure: dissolution in the mixture of HNO{sub 3} and HF with addition of HCl, providing for the minimum standard deviation of the analytical signal. A procedure of oxygen determination by inert gas fusion technique and a procedure for determination of copper by spectrophotometry and zirconium by gravimetric analysis in a single sample together with quality control of ICP-AES are developed for the considered alloys. The results of analysis of Cu{sub 100–x}Zr{sub x} alloys according to the developed procedures agree well between themselves and accounting for adjustment of oxygen content agree within the error limits (not more than 0.5 wt %) with the added content of copper and zirconium upon synthesis.

36 MATERIALS SCIENCE↗

Controllable 3D Manufacturing System

Next generation Small Modular Reactor (SMR) requires new and improved techniques, instrumentations and strategies to deal with the anticipated high radiation and high temperature environment (esp. in reactors). Component manufacturing technologies will be required that take full advantage of the new 3-D printing methods employed by additive manufacturing technologies. These manufacturing methods must be capable of producing components or sub components on a limited production basis and with nuclear quality. Based on our success in developing a variety of award-winning high energy and high power ultrafast fiber lasers and our pioneered work in fs laser 3D manufacturing (US patents, 9643361 and 9770760), PolarOnyx proposes to use tunable fiber lasers to develop smart AM & SM system to make nuclear quality components for SMR. In Phase I, we have achieved critical milestones and experimentally demonstrated the most critical functions of the proposed controllable laser AM: • Developed and investigated a series of NDI sensing technologies. Combination of IR thermal image and high resolution visible camera provides a powerful tool to characterize thermal distribution and defects. • Built an in-line laser induced breakdown spectroscopy (LIBS) to real time detect compositions of powder and parts, and melting temperature of the melting pool. It proves the LIBS is a very powerful tool to precisely guide the process. • Filed a patent (Application number 16378485) for integrating IR and visible images and LIBS for intelligent AM system. • Developed control algorithm and proved it works well for overhang experiment. • Achieved high density (>99%) and excellent mechanical properties. • Succeeded in developing a working and reliable calibration method to extract true temperature distribution during AM process. • Demonstrated spatial and temporal pulse shaping methods, and impact on microstructures. • Filed one utility patent • Laid out a solid path for phase II to work on controllable 3D manufacturing system development and optimization and to make components with nuclear quality. Our proprietary fs fiber laser based AM processing offers an ultimate solution for manufacturing high temperature components with high strength for nuclear systems. The 3D AM system in conjunction with the intelligent sensing and control is energy efficient and cost effective for the growing nuclear industries. Successful development of the proposed AM technology will provide a vital tool to solve existing and potential issues. This technology will be directly applied in the 3D printing area with combined market share of $10(s) of billions. The achievement in this research will have significant and wide social, scientific, and economic impacts by providing affordable low cost intelligent AM/SM systems, laser micromachining systems, improving energy efficiency, and reducing fabrication and operational cost. Having demonstrated the proof of concept in Phase I, we will prototype the controllable AM/SM system and investigate the efficiency and qualification of fabricating various nuclear quality components in Phase II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward Improved Regional Hydrological Model Performance Using State-Of-The-Science Data-Informed Soil Parameters

Accurate soil moisture and streamflow data are an aspirational need of many hydrologically relevant fields. Model simulated soil moisture and streamflow hold promise but models require validation prior to application. Calibration methods are commonly used to improve model fidelity but misrepresentation of the true dynamics remains a challenge. In this study, we leverage soil parameter estimates from the Soil Survey Geographic (SSURGO) database and the probability mapping of SSURGO (POLARIS) to improve the representation of hydrologic processes in the Weather Research and Forecasting Hydrological modeling system (WRF-Hydro) over a central California domain. Our results show WRF-Hydro soil moisture exhibits increased correlation coefficients ( r ), reduced biases, and increased Kling-Gupta Efficiencies (KGEs) across seven in situ soil moisture observing stations after updating the model's soil parameters according to POLARIS. Compared to four well-established soil moisture data sets including Soil Moisture Active Passive data and three Phase 2 North American Land Data Assimilation System land surface models, our POLARIS-adjusted WRF-Hydro simulations produce the highest mean KGE (0.69) across the seven stations. More importantly, WRF-Hydro streamflow fidelity also increases, especially in the case where the model domain is set up with SSURGO-informed total soil thickness. The magnitude and timing of peak flow events are better captured, r increases across nine United States Geological Survey stream gages, and the mean KGE across seven of the nine gages increases from 0.12 to 0.66. Our pre-calibration parameter estimate approach, which is transferable to other spatially distributed hydrological models, can substantially improve a model's performance, helping reduce calibration efforts and computational costs.

54 ENVIRONMENTAL SCIENCES↗

Comparison of CERES-MODIS Stratus Cloud Properties with Ground-Based Measurements at the DOE ARM Southern Great Plains Site

Overcast stratus cloud properties derived for the Clouds and the Earth's Radiant Energy system (CERES) Project using Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data are compared with observations taken at the Atmospheric Radiation Measurement (ARM) Southern Great Plains site from March 2000 through December 2004. Retrievals from ARM surface-based data were averaged over a 1-hour interval centered at the time of each satellite overpass, and the CERES-MODIS cloud properties were averaged within a 30-km x 30 km box centered on the ARM SGP site. Two datasets were analyzed: all of the data (ALL) which include multilayered, single-layered, and slightly broken stratus decks and a subset, single-layered unbroken decks (SL). The CERES-MODIS effective cloud heights were determined from effective cloud temperature using a lapse rate method with the surface temperature specified as the 24-h mean surface air temperature. For SL stratus, they are, on average, within the ARM radar-lidar estimated cloud boundaries and are 0.534 +/- 0.542 km and 0.108 +/- 0.480 km lower than the cloud physical tops and centers, respectively, and are comparable for day and night observations. The mean differences and standard deviations are slightly larger for ALL data, but not statistically different to those of SL data. The MODIS-derived effective cloud temperatures are 2.7 +/- 2.4 K less than the surface-observed SL cloud center temperatures with very high correlations (0.86-0.97). Variations in the height differences are mainly caused by uncertainties in the surface air temperatures, lapse rates, and cloud-top height variability. The biases are mainly the result of the differences between effective and physical cloud top, which are governed by cloud liquid water content and viewing zenith angle, and the selected lapse rate, -7.1 K km(exp -1). Based on a total of 43 samples, the means and standard deviations of the differences between the daytime Terra and surface retrievals of effective radius r(sub e), optical depth, and liquid water path for SL stratu are 0.1 +/- 1.9 micrometers (1.2 +/- 23.5%), -1.3 +/- 9.5 (-3.6 +/-26.2%), and 0.6 +/- 49.9 gm (exp -2) (0.3 +/- 27%), respectively, while the corresponding correlation coefficients are 0.44, 0.87, and 0.89. For Aqua, they are 0.2 +/- 1.9 micrometers (2.5 +/- 23.4%), 2.5 +/- 7.8 (7.8 +/- 24.3%), and 28.1 +/- 52.7 gm (exp -2) (17.2 +/- 32.2%), as well as 0.35, 0.96, and 0.93 from a total of 21 cases. The results for ALL cases are comparable. Although a bias in R(sub e) was expected because the satellite retrieval of effective radius only represents the top of the cloud, the surface-based radar retrievals revealed that the vertical profile of r(sub e) is highly variable with smaller droplets occurring at cloud top in some cases. The larger bias in optical depth and liquid water path for Aqua is due, at least partially, to differences in the Terra and Aqua MODIS visible channel calibrations. methods for improving the cloud-top height and microphysical property retrievals are suggested.

Dong, Xiquan↗

MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

60 APPLIED LIFE SCIENCES↗

Complex Sources and Impacts on Remediation and Monitoring Approaches - 19058

Remedy selection, implementation, and coordination with tank farm activities for adjacent waste sites need to be facilitated by a technically defensible description of sources and their relative strength and temporal contributions to groundwater contamination. Detailed data describing contaminant source releases are typically not available, so source locations are highly uncertain. Furthermore, data on sources and model parameters are not readily available through direct measurements. Instead, source data are often derived by extrapolation from a few direct and/or indirect measurements, while model parameters are commonly estimated using inverse modeling or calibration methods. Because the conceptual model of sources will influence the mass and timing of the flux of contaminants to groundwater, uncertainty in the source terms should be considered. Even though a best-fit model can often be identified, it may not be the best representation of the sources given the sparse, uncertain nature of the data used for estimating source terms. To support future feasibility studies, a systematic approach is needed for identifying remediation and monitoring activities appropriate under conditions of uncertainty. In this study, an integrated assessment of alternative conceptual model elements has been examined using the B-Complex site in the Hanford Central Plateau to demonstrate how multiple sources in a waste management complex can be described to identify their relative contributions to groundwater. The heterogeneous structure of the system is modeled based on available field information on the lithological data for both the vadose zone and aquifer. The approach includes a simulation assessment and linkages to site data, with an uncertainty analysis applied to evaluate the effects of source term uncertainty on contaminant mass flux to groundwater. An integrated assessment of alternative conceptual model elements was evaluated to identify how parameter uncertainty impacts both temporal and spatial uncertainties associated with vadose zone source terms. Modeling scenarios identify important characteristics of remediation target zones to provide context for how surface barriers, in situ remedies, and water-table treatment zones can be designed to account for source dynamics. Ramifications for remediation and monitoring are discussed within the context of the source term uncertainty. The described approach facilitates systematically addressing alternative conceptual model questions in relation to remediation and monitoring and supports the remedial investigation/ feasibility study process and the remediation strategy development for the Hanford Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Lightning radiometry in visible and infrared bands

Calibrated measurements of lightning optical emissions are critical for both quantifying the impacts of lightning in our atmosphere and devising detection instruments with sufficient dynamic range capable of yielding close to 100% detection efficiency. However, to date, there is only a limited number of investigations that have attempted to take such calibrated measurements. Here, in this work, we report the power radiated by lightning in both visible and infrared bands, assuming isotropic emission, and accounting for atmospheric absorption. More precisely, we report peak radiated power and total radiated energy in the combined visible plus near-infrared range (VNIR, 0.34–1.1 μm), around the H α line (652–667 nm), and for the 2–2.5 μm infrared band. The estimated peak power and total energy radiated by negative cloud-to-ground return strokes in the VNIR range is 130 MW and 20 kJ, respectively. Additionally, we detected peak radiated powers of 12 and 0.19 MW in the H α and infrared bands, respectively. We cross-reference the optical data set with peak current reported by a lightning detection network. The resulting trend is that optical power emitted around the H α line scales with peak return stroke current according to a power law with exponent equal to 1.25. This trend, which should be approximately true across the entire visible spectrum, can be attributed to the plasma negative differential resistance of the lightning return stroke channel. We conclude by discussing the challenges in performing calibrated measurements of lightning optical power in different bands and comparing the results with previously-collected data with different experimental setups, observation conditions, and calibration methods.

54 ENVIRONMENTAL SCIENCES↗

A predictive discrete-continuum multiscale model of plasticity with quantified uncertainty

Multiscale models of materials, consisting of upscaling discrete simulations to continuum models, are unique in their capability to simulate complex materials behavior. The fundamental limitation in multiscale models is the presence of uncertainty in the computational predictions delivered by them. In this work, a sequential multiscale model has been developed, incorporating discrete dislocation dynamics (DDD) simulations and a strain gradient plasticity (SGP) model to predict the size effect in plastic deformations of metallic micro-pillars. The DDD simulations include uniaxial compression of micro-pillars with different sizes and over a wide range of initial dislocation densities and spatial distributions of dislocations. An SGP model is employed at the continuum level that accounts for the size-dependency of flow stress and hardening rate. Sequences of uncertainty analyses have been performed to assess the predictive capability of the multiscale model. The variance-based global sensitivity analysis determines the effect of parameter uncertainty on the SGP model prediction. The multiscale model is then constructed by calibrating the continuum model using the data furnished by the DDD simulations. A Bayesian calibration method is implemented to quantify the uncertainty due to microstructural randomness in discrete dislocation simulations (density and spatial distribution of dislocations) on the macroscopic continuum model prediction (size effect in plastic deformation). Here, the outcomes of this study indicate that the discrete-continuum multiscale model can accurately simulate the plastic deformation of micro-pillars, despite the significant uncertainty in the DDD results. Additionally, depending on the macroscopic features represented by the DDD simulations, the SGP model can reliably predict the size effect in plasticity responses of the micropillars with below 10% of error.

36 MATERIALS SCIENCE↗

A radial time projection chamber for α detection in CLAS at JLab

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils to measure exclusive nuclear reactions, such as coherent deeply virtual Compton scattering and coherent meson production off 4 He. In 2009, we carried out these measurements using the CEBAF Large Acceptance Spectrometer (CLAS) supplemented by the RTPC positioned directly around a gaseous 4 He target, allowing a detection threshold as low as 12 MeV for 4 He. This work discusses the design, principle of operation, calibration methods and performances of this RTPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗