Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Ground far-red sun-induced chlorophyll fluorescence and vegetation indices in the US Midwestern agroecosystems

Abstract Sun-induced chlorophyll fluorescence (SIF) provides an opportunity to study terrestrial ecosystem photosynthesis dynamics. However, the current coarse spatiotemporal satellite SIF products are challenging for mechanistic interpretations of SIF signals. Long-term ground SIF and vegetation indices (VIs) are important for satellite SIF validation and mechanistic understanding of the relationship between SIF and photosynthesis when combined with leaf- and canopy-level auxiliary measurements. In this study, we present and analyze a total of 15 site-years of ground far-red SIF (SIF at 760 nm, SIF 760 ) and VIs datasets from soybean, corn, and miscanthus grown in the U.S. Corn Belt from 2016 to 2021. We introduce a comprehensive data processing protocol, including different retrieval methods, calibration coefficient adjustment, and nadir SIF footprint upscaling to match the eddy covariance footprint. This long-term ground far-red SIF and VIs dataset provides important and first-hand data for far-red SIF interpretation and understanding the mechanistic relationship between far-red SIF and canopy photosynthesis across various crop species and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Quantitative Analysis of Ion Mobility Spectrometry by Chemometric Multivariate Calibration

Traditional peak-area calibration and the multivariate calibration methods of principle component regression (PCR) and partial least squares (PLS), including unfolded PLS (U-PLS) and multi-way PLS (N-PLS), were evaluated for the quantification of 2,4,6-trinitrotoluene (TNT) and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) in Composition B samples analyzed by temperature step desorption ion mobility spectrometry (TSD-IMS). The true TNT and RDX concentrations of eight Composition B samples were determined by high performance liquid chromatography with UV absorbance detection. Most of the Composition B samples were found to have distinct TNT and RDX concentrations. Applying PCR and PLS on the exact same IMS spectra used for the peak-area study improved quantitative accuracy and precision approximately 3 to 5 fold and 2 to 4 fold, respectively. This in turn improved the probability of correctly identifying Composition B samples based upon the estimated RDX and TNT concentrations from 11% with peak area to 44% and 89% with PLS. This improvement increases the potential of obtaining forensic information from IMS analyzers by providing some ability to differentiate or match Composition B samples based on their TNT and RDX concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

J-PLUS: Systematic impact of metallicity on photometric calibration with the stellar locus

Here, we present the photometric calibration of the twelve optical passbands for the Javalambre Photometric Local Universe Survey (J-PLUS) second data release (DR2), comprising 1088 pointings of two square degrees, and study the systematic impact of metallicity on the stellar locus technique. The [Fe/H] metallicity from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) for 146 184 high-quality calibration stars, defined with signal-to-noise ratio larger than ten in J-PLUS passbands and larger than three in Gaia parallax, was used to compute the metallicity-dependent stellar locus (ZSL). The initial homogenization of J-PLUS photometry, performed with a unique stellar locus, was refined by including the metallicity effect in colors via the ZSL. The variation of the average metallicity along the Milky Way produces a systematic offset in J-PLUS calibration. This effect is well above 1% for the bluer passbands and amounts 0.07, 0.07, 0.05, 0.03, and 0.02 mag in u, J0378, J0395, J0410, and J0430, respectively. We modeled this effect with the Milky Way location of the J-PLUS pointing, also providing an updated calibration for those observations without LAMOST information. The estimated accuracy in the calibration after including the metallicity effect is at 1% for the bluer J-PLUS passbands and below for the rest. Photometric calibration with the stellar locus technique is prone to significant systematic bias in the Milky Way for passbands bluer than λ = 4500 Å. The calibration method for J-PLUS DR2 reaches 1–2% precision and 1% accuracy for 12 optical filters within an area of 2176 square degrees.

79 ASTRONOMY AND ASTROPHYSICS↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Automated Approach for Construction of Long-Term, Data-Intensive Watershed Models

Watershed models such as the Hydrological Simulation Program in FORTRAN (HSPF) are frequently used to analyze large-scale water quantity and water quality issues. The construction of HSPF models is a difficult and time-consuming process, because it requires compilation of extensive quantities of data into formatted files followed by a simultaneous fitting of many uncertain parameters. Because of these complications, studies are often limited to calibration periods of only a few years even when analyzing long time-scale issues such as climate and land-use changes that are difficult or impossible to reproduce. High-level, open source programming languages provide an environment for automating the extraction and processing of various sources of data in addition to the calibration process required by HSPF. Recently developed software can be used to build HSPF input files, run simulations, and postprocess simulation results using the Python programming language. The combination of tools in Python, public data sets on the Internet, and software extensions enables rapid development of long-term, reproducible, and sophisticated models for new hydrologic insight. Herein, the utility of these tools is illustrated by developing an automated 30-year HSPF model with a Nash-Sutcliffe efficiency of 0.88 for monthly flows and 0.75 for daily flows in a simulation time of approximately 3h. The integration of HSPF with a high-level programming language creates opportunities to more rigorously explore model assumptions, calibration methods, and alternative data sets.

Lampert, Dave J↗

Characterization of energetic and thermalized sputtered atoms in pulsed plasma using time-resolved tunable diode-laser induced fluorescence

In this work, a time-resolved tunable diode-laser (DL) induced fluorescence (TR-TDLIF) method calibrated by absorption spectroscopy has been developed in order to determine atom and flux velocity distribution functions (AVDF and FVDF) of the energetic and the thermalized atoms in pulsed plasmas. The experimental set-up includes a low-frequency (∼3 Hz) and high spectral-resolution DL (∼0.005 pm), a fast rise-time pulse generator, and a high power impulse magnetron sputtering (HiPIMS) system. The induced TR-TDLIF signal is recorded every 0.5 μs with a digital oscilloscope of a second-long trace. The technique is illustrated with determining the AVDF and the FVDF of a metastable state of the sputtered neutral tungsten atoms in the HiPIMS post-discharge. Gaussian functions describing the population of the four W isotopes were used to fit the measured TR-TDLIF signal. These distribution functions provide insight into transition from the energetic to thermalized regimes from the discharge onset. This technique may be extended with appropriate DLs to probe any species with rapidly changing AVDF and FVDF in pulsed and strongly oscillating plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. Lastly, this method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric field dependence of nanoscale cathodoluminescence inside Cr doped β-Ga 2 O 3 interfaces

Chromium (Cr) is a common impurity in β-Ga 2 O 3 crystals, where its characteristic R1 and R2 luminescence lines are susceptible to both the host crystal field and externally applied fields. Here, in this work, we demonstrate that the Cr cathodoluminescence (CL) quenches toward the bulk of the crystal but enhances with applied reverse bias, reflecting the effect of free carrier depletion with increasing electric field. Furthermore, we illustrate that the R1/R2 CL intensity ratio, measured as the integrated area ratio of R1 to R2, can be used as a direct probe of the electric field in a Ni-β-Ga 2 O 3 : Cr Schottky diode. This optical calibration method provides a complementary approach to conventional C–V and I–V measurements for determining electric field strength in the depletion region of β-Ga 2 O 3 -based Schottky diodes and can be extended to other semiconductors and multilayer device structures.

36 MATERIALS SCIENCE↗

REIONIZATION ON LARGE SCALES. III. PREDICTIONS FOR LOW-l COSMIC MICROWAVE BACKGROUND POLARIZATION AND HIGH-l KINETIC SUNYAEV-ZEL'DOVICH OBSERVABLES

We present new predictions for cosmic microwave background (CMB) temperature (on small angular scales) and polarization (on large angular scales) anisotropies induced during the epoch of reionization (EoR). Using a novel method calibrated from radiation-hydrodynamic simulations, we model the EoR in large volumes (L ∼> 2 Gpc h {sup –1}). We find that the EoR contribution to the kinetic Sunyaev-Zel'dovich power spectrum (patchy kSZ) ranges between ∼0.6-2.8 μK{sup 2} at l = 3000 for the explored parameter space. For each model, the patchy kSZ power spectrum is calculated from three large 15° × 15° maps for better numerical convergence. Decreasing the size of these maps biases the overall patchy kSZ power to higher values. We find that the amplitude of the patchy kSZ power spectrum at l = 3000 follows simple scalings of D{sub l=3000}{sup kSZ}∝ z-bar and D{sub l=3000}{sup kSZ}∝Δ{sub z}{sup 0.51} for the mean redshift ( z-bar ) and duration (Δ{sub z}) of reionization. Using the constraints on z-bar from the Wilkinson Microwave Anisotropy Probe seven year results and the lower limit on Δ{sub z} from EDGES, we find a lower limit of ∼0.4 μK{sup 2} at l = 3000. Planck will infer the mean redshift from the Thomson optical depth imprinted in the low-l polarization power spectrum. Future measurements of the high-l CMB power spectrum from the Atacama Cosmology Telescope and South Pole Telescope should detect the patchy kSZ signal if the cross correlation between the thermal SZ effect and the cosmic infrared background is constrained. We show that the combination of temperature and polarization measurements constrains both z-bar and Δ{sub z}. The patchy kSZ maps, power spectra templates, and the polarization power spectra will be publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Reionization on large scales. IV. Predictions for the 21 cm signal incorporating the light cone effect

We present predictions for the 21 cm brightness temperature power spectrum during the Epoch of Reionization (EoR). We discuss the implications of the 'light cone' effect, which incorporates evolution of the neutral hydrogen fraction and 21 cm brightness temperature along the line of sight. Using a novel method calibrated against radiation-hydrodynamic simulations, we model the neutral hydrogen density field and 21 cm signal in large volumes (L = 2 Gpc h {sup –1}). The inclusion of the light cone effect leads to a relative decrease of about 50% in the 21 cm power spectrum on all scales. We also find that the effect is more prominent at the midpoint of reionization and later. The light cone effect can also introduce an anisotropy along the line of sight. By decomposing the 3D power spectrum into components perpendicular to and along the line of sight, we find that in our fiducial reionization model, there is no significant anisotropy. However, parallel modes can contribute up to 40% more power for shorter reionization scenarios. The scales on which the light cone effect is relevant are comparable to scales where one measures the baryon acoustic oscillation. We argue that due to its large comoving scale and introduction of anisotropy, the light cone effect is important when considering redshift space distortions and future application to the Alcock-Paczyński test for the determination of cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

The apogee red-clump catalog: Precise distances, velocities, and high-resolution elemental abundances over a large area of the Milky Way's disk

The Sloan Digital Sky Survey III's Apache Point Observatory Galactic Evolution Experiment (APOGEE) is a high-resolution near-infrared spectroscopic survey covering all of the major components of the Galaxy, including the dust-obscured regions of the inner Milky Way disk and bulge. Here we present a sample of 10,341 likely red-clump stars (RC) from the first two years of APOGEE operations, selected based on their position in color-metallicity-surface-gravity-effective-temperature space using a new method calibrated using stellar evolution models and high-quality asteroseismology data. The narrowness of the RC locus in color-metallicity-luminosity space allows us to assign distances to the stars with an accuracy of 5%-10%. The sample extends to typical distances of about 3 kpc from the Sun, with some stars out to 8 kpc, and spans a volume of approximately 100 kpc{sup 3} over 5 kpc ≲ R ≲ 14 kpc, |Z| ≲ 2 kpc, and –15° ≲ Galactocentric azimuth ≲ 30°. The APOGEE red-clump (APOGEE-RC) catalog contains photometry from the Two Micron All Sky Survey, reddening estimates, distances, line-of-sight velocities, stellar parameters and elemental abundances determined from the high-resolution APOGEE spectra, and matches to major proper motion catalogs. We determine the survey selection function for this data set and discuss how the RC selection samples the underlying stellar populations. We use this sample to limit any azimuthal variations in the median metallicity within the ≈45° azimuthal region covered by the current sample to be ≤0.02 dex, which is more than an order of magnitude smaller than the radial metallicity gradient. This result constrains coherent non-axisymmetric flows within a few kiloparsecs from the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

How to constrain your M dwarf: Measuring effective temperature, bolometric luminosity, mass, and radius

Precise and accurate parameters for late-type (late K and M) dwarf stars are important for characterization of any orbiting planets, but such determinations have been hampered by these stars’ complex spectra and dissimilarity to the Sun. We exploit an empirically calibrated method to estimate spectroscopic effective temperature (T{sub eff}) and the Stefan–Boltzmann law to determine radii of 183 nearby K7–M7 single stars with a precision of 2%–5%. Our improved stellar parameters enable us to develop model-independent relations between T{sub eff} or absolute magnitude and radius, as well as between color and T{sub eff}. The derived T{sub eff}–radius relation depends strongly on [Fe/H], as predicted by theory. The relation between absolute K{sub S} magnitude and radius can predict radii accurate to ≃3%. We derive bolometric corrections to the VR{sub C}I{sub C}grizJHK{sub S} and Gaia passbands as a function of color, accurate to 1%–3%. We confront the reliability of predictions from Dartmouth stellar evolution models using a Markov chain Monte Carlo to find the values of unobservable model parameters (mass, age) that best reproduce the observed effective temperature and bolometric flux while satisfying constraints on distance and metallicity as Bayesian priors. With the inferred masses we derive a semi-empirical mass–absolute magnitude relation with a scatter of 2% in mass. The best-agreement models overpredict stellar T{sub eff} values by an average of 2.2% and underpredict stellar radii by 4.6%, similar to differences with values from low-mass eclipsing binaries. These differences are not correlated with metallicity, mass, or indicators of activity, suggesting issues with the underlying model assumptions, e.g., opacities or convective mixing length.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPROVED Ti II log(gf) VALUES AND ABUNDANCE DETERMINATIONS IN THE PHOTOSPHERES OF THE SUN AND METAL-POOR STAR HD 84937

Atomic transition probability measurements for 364 lines of Ti II in the UV through near-IR are reported. Branching fractions from data recorded using a Fourier transform spectrometer (FTS) and a new echelle spectrometer are combined with published radiative lifetimes to determine these transition probabilities. The new results are in generally good agreement with previously reported FTS measurements. Use of the new echelle spectrometer, independent radiometric calibration methods, and independent data analysis routines enables a reduction of systematic errors and overall improvement in transition probability accuracy over previous measurements. The new Ti II data are applied to high-resolution visible and UV spectra of the Sun and metal-poor star HD 84937 to derive new, more accurate Ti abundances. Lines covering a range of wavelength and excitation potential are used to search for non-LTE effects. The Ti abundances derived using Ti II for these two stars match those derived using Ti I and support the relative Ti/Fe abundance ratio versus metallicity seen in previous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Hierarchical top-down bottom-up calibration with consideration for uncertainty and inter-scale discrepancy of Peierls stress of bcc Fe

A hierarchical multiscale model of plasticity in single crystal bcc Fe, framed at the mesoscale pertaining to a statistically representative set of dislocations for each slip system, relies on specification of a set of parameters which are informed using both bottom-up (BU) (atomistic) and top-down (TD) (experimental) information. We term this specification process a 'connection' between BU and TD pathways to inform the mesoscale model. The connection is considered in the presence of error, uncertainty, and discrepancy between the models. Furthermore, we expand upon a previously developed reconciled TD and BU calibration method to account for anticipated discrepancy between information from different length scales. The results of a previously formulated likelihood-based connection test of the multiscale model suggest a 'missing link' may be responsible for part of the inter-scale discrepancy. In this case, this link is assumed to be a relation between the unit-process (single dislocation line) of coordinated kink-pair nucleation on a screw dislocation segment and the many-body dislocation process which manifests in the onset of experimentally observed plastic deformation in a single crystal. A physics-informed discrepancy layer is formulated to improve the connection in the presence of additional persistent uncertainties. This physics-informed hypothesis testing is demonstrated as an alternative to fully data-driven search methods, particularly applicable to datasets of limited size that are often encountered in such multiscale material modeling applications. Discrete dislocation dynamics simulations are used to investigate the effect of the Peierls stress on straight screw dislocations and in the operation of Frank–Read sources. Discussion concerns the critical role of uncertainty quantification in providing a basis for this form of incremental hypothesis testing.

42 ENGINEERING↗

Coherent microwave scattering from resonance enhanced multi-photon ionization (Radar REMPI): A review

Coherent microwave scattering from laser-induced plasmas, including weakly ionized plasma, laser sparks, Multiphoton Ionization (MPI), and Resonance Enhanced Multi-Photon Ionizations (Radar REMPI) has achieved much successes in plasma, reactive and nonreactive flow diagnostics. Under illumination of microwaves (Radar), electrons inside the laser-induced plasma oscillate with the electric field of the microwave and re-radiate from the electrons forming coherent scattering. In the far-field approximation, the microwave scattering from the small volume plasma reflects the generation and evolution of unbounded electrons inside the plasma, when the microwave wavelength is much greater than the size of the plasma and the skin layer depth at the microwave frequency is larger than the size of the plasma. Laser excitation schemes, microwave detection methods, calibration of microwave scattering, and the novel applications of the technique have been significantly expanded and improved. Furthermore, this review paper summarizes physical principles, various REMPI excitation schemes for atomic and molecular species, and temperature measurements in plasma and reactive flows. Discussions on new research directions and applications are given at the end.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗