Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Role of Polymer Architecture in CO 2 Capture from Air Using Supported Poly(alkylenimine)s: Linear vs Branched Polymers

Direct air capture (DAC) of CO 2 coupled with geologic storage is a promising climate change mitigation strategy, with some applications employing amines supported on porous solids as CO 2 sorbents. While branched poly(ethylenimine) (PEI) is the standard benchmark amine material, it suffers from limited oxidative stability. Poly(propylenimine) (PPI), as an alternative, has previously demonstrated improved resistance to degradation under harsh oxidative conditions. Linear and branched PEI are commercially available, though at different molecular weights, while PPI is not commercially available. For this reason, a comparative study of all four polymers (linear PEI, branched PEI, linear PPI, branched PPI) has not been reported for DAC. In this study, we synthesize and compare low-molecular-weight (∼800 g/mol) linear (L) and branched (B) PEI and PPI supported on a model support, SBA-15 silica. These materials are evaluated for CO 2 adsorption under dry, DAC-relevant conditions (400 ppm of CO 2 , 30 °C). LPPI exhibited the highest amine efficiency at all loadings, reaching a maximum of 0.14 mmol CO 2 /mmol N, outperforming BPEI, while LPEI consistently showed the lowest uptake capacity. Temperature-programmed desorption reveals that the structure of the amine polymer impacts the CO 2 binding strength, with branched polymers displaying higher desorption energies of 102−111 kJ/mol. In situ infrared spectroscopy experiments show that all sorbents preferentially capture CO 2 as ammonium carbamate. Isobaric CO 2 uptake studies further underscore the influence of polymer mobility and support pore crowding on performance, while demonstrating the sorbents’ performance at elevated temperatures and CO 2 concentrations. All materials demonstrated good stability over 25 adsorption−desorption cycles using thermal regeneration in an inert gas purge, with only BPPI displaying a 10−11% decrease in capacity/amine efficiency during cycling, possibly due to the loss of low molecular weight, oligomeric amines. This is the first side-by-side comparison of the CO 2 sorption properties of linear and branched PEI and PPI with similar molecular weights. These findings highlight the significant role of polymer architecture in CO 2 capture efficiency and inform future designs of durable, high-performance DAC sorbents.

adsorbents↗

The effectiveness of TRIS and ammonium buffers in glass dissolution studies: a comparative analysis

Abstract Selecting appropriate buffers is crucial for evaluating the chemical durability of glass under controlled conditions such as in the EPA 1313 test designed to measure elemental release as a function of pH. The efficacy of two alkali-metal free buffers, TRIS (NH 2 C(CH 2 OH) 3 ) and ammonium chloride—ammonia (NH 3 /NH 4 Cl), was investigated during EPA 1313 testing of a simulated Hanford low-activity waste borosilicate glass in the alkaline regime (pH 8.5–10.5) at varying temperatures (RT, 40 °C, and 60 °C). While both buffers maintained the desired pH at room temperature, and up to 40 °C, the effectiveness of TRIS decreased at elevated temperatures, particularly at pH 10.5. Although 11 B NMR showed evidence of TRIS-B complexation, its effect on the rate of elemental release was found to be negligible under the test conditions. With ammonium buffer, the release of alkali cations was slightly elevated when compared to the same conditions with TRIS at early time points.

36 MATERIALS SCIENCE↗

Comparative S/TEM study of superconducting Ta quantum resonators by wet and dry etching types

Superconducting resonators play a pivotal role in various quantum technology applications, such as quantum computing and high-frequency communication systems. The performance of these resonators is closely tied to the properties of the superconducting films used in their fabrication. Here, in this study, we investigated the impact of wet and dry etching on tantalum (Ta) films leveraging advanced scanning transmission electron microscopy-based characterization methods and examined the morphological, chemical, and strain changes caused by the etching processes. Consequently, we report the significant differences between the two etching methods, with dry etching resulting in straight slanted sidewalls and a thinner oxidized layer, while wet etching produced curved sidewalls and undercuts. Both methods led to the formation of a residual Ta wedge at the lower part of the sidewall, causing lattice deformation, which could adversely influence the homogeneous operations of superconducting devices. These insights enhance our understanding of how etching influences superconducting films, offering valuable guidance for optimizing resonators and related devices. Our findings mark a significant stride in advancing quantum technologies and high-frequency communication by enhancing our practical understanding of superconducting material fabrication.

36 MATERIALS SCIENCE↗

Vortex motion induced losses in tantalum resonators

Tantalum (Ta)-based superconducting circuits have been demonstrated to enable ultrahigh qubit quality factors (𝑄), motivating a careful study of the microscopic origin of the remaining losses that limit their performance. We have recently shown that the losses in Ta-based resonators are dominated by two-level systems at low microwave powers and millikelvin temperatures. We also observe that some devices exhibit loss that is exponentially activated at a lower temperature inconsistent with the superconducting critical temperature (T 𝑐 ) of the constituent film. Specifically, dc resistivity measurements show a T 𝑐 of over 4 K, while microwave measurements of resonators fabricated from these films show losses that increase exponentially with temperature with an activation energy as low as 0.3 K. Here, in this study, we present a comparative study of the structural and thermodynamic properties of Ta-based resonators and identify vortex motion-induced loss as the source of thermally activated microwave loss. Through careful magnetoresistance and x-ray diffraction measurements, we observe that the increased loss occurs for films that are in the clean limit, where the superconducting coherence length (𝜉) is shorter than the mean free path (𝑙). Vortex motion-induced losses are suppressed for films in the dirty limit, which show evidence of structural defects that can pin vortices. We verify this hypothesis by explicitly pinning vortices via patterning, and we find that we can suppress the loss by microfabrication.

36 MATERIALS SCIENCE↗

Comparative magnetic studies of some Apollo 17 rocks and soils and their implications

The lunar rock and soil specimens studied include samples of the orange and gray soil strata from adjancent sites on the South rim of Shorty Crater, two vesicular mare basalts, and a mare basalt of the dense aphanitic type. The magnetic characteristics of the soils are discussed along with a hysteresis behavior analysis of Apollo 17 rocks. The remanent properties are examined, giving attention to viscous remanence, NRM stability, saturation isothermal remanence, and heating experiments.

Brecher, A.↗

Surface exposure indices of lunar soils - A comparative FMR study

The intensity of the characteristic FMR resonance of a lunar soil normalized to its total iron content (Is/FeO) was tested for use as its index of relative surface exposure age. The characteristic resonance is due to fine-grained metal that is the result of micrometeorite impact at the lunar surface. In this study, Is/FeO was measured for the below 250 micron size fraction of 152 soils and for the 90-150 micron size fraction of 88 soils. With this large suite of samples it was possible to correlate Is/FeO with a variety of other indices of relative surface exposure age (N, C, trapped He-4, trapped Ar-36, petrographic and magnetic agglutinates, and mean grain size) and thus not only affirm that Is/FeO is an index of relative surface exposure age but also consider the relative merits of the various surface exposure indices.

Morris, R. V.↗

Comparative magnetospheric/ionospheric studies using Dynamics Explorer spacecraft and ground-based radars

Coincident observations between the Dynamics Explorer 1 and 2 spacecraft with Chatanika and Arecibo ground-based radar are briefly reviewed. Ionospheric-magnetospheric coupling processes in the plasmasphere, main trough, auroral zone, and polar cap are inferred from the density, temperature, composition, and angular distributions of the low-energy plasma observed from the E-region ionosphere out into the magnetosphere to an altitude of 2.5 earth radii (Re). From the polar cap to the inner plasmasphere, parallel and perpendicular electric fields, polar wind flow, and equilibrium diffusion appear to be involved in the ionospheric-magnetospheric coupling of the low energy plasma.

Green, J. L.↗

Comparative magnetospheric/ionospheric studies using Dynamics Explorer spacecraft and ground-based radars

Coincident magnetosphere-ionosphere observations between the Dynamics Explorer 1 and 2 spacecraft with ground-based radar are reviewed. Ionospheric-magnetospheric coupling processes in the plasmasphere, main trough, auroral zone, and polar cap are inferred from the density, temperature, composition, and angular distributions of the low-energy plasma observed from the E-region ionosphere out into the magnetosphere to an altitude of 2.5 Re. From the polar cap to the inner plasmasphere, parallel and perpendicular electric fields, polar wind flow, and equilibrium diffusion appear to be involved in the ionospheric-magnetospheric coupling of the low energy plasma.

Green, J. L.↗

A comparative petrologic study of iron meteorites with radiogenic Ag-107 anomalies

The characteristics of the sulfide and metal phases of Derrick Peak, Cape York, Grant, Gibeon, and Santa Clara iron meteorite samples are examined. The textures and mineralogies of the samples are described. The effects of thermal and shock events on the distribution of Ag, and the relationship between Ag-107 and Pd are investigated. The correlation between the thermal histories and metal and sulfide nodules of the Gibeon and Santa Clara specimens is analyzed. It is noted that the Pd-107-Ag107 systematics involve the isotopic chemistry and cooling history of iron meteorites, the intensity of late extraterrestrial shock occurrences, and thermal processing.

Teshima, J.↗

The 27-28 October 1986 FIRE Cirrus case study - Retrieval of cloud particle sizes and optical depths from comparative analyses of aircraft and satellite-based infrared measurements

Infrared radiance measurements were acquired from a narrow-field nadir-viewing radiometer based on the NASA ER-2 aircraft during a coincident Landsat 5 overpass on October 28, 1986 as part of the FIRE Cirrus IFO in the vicinity of Lake Michigan. The spectral bandpasses are 9.90-10.87 microns for the ER-2-based radiometer and 10.40-12.50 microns for the Landsat thematic mapper band. After adjusting for spatial and temporal differences, a comparative study using data from these two instruments is undertaken in order to retrieve cirrus cloud ice-crystal sizes and optical depths. Retrieval is achieved by analysis of measurement correlations between the two spectral bands and comparison to multistream radiative transfer model calculations. The results indicate that the equivalent sphere radii of the cirrus ice crystals were typically less than 30 microns. Such particles were too small to be measured by the available in situ instrumentation. Cloud optical depths at a reference wavelength of 11.4 microns ranged from 0.3 to 2.0 for this case study. Supplemental results in support of this study are described using radiation measurements from the King Air aircraft, which was also in near coincidence with the Landsat overpass.

Hammer, Philip D.↗

Comparative Packaging Study

Future long duration manned space flights beyond low earth orbit will require the food system to remain safe, acceptable and nutritious. Development of high barrier food packaging will enable this requirement by preventing the ingress and egress of gases and moisture. New high barrier food packaging materials have been identified through a trade study. Practical application of this packaging material within a shelf life test will allow for better determination of whether this material will allow the food system to meet given requirements after the package has undergone processing. The reason to conduct shelf life testing, using a variety of packaging materials, stems from the need to preserve food used for mission durations of several years. Chemical reactions that take place during longer durations may decrease food quality to a point where crew physical or psychological well-being is compromised. This can result in a reduction or loss of mission success. The rate of chemical reactions, including oxidative rancidity and staling, can be controlled by limiting the reactants, reducing the amount of energy available to drive the reaction, and minimizing the amount of water available. Water not only acts as a media for microbial growth, but also as a reactant and means by which two reactants may come into contact with each other. The objective of this study is to evaluate three packaging materials for potential use in long duration space exploration missions.

Perchonok, Michele H.↗