Search NASA⌕ Search

SEARCH · Search NASA

Results for “Composites Load Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Prediction of Composite Pressure Vessel Failure Location using Fiber Bragg Grating Sensors

Ten composite pressure vessels were instrumented with fiber Bragg grating sensors in order to assess the strain levels of the vessel under various loading conditions. This paper and presentation will discuss the testing methodology, the test results, compare the testing results to the analytical model, and present a possible methodology for predicting the failure location and strain level of composite pressure vessels.

Kreger, Steven T.↗

Drop testing and analysis of six-foot diameter graphite-epoxy frames

Graphite-epoxy frames were drop tested onto a concrete floor to simulate crash loadings. The frames have Z-shaped cross-sections typical of designs often proposed for fuselage structure of advanced composite transports. The 6-foot diameter of the frames was chosen to reduce specimen fabrication costs and to facilitate testing. Response of the frames from accelerometer, strain gage, and photographic measurements are presented which characterize the behavior under 25-30 fps vertical impact velocity onto concrete. Failure of the graphite-epoxy frames involved a complete separation through the cross section near the impact point. All damage to the composite frame was confined to an area close to the impact point. Failure of aluminum frames tested for comparison were different from the composite specimens. The aluminum frames yielded (plastic hinges formed) at several locations around the lower portion of the frame without failing completely across the section.

Boitnott, R. L.↗

An Evaluation of the Iosipescu Specimen for Composite Materials Shear Property Measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. An experimental investigation using conventional strain gage instrumentation and moire interferometry is performed. A finite element analysis of the Iosipescu shear test for unidirectional and cross-ply composites is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon the strain gage measurements used for the determination of composite shear moduli. From the test results for graphite-epoxy laminates, it is shown that the proximity of the load introduction point to the test section greatly influences the individual gage readings for certain fiber orientations but the effect upon shear modulus measurement is relatively unimportant. A numerical study of the load contact effect shows the sensitivity of some fiber configurations to the specimen/fixture contact mechanism and may account for the variations in the measured shear moduli. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and yielded spurious shear stress-strain curves. In the numerical analysis, it is shown that the Iosipescu specimens for different fiber orientations have to be modeled differently in order to closely approximate the true loading conditions. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors, which are determined for the region occupied by the strain gage rosette, are found to be dependent upon the material orthotropic ratio and the finite element models. Based upon the experimental and numerical results, recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed. Further application of the Iosipescu shear test to woven fabric composites is presented. The limitations of the traditional strain gage instrumentation on the satin weave and high tow plain weave fabrics is discussed. Test results of a epoxy based aluminum particulate composite is also presented. A modification of the Iosipescu specimen is proposed and investigated experimentally and numerically. It is shown that the proposed new specimen design provides a more uniform shear stress field in the test section and greatly reduces the normal and shear stress concentrations in the vicinity of the notches. While the fabrication and the material cost of the proposed specimen is tremendously reduced, it is shown the accuracy of the shear modulus measurement is not sacrificed.

Ho, Henjen↗

In-situ x-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ x ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (0)1, (0)3, (0)5, and (0)8 composite specimens, showed that x ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

Improved Benchmarking of Cohesive Elements in Abaqus Standard for Predicting Disbond and Delamination in Composite Structures

Traditional approaches for aircraft certification require the assumption of an initial flaw condition, either represented as barely visible impact damage (BVID) or through inclusion of a Teflon insert to serve as surrogate damage. Based on the initial composite damage state, the structure must be shown to demonstrate structural durability and damage tolerance (DaDT) according to the following criteria: a. Damage displays no detrimental growth under cyclic loading b. The structure is able to sustain design limit load (DLL) Currently, the only available manner for validating structural performance is through test. Since damage can occur over a wide variety of areas within a structure, this approach has proven to be increasingly expensive and time consuming for composite airframes and acreage structure within the design-test-certification building block. A further complicating factor is the requirement to accurately capture the most critical damage morphologies as a starting condition. To understand the severity of the damage, it is either required to experimentally determine the most critical areas at tremendous expense or rely on legacy data of similar structural testing, which limits design space expansion. A preferred solution is to use advanced analysis to provide improved understanding of load margins for critical locations based on a wide variety of potential starting damage conditions. The standard industry approach for DaDT certification adheres to the use of the traditional virtual crack closure technique (VCCT) method. VCCT is generally a preferred method because it conforms to the current certification principles of damage from a known flaw, and when used correctly, can be effective at predicting delamination propagation under static and cyclic loading. The VCCT method requires the inclusion of an initial flaw in the finite element (FE) model requiring a-priori knowledge of the flaw location. This in turn requires a plethora of analysis cases to be examined to cover a reasonable span of potential damage states. Additionally, the VCCT approach requires node-to-node connectivity rendering it incompatible with the best practices and approaches for using continuum damage mechanics (CDM) based progressive damage and failure analysis (PDFA) tools within a typical FE solver. Alternatives to VCCT have emerged in the form of cohesive elements which utilize the cohesive zone model (CZM). Unlike VCCT which models linear elastic fracture mechanics, cohesive elements couples continuum and fracture based responses through the use of bilinear traction separation laws. These laws are defined based on a penalty stiffness, a cohesive strength, and a strain energy release rate. The approach can be mesh regularized with native cohesive elements within many FE solvers such as Abaqus and LS-DYNA. In Phase I of the NASA Advanced Composites Consortium (ACC) post-buckled stiffened panel with BVID, Strength and Life [1], the performance of cohesive elements were benchmarked in comparison to VCCT and LEFM solutions and showed good agreement using Abaqus explicit [2]. To realize savings on current and future programs, it is still necessary to close technical gaps related to the use of cohesive elements with Abaqus Standard. Within a program environment, standard finite element analysis is the preferred analytical capability for quasi-static loading as it eliminates uncertainty due to oscillatory behavior commonly seen with explicit analysis. This oscillatory behavior creates difficulties in writing margins of safety based on the analysis. The use of negative tangent stiffness material models complicates convergence which typically requires the use of numerical controls such as viscous damping to overcome. To date, there has not been a comprehensive study on how to establish best practices for cohesive element convergence for predictive capability within the Abaqus implicit solver. In pursuit of these goals, under the NASA ACC program, several numerical benchmark problems were proposed including pure mode I (double cantilevered beam – DCB), pure mode II (end notch flexure – ENF), and symmetric/unsymmetric evolving mixed mode (single leg bend – SLB). This paper focuses on the use of cohesive elements to model the delamination through the use of CZM. Specifically, finite element models for the DCB, ENF, symmetric SLB, and unsymmetric SLB, are developed and various solution controls for convergence are studied to develop a best practice. Once the best practice has been developed, the predictive capability of the objective CZM model is used to analyze the hat pull-off strength of a standard hat stiffened configuration under various loading conditions.

Abaqus↗

Fracture toughness of SiC/Al metal matrix composite

An experimental study was conducted to evaluate fracture toughness of SiC/Al metal matrix composite (MMC). The material was a 12.7 mm thick extrusion of 6061-T6 aluminum alloy with 40 v/o SiC particulates. Specimen configuration and test procedure conformed to ASTM E399 Standard for compact specimens. It was found that special procedures were necessary to obtain fatigue cracks of controlled lengths in the preparation of precracked specimens for the MMC material. Fatigue loading with both minimum and maximum loads in compression was used to start the precrack. The initial precracking would stop by self-arrest. Afterwards, the precrack could be safely extended to the desired length by additional cyclic tensile loading. Test results met practically all the E399 criteria for the calculation of plane strain fracture toughness of the material. A valid K sub IC value of the SiC/Al composite was established as K sub IC = 8.9 MPa square root of m. The threshold stress intensity under which crack would cease to grow in the material was estimated as delta K sub th = 2MPa square root of m for R = 0.09 using the fatigue precracking data. Fractographic examinations show that failure occurred by the micromechanism involved with plastic deformation although the specimens broke by brittle fracture. The effect of precracking by cyclic loading in compression on fracture toughness is included in the discussion.

Flom, Yury↗

Fracture toughness of SiC/Al metal matrix composite

An experimental study was conducted to evaluate fracture toughness of SiC/Al metal matrix composite (MMC). The material was a 12.7 mm thick extrusion of 6061-T6 aluminum alloy with 40 v/o SiC particulates. Specimen configuration and test procedure conformed to ASTM E399 Standard for compact specimens. It was found that special procedures were necessary to obtain fatigue cracks of controlled lengths in the preparation of precracked specimens for the MMC material. Fatigue loading with both minimum and maximum loads in compression was used to start the precrack. The initial precracking would stop by self-arrest. Afterwards, the precrack could be safely extended to the desired length by additional cyclic tensile loading. Test results met practically all the E399 criteria for the calculation of plane strain fracture toughness of the material. A valid K sub IC value of the SiC/Al composite was established as K sub IC = 8.9 MPa square root of m. The threshold stress intensity under which crack would cease to grow in the material was estimated as delta K sub th = 2MPa square root of m for R = 0.09 using the fatigue precracking data. Fractographic examinations show that failure occurred by the micromechanism involved with plastic deformation although the specimens broke by brittle fracture. The effect of precracking by cyclic loading in compression on fracture toughness is included in the discussion.

Flom, Yury↗

Orbit on demand - Structural analysis finds vertical launchers weigh less

Structural considerations arising from favored design concepts for the next generation on-demand launch vehicles are explored. The two emerging concepts are a two stage fully reusable vertical take-off vehicle (V-2) and a horizontal take-off, two stage subsonic boost launch vehicle (H-2-Sub). Both designs have an 1100 n. mi. cross-range capability, with the V-2 orbiter having small wings with winglets for hypersonic trim and the H-2-Sub requiring larger, swept wings. The rockets would be cryogenic, while airbreathing initial boosters would be either turbofans, turbojets and/or ramjets. Dynamic loading is lower in the launch of a V-2. The TPS is a critical factor due to thinner leading edges than on the Shuttle and may require heat-pipe cooling. Airframe structures made of metal matrix composites have passed finite element simulations of projected loads and can now undergo proof-of-concept tests, although whisker-reinforced materials may be superior once long-whisker technology is developed.

Taylor, A. H.↗

Damage Characteristics and Residual Strength of Composite Sandwich Panels Impacted with and Without Compression Loading

The results of an experimental study of the impact damage characteristics and residual strength of composite sandwich panels impacted with and without a compression loading are presented. Results of impact damage screening tests conducted to identify the impact-energy levels at which damage initiates and at which barely visible impact damage occurs in the impacted facesheet are discussed. Parametric effects studied in these tests include the impactor diameter, dropped-weight versus airgun-launched impactors, and the effect of the location of the impact site with respect to the panel boundaries. Residual strength results of panels tested in compression after impact are presented and compared with results of panels that are subjected to a compressive preload prior to being impacted.

McGowan, David M.↗

Thermomechanical Fatigue Damage/Failure Mechanisms in SCS-6/Timetal 21S [0/90](Sub S) Composite

The thermomechanical fatigue (TMF) deformation, damage, and life behaviors of SCS6/Timetal 21S (0/90)s were investigated under zero-tension conditions. In-phase (IP) and out-of-phase (OP) loadings were investigated with a temperature cycle from 150 to 650 deg C. An advanced TMF test technique was used to quantify mechanically damage progression. The technique incorporated explicit measurements of the macroscopic (1) isothermal static moduli at the temperature extremes of the TMF cycle and (2) coefficient of thermal expansion (CTE) as functions of the TMF cycles. The importance of thermal property degradation and its relevance to accurate post-test data analysis and interpretation is briefly addressed. Extensive fractography and metallography were conducted on specimens from failed and interrupted tests to characterize the extent of damage at the microstructure level. Fatigue life results indicated trends analogous to those established for similar unidirectional(0) reinforced titanium matrix composite systems. High stress IP and mid to low stress OP loading conditions were life-limiting in comparison to maximum temperature isothermal conditions. Dominant damage mechanisms changed with cycle type. Damage resulting from IP TMF conditions produced measurable decreases in static moduli but only minimal changes in the CTE. Metallography on interrupted and failed specimens revealed extensive (0) fiber cracking with sparse matrix damage. No surface initiated matrix cracks were present. Comparable OP TMF conditions initiated environment enhanced surface cracking and matrix cracking initiated at (90) fiber/matrix (F/M) interfaces. Notable static moduli and CTE degradations were measured. Fractography and metallography revealed that the transverse cracks originating from the surface and (90) F/M interfaces tended to converge and coalesce at the (0) fibers.

Castelli, Michael G.↗

Characterization of the Edge Crack Torsion (ECT) Test for Mode III Fracture Toughness Measurement of Laminated Composites

The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. An ECT specimen is a rectangular laminate, containing an edge delamination at the laminate mid-plane. Torsion load is applied to the specimens, resulting in relative transverse shear sliding of the delaminated faces. The test data reduction schemes are intended to yield initiation values of critical mode III strain energy release rate, G(sub IIIc), that are constant with delamination length. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design as a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and specimens made from S2/8552 tape laminates. Several specimens, each with different delamination lengths are tested. Detailed, three-dimensional finite element analyses of the specimens were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode III-dominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of G(sub IIIc) exhibited significant dependence on delamination length. Furthermore, there was a large amount of scatter in the data. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.

Ratcliffe, James G.↗

New Testing Tool For Composite Interfaces

Mechanical strength of fiber/matrix interface key factor in overall strength and toughness of composite material. Desktop fiber pushout apparatus generates load and acoustic-emission (soundwave) data as function of translation-table displacement. Video camera gives view of specimen. Compact, easy to operate, and inexpensive. Appropriate for wide range of composites, including metal, intermetallic, and ceramic matrix composites. Not restricted to aerospace/aeronautics applications.

Eldridge, Jeffrey I.↗

Application of a Developmental Composite Material Model to Predict the Crush Response of Two Energy Absorbers

In 2012, a consortium was formed with the goal of creating a new composite material model capable of predicting the wide range of properties, accumulated damage behavior, and the many different types of failure in composites under impact loading. The material model was developed for execution in the commercially available nonlinear, explicit transient dynamic finite element code, LS-DYNA®. This material model incorporates three sub-models: deformation, damage, and failure. In addition, the model accounts for strain rate and temperature effects and relies heavily on the input of tabulated material response data. The model is designated *MAT_COMPOSITE_TABULATED_PLASTICITY_DAMAGE, or *MAT_213. Initially, *MAT_213 was developed for use with solid elements only; however, a thin shell element formulation for *MAT_213 has been adapted recently. The objective of this project was to find a suitable modeling example to investigate the capabilities and performance of *MAT_213. In 2012, two composite energy absorbers were designed and evaluated at NASA Langley Research Center through multi-level testing and simulation. The first was a conical-shaped energy absorber, designated the conusoid, which consisted of four layers of hybrid carbon-Kevlar® plain-weave fabric oriented at [+45°/-45°/-45°/+45°] with respect to the vertical direction. The second was a sinusoidal-shaped energy absorber, designated the sinusoid, which consisted of hybrid carbon-Kevlar® plain-weave fabric face sheets, two layers for each face sheet oriented at ±45° with respect to the vertical direction, and a closed-cell ELFOAM® P200 polyisocyanurate foam core. Finite element models were developed of the energy absorbers and simulations were performed using LS-DYNA®. In this paper, the development of a *MAT_213 model of a hybrid carbon-Kevlar® plain-weave fabric is presented. Next, comparisons with material characterization tests are presented. Then, test-analysis results are documented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading using the *MAT_213 material model. Since a prior *MAT_58, or *MAT_LAMINATED_COMPOSITE_FABRIC material model was used in previous simulations of the energy absorbers, comparisons are made between *MAT_58 and *MAT_213 model predictions with test data. Finally, the paper includes a comprehensive list of “lessons learned,” in which a series of parametric studies are documented that were performed to investigate specific issues related to the material model. These “lessons learned” are included in hopes that they may help future *MAT_213 users.

crashworthiness, LS-DYNA transient dynamic simulat↗

Plasma-sprayed metal-glass and metal-glass fluoride coatings for lubrication to 900 C

Plasma-sprayed composites, which have good oxidation resistance and self-lubricating characteristics to 900 C, were developed. The composites are a nichrome matrix containing dispersed glass for oxidation protection and calcium fluoride for lubrication; they are applied to bearing surfaces by plasma spraying layers about 0.050 cm thick which are then machined to 0.025 cm. Oscillating bearing tests were performed in air to 900 C at unit radial loads up to 5000 psi and a thrust load of 440 lb. Bearings with a composite liner in the bore were in good condition after over 50,000 oscillating cycles accumulated during repeated bearing temperature cycles between 25 and 900 C.

Sliney, H. E.↗

In situ X-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ X-ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (O)1, (O)3, (O)5, and (O)8 composite specimens showed that X-ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

Some important aspects in testing high-modulus fiber composite tubes in axial tension.

Tubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation, and strain variations along the tube length and circumference. The investigation was limited to loading graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.

Sullivan, T. L.↗

Full-Field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites

Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape out of triaxial braided composite materials. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A more detailed investigation of deformation and failure processes in large-unit-cell-size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. This report presents some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12- and 24-k yarns and a 0 /+60 /-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed and correlations were made between these local failures and global composite deformation and strength.

Littell, Justin D.↗

Acoustic Emission Monitoring of the DC-XA Composite Liquid Hydrogen Tank During Structural Testing

The results of acoustic emission (AE) monitoring of the DC-XA composite liquid hydrogen tank are presented in this report. The tank was subjected to pressurization, tensile, and compressive loads at ambient temperatures and also while full of liquid nitrogen. The tank was also pressurized with liquid hydrogen. AE was used to monitor the tank for signs of structural defects developing during the test.

Wilkerson, C.↗