Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A fast scheme to calculate electronic couplings between P3HT polymer units using diabatic orbitals for charge transfer dynamics simulations

We propose a fast and accurate calculation method to compute the electronic couplings between molecular units in a thiophene-ring-based polymer chain mimicking a real organic semiconducting polymer, poly(3-hexylthiophene). Through a unit block diabatization scheme, the method employed minimal number of diabatic orbitals to compute the site energies and electronic couplings, which were validated by comparing with benchmark density functional theory calculations. In addition, by using the obtained electronic couplings, a quantum dynamics simulation was carried out to propagate a hole initially localized in a thiophene-ring unit of the polymer chain. Here, this work establishes a simple, efficient, and robust means for the simulation of electron or hole transfer processes in organic semiconducting materials, an important capability for study and understanding of the class of organic optoelectronic and photovoltaic materials.

36 MATERIALS SCIENCE↗

Multi-institutional Quantitative Evaluation and Clinical Validation of Smart Probabilistic Image Contouring Engine (SPICE) Autosegmentation of Target Structures and Normal Tissues on Computer Tomography Images in the Head and Neck, Thorax, Liver, and Male Pelvis Areas

Purpose: Clinical validation and quantitative evaluation of computed tomography (CT) image autosegmentation using Smart Probabilistic Image Contouring Engine (SPICE). Methods and Materials: CT images of 125 treated patients (32 head and neck [HN], 40 thorax, 23 liver, and 30 prostate) in 7 independent institutions were autosegmented using SPICE and computational times were recorded. The number of structures autocontoured were 25 for the HN, 7 for the thorax, 3 for the liver, and 6 for the male pelvis regions. Using the clinical contours as reference, autocontours of 22 selected structures were quantitatively evaluated using Dice Similarity Coefficient (DSC) and Mean Slice-wise Hausdorff Distance (MSHD). All 40 autocontours were evaluated by a radiation oncologist from the institution that treated the patients. Results: The mean computational times to autosegment all the structures using SPICE were 3.1 to 11.1 minutes per patient. For the HN region, the mean DSC was >0.70 for all evaluated structures, and the MSHD ranged from 3.2 to 10.0 mm. For the thorax region, the mean DSC was 0.95 for the lungs and 0.90 for the heart, and the MSHD ranged from 2.8 to 12.8 mm. For the liver region, the mean DSC was >0.92 for all structures, and the MSHD ranged from 5.2 to 15.9 mm. For the male pelvis region, the mean DSC was >0.76 for all structures, and the MSHD ranged from 4.8 to 10.5 mm. Out of the 40 autocontoured structures reviews by experts, 25 were scored useful as autocontoured or with minor edits for at least 90% of the patients and 33 were scored useful autocontoured or with minor edits for at least 80% of the patients. Conclusions: Compared with manual contouring, autosegmentation using SPICE for the HN, thorax, liver, and male pelvis regions is efficient and shows significant promise for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CALPHAD-based ICME design of single-step aging to enhance mechanical strength of WAAM Haynes 282

To match the strength of wire-arc additive manufactured Haynes 282 to its wrought counterpart via a single-step aging heat treatment, the CALPHAD (Calculation of Phase Diagrams) method is integrated with physics-based process-structure-property models and experimental validation. The integrated computational materials engineering (ICME) framework simulates the effects of aging on γ′ and M 23 C 6 precipitation and the resulting yield strength. To improve simulation reliability, the interfacial energies between γ/γ′ and γ/M 23 C 6 carbides were estimated by comparison with precipitation kinetic modeling and measured precipitate sizes. γ′ and M23C6 were found to precipitate simultaneously between 640 and 860 °C, producing microstructures similar to those produced by two-step aging. The optimal γ′ size for peak yield stress was calculated to be 20–23 nm. WAAM Haynes 282 aged at 780 °C for 50 h exceeded the mechanical performance of its wrought counterpart subjected to two-step aging, though desired properties can also be achieved at 800 °C for 16 h or less. The error in yield strength is less than 20 MPa, demonstrating good agreement between the modeling framework and experiments. Creep studies showed that WAAM Haynes 282 exceeded the calculated rupture time, reaching 481 h. This proposed methodology can accelerate the design of aging heat treatments for any γ′-strengthened nickel-base alloy, minimizing the resources required for trial-and-error experiments.

CALPHAD↗

Usage Of New Activation Function In Neuro-Symbolic Integration

New activation function is examined for its ability to accelerate the performance of doing logic programming in Hopfield network. This method has a higher capacity and upgrades the neuro symbolic integration. Computer simulations are carried out to validate the effectiveness of the new activation function. Empirical results obtained support our theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Desmearing two-dimensional small-angle neutron scattering data by central moment expansions

Resolution smearing is a critical challenge in the quantitative analysis of two-dimensional small-angle neutron scattering (SANS) data, particularly in studies of soft-matter flow and deformation using SANS. Here, we present a central moment expansion technique to address smearing in anisotropic scattering spectra, offering a model-free desmearing methodology. By accounting for directional variations in resolution smearing and enhancing computational efficiency, this approach reconstructs desmeared intensity distributions from smeared experimental data. Computational benchmarks using interacting hard-sphere fluids and Gaussian chain models validate the accuracy of the method, while simulated noise analyses confirm its robustness under experimental conditions. Experimental validation using rheological SANS data from shear-induced micellar structures demonstrates the practicality and effectiveness of the proposed algorithm. The desmearing technique provides a powerful tool for advancing the quantitative analysis of anisotropic scattering patterns, enabling precise insights into the interplay between material microstructure and macroscopic flow behavior.

anisotropic scattering spectra↗

Acquisition and Processing Considerations for Infrared Images of Rotating Turbine Blades

Abstract As designers aim to increase efficiency in gas turbines for aircraft propulsion and power generation, spatially resolved experimental measurements are needed to validate computational models and compare improvement gains of new cooling designs. Infrared (IR) thermography is one such method for obtaining spatially resolved temperature measurements. As technological advances in thermal detectors enable faster integration times, surface temperature measurements of rotating turbine blades become possible to capture including the smallest features. This paper outlines opportunities enabled by the latest IR detector technologies for capturing spatially resolved rotating blade temperatures, while also addressing some of the challenges of implementing IR for turbine rigs such as the one in the Steady Thermal Aero Research Turbine (START) Laboratory. This paper documents critical steps in achieving accurate measurements including calibration, integration times, spatial noise, and motion blur. From these results, recommendations are provided for achieving accurate IR measurements collected in a rotating turbine facility to study film cooling.

Engineering↗

SU-E-T-175: Clinical Evaluations of Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Radiotherapy

Purpose: Pencil-beam or superposition-convolution type dose calculation algorithms are routinely used in inverse plan optimization for intensity modulated radiation therapy (IMRT). However, due to their limited accuracy in some challenging cases, e.g. lung, the resulting dose may lose its optimality after being recomputed using an accurate algorithm, e.g. Monte Carlo (MC). It is the objective of this study to evaluate the feasibility and advantages of a new method to include MC in the treatment planning process. Methods: We developed a scheme to iteratively perform MC-based beamlet dose calculations and plan optimization. In the MC stage, a GPU-based dose engine was used and the particle number sampled from a beamlet was proportional to its optimized fluence from the previous step. We tested this scheme in four lung cancer IMRT cases. For each case, the original plan dose, plan dose re-computed by MC, and dose optimized by our scheme were obtained. Clinically relevant dosimetric quantities in these three plans were compared. Results: Although the original plan achieved a satisfactory PDV dose coverage, after re-computing doses using MC method, it was found that the PTV D95% were reduced by 4.60%–6.67%. After re-optimizing these cases with our scheme, the PTV coverage was improved to the same level as in the original plan, while the critical OAR coverages were maintained to clinically acceptable levels. Regarding the computation time, it took on average 144 sec per case using only one GPU card, including both MC-based beamlet dose calculation and treatment plan optimization. Conclusion: The achieved dosimetric gains and high computational efficiency indicate the feasibility and advantages of the proposed MC-based IMRT optimization method. Comprehensive validations in more patient cases are in progress.

60 APPLIED LIFE SCIENCES↗

Free Energy and Heat Capacity

Free energy and heat capacity of actinide elements and compounds are important properties for the evaluation of the safety and reliable performance of nuclear fuel. They are essential inputs for models that describe complex phenomena that govern the behaviour of actinide compounds during nuclear fuel fabrication and irradiation. This chapter introduces various experimental methods to measure free energy and heat capacity to serve as inputs for models and to validate computer simulations. This is followed by a discussion of computer simulation of these properties, and recent simulations of thermophysical properties of nuclear fuel are briefly reviewed.

free energy↗

Spatiotemporal Super-Resolution with Generative Machine Learning for Creating Renewable Energy Resource Data Under Climate Change Scenarios

As we plan for a future with higher penetrations of renewables and increasing electrification, it becomes more important to understand how the electricity grid will operate under a variety of weather events. We must also consider that the weather our future grid will experience will be different and possibly more extreme than the historical weather that we have extensive data for. We can use data from global climate models (GCMs) to help understand how our climate may change over the next several decades, but there is often a significant gap between the low-resolution GCM data and the high-resolution weather data required to study power systems under specific weather events. Therefore, our objective in this work is to develop tools that can bridge this gap by using low-resolution GCM data to create realistic high-resolution weather datasets that can be used to study renewable energy generation and electricity demand. To accomplish this objective, we have developed a set of generative machine learning models that can rapidly downscale GCM daily average output data at an approximate grid resolution of 100km to hourly data at an approximate 4 km grid resolution. The models can be used to create high resolution data from nearly any GCM included in the Coupled Model Intercomparison Project (CMIP) Phase 5 or 6. Our methods include all datasets regularly used to study the integration of wind and solar power plants as well as changes in electricity demand due to heating and cooling loads. These models and datasets enable power systems modelers to study climate change-influenced weather events and their impact on the grid. We have downscaled and validated wind, solar, temperature, and humidity data with very promising results. The generative machine learning methods are computationally efficient and produce data that has similar statistical characteristics to current state-of-the-art historical datasets. We have trained initial generative models and produced an initial dataset collectively referred to as Sup3rCC: Super-Resolved Renewable Energy Resource Data with Climate Change Impacts. The data covers a (mostly) historical period from 2015-2025 and a future period from 2050-2059. We have also taken hypothetical high-electrification load data and scaled the heating and cooling loads with respect to the 2050-2059 high-resolution Sup3rCC meteorology. The results show how future levels of renewable energy generation and electrified load may be impacted by climate change, setting the stage for capacity expansion models to consider a dynamic climate through model years.

climate change↗

Simplified method for deducing high-energy neutron spectra between 1 and 100 MeV using Foil-Activation Method

The Japanese and American Study of Muon Interaction and Neutron detection (JASMIN) collaboration, has been conducting shielding experiments using the Fermilab anti-proton target station (Pbar) shielding assembly. A multi-foil technique was used to measure the high energy neutron spectra, in the range of 1 to 100 MeV, for the target station shielding configuration. The neutron spectra were de-convoluted using a new fitting method. This method is based on the assumption that a neutron spectrum can be expressed as a simple sum of two exponentials. The validity of the fitting method was confirmed by comparison with the results obtained using SAND-II computer code and theoretical calculations. Finally, it was found that there are simple correlations between reaction rates and the adjustable parameters in the fitting function. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the Reproducibility of Noisy Quantum Circuits

The ability of a quantum computer to reproduce or replicate the results of a quantum circuit is a key concern for verifying and validating applications of quantum computing. Statistical variations in circuit outcomes that arise from ill-characterized fluctuations in device noise may lead to computational errors and irreproducible results. While device characterization offers a direct assessment of noise, an outstanding concern is how such metrics bound the reproducibility of a given quantum circuit. Here, we first directly assess the reproducibility of a noisy quantum circuit, in terms of the Hellinger distance between the computational results, and then we show that device characterization offers an analytic bound on the observed variability. We validate the method using an ensemble of single qubit test circuits, executed on a superconducting transmon processor with well-characterized readout and gate error rates. The resulting description for circuit reproducibility, in terms of a composite device parameter, is confirmed to define an upper bound on the observed Hellinger distance, across the variable test circuits. This predictive correlation between circuit outcomes and device characterization offers an efficient method for assessing the reproducibility of noisy quantum circuits.

97 MATHEMATICS AND COMPUTING↗

MCNP Progress for the Nuclear Criticality Safety Program

The DOE/NNSA Nuclear Criticality Safety Program (NCSP) supports research, development, maintenance, and verification and validation of the MCNP{sup R} Monte Carlo radiation transport software package for nuclear criticality safety (NCS) customers within DOE/NNSA. The MCNP Monte Carlo code has been used for high-fidelity analyses of criticality safety problems since the 1970's. This paper summarizes MCNP progress during FY 2015 and early FY 2016. Activities and accomplishments are summarized in five major areas: - MCNP6 status, - Whisper status, - Verification and validation testing, - User support and training, - Work in progress. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculated using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.

60 APPLIED LIFE SCIENCES↗

SU-F-J-192: A Quick and Effective Method to Validate Patient’s Daily Setup and Geometry Changes Prior to Proton Treatment Delivery Based On Water Equivalent Thickness Projection Imaging (WETPI) for Head Neck Cancer (HNC) Patient

Purpose: With the implementation of Cone-beam Computed-Tomography (CBCT) in proton treatment, we introduces a quick and effective tool to verify the patient’s daily setup and geometry changes based on the Water-Equivalent-Thickness Projection-Image(WETPI) from individual beam angle. Methods: A bilateral head neck cancer(HNC) patient previously treated via VMAT was used in this study. The patient received 35 daily CBCT during the whole treatment and there is no significant weight change. The CT numbers of daily CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration(DIR). IMPT plan was generated using 4-field IMPT robust optimization (3.5% range and 3mm setup uncertainties) with beam angle 60, 135, 300, 225 degree. WETPI within CTV through all beam directions were calculated. 3%/3mm gamma index(GI) were used to provide a quantitative comparison between initial sim-CT and mapped daily CBCT. To simulate an extreme case where human error is involved, a couch bar was manually inserted in front of beam angle 225 degree of one CBCT. WETPI was compared in this scenario. Results: The average of GI passing rate of this patient from different beam angles throughout the treatment course is 91.5 ± 8.6. In the cases with low passing rate, it was found that the difference between shoulder and neck angle as well as the head rest often causes major deviation. This indicates that the most challenge in treating HNC is the setup around neck area. In the extreme case where a couch bar is accidently inserted in the beam line, GI passing rate drops to 52 from 95. Conclusion: WETPI and quantitative gamma analysis give clinicians, therapists and physicists a quick feedback of the patient’s setup accuracy or geometry changes. The tool could effectively avoid some human errors. Furthermore, this tool could be used potentially as an initial signal to trigger plan adaptation.

60 APPLIED LIFE SCIENCES↗

Practical Introduction to Benchmarking and Characterization of Quantum Computers

Rapid progress in quantum technology has transformed quantum computing and quantum information science from theoretical possibilities into tangible engineering challenges. Breakthroughs in quantum algorithms, quantum simulations, and quantum error correction are bringing useful quantum computation closer to fruition. These remarkable achievements have been facilitated by advances in quantum characterization, verification, and validation (QCVV). QCVV methods and protocols enable scientists and engineers to scrutinize, understand, and enhance the performance of quantum information-processing devices. In this tutorial, we review the fundamental principles underpinning QCVV, and introduce a diverse array of QCVV tools used by quantum researchers. We define and explain QCVV’s core models and concepts—quantum states, measurements, and processes—and illustrate how these building blocks are leveraged to examine a target system or operation. We survey and introduce protocols ranging from simple qubit characterization to advanced benchmarking methods. Along the way, we provide illustrated examples and detailed descriptions of the protocols, highlight the advantages and disadvantages of each, and discuss their potential scalability to future large-scale quantum computers. This tutorial serves as a guidebook for researchers unfamiliar with the benchmarking and characterization of quantum computers, and also as a detailed reference for experienced practitioners.

open quantum systems & decoherence↗

Radiation doses in cone-beam breast computed tomography: A Monte Carlo simulation study

Purpose: In this article, we describe a method to estimate the spatial dose variation, average dose and mean glandular dose (MGD) for a real breast using Monte Carlo simulation based on cone beam breast computed tomography (CBBCT) images. We present and discuss the dose estimation results for 19 mastectomy breast specimens, 4 homogeneous breast models, 6 ellipsoidal phantoms, and 6 cylindrical phantoms. Methods: To validate the Monte Carlo method for dose estimation in CBBCT, we compared the Monte Carlo dose estimates with the thermoluminescent dosimeter measurements at various radial positions in two polycarbonate cylinders (11- and 15-cm in diameter). Cone-beam computed tomography (CBCT) images of 19 mastectomy breast specimens, obtained with a bench-top experimental scanner, were segmented and used to construct 19 structured breast models. Monte Carlo simulation of CBBCT with these models was performed and used to estimate the point doses, average doses, and mean glandular doses for unit open air exposure at the iso-center. Mass based glandularity values were computed and used to investigate their effects on the average doses as well as the mean glandular doses. Average doses for 4 homogeneous breast models were estimated and compared to those of the corresponding structured breast models to investigate the effect of tissue structures. Average doses for ellipsoidal and cylindrical digital phantoms of identical diameter and height were also estimated for various glandularity values and compared with those for the structured breast models. Results: The absorbed dose maps for structured breast models show that doses in the glandular tissue were higher than those in the nearby adipose tissue. Estimated average doses for the homogeneous breast models were almost identical to those for the structured breast models (p=1). Normalized average doses estimated for the ellipsoidal phantoms were similar to those for the structured breast models (root mean square (rms) percentage difference=1.7%; p=0.01), whereas those for the cylindrical phantoms were significantly lower (rms percentage difference=7.7%; p<0.01). Normalized MGDs were found to decrease with increasing glandularity. Conclusions: Our results indicate that it is sufficient to use homogeneous breast models derived from CBCT generated structured breast models to estimate the average dose. This investigation also shows that ellipsoidal digital phantoms of similar dimensions (diameter and height) and glandularity to actual breasts may be used to represent a real breast to estimate the average breast dose with Monte Carlo simulation. We have also successfully demonstrated the use of structured breast models to estimate the true MGDs and shown that the normalized MGDs decreased with the glandularity as previously reported by other researchers for CBBCT or mammography.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

60 APPLIED LIFE SCIENCES↗

Experimental validation of the Cristal V2.0 French criticality calculation package - 14587

A new version of the CRISTAL criticality calculation package, named CRISTAL V2.0 [1], has been developed by IRSN and CEA, in collaboration with AREVA and EDF. Four calculation routes are now available, using nuclear data issued from the JEFF-3.1.1 evaluation: two multigroup routes based on 281 groups cross-sections (APOLLO2 - MORET 5 or APOLLO2-Sn calculations), a pointwise Monte Carlo route (TRIPOLI-4{sup R}) and a criticality standard calculation route. The CRISTAL V2.0 package, which will be delivered soon to OECD/NEA data bank, benefits from a broad validation database covering almost all areas of criticality-safety applications, from fuel fabrication to reprocessing, including transportation. 3,127 critical experiments, corresponding to 342 series, either issued from the OECD/ICSBEP Handbook or performed in French facilities (confidential data) were selected for the CRISTAL V2.0 validation database. Currently, more than 2,300 experiments are already part of the validation database. This validation work highlights an overall consistency to experimental data and inter-comparisons between the different calculation routes mainly show good agreements on a large set of common experiments. (authors)

42 ENGINEERING↗