Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Short-Range Structure of Amorphous Calcium Hydrogen Phosphate

Calcium orthophosphates (CaPs) are the hard constituents of bones and teeth, and thus of ultimate importance to humankind, while amorphous CaPs (ACPs) may play crucial roles in CaP biomineralization. Among the various ACPs with Ca/P atomic ratios between 1.0–1.5, an established structural model exists for basic ACP (Ca/P = 1.5), while those of other ACPs remain unclear. In this work, the structure of amorphous calcium hydrogen phosphate (ACHP; Ca/P = 1.0) obtained via aqueous routes at near-neutral pH values, without stabilizers, was studied by experiments (mainly, TEM with ED, XRD, IR, and NMR spectroscopies, as well as XAS) and computer simulation. Our results globally show that ACHP has a distinct short-range structure, and we propose calcium hydrogen phosphate clusters (CHPCs) as its basic unit. This model is consistent with both computer simulations and the experimental results, where CHPCs are arranged together with water molecules to build up ACHP. We demonstrate that Posner’s clusters, which are conventionally accepted to be the building unit of basic ACPs, do not represent the short-range structure of ACHP, as Posner’s clusters and CHPCs are structurally distinct. This finding is important not only for the determination of the structures of diverse ACPs with varying Ca/P atomic ratios but also for fundamental understanding of a major mineral class that is central to biomineralization in vertebrates and, thus, humans, in particular.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient gradient estimation using finite differencing and likelihood ratios for kinetic Monte Carlo simulations

While many optimization and control methods for stochastic processes require gradient information from the process of interest, obtaining gradient information from experiments is prohibitively expensive and time-consuming. As a result, such information is often obtained from stochastic process simulations. Computing gradients efficiently and accurately from stochastic simulations is challenging, especially for simulations involving computationally expensive models with significant inherent noise. In this work, we analyze and characterize the applicability of two gradient estimation methods for kinetic Monte Carlo simulations: finite differencing and likelihood ratio. We developed a systematic method for choosing an optimal perturbation size for finite differencing and discuss, for both methods, important implementation issues such as scaling with respect to the number of elements in the gradient vector. Through a series of numerical experiments, the methods were compared across different time and size regimes to characterize the precision and accuracy associated with each method. We determined that the likelihood ratio method is appropriate for estimating gradients at short (transient) times or for systems with small population sizes, whereas finite differencing is better-suited for gradient estimation at long times (steady state) or for systems with large population sizes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy setup for pulsed and constant wave X-ray light sources

An apparatus for sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy studies with pulsed and constant wave X-ray light sources is presented. A differentially pumped hemispherical electron analyzer is equipped with a delay-line detector that simultaneously records the position and arrival time of every single electron at the exit aperture of the hemisphere with ∼0.1 mm spatial resolution and ∼150 ps temporal accuracy. The kinetic energies of the photoelectrons are encoded in the hit positions along the dispersive axis of the two-dimensional detector. Pump-probe time-delays are provided by the electron arrival times relative to the pump pulse timing. An average time-resolution of (780 ± 20) ps (FWHM) is demonstrated for a hemisphere pass energy E{sub p} = 150 eV and an electron kinetic energy range KE = 503–508 eV. The time-resolution of the setup is limited by the electron time-of-flight (TOF) spread related to the electron trajectory distribution within the analyzer hemisphere and within the electrostatic lens system that images the interaction volume onto the hemisphere entrance slit. The TOF spread for electrons with KE = 430 eV varies between ∼9 ns at a pass energy of 50 eV and ∼1 ns at pass energies between 200 eV and 400 eV. The correlation between the retarding ratio and the TOF spread is evaluated by means of both analytical descriptions of the electron trajectories within the analyzer hemisphere and computer simulations of the entire trajectories including the electrostatic lens system. In agreement with previous studies, we find that the by far dominant contribution to the TOF spread is acquired within the hemisphere. However, both experiment and computer simulations show that the lens system indirectly affects the time resolution of the setup to a significant extent by inducing a strong dependence of the angular spread of electron trajectories entering the hemisphere on the retarding ratio. The scaling of the angular spread with the retarding ratio can be well approximated by applying Liouville's theorem of constant emittance to the electron trajectories inside the lens system. The performance of the setup is demonstrated by characterizing the laser fluence-dependent transient surface photovoltage response of a laser-excited Si(100) sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressing unstructured mesh data from simulations using machine learning

The amount of data output from a computer simulation has grown to terabytes and petabytes as increasingly complex simulations are being run on massively parallel systems. As we approach exaflop computing in the next decade, it is expected that the I/O subsystem will not be able to write out these large volumes of data. In this paper, we explore the use of machine learning to compress the data before it is written out. Despite the computational constraints that limit us to using very simple learning algorithms, our results show that machine learning is a viable option for compressing unstructured data. Furthermore, we demonstrate that by simply using a better sampling algorithm to generate the training set, we can obtain more accurate results compared to random sampling, but at no extra cost. Further, by carefully selecting and incorporating points with high prediction error, we can improve reconstruction accuracy without sacrificing the compression rate.

97 MATHEMATICS AND COMPUTING↗

EVOLUTION OF THE MAGNETIC FIELD LINE DIFFUSION COEFFICIENT AND NON-GAUSSIAN STATISTICS

The magnetic field line random walk (FLRW) plays an important role in the transport of energy and particles in turbulent plasmas. For magnetic fluctuations that are transverse or almost transverse to a large-scale mean magnetic field, theories describing the FLRW usually predict asymptotic diffusion of magnetic field lines perpendicular to the mean field. Such theories often depend on the assumption that one can relate the Lagrangian and Eulerian statistics of the magnetic field via Corrsin’s hypothesis, and additionally take the distribution of magnetic field line displacements to be Gaussian. Here we take an ordinary differential equation (ODE) model with these underlying assumptions and test how well it describes the evolution of the magnetic field line diffusion coefficient in 2D+slab magnetic turbulence, by comparisons to computer simulations that do not involve such assumptions. In addition, we directly test the accuracy of the Corrsin approximation to the Lagrangian correlation. Over much of the studied parameter space we find that the ODE model is in fairly good agreement with computer simulations, in terms of both the evolution and asymptotic values of the diffusion coefficient. When there is poor agreement, we show that this can be largely attributed to the failure of Corrsin’s hypothesis rather than the assumption of Gaussian statistics of field line displacements. The degree of non-Gaussianity, which we measure in terms of the kurtosis, appears to be an indicator of how well Corrsin’s approximation works.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-EF-204-10: A Preliminary Study Evaluating Calculation Variations of Local Noise Power Spectra for CT Simulation in Radiation Therapy

Purpose: Local noise power spectrum (NPS) properties are significantly affected by calculation variables and CT acquisition and reconstruction parameters, but a thoughtful analysis of these effects is absent. In this study, we performed a complete analysis of the effects of calculation and imaging parameters on the NPS. Methods: The uniformity module of a Catphan phantom was scanned with a Philips Brilliance 64-slice CT simulator using various scanning protocols. Images were reconstructed using both FBP and iDose4 reconstruction algorithms. From these images, local NPS were calculated for regions of interest (ROI) of varying locations and sizes, using four image background removal methods. Additionally, using a predetermined ground truth, NPS calculation accuracy for various calculation parameters was compared for computer simulated ROIs. A complete analysis of the effects of calculation, acquisition, and reconstruction parameters on the NPS was conducted. Results: The local NPS varied with ROI size and image background removal method, particularly at low spatial frequencies. The image subtraction method was the most accurate according to the computer simulation study, and was also the most effective at removing low frequency background components in the acquired data. However, first-order polynomial fitting using residual sum of squares and principle component analysis provided comparable accuracy under certain situations. Similar general trends were observed when comparing the NPS for FBP to that of iDose4 while varying other calculation and scanning parameters. However, while iDose4 reduces the noise magnitude compared to FBP, this reduction is spatial-frequency dependent, further affecting NPS variations at low spatial frequencies. Conclusion: The local NPS varies significantly depending on calculation parameters, image acquisition parameters, and reconstruction techniques. Appropriate local NPS calculation should be performed to capture spatial variations of noise; calculation methodology should be selected with consideration of image reconstruction effects and the desired purpose of CT simulation for radiotherapy tasks.

60 APPLIED LIFE SCIENCES↗

Sierra/SD – Verification Test Manual – 5.22

Verification and validation (V&V) of scientific computing programs are important at Sandia National Labs due to the expanding role of computational simulation in managing the United States nuclear stockpile. The complexities of structural response calculations used to analyze physical problems, the varieties of codes applied to the calculations, and the importance of accurate predictions when assessing field conditions demand confidence in the consistency and accuracy of computer codes. Confidence in the accuracy of the predictions arising from computer simulations must ultimately be gained through verification and validation. The Sierra salinas structural dynamics analysis code, Sierra/SD, is used at the DOE Laboratories, and in several DOD projects. The roles of Sierra/SD in the qualification of weapon systems and components for normal and hostile environments throughout the Stockpile-to-Target Sequence include to, • Redesign weapon components. • Certify weapon components and systems for target environments such as hypersonic vehicles. • Certify that components will survive the thermal mechanical shock loads associated with hostile environments. • Evaluate current stockpile issues, including issues associated with uncertainty quantification. • Address many other problems that are encountered in stockpile management. The Sierra/SD verification plan is described, and an evolving set of key verification tests are described in detail. The verification tests ensure the correctness of the mathematics and numerical algorithms associated with functionality describing engineering phenomena. Development is in accordance with a set of tailored Software Quality Engineering (SQE) practices. SQE practices guide the overall verification and validation effort.

97 MATHEMATICS AND COMPUTING↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of Molecular Structure and Dynamics of Molten Salts by Advanced Neutron and X-ray Scattering Measurements and Computer Modeling

The design and development of fully functional Molten-Salt Reactors (MSR) require detailed knowledge of the molten salt properties in order to understand and predict the salt’s behavior. Fundamental properties of interest include molecular structure, speciation, and dynamics (such as diffusion coefficients) of salt components and dissolved corrosion and fission products. Computer modeling is necessary to predict changes in physical and chemical properties due to irradiation, burning of dissolved fuel, and corrosion. The modeling requires experimental data, and advanced neutron and x-ray scattering and spectroscopy provide the most reliable and direct determination of the structure (Pair-Distribution Functions, PDF), and dynamics of ions in the melt. This project dealt with both fluoride and chloride salts. The PDFs have been measured by a combination of neutron and x-ray diffraction. We utilized the techniques of isotope substitutions, a very powerful tool available for neutron-scattering, to extract the details of the liquid structure. Although similar measurements have been done before, modern advanced neutron and x-ray-scattering techniques allow collecting the data at much higher resolution and in a wider range of temperatures. Importantly, we were among the first to study fluoride salts by neutron scattering. The importance of impurities and their effects on salt properties have become apparent recently and so new methods of salt purification were developed. We took advantage of these developments to produce reliable data, which have been used for computer simulations of both clean salts and those with added fission and corrosion products most relevant for MSRs. Ab initio molecular dynamics simulations have been performed to understand the multi-component liquid solution, in particular solubility of impurities and thermodynamic interactions in relation to the ionic-cluster structure of the fluid. We applied machine learning to regress from the simulation and experimental data in order to develop a fast-acting model that can handle molten salt with an arbitrary (≥ 10) number of chemical elements and be able to predict chemical potential as a function of composition and temperature. This project resulted in a number of experimental and computer-simulation publications, a patent application, and numerous conference presentations (American Physical Society, American Chemical Society, and The Electrochemical Society among others). Multiple students and postdocs participated and collaborated on aspects of this project. This project seeded new collaborations between MIT and other institutions, such as the University of Massachusetts Lowell, the University of Illinois Urbana-Champaign, the University of California Berkeley, and Oak Ridge and Los Alamos National Labs. As such, this project has had a broad and lasting impact beyond its original scientific scope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE Non-LWR Models for NRC Volume 3

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory and reactivity analyses of various advanced reactors. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sooting tendencies of co-optima test gasolines and their surrogates

Here, this study characterized the sooting tendencies of a set of gasolines and their surrogates using both experimental and computational methods. Sooting tendency was defined in terms of the soot yield when 1000 ppm of the test fuel is doped into the fuel of a methane/air flame, and it provides a measure of the intrinsic chemical tendency of the fuels to form soot in a generic combustion environment. The test fuels were real gasolines containing enhanced concentrations of alkanes, aromatics, cycloalkanes, olefins, and ethanol. These compositional differences caused the experimentally measured sooting tendencies of the fuels to vary by 240%. The surrogates were 3 mixtures defined by Szybist et al. (2017) and 3 alternative formulations modified for greater experimental convenience. The sooting tendencies measured for the surrogate mixtures agreed with the real fuels to within 15%, and varied with composition in the same order. The sooting tendencies of the surrogates could be predicted to within experimental error with an empirical quantitative structure-property relationship and a linear mixing model. The experimental flames were computationally simulated with a 743-species mechanism, and sooting tendencies derived from the results agreed with the measured values to within 11%. Altogether, these results show that the sooting behavior of gasoline can vary considerably within the range of acceptable compositions, and that these variations can be accurately predicted with empirical models and computational simulations.

09 BIOMASS FUELS↗

Future Research Needed to Study the Response of an Explosive Assembly to Mechanical Insults

HE ignition caused by shear localization is the principal concern for safety analyses of postulated mechanical insults to explosive assemblies. Although prompt detonation from shock is certainly a concern, insults that lead to prompt detonation are associated with high velocity, and correspondingly rare. For high-density HMX assemblies, an impact speed (by a steel object) of 400 m/s is needed to develop a detonation in a run distance less than 30 mm. To achieve a steady plane shock, which results in the shortest run distance to detonation for a given peak pressure, the impactor diameter must exceed 60 mm, and thickness approach 20 mm. Thinner plates and/or smaller diameter ones require even higher impact velocity. Ignitions from shear localization, however, have been observed from impacts less than 50 m/s in Steven tests, less than 30 m/s from spigot impact tests, and less than 10 m/s from various drop tests. This lower velocity range is much frequent in postulated mechanical insults. Preliminary computer simulations and analyses of a variety of such tests have suggested that although each is accompanied by shear localization, there are differing detailed mechanisms at work that cause the ignitions. We identify those mechanisms that may be at work in a variety of such tests, and suggest how models of shear ignition, such as HERMES, may be revised and calibrated to conform to experiment. We suggest combining additional experiments with computer simulations and model development to begin confirm or uncover mechanisms that may be at work in a specific postulated event.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-energy correlations in liquids. III. Statistical mechanics and thermodynamics of liquids with hidden scale invariance

In this third paper of the series, which started with Bailey et al. [J. Chem. Phys.129, 184507 (2008);ibid.129, 184508 (2008)], we continue the development of the theoretical understanding of strongly correlating liquids—those whose instantaneous potential energy and virial are more than 90% correlated in their thermal equilibrium fluctuations at constant volume. The existence of such liquids was detailed in previous work, which identified them, based on computer simulations, as a large class of liquids, including van der Waals liquids but not, e.g., hydrogen-bonded liquids. We here discuss the following: (1) the scaling properties of inverse power-law and extended inverse power-law potentials (the latter includes a linear term that “hides” the approximate scale invariance); (2) results from computer simulations of molecular models concerning out-of-equilibrium conditions; (3) ensemble dependence of the virial/potential-energy correlation coefficient; (4) connection to the Grüneisen parameter; and (5) interpretation of strong correlations in terms of the energy-bond formalism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

SCALE Non-LWR Models for NRC Volume 5

This dataset contains input and result files of computational simulations with the SCALE code system. The simulations cover radionuclide inventory generation, criticality calculations, and dose rate/shielding analyses of various advanced reactors. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗