Search NASA⌕ Search

SEARCH · Search NASA

Results for “Condition Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Control Chart Approach for Representing and Mining Data Streams with Shape Based Similarity

The mining of data streams for online condition monitoring is a challenging task in several domains including (electric) power grid system, intelligent manufacturing, and consumer science. Considering a power grid application in which thousands of sensors, called the phasor measurement units, are deployed on the power grid network to continuously collect streams of digital data for real-time situational awareness and system management. Depending on design, each sensor could stream between ten and sixty data samples per second. The myriad of sensory data captured could convey deeper insights about sequence of events in real-time and before major damages are done. However, the timely processing and analysis of these high-velocity and high-volume data streams is a challenge. Hence, a new data processing and transformation approach, based on the concept of control charts, for representing sequence of data streams from sensors is proposed. In addition, an application of the proposed approach for enhancing data mining tasks such as clustering using real-world power grid data streams is presented. The results indicate that the proposed approach is very efficient for data streams storage and manipulation.

big data↗

Drivetrain Reliability from Inherent to Operational

Despite reliability improvements made to wind turbine drivetrains over the years, premature component failures are still challenging the wind industry. There are, however, opportunities to understand drivetrain reliability challenges and investigate potential mitigation solutions. This presentation discusses a few research and development (R&D) activities on drivetrain reliability carried out by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) over the last ten years. It covers two angles of reliability, inherent and operational, and goes into detail on specific R&D activities. Some inherent reliability challenges covered include gearbox planetary stage loads investigation, high speed shaft and main bearing operational condition understanding, dynamic modeling approaches, and recommended practices. The R&D activities on operational reliability improvements covered include benchmarking, performance and condition monitoring, and predictions on the remaining useful life of components. The presentation concludes with a list of necessary drivetrain reliability improvements that could close the loop between operational and inherent reliability efforts. The team hopes that some of these lessons learned can contribute to relevant international standards or recommended practices.

17 WIND ENERGY↗

Impact of CSPE Jackets on Accelerated Aging of Harvested Cable Insulations in Support of Remaining Useful Life Assessments

Nuclear power plants (NPPs) are operating beyond their original 40-year operating lifetime, with more than 80% operating on the first license renewal for an extended 20-years. To sustain the effective and cost-effective operation of their electrical cables, understanding cable material performance in current and future environments can lead to effective maintenance strategies and condition monitoring protocols. Addressing the issue of long-term operation and viability, accelerated aging was carried out on chlorosulfonated polyethylene (CSPE) / ethylene propylene rubber (EPR) insulations that were removed from harvested electrical cables. Cables were obtained as part of the Light Water Reactor and Sustainability (LWRS) Zion Harvesting Project in cooperation with Energy Solutions and the U.S. NRC. Zion NPP was in operation for 25 years prior to decommissioning before its 40-year operation license had expired.For the Boston Insulated Wire (BIW) manufactured EPR insulation with outer CSPE jackets, degradation was observed in mechanical properties with respect to time and temperature was observed. This degradation was impacted by the outer CSPE jacket as the increase in to the time to degradation at the same temperature was observed for EPR insulations with the outer CSPE jacket removed prior to aging. The correlation of IM and density to EAB also suggested that these parameters could also be used effectively in the estimates of activation energy with additional data. Arrhenius analysis on the mechanical degradation as measured by EAB for the two types of BIW EPR insulations with outer CSPE jackets estimated activation energies slightly different (BIW-A without outer CSPE jacket 1.58 eV, BIW-B with outer CSPE jacket 1.10 eV) than the 1.24 eV found in from analysis of EAB data found in Zion NPP BIW insulation documentation. These values were higher than those previously reported of 0.90 eV to 0.96 eV for CSPE and EPR materials in the literature and additional measurements are needed to further validate the increase in activation energy for these harvested materials and possible impact on remaining useful life estimation. Finally, FTIR analysis showed differences in the oxidation as measured by decrease in C-H bonds in EPR insulation and CSPE jackets and increase in C-O bonds in certain cases.

Davis, Sarah M.↗

Nondestructive Testing Research and Capabilities at Pacific Northwest National Laboratory

Pacific Northwest National Laboratory (PNNL) is a United States Department of Energy (DOE) multipurpose laboratory operated by Battelle Memorial Institute. The laboratory maintains several technical and scientific capabilities to meet the diverse and challenging needs of sponsors. The Applied Physics Group maintains significant capabilities of interest to the nondestructive testing (NDT) community and regularly collaborates with other technical disciplines to form unique teams in response to specific challenges. This article provides a brief overview of the capabilities of the Applied Physics Group and highlights some activities to demonstrate the scope of capabilities that span from applied research aimed at improving existing NDT methods or processes to more fundamental research efforts that are focused on developing tools to facilitate future paradigms of structural condition monitoring and awareness.

Nondestructive Testing, NDE, Nuclear Power, Phased↗

Progress in the Investigation of Nuclear Power Plant Cable Aging

The thousands of miles of polymer-insulated cables used for power, control and communications in nuclear power plants were originally qualified for forty years of plant operation. Continued use of cable in existing plants for periods much beyond their original qualified life will require a detailed understanding of cable degradation under plant operating conditions to assess and mitigate risk of continued use. The effect and relative importance of individual and combined environmental stresses including radiation, heat and moisture on reliable cable performance is essential to inform condition monitoring, lifetime prediction and required cable replacement planning. We present an overview and update of the nuclear cable aging program at the Pacific Northwest National Laboratory and the Oak Ridge National Laboratory supported by the U.S. Department of Energy, Office of Nuclear Energy, Light Water Reactor Sustainability program

Fifield, Leonard S.↗

PROGRESS IN THE INVESTIGATION OF NUCLEAR POWER PLANT CABLE AGING

The thousands of miles of polymer-insulated cables used for power, control and communications in nuclear power plants were originally qualified for forty years of plant operation. Continued use of cable in existing plants for periods much beyond their original qualified life will require a detailed understanding of cable degradation under plant operating conditions to assess and mitigate risk of continued use. The effect and relative importance of individual and combined environmental stresses including radiation, heat and moisture on reliable cable performance is essential to inform condition monitoring, lifetime prediction and required cable replacement planning. We present an overview and update of the nuclear cable aging program at the Pacific Northwest National Laboratory and the Oak Ridge National Laboratory supported by the U.S. Department of Energy, Office of Nuclear Energy, Light Water Reactor Sustainability program.

cable, insulation, polymer, EPR, XLPE, aging, degr↗

State of Electrical Cable Aging in U.S. Nuclear Power Plants

Nuclear energy has supplied one fifth of the electricity generation in the United States for the last thirty years, but headwinds for continued contribution of nuclear to the US energy mix include the aging state of existing plants and the challenge of remaining cost competitive with energy alternative such as natural gas. As an integral component of the power, control and safety operations of a nuclear power plant, electrical cables are a significant factor in both long term and resource-efficient plant operation. The cost and practical challenge of wholesale replacement of the thousands of miles of cables in each reactor make effective management of the existing cable inventory increasingly important as the cables age in service. Total generation costs for US nuclear reactors have increased in the last decade, due in part to safety and security upgrades. Passive, long-lived structures, systems and components may be subject to aging-related degradation, necessitating increase frequency of inspection and repair/replace decisions. Costs associated with cable aging management in long-term operation can be reduced with effective cable condition monitoring technology and sufficient understanding of material aging behavior. Technical basis for confidence in cable status can reduce the frequency of cable system inspections and align cable replacement decisions with physical need. Knowledge of cable remaining useful life can allow longer term cable maintenance planning and fewer unplanned outages. As methods for relating measurable key indicators of aging with cable status develop, industry has begun to demonstrate how informed cable aging management can help to minimize costs necessary for safe, long-term operation.

light water reactors, electrical cables, nuclear p↗

Integrated Risk-Informed Condition Based Maintenance Capability and Automated Platform: Technical Report 3

This project is a collaborative research effort between PKMJ Technical Services LLC, Idaho National Laboratory, and Public Service Enterprise Group (PSEG) Nuclear, LLC. The collaboration, led by PKMJ Technical Services LLC, is part of the industry Funding Opportunity Announcement (FOA) award under Advanced Nuclear Technology Development FOA #DE-FOA-0001817. The pilot demonstration focuses on the Circulating Water System (CWS), an important non-safety-related system that impacts the power generation capability of the plant site. Achieving riskinformed condition-based Predictive Maintenance (PdM) on the CWS will result in significant economic benefits, and the developed methodologies can also be applied to other plant systems. This approach supports an industry goal of ensuring that nuclear power generation remains a viable, economically competitive option in the energy market. Operation and Maintenance (O&M) costs include labor-intensive Preventive Maintenance (PM) programs that involve manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies as well as time-based replacement of assets, irrespective of condition. This project offers an alternative by focusing on riskinformed condition-based maintenance to reduce O&M costs while still maintaining plant health and safety. This report summarizes the progress made toward achieving a risk-informed condition-based maintenance approach. The research and development (R&D) activities presented in this report are associated with development of a nuclear digital platform application, integration of fault signature models, and automated work management processes. The fault signatures and Machine Learning (ML) models are key components in predictive analytics and are heavily leveraged to improve the insights received by existing plant process data sources. Availability of the analysis results within a centralized digital platform enhances efficiency by enabling automation of activities otherwise performed manually. Personnel are presented with enhanced information that can be used to evaluate plant status and risks. Utilizing the enhancements to data analytics supports automated responses, (i.e. issuance of work orders) to address developing equipment faults and thus preventing forced, unplanned shutdowns of components or systems. The R&D activities described within this report lay the foundation for developing and demonstrating a digital automated platform to centralize the implementation of condition monitoring and response to equipment faults. The digital automated platform is cloud-based and designed to enable improved efficiency of plant processes. The digital platform includes content related to maintenance optimization, fault signature analysis, and plant records, which can all be used to support efficiencies when located within a centralized digital platform. These efficiencies could be further enhanced when deployed through industry-wide deployment of the technology to improve insights and processes based upon economies of scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Demolition and Disposition of 209-E Critical Mass Laboratory - 12267

The 209-E Critical Mass Laboratory was constructed in 1960 to provide a heavy shielded reactor room where quantities of plutonium or uranium in solution could be brought to near-critical configurations under carefully controlled and monitored conditions. In the late 1980's, the responsible contractor, Pacific Northwest National Laboratory (PNNL), was directed by the Department of Energy (DOE) to prepare the facility for unoccupied status. The facility was demolished under a Removal Action Work Plan pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The funding for this project was provided by the American Recovery and Reinvestment Act (ARRA). The primary rooms of concern with regards to contamination in 209-E facility, which is over 9,000 square feet, are the criticality assembly room (CAR), the mix room, and the change room. The CAR contained two reactor hoods (HO-140 and HO-170), which each had a high efficiency particulate air (HEPA) filter system. The CAR contained 13 tanks ranging from 38 L (10 gal) to 401 L (106 gal). Tanks TK-109 and TK-110 are below grade, and were removed as part of this demolition and disposition remedy. Nonradiological and radiological hazardous substances were removed, decontaminated, or fixed in place, prior to demolition. Except for the removal of below grade tanks TK-109 and TK-110, the facility was demolished to slab-on-grade. PNNL performed stabilization and deactivation activities that included removal of bulk fissile material and chemicals, flushing tanks, stabilizing contamination within gloveboxes and hoods, and packaging and removing waste. The removal of the contaminated plutonium equipment and materials from the 209E facility presented a number of challenges similar in nature to those associated with the inventory reduction and cleanup activities at the Plutonium Finishing Plant. Although there were no bulk fissile materials or chemicals within the facility, there were residual radiological materials (isotopes of plutonium and americium) in the tanks and hoods. The complexity of the remedy was present because of the various configurations of the tanks and hoods, combined with the residual contaminants. Because of the weight and dimensional configuration, size reduction of the slab tanks, as well as removal and disposal of the different material used for moderation and absorption, were two examples of challenges that were resolved to complete the remedy. One of the key methods developed and implemented at the facility was the design and construction of a shroud to allow the cutting of the Pu contaminated tanks. The shroud design, development and implementation at the 209E Project was an example of enhanced work planning and task hazards analysis with worker involvement. This paper will present the lessons learned from the 209E facility inventory reduction activities including the shroud and other methodologies used. The initial Lessons Learned discussion for this project was scheduled for late January 2012. This facility is the first open-air demolition of a highly contaminated plutonium-contaminated facility accomplished by CH2M Hill under the Plateau Remediation Contract. The demolition was completed without spread of contamination to the workers and the surrounding area. As with any project of this complexity, there are significant accomplishments, as well as experience that can be applied to future demolition of plutonium-contaminated facilities on the Hanford Site. These experiences will be documented at a later date. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bare Fiber Bragg Gratings embedded into concrete buffer Supercontainer concept for nuclear waste storage [ANIMMA--2015-IO-337]

Nuclear power plants have been generating electricity for more than 50 years. In Belgium, 55% of the current energy supply comes from nuclear power. Providing for the safe storage of nuclear waste, including spent fuel (SF) and vitrified high level radioactive waste (HLW), remains an important challenge in the life cycle of nuclear fuel. In this context, the Belgian Agency for Radioactive Waste and Enriched Fissile Materials (ONDRAF/NIRAS) is investigating a reference conceptual design called the Supercontainer (SC) for the packaging of SF and HLW. This conceptual design is based on a multiple-barrier system consisting of a hermetically-sealed carbon steel overpack and a surrounding highly-alkaline concrete buffer. The first one is developed to retain the radionuclides. The two main functions of the buffer are (a) to create a high pH environment around the carbon steel overpack in order to passivate the metal surface and so to slow down the corrosion propagation during the thermal phase and (b) to provide a radiological shielding during the construction and the handling of the Supercontainer. A recent test has been performed to investigate the feasibility to construct the SC. This test incorporated several kinds of sensors including Digital Image Correlation (DIC), Acoustic Emission (AE), corrosion sensing techniques and optical fibers with and without fiber Bragg gratings (FBGs). In particular, several single-mode optical fibers with 4 mm long FBGs with different Bragg wavelengths and distributed along the optical fibers were used. For casting and curing condition monitoring, a number of gratings were incorporated inside the concrete buffer during the first stage of construction. Then other sensors were embedded near a heat source installed in the second stage to simulate the effects of heat generated by radioactive waste. The FBGs were designed to measure both temperature and strain effects in the concrete. To discriminate between these effects special packaging was used for some sensors that were installed very close to the unpackaged ones. Sensors placed in plastic tubes have reduced sensitivity to strain, while the ones inserted in metal tubes are only temperature sensitive and their readings can be directly compared with those obtained from thermocouples located nearby. In addition to monitoring temperature and strain behaviour, embedding also had as objective to determine the impact of the high alkaline environment on the silica fibers over a very long time. This article presents the preliminary results obtained with the different FBGs and provides recommendations for future improvement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inspection Technologies for Waste Containers at Canadian Nuclear Laboratories - 19429

To provide data for aging management programs, containers for different forms of nuclear waste, ranging from low-level waste to irradiated nuclear fuel, should be inspected. At Canadian Nuclear Laboratories, visual, ultrasonic, electromagnetic, and hybrid forms of non-destructive evaluation (NDE) are used for in situ inspection of carbon steel containers having various configurations, access issues, and material thickness. NDE applications tailored to the requirements of the task provide data for condition monitoring and operational assessments. The examples of fuel baskets stacked in concrete canisters and sheet metal containers arrayed in warehouses are illustrated here. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Luminosity measurement for lead-lead collisions at $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV in 2015 and 2018 at CMS

Measurements of the luminosity delivered to the CMS experiment during the lead-lead data-taking periods in 2015 and 2018 are presented for the first time. The collisions were recorded at a nucleon-nucleon center-of-mass energy of 5.02 TeV; the 2018 data sample is three times larger than the 2015 data sample. Three subdetectors are used: the pixel luminosity telescope, the forward hadron calorimeters, and the fast beam conditions monitor. The absolute luminosity calibration is determined using the van der Meer technique that relies on transverse beam separation scans. The dominant sources of uncertainty are the transverse factorizability of the bunch density profiles and, in 2015, the difference between the results obtained using various detectors. The total uncertainty in the integrated luminosity, including the stability of the calibrated subdetector response over time, amounts to 3.0% for 2015, 1.7% for 2018, and 1.6% for the combined data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Advanced Gate Drive for the SNS High Voltage Converter Modulator

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

43 PARTICLE ACCELERATORS↗

Incorporating Equipment Condition Assessment in Risk Monitors for Advanced Small Modular Reactors

Advanced small modular reactors (aSMRs) can complement the current fleet of large light-water reactors in the USA for baseload and peak demand power production and process heat applications (e.g., water desalination, shale oil extraction, hydrogen production). The day-to-day costs of aSMRs are expected to be dominated by operations and maintenance (O&M); however, the effect of diverse operating missions and unit modularity on O&M is not fully understood. These costs could potentially be reduced by optimized scheduling, with risk-informed scheduling of maintenance, repair, and replacement of equipment. Currently, most nuclear power plants have a “living” probabilistic risk assessment (PRA), which reflects the as-operated, as-modified plant and combine event probabilities with population-based probability of failure (POF) for key components. “Risk monitors” extend the PRA by incorporating the actual and dynamic plant configuration (equipment availability, operating regime, environmental conditions, etc.) into risk assessment. In fact, PRAs are more integrated into plant management in today’s nuclear power plants than at any other time in the history of nuclear power. However, population-based POF curves are still used to populate fault trees; this approach neglects the time-varying condition of equipment that is relied on during standard and non-standard configurations. Equipment condition monitoring techniques can be used to estimate the component POF. Incorporating this unit-specific estimate of POF in the risk monitor can provide a more accurate estimate of risk in different operating and maintenance configurations. This enhanced risk assessment will be especially important for aSMRs that have advanced component designs, which don’t have an available operating history to draw from, and often use passive design features, which present challenges to PRA. This paper presents the requirements and technical gaps for developing a framework to integrate unit-specific estimates of POF into risk monitors, resulting in enhanced risk monitors that support optimized operation and maintenance of aSMRs.

Advanced Small Modular Reactors↗

System and method for statistically monitoring and analyzing sensed conditions

A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.

97 MATHEMATICS AND COMPUTING↗

System and method for statistically monitoring and analyzing sensed conditions

A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.

47 OTHER INSTRUMENTATION↗