Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Degradation of FEP thermal control materials returned from the Hubble Space Telescope

After an initial 3.6 years of space flight, the Hubble Space Telescope was serviced through a joint effort with the NASA and the European Space Agency. Multi-layer insulation (MLI) was retrieved from the electronics boxes of the two magnetic sensing systems (MSS), also called the magnetometers, and from the returned solar array (SA-I) drive arm assembly. The top layer of each MLI assembly is fluorinated ethylene propylene (FEP, a type of Teflon). Dramatic changes in material properties were observed when comparing areas of high solar fluence to areas of low solar fluence. Cross sectional analysis shows atomic oxygen (AO) erosion values up to 25.4 mu m (1 mil). Greater occurrences of through-thickness cracking and surface microcracking were observed in areas of high solar exposure. Atomic force microscopy (AFM) showed increases in surface microhardness measurements with increasing solar exposure. Decreases in FEP tensile strength and elongation were measured when compared to non-flight material. Erosion yield and tensile results are compared with FEP data from the Long Duration Exposure Facility. AO erosion yield data, solar fluence values, contamination, micrometeoroid or debris impact sites, and optical properties are presented.

Zuby, Thomas M.↗

Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST &om contamination and the instruments from self-contamination.

Hansen, Patricia A.↗

Lessons Learned from the Hubble Space Telescope (HST) Contamination Control Program

Over the past two decades, the Hubble Space Telescope (HST) Contamination Control Program has evolved from a ground-based integration program to a space-based science-sustaining program. The contamination controls from the new-generation Scientific Instruments and Orbital Replacement Units were incorporated into the HST Contamination Control Program to maintain scientific capability over the life of the telescope. Long-term on-orbit scientific data has shown that these contamination controls implemented for the instruments, Servicing Mission activities (Orbiter, Astronauts, and mission), and on-orbit operations successfully protected the HST from contamination and the instruments from self-contamination.

Hansen, Patricia A.↗

Experiment to Characterize Aircraft Volatile Aerosol and Trace-Species Emissions (EXCAVATE)

The Experiment to Characterize Aircraft Volatile and Trace Species Emissions (EXCAVATE) was conducted at Langley Research Center (LaRC) in January 2002 and focused upon assaying the production of aerosols and aerosol precursors by a modern commercial aircraft, the Langley B757, during ground-based operation. Remaining uncertainty in the postcombustion fate of jet fuel sulfur contaminants, the need for data to test new theories of particle formation and growth within engine exhaust plumes, and the need for observations to develop air quality models for predicting pollution levels in airport terminal areas were the primary factors motivating the experiment. NASA's Atmospheric Effects of Aviation Project (AEAP) and the Ultra Effect Engine Technology (UEET) Program sponsored the experiment which had the specific objectives of determining ion densities; the fraction of fuel S converted from S(IV) to S(VI); the concentration and speciation of volatile aerosols and black carbon; and gas-phase concentrations of long-chain hydrocarbon and PAH species, all as functions of engine power, fuel composition, and plume age.

Anderson, B. E.↗

The BROOM system.

The Building Restoration Operations Optimization Model (BROOM) is a software product developed to assist in the restoration of major transport facilities in the event of an attack involving chemical or biological materials. As shown in Figure 3-1, the objective of this work is to replace a manual, paper-based data entry and tracking system with an electronic system that should be much less error-prone. It will also manage the sampling data efficiently and produce contamination maps in a more timely manner.

99 GENERAL AND MISCELLANEOUS↗

Well Design, Operation and Maintenance and Proactive Rehabilitation to Optimize Remediation Well Performance - 18605

Optimizing performance of extraction, injection and monitoring wells, which are integral components of groundwater remediation systems, result in lower life cycle costs and a higher probability of meeting project objectives. These wells provide the means to extract contaminated groundwater, inject reagents, treated water and clean water to create groundwater reaction/flushing zones, and to provide groundwater level, contaminant concentration and geochemical data. Initial costs associated with well installation and associated pipelines and treatment systems are significant project expenditures related to site remediation. However, the life cycle costs for wells are dominated by the long-term operation and maintenance (O and M) expenditures. Remediation wells are particularly susceptible to various types of fouling that impact well performance and, therefore, drive up operating costs. Simply defined, fouling is the result of any biological, geochemical or physical process that negatively impacts the intended performance of a remediation well. Fouling decreases well performance by effectively reducing hydraulic communication between the well and the surrounding formation. Oftentimes this occurs via clogging screens and/or gravel pack/formation pore space by bacterial or chemical byproducts and gases, which can lead to corrosion of metal components and spreading fouling deposits to pipelines and surface treatment systems. Ultimately, this results in reduced hydraulic performance in extraction and injection wells and result in erroneous water level and chemical parameter concentration measurements in monitoring wells. Remediation well fouling cannot be eliminated, and natural fouling processes are exacerbated by the installation and operation of remedial systems. Steps required to extend the life of remediation wells and to lower life cycle costs are discussed in this paper in order to establish the required approach to effective system management. These optimization approaches have been developed through years of operation and maintenance of complex large-scale plume remediation systems utilizing a variety of subsurface in-situ and ex-situ technologies. Remediation well performance can be improved by: - careful site characterization, - appropriate well design, - proper well installation and development, - thoughtful and adaptable operation and maintenance, - well performance maintenance tracking and, - proactive well rehabilitation. Clear understanding of the site hydro-stratigraphy and geochemical settings places constraints on the compatibility of well materials and the configurations of well screens. Proper well design, including collection and analysis (sieve/grain-size) of screen zone formation samples, assures that wells can be optimally installed, developed and redeveloped during well rehabilitation. Design considerations should include proper sizing of filter packs and well screens, casing/screen diameter, well material selection/compatibility, expected life/use, and well head configuration to allow for future access. Applying appropriate and effective well installation and development methods are of paramount importance and rely on a good understanding of site characteristics (e.g., geologic setting) as well as local drilling company expertise and experience. Different approaches to operation and maintenance can greatly affect the degree of fouling, these include limiting reagent concentrations, maintaining submerged well screens and filtering injection water to prevent the introduction of fouling enhancing constituents. Tracking well performance by monitoring changes in system operation and metrics such as specific capacity or injectivity for extraction and injection wells, respectively, or turbidity and chemical analyses for monitoring wells is key to identifying well maintenance issues early when well rehabilitation can be most effective. Proactive well rehabilitation can include mechanical brushing, surging and jetting, chemical treatment or other specialized approaches; however, the approach needs to be based on a site-specific understanding of the predominant fouling mechanisms. Collection and analyses of fouling deposits can provide guidance for selection of rehabilitation methods and chemicals that will be most effective. Application of these approaches have led to extended operational life for reagent injection wells, which can foul quickly, from months to years. Additionally, proper maintenance will often lead to increased and extended productivity of the well. For extraction wells, this translates to a higher sustainable yield, which means shorter cleanup times. Similarly, for injection wells, proper maintenance allows for the introduction of a greater volume of reagents over a shorter period, thus, shorter cleanup times that reduce overall project costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

External Contamination Control of Attached Payloads on the International Space Station

The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.

Soares, Carlos E.↗

Natural Gas Drilling near the Underground Nuclear Test Site of Rulison, Colorado - 19571

In 1969, the Project Rulison test was conducted in western Colorado using a nuclear device to stimulate natural gas production by fracturing low-permeability, gas-bearing rock. The presence of radionuclides (specifically tritium) in the produced gas persisted above acceptable levels, and the test was abandoned. Advances in hydrofracturing technology over the past 10-15 years have revolutionized the extraction of hydrocarbons from low-permeability formations, leading to a significant increase of drilling in the Rulison area. Drilling activity nearing the Rulison site has raised concerns that remnant radioactivity might be encountered. The site, now under the care of the US Department of Energy (DOE), is protected by a 16-hectare (40 acre) institutional control boundary (Lot 11) that prohibits drilling or extraction of materials below 1830 meters (6000 feet) within the lot boundary. Drilling within 0.8 kilometer (0.5 mile) of the site requires a hearing before the Colorado Oil and Gas Conservation Commission. DOE recommends that gas developers adopt a conservative, staged drilling approach, allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. The staged approach calls for collecting data from wells away from the site before drilling closer. For instance, the wells 1.2 kilometer (0.75 mile) west of the site did not encounter any unexpected geologic conditions and now have 8 years of production without encountering any detonation-related radionuclides. The next set of wells would be 0.8 kilometer (0.5 mile) west of the site. This sequential method drills first at locations with a low probability of encountering contamination and then moves closer. This process protects public safety while allowing the collection of additional data to confirm that contamination has not migrated beyond the 16-hectare (40-acre) institutional control boundary. The staged drilling approach was simulated with a modeling effort that estimates the current extent of contamination and the potential for production-induced contaminant migration to nearby wells. The model incorporates geologic data from nearby wells and was calibrated to production data from both the reentry well production testing (1970-1971) and the wells 1.2 kilometer (0.75 mile) from the site that began producing in 2010. The geologic data include both sand/shale distribution statistics as well as the tendency of hydrofractures to preferentially propagate east and west due to the regional stress field. The model results indicate that it is unlikely that wells near the site would ever encounter site-related radionuclides. (authors)

03 NATURAL GAS↗

A Data-driven Phytotechnology Framework for Identification and Remediation of Leached-Metals-Contaminated Soil Near Coal Ash Impoundments

This project developed and evaluated advanced remote sensing and machine learning approaches to identify, monitor, and address environmental contamination associated with coal combustion residual (CCR) impoundments and landfills at coal-fired power plants. In Phase I, historical and multi-temporal Sentinel-2 satellite imagery, groundwater monitoring data, and environmental variables were integrated to detect vegetation stress potentially caused by toxic metal leaching from coal ash disposal sites. Multiple vegetation and biophysical indices were analyzed to determine their effectiveness in identifying abnormal vegetation growth patterns linked to contamination. Results from case studies conducted at coal ash–impacted power plant sites in North Carolina and Virginia demonstrated that satellite-based vegetation monitoring can serve as an effective early indicator of environmental stress associated with metals such as arsenic, cadmium, cobalt, lead, lithium, radium, and thallium.

01 COAL, LIGNITE, AND PEAT↗

STS-1 mission contamination evaluation approach

The space transportation system 1 mission will be the first opportunity to assess the induced environment of the orbiter payload bay region. Two tools were developed to aid in this assessment. The shuttle payload contamination evaluation computer program was developed to provide an analytical tool for prediction of the induced molecular contamination environment of the space shuttle orbiter during its onorbit operations. An induced environment contamination monitor was constructed and tested to measure the space shuttle orbiter contamination environment inside the payload bay during ascent and descent and inside and outside the payload bay during the onorbit phase. Measurements are to be performed during the four orbital flight test series. Measurements planned for the first flight are described and predicted environmental data are discussed. The results indicate that the expected data are within the measurement range of the induced environment contamination monitor instruments evaluated, and therefore it is expected that useful contamination environmental data will be available after the first flight.

Jacobs, S.↗

ROSAT PSPC and HRI Observations of Supernova Remnant G292.0+1.8

The supernova remnant G292.0+1.8 was observed by the ROSAT PSPC for 18 ksec as part of this grant. Considerable effort was put into the analysis of the PSPC spectra. The major work went into nonequilibrium ionization joint spectral fits with the Einstein SSS and EXOSAT ME data which indicated that the two spatial regions of this remnant (a central bar and a plateau region covering a larger extent) had similar abundances, but different excitation conditions (temperature and ionization state), an important conclusion, if true. Unfortunately as this work was being finished, new ASCA data revealed the presence of a previously unknown, spectrally hard X-ray source near the center of the remnant which contaminated the SSS and ME data and as a consequence made our detailed spectral analysis done up until then un-publishable. We searched for evidence of this hard source in the PSPC data both spectrally and using timing searches (for a pulsar), but found nothing significant. ROSAT HRI data were also obtained on this remnant. These data were compared to the Einstein HRI data to search for evidence of spectral variations with position and possible expansion of the X-ray remnant. One feature in the remnant appears to have changed in brightness although it is not clear what is the cause of the change. No evidence for the hard ASCA source was apparent in the HRI data.

Hughes, John P.↗

Multi-Faceted Approach to Evaluate Discharge Locations at a FUSRAP Site - 18421

Following the completion of a Soil and Groundwater Remedial Investigation by USACE at a FUSRAP site located in Nassau County, New York, groundwater data indicated the presence of contaminant source(s) that had not been identified. As a result, a targeted investigation was undertaken to understand how materials were handled and disposed of at a site located in Nassau County, Long Island, New York. The FUSRAP site is a 4.3-hectare (10.5-acre) site encompassing three parcels which had historically been utilized as a nuclear materials manufacturing facility (e.g., cores, slug, and fuel elements) for reactors used in both research and electric power generation in early 1950's until late 1960's; however, the targeted investigation was on the southern-most parcel known as the '70 Property' (the Site). The 70 Property contained a building that was used for atomic fuel-element manufacturing from 1958 until 1966 under license to the Atomic Energy Commission (AEC), and involved the use of natural, enriched, and depleted uranium as well as lesser amounts of thorium. The major contaminants of concern are tetrachloroethene, nickel, uranium and thorium. During the RI, significant sources of contamination were not found in Site soils despite records indicating that chemicals and radionuclides had been disposed of on the property. In addition, downgradient groundwater data indicated a source(s) on the 70 Property that could not be identified by known sources on other the other FUSRAP parcels or from adjacent sites. This conclusion was further supported following development of groundwater contaminant transport and flow models. The main objective of the targeted investigation was to evaluate the potential discharge points on the 70 Property that may have been utilized for liquids waste disposal. However, several challenges existed including 1) lack of building construction details; 2) historical changes to Site building and property; 3) the use of the Site by various tenants; and 4) the commingling of Site contaminants with impacts from multiple sources. To overcome these challenges, historic documents/reports with information about the handling and disposal of liquid wastes were reviewed to evaluate quantities, contents and locations of waste disposal. Thereafter, an investigation was undertaken that included geophysical surveys; pipe tracing and video inspection; in-situ smoke and water testing; installation of test trenches and soil borings; and, sampling sludge residuals, soils and water within the various drainage structures that were located. This paper describes the multi-faceted investigation approach that was utilized to overcome the challenges faced during the investigation as well as insights into the waste disposal practices of the time period and the findings of the investigation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of Airborne Contaminants on Fuel Cell Performance and Durability

The impact of contaminants on fuel cell performance was examined to document air filter specifications (prevention) and devise recovery procedures (maintenance) that are effective at the system level. Eight previously undocumented airborne contaminants were selected for detailed studies and characterization data was used to identify operating conditions that intensifying contamination effects. The use of many and complementary electrochemical, chemical and physical characterization methods and the derivation of several mathematical models supported the formulation of contamination mechanisms and the development of recovery procedures. The complexity of these contamination mechanisms suggests a shift to prevention and generic maintenance measures. Only two of the selected contaminants led to cell voltage losses after injection was interrupted. Proposed recovery procedures for calcium ions, a component of road de-icers, dessicants, fertilizers and soil conditioners, were either ineffective or partly effective, whereas for bromomethane, a fumigant, the cell voltage was recovered to its initial value before contamination by manipulating and sequencing operating conditions. However, implementation for a fuel cell stack and system remains to be demonstrated. Contamination mechanisms also led to the identification of membrane durability stressors. All 8 selected contaminants promote the formation of hydrogen peroxide, a known agent that can produce radicals that attack the ionomer and membrane molecular structure whereas the dehydrating effect of calcium ions on the ionomer and membrane increases their brittleness and favors the creation of pinholes under mechanical stresses. Data related to acetylene, acetonitrile and calcium ions are emphasized in the report.

33 ADVANCED PROPULSION SYSTEMS↗

Modular Open System Architecture for Reducing Contamination Risk in the Space and Missile Defense Supply Chain

To combat contamination of physical assets and provide reliable data to decision makers in the space and missile defense community, a modular open system architecture for creation of contamination models and standards is proposed. Predictive tools for quantifying the effects of contamination can be calibrated from NASA data of long-term orbiting assets. This data can then be extrapolated to missile defense predictive models. By utilizing a modular open system architecture, sensitive data can be de-coupled and protected while benefitting from open source data of calibrated models. This system architecture will include modules that will allow the designer to trade the effects of baseline performance against the lifecycle degradation due to contamination while modeling the lifecycle costs of alternative designs. In this way, each member of the supply chain becomes an informed and active participant in managing contamination risk early in the system lifecycle.

Seasly, Elaine↗

Laboratory Activities

This chapter summarizes the laboratory activities performed by PNNL’s Vadose Zone Characterization Project in support of the Tank Farm Vadose Zone Program, led by CH2M HILL Hanford Group, Inc. The results of these studies are contained in numerous reports (Lindenmeier et al. 2002; Serne et al. 2002a, 2002b, 2002c, 2002d, 2002e; Lindenmeier et al. 2003; Serne et al. 2004a, 2004b; Brown et al. 2005, 2006a, 2007; Serne et al. 2007) and have generated much of the data reported in Chapter 22 (Geochemistry-Contaminant Movement), Appendix G (Geochemistry-Contaminant Movement), and Cantrell et al. (2007, SST WMA Geochemistry Data Package – in preparation). Sediment samples and characterization results from PNNL’s Vadose Zone Characterization Project are also shared with other science and technology (S&T) research projects, such as those summarized in Chapter 12 (Associated Science Activities).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cold-welding test environment

A flight test was conducted and compared with ground test data. Sixteen typical spacecraft material couples were mounted on an experimental research satellite in which a motor intermittently drove the spherical moving specimens across the faces of the fixed flat specimens in an oscillating motion. Friction coefficients were measured over a period of 14-month orbital time. Surface-to-surface sliding was found to be the controlling factor of generating friction in a vacuum environment. Friction appears to be independent of passive vacuum exposure time. Prelaunch and postlaunch tests identical to the flight test were performed in an oil-diffusion-pumped ultrahigh vacuum chamber. Only 50% of the resultant data agreed with the flight data owing to pump oil contamination. Identical ground tests were run in an ultrahigh vacuum facility and a ion-pumped vacuum chamber. The agreement (90%) between data from these tests and flight data established the adequacy of these test environments and facilities.

Wang, J. T.↗

Contamination on LDEF sources: Distribution and history

An overview description of contamination sources from preflight, mission, and post flight environments is presented. Examples of contamination events and processes from each stage of the LDEF mission are given. Infrared (IR) and x-ray photoelectron spectroscopy (XPS) data characterizing some of the contaminant films will be shown. Property changes on surfaces due to contaminant films, and post-deposition changes in the contaminant films due to the space environment will be reported.

Pippin, H. Gary↗

Analysis of the Electronic Crosstalk Effect in Terra MODIS Long-Wave Infrared Photovoltaic Bands Using Lunar Images

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the space-view port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27-30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the in-band and out-of-band contribution to the signal contamination for each detector in bands 27-30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27- 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

Wilson, Truman↗