Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

Testing of Compact Bolted Fasteners with Insulation and Friction-Enhanced Shims for NCSX

The fastening of the National Compact Stellarator Experiment's (NCSX) modular coils presented a number of engineering and manufacturing challenges due to the high magnetic forces, need to control induced currents, tight tolerances and restrictive space envelope. A fastening method using high strength studs, jack nuts, insulating spacers, bushings and alumina coated shims was developed which met the requirements. A test program was conducted to verify the design. The tests included measurements of flatness of the spacers, determination of contact area, torque vs. tension of the studs and jack nuts, friction coefficient tests on the alumina and G-10 insulators, electrical tests, and tension relaxation tests due to temperature excursions from room temperature to liquid nitrogen temperatures. This paper will describe the design and the results of the test program.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SCALE Modeling of the Fast Spectrum Heat Pipe Reactor

As part of the severe accident analysis collaboration with Sandia National Laboratories (SNL) and the Nuclear Regulatory Commission (NRC), SCALE models were developed for a fast-spectrum heat pipe reactor. These models were based on the Idaho National Laboratory (INL) Design A concept, which is an alternative design to the Los Alamos National Laboratory (LANL) Special Purpose Reactor (SPR), also known as the Megapower reactor. The model contains 1,134 heat pipes, surrounded by hexagonal fuel elements, with a potassium working fluid; the fuel is UO 2 with 19.75 wt% 235 U enrichment. The model contains axial beryllium oxide (BeO) reflectors above and below the active fuel region along with a radial alumina reflector containing 12 B 4 C control drums. The center of the core is left unfueled to make room for two shutdown control rods, one annular and one solid. The active region of the core was discretized into twenty axial and five radial zones to analyze spatial variations in power and burnup. Infinite lattice unit cell sensitivity studies were used to perform verification between the SCALE and INL models. The eigenvalue results agreed well with the reported results to within roughly 50 percent mille (pcm). Full-core model verification was performed by analyzing system eigenvalues with differing configurations of control drum and shutdown rod positions. These full core results all had eigenvalue differences less than 310 pcm. Control drum and shutdown rod worths were also compared, with differences of 3.2% or less. Using the verified model, the isotopic inventory and decay heat, as well as temperature feedback coefficients, were calculated and provided to SNL as input to the MELCOR severe accident code to analyze potential releases from this class of reactor. The results of the MELCOR analysis are provided in a different report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety-Related Instrumentation and Control Upgrade Pilot Project: NUREG- 0711 Process Development, Planning and Analysis Activities, and Lessons Learned

Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper presents the development execution of the HFE Program through completion of the Planning and Analysis Phase as defined by NUREG-0711 as well as HFE lessons learned.

99 GENERAL AND MISCELLANEOUS↗

The effectiveness of TRIS and ammonium buffers in glass dissolution studies: a comparative analysis

Abstract Selecting appropriate buffers is crucial for evaluating the chemical durability of glass under controlled conditions such as in the EPA 1313 test designed to measure elemental release as a function of pH. The efficacy of two alkali-metal free buffers, TRIS (NH 2 C(CH 2 OH) 3 ) and ammonium chloride—ammonia (NH 3 /NH 4 Cl), was investigated during EPA 1313 testing of a simulated Hanford low-activity waste borosilicate glass in the alkaline regime (pH 8.5–10.5) at varying temperatures (RT, 40 °C, and 60 °C). While both buffers maintained the desired pH at room temperature, and up to 40 °C, the effectiveness of TRIS decreased at elevated temperatures, particularly at pH 10.5. Although 11 B NMR showed evidence of TRIS-B complexation, its effect on the rate of elemental release was found to be negligible under the test conditions. With ammonium buffer, the release of alkali cations was slightly elevated when compared to the same conditions with TRIS at early time points.

36 MATERIALS SCIENCE↗

Measurement and Analysis of Dose Rate Distribution in the Seismic Base-Isolation pit of the Electron Linac Oncology Facility - Paper 87

Recently electric linac oncology facilities incorporating seismic base-isolation structure have become very popular in Japan to prevent strong impact to the equipment by the earthquakes. When the boundary of the controlled area is set below the base-isolated foundations, additional shielding of iron plate is needed and the cost for shielding sometimes increases up to $1 M Since no one usually accesses underneath the treatment room, except short maintenance period for base-isolation structure, it is reasonable to set the boundary around the downstairs room (pit) by fence. However, it is very difficult to estimate the dose rate of new boundary by using the simple shielding calculation method, because of rotating gantry head and effect of scattering radiation in the base-isolation floor. In this study detail calculations by using Monte-Carlo calculation code MCNP5 have been performed to find out the practical shielding design. To be more specific, investigation for the complicated behavior of photons in the 'pit' have been performed by the analysis, i.e. (1) How much can we reduce the thickness of additional iron plate?, (2) Which angle of the beam direction will influence the most to the dose rate at the new boundary?, (3) Which component of the radiation is dominant at the new boundary? We also verified the calculated results by the measurement. We have performed the analysis of the behavior of photons in the pit and found out no additional iron shielding was necessary, which carried out an extreme reduction of costs. The main contribution to the dose rate at the boundary was scattered photons in the case of 0- degree beam direction. Good agreement between calculated and measured results were obtained, and passed the examination by the authority. It is concluded that the Monte-Carlo calculation code MCNP5 is very effective for the optimistic design of the electron linac oncology facilities incorporating seismic base-isolation structure. (authors)

43 PARTICLE ACCELERATORS↗

Facile synthesis of QD-anchored composite particles with magnetite cluster cores ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs)

Highlights: ► Triple layered Fe{sub 3}O{sub 4}/SiO{sub 2}/QDs were designed as fluorescent magnetic nanocomposites. ► Magnetite cluster-embedded silica exhibited strong and controllable magnetism. ► Effective conjugation between QDs and magnetic silica occurred at pH3. - Abstract: Magnetism-controlled fluorescent composite particles ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs) were prepared as QD-anchored silica nanoparticles with magnetite cluster cores. First, citrate-capped magnetites (C-Fe{sub 3}O{sub 4}) were prepared by the co-precipitation method and subsequently complexed with 3-aminopropyl-trimethoxysilane (APTMS) at room temperature, consequently leading to the formation of magnetite clusters (A-{sup n}Fe{sub 3}O{sub 4}) with alkoxy terminated interfaces. The sol–gel reaction between A-{sup n}Fe{sub 3}O{sub 4} and tetraethoxysilane (TEOS) produced the core-shell {sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}. The resulting core-shell particles exhibited superparamagnetic properties and controllable magnetism simply by adjusting the thickness of nonmagnetic silica layer. After then, amine-terminated {sup n}Fe{sub 3}O{sub 4}@SiO{sub 2} (NH{sub 2}–{sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}) was conjugated with carboxy quantum dots (QDs) using an EDC coupling agent. The QD conjugation with NH{sub 2}–{sup n}Fe{sub 3}O{sub 4}@SiO{sub 2} of lower pH exhibited the higher photoluminescence (PL) intensity, and the resulting composite particles ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs) can be a useful biomedical agent. This chemical strategy can be further applied to prepare the core-shell magnetic nanostructure with various oxide layers for specific applications.

36 MATERIALS SCIENCE↗

Design and thermomechanical properties of a γ' precipitate-strengthened Ni-based superalloy with high entropy γ matrix

A novel Ni-based superalloy was designed with γ' precipitate strengthening, controlled γ/γ' lattice misfit and high configurational entropy of the γ matrix for improved high temperature performance up to 800 degrees C. The alloy contains nano-sized γ' precipitates, MC and other grain boundary carbides. Three variants of the alloy were fabricated using vacuum induction melting, a computational-based homogenization cycle for reducing solidification segregation, and thermomechanical processing steps of forging followed by hot rolling to produce plates from which ASTM standard test specimens were extracted. Tensile testing at room temperature and elevated temperatures up to 800 degrees C revealed superior yield stress when compared to Nimonic 105 with good tensile strength values. Furthermore, the three alloys are machinable with maximum stresses comparable to standard practices as determined using deformation mechanisms maps obtained from Gleeble testing and EBSD analysis. Due to the composition of the experimental alloys falling outside the typical range used to populate thermodynamic databases, differences in phase predictions and related temperatures were observed between the experiment and Thermo-Calc predictions. Here, the γ' forming elements Ti and Nb had a similar effect on the γ' precipitates and indirectly contributed to changing the entropy of the γ matrix. Based on the results of this study, these alloys have the potential for use at 800 degrees C in energy structural applications. Definitions related to this novel class of alloys are discussed.

36 MATERIALS SCIENCE↗

Design of Graphene/Ionic Liquid Composites for Carbon Capture

Pore size is a crucial factor impacting gas separation in porous separation materials, but how to control the pore size to optimize the separation performance remains a challenge. Here, we propose a design of graphene/ionic liquid composites with tunable slit pore sizes, where cations and anions of ionic liquids are intercalated between graphene layers. By varying the sizes of the ions, we show from first-principles density functional theory calculations that the accessible pore size can be tuned from 3.4 to 6.0 Å. Grand canonical Monte Carlo simulations of gas sorption find that the composite materials possess high CO 2 uptake at room temperature and 1 bar (up to ~8.5 mmol/g). Further simulations of the sorption of gas mixtures reveal that high CO 2 /N 2 and CO 2 /CH 4 adsorption selectivities can be obtained when the accessible pore size is <5 Å. This work suggests a new strategy to achieve tunable pore sizes via the graphene/IL composites for highly selective CO 2 /N 2 and CO 2 /CH 4 adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformation T-Cup: A new multi-anvil apparatus for controlled strain-rate deformation experiments at pressures above 18 GPa

A new multi-anvil deformation apparatus, based on the widely used 6-8 split-cylinder, geometry, has been developed which is capable of deformation experiments at pressures in excess of 18 GPa at room temperature. In 6-8 (Kawai-type) devices eight cubic anvils are used to compress the sample assembly. In our new apparatus two of the eight cubes which sit along the split-cylinder axis have been replaced by hexagonal cross section anvils. Combining these anvils hexagonal-anvils with secondary differential actuators incorporated into the load frame, for the first time, enables the 6-8 multi-anvil apparatus to be used for controlled strain-rate deformation experiments to high strains. Testing of the design, both with and without synchrotron-X-rays, has demonstrated the Deformation T-Cup (DT-Cup) is capable of deforming 1–2 mm long samples to over 55% strain at high temperatures and pressures. To date the apparatus has been calibrated to, and deformed at, 18.8 GPa and deformation experiments performed in conjunction with synchrotron X-rays at confining pressures up to 10 GPa at 800 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO2 MONITORING FOR DEMAND CONTROLLED VENTILATION IN COMMERCIAL BUILDINGS

Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used, in a process called demand-controlled ventilation, to automatically modulate rates of outdoor air ventilation. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. Demand controlled ventilation is most often used in spaces with highly variable and sometime dense occupancy. Reasonably accurate CO{sub 2} measurements are needed for successful demand controlled ventilation; however, prior research has suggested substantial measurement errors. Accordingly, this study evaluated: (a) the accuracy of 208 CO{sub 2} single-location sensors located in 34 commercial buildings, (b) the accuracy of four multi-location CO{sub 2} measurement systems that utilize tubing, valves, and pumps to measure at multiple locations with single CO{sub 2} sensors, and (c) the spatial variability of CO{sub 2} concentrations within meeting rooms. The field studies of the accuracy of single-location CO{sub 2} sensors included multi-concentration calibration checks of 90 sensors in which sensor accuracy was checked at multiple CO{sub 2} concentrations using primary standard calibration gases. From these evaluations, average errors were small, -26 ppm and -9 ppm at 760 and 1010 ppm, respectively; however, the averages of the absolute values of error were 118 ppm (16%) and 138 ppm (14%), at concentrations of 760 and 1010 ppm, respectively. The calibration data are generally well fit by a straight line as indicated by high values of R{sup 2}. The Title 24 standard specifies that sensor error must be certified as no greater than 75 ppm for a period of five years after sensor installation. At 1010 ppm, 40% of sensors had errors greater than {+-}75 ppm and 31% of sensors has errors greater than {+-}100 ppm. At 760 ppm, 47% of sensors had errors greater than {+-}75 ppm and 37% of sensors had errors greater than {+-}100 ppm. A significant fraction of sensors had errors substantially larger than 100 ppm. For example, at 1010 ppm, 19% of sensors had an error greater than 200 ppm and 13% of sensors had errors greater than 300 ppm. The field studies also included single-concentration calibration checks of 118 sensors at the concentrations encountered in the buildings, which were normally less than 500 ppm during the testing. For analyses, these data were combined with data from the calibration challenges at 510 ppm obtained during the multi-concentration calibration checks. For the resulting data set, the average error was 60 ppm and the average of the absolute value of error was 154 ppm. Statistical analyses indicated that there were statistically significant differences between the average accuracies of sensors from different manufacturers. Sensors with a 'single lamp single wavelength' design tended to have a statistically significantly smaller average error than sensors with other designs except for 'single lamp dual wavelength' sensors, which did not have a statistically significantly lower accuracy. Sensor age was not consistently a statistically significant predictor of error.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic flow stress of pure polycrystalline aluminum: Pressure-shear plate impact experiments and extension of dislocation-based modeling to large strains

The dynamic thermo-mechanical behavior of pure aluminum has attracted renewed interest lately due to experimental observations of an anomalous increase in Hugoniot Elastic Limit (HEL) at incipient plasticity and elevated temperatures in polycrystalline pure metals. In context of current dislocation-mediated plasticity models for metals, this increase in dynamic strength is indicative of a transition in the rate controlling mechanism for dislocation glide from being thermally assisted to phonon-drag restricted due to increase in phonon viscosity at elevated temperatures. Though these studies have helped to shed light on these important mechanisms operative in FCC metals at incipient plasticity, the extent to which they contribute to flow stress, particularly at larger strains, remains unclear. Here, we address these questions through a combined experimental and modeling effort focused on investigating the evolution of dynamic flow stress in polycrystalline aluminum using experimental data gathered from a series of combined pressure-and-shear plate impact (PSPI) experiments designed to reveal the flow stress of pure aluminum at strain rates ~ 10 5 /s, plastic strains of up to 40% and temperatures ranging from room to 866 K. In all cases, the flow stress of aluminum, as inferred from the measured transverse particle velocity histories at the free surface of an elastic tungsten carbide target plate, reveals saturation with increasing plastic strains at stress levels that decrease with increasing test temperatures. Numerical simulations are performed to correlate the experimentally observed temperature and strain rate dependence of flow stress at small and large plastic strains using the Austin-McDowell dislocation-mediated plasticity model parametrized to normal plate impact experiments conducted in an earlier study by Zaretsky and Kanel (2012). Extensions to the model are made to better represent dynamic behavior of pure aluminum at larger plastic strains as observed in elevated temperature split Hopkinson Pressure bar (SPHB) experiments of Samanta (1971) and Lindholm and Yeakly (1965), and the combined pressure-and-shear plate-impact experiments conducted in the present study. The main theoretical extension to the Austin-McDowell model made in this paper is the introduction of a new rate- and temperature- dependent dynamic recovery function, which can potentially allow for an effective reduction in the rate of accumulation of dislocations at large plastic strains. The numerical predictions of the revised and re-calibrated plasticity model are brought into agreement with the experimental observations, correlating sufficiently well with dynamic yield stress at incipient plasticity and the flow stress levels at larger plastic strains, plastic strain rates in the range 10 3 – 10 6 /s, and elevated temperatures up to near melt. The model, in concert with the experimental measurements, suggests that at incipient plasticity the rate governing mechanism for plastic flow is phonon-drag restricted dislocation glide, whereas, at higher magnitudes of plastic strain, it transitions to stress-assisted thermally activated glide. The transition between these two rate governing mechanisms is controlled by the evolution of dislocations throughout the deformation process.

36 MATERIALS SCIENCE↗

P3HT-Based Polymer Solar Cells with 8.25% Efficiency Enabled by a Matched Molecular Acceptor and Smart Green-Solvent Processing Technology

Here, a novel molecular acceptor of TrBTIC (2,7,12-tris((2-(3-oxo-2,3-dihydroinden- 1-ylidene)malononitrile-7-benzothiadiazole-2-)truxene) is designed by attaching the 2-(3-oxo-2,3-dihydroinden-1-ylidene)malononitrilebenzothiadiazole (BTIC) electron-deficient unit to an electron-rich truxene core. TrBTIC has excellent solubility in common solvents and features good energy level matching with poly(3-hexylthiophene) (P3HT). Interestingly, P3HT can be readily dissolved in warm 1,2,4-trimethylbenzene (TMB), a green solvent, but crystallizes slowly with long-term aging in TMB at room temperature. A prephase separation can thus occur before active blend film deposition, and the separation degree can be easily controlled by varying the aging time. After 40 min of aging, the resulting active blend has the most appropriate phase separation with uniform nanowires, which forms favorable interpenetrating networks for exciton dissociation and charge transport. As a result, the device performance is improved from 6.62% to 8.25%. Excitingly, 8.25% is a new record for P3HT-based solar cells. The study not only provides an efficient nonfullerene acceptor for matching P3HT donors but also develops a promising processing technology to realize high-performance P3HT-based polymer solar cells with an efficiency over 8%.

36 MATERIALS SCIENCE↗

The inverse problems of wing panel manufacture processes

It is shown that inverse problems of steady-state creep bending of plates in both the geometrically linear and nonlinear formulations can be represented in a variational formulation. Steady-state values of the obtained functionals corresponding to the solutions of the problems of inelastic deformation and springback are determined by applying a finite element procedure to the functionals. Optimal laws of creep deformation are formulated using the criterion of minimizing damage in the functionals of the inverse problems. The formulated problems are reduced to the problems solved by the finite element method using MSC.Marc software. Currently, forming of light metals poses tremendous challenges due to their low ductility at room temperature and their unusual deformation characteristics at hot-cold work: strong asymmetry between tensile and compressive behavior, and a very pronounced anisotropy. We used the constitutive models of steady-state creep of initially transverse isotropy structural materials the kind of the stress state has influence. The paper gives basics of the developed computer-aided system of design, modeling, and electronic simulation targeting the processes of manufacture of wing integral panels. The modeling results can be used to calculate the die tooling, determine the panel processibility, and control panel rejection in the course of forming.

36 MATERIALS SCIENCE↗

Light–matter coupling in large-area van der Waals superlattices

Two-dimensional (2D) crystals have renewed opportunities in design and assembly of artificial lattices without the constraints of epitaxy. However, the lack of thickness control in exfoliated van der Waals (vdW) layers prevents realization of repeat units with high fidelity. Recent availability of uniform, wafer-scale samples permits engineering of both electronic and optical dispersions in stacks of disparate 2D layers with multiple repeating units. In this study, we present optical dispersion engineering in a superlattice structure comprising alternating layers of 2D excitonic chalcogenides and dielectric insulators. By carefully designing the unit cell parameters, we demonstrate greater than 90% narrow band absorption in less than 4 nm of active layer excitonic absorber medium at room temperature, concurrently with enhanced photoluminescence in square-centimetre samples. These superlattices show evidence of strong light–matter coupling and exciton–polariton formation with geometry-tuneable coupling constants. Our results demonstrate proof of concept structures with engineered optical properties and pave the way for a broad class of scalable, designer optical metamaterials from atomically thin layers.

2D Crystals↗

Biologically Cooling the Planet: A BRISK Approach that Directly Connects the Ground to Deep Space

Climate change is a grave threat to our ability to thrive and prosper on Earth. Accumulation of greenhouse gases in the atmosphere stifle the Earth’s ability to cool itself, which leads to a rise of the average temperature – Global warming. The planetary cooling is exclusively radiative – thermal radiation escapes into cold outer space via a flux of photons at the low-infrared range. The penetration of these photons through Earth’s atmosphere is dictated by atmospheric transparency, which, serendipitously possesses a window centered around the peak of the Plank spectrum for a black body at about room temperature – the average temperature of Earth. This window spanning about 8 --13 μm wavelengths allows most of the photons in this range to escape into the Cosmos carrying our planet’s heat away. The efficiency of this outer heat flux – and thus planet’s cooling ability – can be controlled via emissivity – a function of wavelength which multiplies the fundamental Plank spectrum of a black body at a given temperature. In the presence of non-trivial atmospheric transparency it can be shown that radiative cooling can be enhanced with properly “designed” emissivity function. For the last 100 years, or so, people have been looking into ways to engineer materials to take advantage of such enhancement for various cooling applications, from making ice to cool clothes, and substantial progress has been achieved, including cooling in direct sunlight. The beauty if this approach is that it is entirely passive – no energy input is required. The objective of this project was to investigate whether biological systems possess such advanced cooling capacity, developed via millennia of evolution, to enhance plant’s adaptation to a hot environment, to increase cooling capability, and possibly modulate spectral emissivities on short or long time scales. We wanted to know if BRISK (Biological Radiative Sky Cooling) occurs and to what extent. It is unknown whether biological systems can perform this "spectral redistribution." It is reasonable to expect, however, that they might: in particular, desert plants under high heat stress and arid conditions might evolve this mechanism in order to maintain a tolerable internal temperature. Our intended approach was twofold: extensive literature search and supporting experimental investigations on select plants. We obtained the answers from the former, while the latter proved to be more complicated to perform with required accuracy in the timespan/budget of a small seedling project. After one year of research, we concluded that among the plant species studied there seem to be no evidence of BRISK, but it’s not the end of the story. Our planet’s biosphere is immense, and the evolution is continuing. With our preliminary results and a better understanding of what to look for further discoveries await, considering the accelerated pace of infrared imaging and spectroscopy technology development, from microscopic to satellite-based studies of plants and canopies. In the end, Earth’s energy balance is ultimately tied to radiative cooling so that further investigation into this problem is directly tied to solving the Climate Change challenge.

54 ENVIRONMENTAL SCIENCES↗

The M. D. Anderson proton therapy system

Purpose: The purpose of this study is to describe University of Texas M. D. Anderson proton therapy system (PTC-H) including the accelerator, beam transport, and treatment delivery systems, the functionality and clinical parameters for passive scattering and pencil beam scanning treatment modes, and the results of acceptance tests. Methods: The PTC-H has a synchrotron (70-250 MeV) and four treatment rooms. An overall control system manages the treatment, physics, and service modes of operation. An independent safety system ensures the safety of patients, staff, and equipment. Three treatment rooms have isocentric gantries and one room has two fixed horizontal beamlines, which include a large-field treatment nozzle, used primarily for prostate treatments, and a small-field treatment nozzle for ocular treatments. Two gantry treatment rooms and the fixed-beam treatment room have passive scattering nozzles. The third gantry has a pencil beam scanning nozzle for the delivery of intensity modulated proton treatments (IMPT) and single field uniform dose (SFUD) treatments. The PTC-H also has an experimental room with a fixed horizontal beamline and a passive scattering nozzle. The equipment described above was provided by Hitachi, Ltd. Treatment planning is performed using the Eclipse system from Varian Medical Systems and data management is handled by the MOSAIQ system from IMPAC Medical Systems, Inc. The large-field passive scattering nozzles use double scattering systems in which the first scatterers are physically integrated with the range modulation wheels. The proton beam is gated on the rotating range modulation wheels at gating angles designed to produce spread-out-Bragg peaks ranging in size from 2 to 16 g/cm{sup 2}. Field sizes of up to 25x25 cm{sup 2} can be achieved with the double scattering system. The IMPT delivery technique is discrete spot scanning, which has a maximum field size of 30x30 cm{sup 2}. Depth scanning is achieved by changing the energy extracted from the synchrotron (energy can be changed pulse to pulse). The PTC-H is fully integrated with DICOM-RT ION interfaces for imaging, treatment planning, data management, and treatment control functions. Results: The proton therapy system passed all acceptance tests for both passive scattering and pencil beam scanning. Treatments with passive scattering began in May 2006 and treatments with the scanning system began in May 2008. The PTC-H was the first commercial system to demonstrate capabilities for IMPT treatments and the first in the United States to treat using SFUD techniques. The facility has been in clinical operation since May 2006 with up-time of approximately 98%. Conclusions: As with most projects for which a considerable amount of new technology is developed and which have duration spanning several years, at project completion it was determined that several upgrades would improve the overall system performance. Some possible upgrades are discussed. Overall, the system has been very robust, accurate, reproducible, and reliable. The authors found the pencil beam scanning system to be particularly satisfactory; prostate treatments can be delivered on the scanning nozzle in less time than is required on the passive scattering nozzle.

43 PARTICLE ACCELERATORS↗

New insights into designing metallacarborane based room temperature hydrogen storage media

Metallacarboranes are promising towards realizing room temperature hydrogen storage media because of the presence of both transition metal and carbon atoms. In metallacarborane clusters, the transition metal adsorbs hydrogen molecules and carbon can link these clusters to form metal organic framework, which can serve as a complete storage medium. Using first principles density functional calculations, we chalk out the underlying principles of designing an efficient metallacarborane based hydrogen storage media. The storage capacity of hydrogen depends upon the number of available transition metal d-orbitals, number of carbons, and dopant atoms in the cluster. These factors control the amount of charge transfer from metal to the cluster, thereby affecting the number of adsorbed hydrogen molecules. This correlation between the charge transfer and storage capacity is general in nature, and can be applied to designing efficient hydrogen storage systems. Following this strategy, a search for the best metallacarborane was carried out in which Sc based monocarborane was found to be the most promising H{sub 2} sorbent material with a 9 wt.% of reversible storage at ambient pressure and temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗