At least 415 records · Page 23

Innovation in Radiological Security, Part 2 of 2 – Insights into Developing a Cloud-hosted Security Technology

A Sentry Remote Monitoring System (Sentry-RMS) is a stand-alone security system that provides detection, assessment, and communication of priority alarms as an additional means of thwarting internal and external threats to sites that maintain radiological material. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform is an optional feature of the Sentry-RMS that relays priority alarm information to the identified response stakeholders. Sentry-SECURE is hosted in a cloud environment that abstracts the data owner’s and data consumer’s platforms to allow for greater information sharing. This promotes situational awareness amongst authorized users and enables future innovation among modern response platforms. When securely architecting a cloud solution such as this, the use of design paradigms can be an effective tool to increase the accuracy and reliability of cyber- and information-security-related decisions made throughout the development process. This approach also supports the categorization of design considerations into three levels: industry concepts, project approaches, and data protections for digital processes. Industry concepts consist of the notional underpinnings that guide or motivate a security process, system, or design but often lack any tangible attributes. Project approaches represent decisions made during the design and development process to prioritize a solution, method, or practice above another that may provide a comparable functional output but lacks a desired security benefit. Data protections for digital processes represent the selection, integration, and implementation of specific controls for a given asset. This paper will explore specific examples of how Sentry-SECURE has been designed to account for considerations at each of these three levels, while balancing the operational intent of the platform with the security enhancements necessary to maintain data integrity, availability, and confidentiality.

assessment, RMS, security, physical, cloud, Cyber ↗

Secure and Resilient Operations Using Open-Source Distributed Systems Platform (OpenDSP)

The goal of this project is to identify and address cybersecurity gaps by developing a multi-layer multi-channel cyber-physical defense and survival mechanism for operating distribution networks with high penetration of solar / inverter-based resource (IBR) / distributed energy resource (DER). The proposed security enhancements are built upon the distributed framework and solution architecture for both information technology (IT) and operational technology (OT) systems. The technical solutions consist of two composite functionalities and six layers: proactive defense (vulnerability assessment, communication protection, and attack detection, as layers 1-3), and adaptive self-healing (attack-resilient control, adaptive recovery, and resilient survival, as layers 4-6). These layers, built on and extended from DHS CISA Cyber Framework, establish an integrated and robust cybersecurity framework for operating large-scale distribution networks.

14 SOLAR ENERGY↗

Enhancing Early Systems R&D Capabilities with Systems —Theoretic Process Analysis

Systems engineering today faces a wide array of challenges, ranging from new operational environments to disruptive technological — necessitating approaches to improve research and development (R&D) efforts. Yet, emphasizing the Aristotelian argument that the “whole is greater than the sum of its parts” seems to offer a conceptual foundation creating new R&D solutions. Invoking systems theoretic concepts of emergence and hierarchy and analytic characteristics of traceability, rigor, and comprehensiveness is potentially beneficial for guiding R&D strategy and development to bridge the gap between theoretical problem spaces and engineering-based solutions. In response, this article describes systems–theoretic process analysis (STPA) as an example of one such approach to aid in early-systems R&D discussions. STPA—a ‘top-down’ process that abstracts real complex system operations into hierarchical control structures, functional control loops, and control actions—uses control loop logic to analyze how control actions (designed for desired system behaviors) may become violated and drive the complex system toward states of higher risk. By analyzing how needed controls are not provided (or out of sequence or stopped too soon) and unneeded controls are provided (or engaged too long), STPA can help early-system R&D discussions by exploring how requirements and desired actions interact to either mitigate or potentially increase states of risk that can lead to unacceptable losses. This article will demonstrate STPA's benefit for early-system R&D strategy and development discussion by describing such diverse use cases as cyber security, nuclear fuel transportation, and US electric grid performance. Together, the traceability, rigor, and comprehensiveness of STPA serve as useful tools for improving R&D strategy and development discussions. In conclusion, leveraging STPA as well as related systems engineering techniques can be helpful in early R&D planning and strategy development to better triangulate deeper theoretical meaning or evaluate empirical results to better inform systems engineering solutions.

42 ENGINEERING↗

Sequential Service Restoration for Unbalanced Distribution Systems and Microgrids

The resilience and reliability of modern power systems are threatened by increasingly severe weather events and cyber-physical security events. An effective restoration methodology is desired to optimally integrate emerging smart grid technologies and pave the way for developing self-healing smart grids. In this paper, a sequential service restoration (SSR) framework is proposed to generate restoration solutions for distribution systems and microgrids in the event of large-scale power outages. The restoration solution contains a sequence of control actions that properly coordinate switches, distributed generators, and switchable loads to form multiple isolated microgrids. The SSR can be applied for three-phase unbalanced distribution systems and microgrids and can adapt to various operation conditions. Mathematical models are introduced for three-phase unbalanced power flow, voltage regulators, transformers, and loads. Furthermore, the SSR problem is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the modified IEEE 123 node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Security of DERs and Grid Edge Technologies [Slides]

Distributed energy resources (DERs) offer significant value for incorporating diverse generation technologies and improving reliability. They also present a new set of cybersecurity challenges. The move of generation to the grid edge can also mean more distributed control systems and expanded communication networks, resulting in an increase in attack surface. This presentation will discuss definitions and essential terms related to DERs; developments and deployment trends for DERs; recent cyber attacks on operational technology and industrial systems; cyber risk arising from distributed grid resources; and ways in which standards may help mitigate some of these risks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HP in Cybersecurity: CyOTE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently detect adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. Unlike the approach taken with commercial security solutions, CyOTE seeks to tie anomalies in cyber operations to a cyber-attack. By stringing together multiple techniques in the OT environment, AOOs can identify attack campaigns with ever decreasing impacts. The CyOTE methodology applies fundamental concepts of perception and comprehension to a universe of knowns and unknowns increasingly disaggregated into observables, anomalies, and triggering events. MITRE’s ATT&CK® Framework for Industrial Control Systems (ICS) is used as a common lexicon to identify a set of triggering events related to three Use Cases – Alarm Logs, Human-Machine Interface (HMI), and Remote Logins – which together account for 87 percent of the techniques commonly used by adversaries. The CyOTE methodology is also appropriate for OT-related anomalies perceived outside the three Use Cases, such as through the energy system itself.

99 GENERAL AND MISCELLANEOUS↗

Cyber-Informed Engineering (CIE) Benefits Quantification: Recommendations for Consideration

Cyber-Informed Engineering (CIE) integrates engineering principles into the design, development, and operation of cyber-physical systems (CPS) to mitigate or eliminate the impact of cyber-enabled attacks. In July 2024, Idaho National Laboratory (INL) engaged MITRE researchers to investigate methods for systematically measuring the benefits of CIE implementation. This included evaluating the success and outcomes of CIE, identifying and quantifying the value of early adoption, and determining the business justification for its implementation, especially in existing infrastructure. MITRE reviewed existing methods in engineering and cybersecurity to understand how organizations prioritize security investments, considering their strengths, weaknesses, and relevance to CIE stakeholders. Based on this analysis, MITRE proposed potential approaches for quantifying CIE benefits and provided recommendations for INL's consideration.

42 ENGINEERING↗

IBR Digital Supply Chain Gap Analysis and Recommendations

The adoption of clean energy technologies, including solar photovoltaics, continues to introduce non-traditional stakeholders to the operations and planning of the electric system. Stakeholders such as manufacturers, vendors, owners, aggregators, and others are enabling the adoption, integration, and optimum operations of solar technologies at accelerated rates. Inverters form the foundation of many digitally controlled energy sources for clean energy technologies, including Solar, Battery Energy Storage Systems, Hybrid Systems, and Hydrogen Fuel Cells. Their supply chain is complex, a series of microchips, electronic switches and other components making up its primary functions. The complexity of this space and the growing digitization associated with these components can create supply chain cyber risks. One measure to mitigate cybersecurity attacks is proper digital supply chain security. The U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), in partnership with the Cybersecurity, Energy, Security, and Emergency Response (CESER) office, is hosting a workshop to bring together solar vendors and services providers to discuss digital supply chain security for solar systems and challenges and opportunities in the transitioning to a fully domestic supply chain for solar energy in the U.S. This workshop will support the Securing Solar for the Grid (S2G) and Energy Cyber Sense program activities. During the workshop, industry experts and researchers from DOE National Laboratories will discuss the current solar supply chain landscape and the transition to domestic manufacturing of solar components in the U.S. Tools and techniques to better manage and secure the digital supply chain of solar devices and systems will be discussed.

cybersecurity↗

Security Architecture for Microgrid Integration

The purpose of this document is to present cyber security risk considerations and mitigations for community microgrids. The mitigations discussed herein specifically focus on cyber security technical requirements for the De-centralized Autonomous Community Controller (DAC) as part of the SECURE project’s technology development effort. These requirements also consider the associated security implementation challenges involved with the decentralized characteristics of microgrids where upstream communications to utility security management functions are lost. These security recommendations and technical requirements may be used by microgrid implementers and technology vendors to specify the security design of the microgrid systems and their components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mixed-Initiative Cyber Security: Putting humans in the right loop

In recent years, organizations and their computer infrastructures have grown intertwined in complex relationships through mergers, acquisitions, reorganizations, and cooperative service delivery. Defensive actions and policy changes by one organization may have far-reaching negative consequences on its partner organizations. Human-only or machine-only approaches are insufficient. The former are slow but highly adaptable, while the latter are fast but highly specialized. In either case, humans retain the ultimate responsibility for the actions of their automated systems. Deploying automated defenses does not absolve humans of their inherent responsibility. We believe the solution lies in mixed-initiative defense unifying the complementary qualities of both human- and machine-based approaches. We describe the Cooperative Infrastructure Defense (CID), a new cyber-defense paradigm employing complex-adaptive swarm intelligence, logical rational agents, and human insight to enable collaborative cyber defense among cooperating organizations in an infrastructure setting. CID takes a mixed-initiative approach to infrastructure defense where teams of humans and software agents defend cooperating organizations in tandem, sharing insights and solutions without violating proprietary boundaries. CID will help create security policy via dialogue between humans and agents, foster a collaborative problem-solving environment, and increase human situational awareness and influence through visualization and shared control. CID will provide a foundation for building trust between humans and agents within and between organizations.

97 MATHEMATICS AND COMPUTING↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impact of cyberattacks on safety and stability of connected and automated vehicle platoons under lane changes

Connected and automated vehicles (CAVs) offer a huge potential to improve the operations and safety of transportation systems. However, the use of smart devices and communications in CAVs introduce new risks. CAVs would leverage vehicle to vehicle (V2V) and vehicle to infrastructure (V2I) communication, thus providing additional system access points compared to traditional systems. Automation makes these systems more vulnerable and increases the consequences of cyberattacks. This study utilizes an infrastructure-based communication platform consisting of cooperative adaptive cruise control and lane control advisories developed by the authors to perform cyber risk assessment of CAVs. The study emulates three types of cyberattacks (message falsification, dedicated denial of service, and spoofing attacks) in a representative traffic environment consisting of multiple CAV platoons and lane change events to analyze the safety and stability impacts of the cyberattacks. Simulation experiments using VISSIM reveals that traffic stream and CAV string is unstable under all three types of cyberattacks. The worst case is represented by the message falsification attack. Increases in volatility are observed over a no attack case, with variations increasing by an average of 43%–51% along with an increase of over 3000 crash conflicts. Similarly, lane change crash conflicts are observed to be more severe compared to rear end crash conflicts, showing a higher probability of severe injuries. Further, the case of slight cyberattack on a single CAV also creates significant disruption in the traffic stream. Analysis of variance (ANOVA) reveals the statistical significance of the results. Furthermore, these results pave the way for future design of secure systems from a monitoring perspective.

97 MATHEMATICS AND COMPUTING↗

Detection and Analysis of Threats to the Energy Sector: DATES

This report summarizes Detection and Analysis of Threats to the Energy Sector (DATES), a project sponsored by the United States Department of Energy and performed by a team led by SRI International, with collaboration from Sandia National Laboratories, ArcSight, Inc., and Invensys Process Systems. DATES sought to advance the state of the practice in intrusion detection and situational awareness with respect to cyber attacks in energy systems. This was achieved through adaptation of detection algorithms for process systems as well as development of novel anomaly detection techniques suited for such systems into a detection suite. These detection components, together with third-party commercial security systems, were interfaced with the commercial Security Information Event Management (SIEM) solution from ArcSight. The efficacy of the integrated solution was demonstrated on two testbeds, one based on a Distributed Control System (DCS) from Invensys, and the other based on the Virtual Control System Environment (VCSE) from Sandia. These achievements advance the DOE Cybersecurity Roadmap [DOE2006] goals in the area of security monitoring. The project ran from October 2007 until March 2010, with the final six months focused on experimentation. In the validation phase, team members from SRI and Sandia coupled the two test environments and carried out a number of distributed and cross-site attacks against various points in one or both testbeds. Alert messages from the distributed, heterogeneous detection components were correlated using the ArcSight SIEM platform, providing within-site and cross-site views of the attacks. In particular, the team demonstrated detection and visualization of network zone traversal and denial-of-service attacks. These capabilities were presented to the DistribuTech Conference and Exhibition in March 2010. The project was hampered by interruption of funding due to continuing resolution issues and agreement on cost share for four months in 2008. This resulted in delays in finalizing agreements with commercial partners, and in particular the Invensys testbed was not installed until December 2008 (as opposed to the March 2008 plan). The project resulted in a number of conference presentations and publications, and was well received when presented at industry forums. In spite of some interest on the part of the utility sector, we were unfortunately not able to engage a utility for a full-scale pilot deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cyber-Informed Engineering (CIE) Workbook: End-of-Train (EoT) / Head-of-Train (HoT) Communications

This workbook presents a vulnerability (CVE-2025-1727 ) found in train applications and guides a digital risk assessment and mitigation analysis and application of Cyber-Informed Engineering principles to mitigate the potential consequences and ultimately the hazard through the engineering discipline because of exploiting this vulnerability. Workshop participants are encouraged to use the workbook to capture insights and lessons learned. The workbook guides the participant to: • Understand the HE communication vulnerability • Map digital threats to physical consequences • Use bowtie analysis to illustrate both “security” and “engineering” barriers • Apply CIE principles to ensure that even if communications are compromised, the physical engineered system still behaves safely. • Produce an actionable set of engineered and infosec controls for implementation

42 - ENGINEERING↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network Slicing for Federated Learning in Operational Technology Environment

Industrial Control Systems (ICS) and Supervisory Control and Data Acquisition (SCADA) environments are essential to modern infrastructure, facing challenges in ensuring low-latency, high-throughput communication while mitigating cyber threats. This paper presents a framework integrating Federated Learning (FL) and network slicing with Quality of Service (QoS) to enable real-time monitoring without disrupting OT operations. Leveraging digital twin technology and Network Function Virtualization (NFV), the architecture supports predictive analytics and Industry 4.0 requirements. FL facilitates decentralized model training, preserving data privacy and scalability, though it introduces potential throughput constraints. Network slicing addresses this by creating dedicated virtualized segments optimized for performance and security. Advanced fault tolerance at the container and instance levels enhances system reliability. The proposed architecture ensures high throughput, low latency, and secure orchestration for real-time anomaly detection in OT networks. Performance evaluations validate its efficiency in throughput, deployment, and learning accuracy, providing a robust foundation for future ICS automation and data-driven decision-making.

Delgado, Brian G. Rodiles [University of Texas at ↗