Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control of electric power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

Model predictive control for active insulation in building envelopes

Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind power costs driven by innovation and experience with further reductions on the horizon

The costs of wind power have declined to levels on par with or below those of conventional sources in many parts of the world. Wind power has become one of the fastest-growing sources of new electricity generation. We take stock of wind power cost evolution over the past 20 years, review methodologies commonly used for cost assessment, discuss the potential for continued cost reduction, and identify anticipated cost and value drivers. Our scope includes both onshore and offshore wind technologies. We draw from a vast body of literature on these topics to highlight key trends, approaches, and limitations. Furthermore, we discuss strategies for wind power assets to enhance their marginal economic value to the broader power system and consumers. We identify a myriad of factors that are expected to influence the future cost and value of wind power, including siting, project scale, turbine size, operational synergies, commodity prices, advancements in turbine technologies, enhanced management of the wind resource, and novel control technologies that provide value for the electricity grid. Because the common methods for forecasting future costs each have their own strengths and weaknesses, we find the best insights are elicited from a combination of methods. Overall, researchers and analysts anticipate further sizable cost reductions for onshore and offshore wind. Midrange forecasts for levelized cost of energy in 2050 are generally between $20 and $30/MWh for onshore wind and $40 and $60/MWh for offshore wind, a reduction to approximately half of today's levels. Optimistic forecasts anticipate these levels as early as 2030.

17 WIND ENERGY↗

Light Water Reactor Sustainability Program Plant Modernization Technical Program Plan for FY 2021

This report presents the Technical Program Plan for FY 2019 for the Department of Energy Light Water Reactor Sustainability Program – Plant Modernization research pathway. A summary of the vision and strategy is provided to explain how this program addresses key issues and barriers for modernizing instrumentation and control technologies and infrastructure in domestic nuclear power plants. The report describes the pilot projects that have been formulated to develop and validate enabling technologies over the next several years that will result in digital alternatives to the legacy analog II&C systems in place today. This will allow much needed modernization of these systems to address reliability and obsolescence problems, as well as serve as a platform for substantial operational improvement. The report further describes key project resources and cooperative relationships, including the Electric Power Research Institute, the Nuclear Energy Institute )NEI), the Institute of Nuclear Power Operations (INPO), the IFE Halden Reactor Project, the Nuclear Regulatory Commission, and industry suppliers, that are instrumental to the success of the program. The report also lists the schedule for all program products, including the titles and report numbers for all published reports under this program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Power management for hybrid electric vehicles

A system and method for power management of hybrid electric vehicles is provided. In some implementations, a plug-in series hybrid electric vehicle may include an engine, a motor/generator (MG), a traction motor, an energy storage device, and a controller. The controller is coupled to the engine and the MG to control operation of the engine and the MG such that a state-of-charge (SOC) of the energy storage device tracks a dynamic reference SOC profile during a trip and an average engine power (AEP) is maintained above a threshold. In some instances, maintaining AEP above a threshold supports emission control of the vehicle.

Le, Dat Duc↗

Intelligent Control of Thermal Energy Storage in the Manufacturing Sector for Plant-Level Grid Response

Industrial facilities are seeking new strategies that help in providing savings mechanisms for demand charges. Demand charges are the charges incurred by industrial facilities as a result of power usage. Thermal energy storage has advanced significantly with lots of new applications, garnering the interest of many industrial facilities. These applications could be used to shave the industrial facilities’ peak electric demand and reduce their demand charges. This paper aims to demonstrate the efficacy of thermal energy storage in reducing demand charges and highlight new developments in the integration of smart control systems with thermal energy storage. The study compares energy consumption and peak demand for a facility equipped with and without thermal energy storage tanks using a fixed schedule for charging and discharging. Additionally, the paper examines the impact of incorporating a smart controller to determine when to charge and discharge the tank based on the facility’s real-time power usage and a given setpoint. The results indicate cost savings from the use of thermal energy storage tanks under two proposed scenarios, reflected in the reduced cost of power consumption for the studied facility. The incorporation of a smart controller with the thermal energy storage tank in the facility studied could provide estimated savings of 3.3% per year of power consumption charges, without considering the contribution of any incentives. The estimated savings provided by the fixed schedule scenario are 2.7% per year.

25 ENERGY STORAGE↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response: Preprint

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVDl model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

ADVANCED PROPULSION SYSTEMS↗

Modelling and analysis of nuclear reactor system coupled with a liquid metal battery

Traditionally, nuclear power plants in the U.S. provide baseload power to the power grid because they have less flexibility for ramping their output power than natural gas peaking plants. However, achieving climate goals to reduce the consumption of fossil‐based natural gas places pressure on nuclear power plants and other power generators to ramp up their power output to balance grid generation with demand. This paper presents the modelling and performance analysis of a nuclear reactor system (NRS) coupled to a liquid‐metal battery (LMB) to improve its dynamic response and enable its black start capability. The NRS and LMB thermal behaviour are modelled in Dymola, while the electrical dynamics of the LMB and power grid are modelled in RTDS‐RSCAD. Both simulation platforms are coupled and share their thermal and electrical data using a Transmission Control Protocol/Internet Protocol (TCP/IP) communication protocol. The dynamic performance of the NRS‐LMB integration is tested on the IEEE 9 bus, which demonstrates its ability to respond and provide frequency and voltage regulation. The black start capability of the NRS‐LMB is also evaluated by simulating a grid outage and using the LMB to supply the auxiliary loads required to bring the NRS back online as soon as possible. The results show that coupling an NRS to an LMB improves the system dynamic performance and enables it to black start after being disconnected from the grid for several days.

25 ENERGY STORAGE↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Site Energy Management System Platform Development

A site energy management system is a critical component of future high-power EV charging hubs. It monitors and supervises all inter-hub operations, coordinates grid interactions, and implements energy management strategies and load-sharing controls at various levels and time scales. This report provides a comprehensive high-level overview and guidelines on the essential elements of such energy management systems. These elements primarily focus on the core functions, architecture, and monitoring aspects of site energy management. The core functions define the grid services and operational objectives that a charging hub is expected to provide and achieve. The architectural section investigates the coordination between hub assets, different control schemes, and their potential benefits and drawbacks. Lastly, the report discusses the needs, types, and functionalities of a monitoring and visualization system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Edge Visibility: Gaps and a Road Map

Behind-The-Meter (BTM) resources at the grid edge are rapidly becoming an important component of the electric grid, requiring a substantial reconfiguration of traditional grid practices, such as policy changes, market redesign, and infrastructure upgrades. This adjustment is challenged by the fact that, by definition, grid edge elements are not easily observable by grid control entities. Increasing the visibility of these resources is therefore an important goal, one that is experiencing much research and discussion by various power system stakeholders. For example, policy makers are analyzing the tradeoffs of using grid edge meters to impose charges on grid edge electricity generation. System operators, such as the Midcontinent Independent System Operator (MISO) in the United States, can identify visibility information on the electrical location and the size of the grid edge resources as a critical consideration across the transmission-and-distribution (T&D) spectrum. This article summarizes the challenges and needs of grid entities resulting from the introduction of grid edge resources as well the gaps in the extant grid edge visibility frameworks.

behind-the-meter↗

Guanidinium-Assisted Surface Matrix Engineering for Highly Efficient Perovskite Quantum Dot Photovoltaics

Metal halide perovskite quantum dots (Pe-QDs) are of great interest in new-generation photovoltaics (PVs). However, it remains challenging in the construction of conductive and intact Pe-QD films to maximize their functionality. Herein, a ligand-assisted surface matrix strategy to engineer the surface and packing states of Pe-QD solids is demonstrated by a mild thermal annealing treatment after ligand exchange processing (referred to as “LE-TA”) triggered by guanidinium thiocyanate. The “LE-TA” method induces the formation of surface matrix on CsPbI 3 QDs, which is dominated by the cationic guanidinium (GA+) rather than the SCN-, maintaining the intact cubic structure and facilitating interparticle electrical interaction of QD solids. Consequently, the GA-matrix-confined CsPbI 3 QDs exhibit remarkably enhanced charge mobility and carrier diffusion length compared to control ones, leading to a champion power conversion efficiency of 15.21% when assembled in PVs, which is one of the highest among all Pe-QD solar cells. Additionally, the “LE-TA” method shows similar effects when applied to other Pe-QD PV systems like CsPbBr 3 and FAPbI 3 (FA = formamidinium), indicating its versatility in regulating the surfaces of various Pe-QDs. This work may afford new guidelines to construct electrically conductive and structurally intact Pe-QD solids for efficient optoelectronic devices.

36 MATERIALS SCIENCE↗