Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Managing Cyber Supply Chain Risk for Renewable Energy Technologies

On July 1, 2021, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) hosted a virtual workshop facilitated by the National Renewable Energy Laboratory (NREL). Cybersecurity supply chain experts, researchers, and leaders in government and industry came together to share information on current and future challenges in securing emerging technologies and technical architecture. From a cybersecurity perspective, we need to move from a cybersecurity approach that focuses principally on legacy asset owners to one that incorporates more emphasis on end-point device manufacturers and third-party integrators. Cybersecurity for the global digital supply chain for manufacturers of consumer end-point devices—such as smart solar inverters and smart electric vehicle (EV) chargers—will be critical to the future cyber health of the grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber Informed Engineering Cie Analysis Tool

Main Benefits: • Collaborate on assessment via the web and access and share assessments on your mobile device. • Helps you maximize your cybersecurity investment and resources • Saves you significant time and money by eliminating the requirement to research each government and industry standard in order to understand your cybersecurity posture • Contains easy to follow, step by step instructions to guide you through the process of identifying the cybersecurity posture of your organization • Provides a place to begin with cybersecurity improvement and a way to prioritize your tasks and budgets. • Covers all major cyber relevant topic areas for a comprehensive assessment of your organization’s cybersecurity posture. • Dives deep into the details of each topic area. • Contributes to the organization's risk management and decision-making process • Highlights vulnerabilities and gaps in your organization's IT and control systems. • Raises awareness and facilitates discussion on cybersecurity within your organization • Educates the controls system community on cyber security.

Hansen, Barry [Idaho National Laboratory (INL), Id↗

Advanced Reactor Cyber Analysis and Development Environment (ARCADE) for System-Level Design Analysis

Cybersecurity is a persistent concern to the safety and security of Nuclear Power Plants (NPPs), but has lacked data-driven, evidence-based research. Rigorous cybersecurity analysis is critical for the licensing of advanced reactors using a performance-based approach. One tool that enables cybersecurity analysis is modeling and simulation. The nuclear industry makes extensive use of modeling and simulation throughout the decision process but lacks a method to incorporate cybersecurity analysis with existing models. To meet this need, the Advanced Reactor Cyber Analysis and Development Environment (ARCADE) was developed. ARCADE is a suite of publicly available tools that can be used to develop emulations of industrial control system devices and networks and integrate those emulations with physics simulators. This integration of cyber emulations and physics models enables rigorous cyber-physical analysis of cyber-attacks on NPP systems. This report provides an overview of key considerations for using ARCADE with existing physics models and demonstrates ARCADE’s capabilities for cybersecurity analysis. Using a model of the Small Modular Advanced High Temperature Reactor (SmAHTR), ARCADE was able to determine the sensitivity of the primary heat exchangers (PHX) to coordinated cyber-attacks. The analysis determined that while the PHX’s failures cause disruption to the reactor, they did not cause any safety limits to be exceeded because of the plant design, including passive safety features. Further development of ARCADE will enable rigorous, repeatable, and automated cyber-physical analysis of advanced reactor control systems. These efforts will also help reduce regulatory uncertainty by presenting similar types of cybersecurity analyses in a common format, driving standard approaches and reporting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber Halo Innovation Research Program (CHIRP) Student Research Report: Program Analysis

The Cybersecurity and Space Systems Research Program (CHIRP) conducted multi-year, mission-focused research addressing emerging cybersecurity challenges affecting space and ground systems. Students from California State University San Bernardino (CSUSB), University of Texas El Paso (UTEP), and California State University Dominguez Hills (CSUDH) conducted structured research, developed proof-of-concept demonstrations, participated in applied cybersecurity training, and collaborated with Space Systems Command (SSC), academic, and industry partners. This report documents the research questions, methodologies, findings, demonstrations, and student contributions associated with each cohort. It also summarizes the program’s workforce-development outcomes, including applied cybersecurity training, professional certifications, technical credentials, and partnerships with organizations such as CT Cubed, Inc. and ISC2. Collectively, CHIRP strengthened the space-cybersecurity workforce pipeline and produced research and prototype efforts that may inform future cybersecurity assessments, test and evaluation activities, cyber-range development, acquisition planning, operational training, and mission-assurance initiatives.

McKenzie, Penny L.↗

Improving the Cyber and Physical Security Posture of the Electric Sector (Final Report)

Cooperative electric utilities represent an integral part of the larger electric grid and are part of the nation’s critical infrastructure. The National Rural Electric Cooperative Association (NRECA) has a unique relationship with approximately 900 cooperatively owned and operated electric utilities and engaged in a program with the Department of Energy (DOE) to promote a culture of cybersecurity and resiliency within the electric cooperative community. The Rural Cooperative Cybersecurity Capabilities (RC3) Program, funded under a Cooperative Agreement with DOE (Project DE-OE-0000807), focused on improving the cybersecurity and resiliency capabilities of small and mid-sized electric distribution cooperatives. This segment of electric utilities faces many challenges, but also embraces a culture of cooperation that presents opportunities. A customized approach is needed to reach these utilities – one that emphasizes collaboration, more focused and personalized training, use of trusted and familiar experts that can be deployed as needed, software security services that require limited in-house cybersecurity expertise, and shared resource models that enable access to more expensive cybersecurity options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Zero Trust Strategies for Chemical, Biological, Radiological, and Nuclear Detection Systems: D.1 Cyber Scenarios

The evolving landscape of cybersecurity necessitates a paradigm shift to a Zero Trust (ZT) model, which assumes breaches and continuously verifies trust. This approach reshapes how trust boundaries are established, focusing on identities, devices, networks, applications, and data, rather than solely relying on perimeter defenses such as firewalls. Central to this transformation is the National Institute of Standards and Technology's (NIST) Special Publication 800-207, outlining the Zero Trust Architecture (ZTA), along with Executive Order 14028, which mandates federal agencies to adopt ZT principles. Complementary to these efforts, the Cybersecurity and Infrastructure Security Agency (CISA) developed the Zero Trust Maturity Model (ZTMM), providing a framework with five pillars and three cross-cutting capabilities to guide agencies toward enhanced cybersecurity maturity. In support of these initiatives, the DHS Countering Weapons of Mass Destruction Office (CWMD) is applying ZT principles to secure Chemical, Biological, Radiological, and Nuclear (CBRN) detection systems. Recognizing the diverse deployment models and network connectivity of these systems—from stationary, non-networked units to mobile, cloud-connected devices—the Pacific Northwest National Laboratory (PNNL) is developing cybersecurity scenarios specifically for CBRN environments. These scenarios examine various configurations and technological capabilities, offering insights into the application of ZTMM pillars in enhancing the security postures of CBRN devices. The cybersecurity scenarios presented by PNNL are hypothetical, crafted to explore theoretical situations and stimulate discussion on the potential use or compromise of CBRN detection systems in varied contexts. These narratives are illustrative and do not reference any real events or actual networks. Instead, they employ generalized reference models to highlight concepts and potential issues within CBRN security, focusing on how Zero Trust strategies can be adapted to address these challenges effectively.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Cyber-Resilience Risk Management Architecture for Distributed Wind

Distributed wind is an electric energy resource segment with strong potential to be deployed in many applications, but special consideration of resilience and cybersecurity is needed to address the unique conditions associated with distributed wind. Distributed wind is a strong candidate to help meet renewable energy and carbon-free energy goals. However, care must be taken as more systems are installed to ensure that the systems are reliable, resilient, and secure. The physical and communications requirements for distributed wind mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity risk management for distributed wind systems specifically. This research develops an architecture for the consideration of cyber risks associated with distributed wind systems. The architecture takes into account the configurations, challenges, and standards for distributed wind to create a risk-focused perspective that considers of threats, vulnerabilities, and consequences, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We discuss common distributed wind architectures and how they are interconnected to larger power systems. Because cybersecurity cannot exist independently, the cyber-resilience architecture must consider the system holistically. Finally, we discuss the implementation of a risk assessment process that uses the cyber-resilience framework to address challenges specific to distributed wind.

17 WIND ENERGY↗

ROTOR: Research to Operations and Operations to Research

PNNL’s Research to Operations/Operations to Research (ROTOR) Program fosters a cybersecurity operations to researcher collaboration, identifying hard problems and challenges for cyber defenders and bringing researcher science disciplines to these challenges. ROTOR allows PNNL’s cyber defenders to better protect the laboratory but also fosters innovation and incubation of solutions for our sponsor missions across DOE, DOD, DHS and the intelligence community. Our sponsors and their missions are faced with many of the same cyber defense challenges that PNNL faces. By using our own laboratory security operations environment as an innovation generator and testing ground, allowing research to be tested and tried, our sponsors are directly benefitted. PNNL is in a unique position to combine our world class research organization with enterprise cybersecurity operations. ROTOR is taking advantage of this to bring PNNL cybersecurity research projects into an operational environment within PNNL’s Cyber Security Operations Center. With ROTOR, PNNL researchers gain the advantage of operational experience and expertise and have an avenue for showcasing research in an operational environment. This helps to advance PNNL research, prove operability of PNNL projects to its sponsors, and provide real-world insight to real-world problems for our cybersecurity research agenda. ROTOR is the conduit for PNNL cybersecurity research to find its way to operational use. PNNL researchers and engineers are informed by real-world operations and operations has access to current PNNL research and engineering capabilities. All of this leads to improved reputation for PNNL as a provider of national security solutions that are tried and tested. To date, ROTOR has collaborated with six projects, enabling each to conduct operational work within the CSOC.

97 MATHEMATICS AND COMPUTING↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

EV SALaD 2023 Demonstration: Best Practices and Mitigations for Protecting EVSE Infrastructure

The Electric Vehicle Secure Architecture Laboratory Demonstration (EV SALaD) program is a demonstration of cybersecurity best practices for high-power electric vehicle (EV) charging infrastructure led by Idaho National Laboratory (INL), in collaboration with other DOE National Laboratories participating in the EVs at Scale Consortium.a Sandia National Laboratories (SNL) and Pacific Northwest National Laboratory (PNNL) participated in the first 2-year (FY22-23) demonstration cycle for EV SALaD. This report documents the FY23 demonstration, the second in a series of demonstrations and collaborations in deploying and operating cybersecure EV charging infrastructure. It includes a summary of improvements from the FY22 demonstration, technical analysis of the FY23 demonstration, how the research demonstrates cyber-physical and cybersecurity best practices for high-power EV charging infrastructure, and related impacts to national and energy security. For EV SALaD, the FY22 demonstration focused on the detection, ranking, and prioritization of anomalous events for high-power EV charging. The FY23 demonstration additionally included the demonstration of cybersecurity best practices, which included protection and mitigation solutions to prevent, respond, and recover from anomalous events. During the demonstrations, the multi-lab EV SALaD team conducted a Test Effect Payload (TEP)b evaluation on extreme fast charger (XFC) hardware equipped with Cerberus, a detection and response solution, to demonstrate anomaly detection and mitigation cybersecurity best practices against cyber-enabled events.

33 ADVANCED PROPULSION SYSTEMS↗

Retrieval Augmented Generation for Robust Cyber Defense

In cybersecurity, the ability to efficiently analyze and respond to vulnerabilities, weaknesses, attack patterns, and threat tactics is critical for effective defense strategies. With the increasing complexity and volume of cybersecurity data, traditional methods of querying and retrieving information are often inadequate. To address this challenge, we implemented Retrieval-Augmented Generation (RAG) systems—CyRAG and GraphCyRAG—that integrate large language models (LLMs) with both structured data from relational databases and knowledge graphs such as Neo4j. CyRAG is designed to handle structured data, focusing on CVE (Common Vulnerabilities and Exposures) and CWE (Common Weakness Enumeration) entities to generate accurate and context-rich responses. In contrast, GraphCyRAG leverages Neo4j knowledge graphs to retrieve interconnected information from CVE, CWE, CAPEC (Common Attack Pattern Enumeration and Classification), and ATT&CK (Adversarial Tactics, Techniques, and Common Knowledge) datasets. By utilizing Neo4j’s graph-based framework, GraphCyRAG enables deeper traversal of relationships between vulnerabilities and attack patterns, providing cybersecurity analysts with more comprehensive insights into potential attack vectors and mitigation strategies. Our preliminary results demonstrate that integrating knowledge graphs with RAG significantly enhances both the accuracy and depth of threat analysis, allowing for the retrieval of dynamic, real-time data and the generation of contextually aware responses. This approach helps analysts uncover hidden relationships between cyber entities, predict exploit paths, and prioritize mitigation efforts effectively. The integration of RAG with cybersecurity knowledge graphs represents a significant advancement in cybersecurity threat intelligence, enabling more informed decision-making and stronger defense strategies.

97 MATHEMATICS AND COMPUTING↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Cyber-Informed Engineering Guidance—Implementing CIE in Early Systems Engineering Lifecycle Stages

Traditionally, cybersecurity is not considered in the design process. Design engineers typically focus on building safety and reliability into their products and applications. Security against malicious cyber incidents is often an afterthought, resulting in deployment of security solutions during installation or operation. Unfortunately, waiting to consider cybersecurity until later in the systems engineering lifecycle often results in less effective and more expense security. Idaho National Laboratory (INL) developed the concept of Cyber-Informed Engineering (CIE) in 2015 to provide a framework that enables cybersecurity to be built into systems beginning at the conceptual design stage. In addition to ongoing research by INL, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response has recently developed a National CIE Strategy document for incorporating CIE into the design and operation of infrastructure systems reliant on digital monitoring or controls. This paper provides a brief review of this National CIE Strategy as well as a roadmap to historical, current, and future CIE research by INL through the U.S. DOE Office of Nuclear Energy (NE) Cybersecurity Crosscutting Technology Development Program. A near-term focus of the DOE-NE’s research and development is to extend the foundational CIE work into detailed guidance for implementation during initial systems engineering stages in nuclear digital instrumentation and control projects and to demonstrate use of the guidance in an integrated energy systems project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗

Distributed Energy Resource Visual Emulator: Phase 1

To help federal energy managers assess, monitor, and manage cybersecurity while achieving decarbonization, the National Renewable Energy Laboratory's Distributed Energy Resource Cybersecurity Framework (DER-CF) offers a comprehensive, web-based assessment tool focusing on cyber governance or policies, technical management, and physical security. The DER-CF currently presents users with a series of pertinent cybersecurity questions, which are used to generate a site-specific report and recommendations. This paper outlines a technical approach to integrate the DER-CF with another key asset—NREL's Advanced Research on Integrated Energy Systems (ARIES) Cyber Range—to visualize cybersecurity resilience and compliance and to enhance the usability and accessibility of the DER-CF. The result is a new tool called the Distributed Energy Resource Visual Emulator (DER-VE). Its development will include regular conversations with stakeholders to assess the effectiveness of these efforts, refine the visualization capability, and ensure its value to our partners. Phase 0 of the integration project was concluded in 2021. Phase 1, completed in 2022, has two components: The first is developing a working visualization of system compliance using the DER-CF, and the second is planning the design of a server application that takes input data from the DER-CF and creates a personal emulated environment of the user's system or a selected reference architect. Major components that were addressed in this phase are the DER-CF output, compliance visualization, data model, and compliance server design.

24 POWER TRANSMISSION AND DISTRIBUTION↗