Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Compact and Handheld Radioisotope Imaging Systems for Bio-medicine*

Author: Andrew Weisenberger (Thomas Jefferson National Accelerator Facility) Thomas Jefferson National Accelerator Facility is a U.S. Department of Energy federally funded research and development center whose mission is to study quark gluon physics. The laboratory capitalizes on its unique technologies and expertise to explore ways of applying nuclear physics principles and technologies to societal needs. The Radiation Detector and Imaging Group, in collaboration with universities, industry and other government laboratories, has for several years been applying advances in nuclear physics detector technology to several applications, particularly in the development of compact and handheld nuclear imaging systems. I will provide a brief overview of Jefferson Lab and provide examples of how the group has leveraged nuclear physics to bring advances to nuclear medicine, medical research and plant biology. The group continues to develop medical devices based on both single photon emission computed tomography (SPECT) and positron emission tomography (PET), making use of technology originally developed for basic nuclear physics research. *Thomas Jefferson National Accelerator Facility is operated by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.

Weisenberger, Andrew↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon Collider Forum report

A multi-TeV muon collider offers a spectacular opportunity in the direct exploration of the energy frontier. Offering a combination of unprecedented energy collisions in a comparatively clean leptonic environment, a high energy muon collider has the unique potential to provide both precision measurements and the highest energy reach in one machine that cannot be paralleled by any currently available technology. The topic generated a lot of excitement in Snowmass meetings and continues to attract a large number of supporters, including many from the early career community. In light of this very strong interest within the US particle physics community, Snowmass Energy, Theory and Accelerator Frontiers created a cross-frontier Muon Collider Forum in November of 2020. The Forum has been meeting on a monthly basis and organized several topical workshops dedicated to physics, accelerator technology, and detector R&D. Findings of the Forum are summarized in this report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Driving the Design of the EIC Detectors

A high luminosity polarized electron-ion collider (EIC) has been proposed as a future nuclear science program. It is envisioned as a next-generation US facility, as recommended by US Nuclear Science Advisory Committee in its 2015 Long Range Plan, for investigating of fundamental aspects of QCD, for exploring the quark-gluon structure and dynamic of hadrons and nuclei. This talk will cover key physics topics, motivating the design for the EIC detectors.

Furletova, Yulia↗

Design Process for the Development of a New Truck Monitoring System - 13306

Canberra Industries, Inc. has designed a new truck monitoring system for a facility in Japan. The customer desires to separately quantify the Cs-137 and Cs-134 content of truck cargo entering and leaving a Waste Consolidation Area. The content of the trucks will be some combination of sand, soil, and vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. The typical weight of the trucks will be approximately 10 tons, but can vary between 4 and 20 tons. The system must be sensitive enough to detect 100 Bq/kg in 10 seconds (with less than 10% relative standard deviation) but still have enough dynamic range to measure 1,000,000 Bq/kg material. The system will be operated in an outdoor environment. Starting from these requirements, Canberra explored all aspects of the counting system in order to provide the customer with the optimized solution. The desire to separately quantify Cs-137 and Cs-134 favors the use of a spectroscopic system as a solution. Using the In Situ Object Counting System (ISOCS) mathematical efficiency calculation tool, we explored various detector types, number, and physical arrangement for maximum performance. Given the choice of detector, the ISOCS software was used to investigate which geometric parameters (fill height, material density, etc.) caused the most fluctuations in the efficiency results. Furthermore, these variations were used to obtain quantitative estimates of the uncertainties associated with the possible physical variations in the truck size, detector positioning, and material composition, density, and fill height. Various shielding options were also explored to ensure that any measured Cs content would be from the truck and not from the surrounding area. The details of the various calculations along with the final design are given. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ProtoDUNE-SP's Performance, Physics status, and Future Plans

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber measuring$ 7.2 \times 6.1 \times 7.0 m^3$ in active volume. It is designed as a test bed and full-scale prototype for the elements of the first far detector module of the Deep Underground Neutrino Experiment (DUNE). Located at the CERN Neutrino Platform, the detector was exposed to a tagged and momentum-analyzed particle beam with momentum settings ranging from 0.3 GeV/c to 7 GeV/c and collected more than four million beam events. Additionally, the detector operated for approximately two years, continuously collecting cosmic ray events. We present the performance of the detector which has met or surpassed the specifications set for the DUNE far detector. The status of physics analyses including hadron-Ar cross sections and measurements of liquid argon properties will be summarized. Talk will conclude with plans for the coming Run2 with ProtoDUNE-HD (horizontal drift).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Pixel upgrade for Phase 1

Performance and lesson learned with the CMS Pixel Detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics of intense, high energy radiation effects.

This document summarizes the work done in our three-year LDRD project titled 'Physics of Intense, High Energy Radiation Effects.' This LDRD is focused on electrical effects of ionizing radiation at high dose-rates. One major thrust throughout the project has been the radiation-induced conductivity (RIC) produced by the ionizing radiation. Another important consideration has been the electrical effect of dose-enhanced radiation. This transient effect can produce an electromagnetic pulse (EMP). The unifying theme of the project has been the dielectric function. This quantity contains much of the physics covered in this project. For example, the work on transient electrical effects in radiation-induced conductivity (RIC) has been a key focus for the work on the EMP effects. This physics in contained in the dielectric function, which can also be expressed as a conductivity. The transient defects created during a radiation event are also contained, in principle. The energy loss lead the hot electrons and holes is given by the stopping power of ionizing radiation. This information is given by the inverse dielectric function. Finally, the short time atomistic phenomena caused by ionizing radiation can also be considered to be contained within the dielectric function. During the LDRD, meetings about the work were held every week. These discussions involved theorists, experimentalists and engineers. These discussions branched out into the work done in other projects. For example, the work on EMP effects had influence on another project focused on such phenomena in gases. Furthermore, the physics of radiation detectors and radiation dosimeters was often discussed, and these discussions had impact on related projects. Some LDRD-related documents are now stored on a sharepoint site (https://sharepoint.sandia.gov/sites/LDRD-REMS/default.aspx). In the remainder of this document the work is described in catergories but there is much overlap between the atomistic calculations, the continuum calculations and the experiments.

36 MATERIALS SCIENCE↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Center for Applied Physics and Superconducting Technologies (CAPST)

Fermi Research Alliance, LLC, as operator of Fermi National Accelerator Laboratory (Fermilab) and Northwestern University (Northwestern) have a broad overlap in scientific interests and complementary state-of-the-art facilities in the area of applied physics and technology, in particular physics of superconductivity, materials science, and detector technology. The Center for Applied Physics and Superconducting Technology (CAPST) will provide a mechanism for cross-utilizing capabilities of the two institutions for advances in understanding key scientific problems of mutual interest and opening up broader educational opportunities for students and postdoctoral candidates (postdocs). Northwestern undergraduate students, graduate students and postdocs will be able to perform cutting edge science and technology research in accelerator and detector science and the physics of superconductivity at Fermilab and Northwestern under the joint direction of Fermilab researchers and Northwestern professors. Research program covers three thrusts below, with subtopics detailed in the CRADA: • Vortex dynamics in superconductors • Superconducting devices • New frontiers in microwave instrumentation/techniques.

47 OTHER INSTRUMENTATION↗

Noise propagation issues in Belle II pixel detector power cable

The vertex detector used in the upgrade of High-Energy physics experiment Belle II includes DEPFET pixel detector (PXD) technology. In this complex topology the power supply units and the front-end electronics are connected through a PXD power cable bundle which may propagate the output noise from the power supplies to the vertex area. This article presents a study of the propagation of noise caused by power converters in the PXD cable bundle based on Multi-conductor Transmission Line (MTL) theory. The work exposes the effect of the complex cable topology and shield connections on the noise propagation, which has an impact on the requirements of the power supplies. This analysis is part of the electromagnetic compatibility based design focused on functional safety to define the shield connections and power supply specifications required to ensure the successful integration of the detector and, specifically, to achieve the designed performance of the front-end electronics.

42 ENGINEERING↗

Evaluation of CdZnTeSe as a high-quality gamma-ray spectroscopic material with better compositional homogeneity and reduced defects

X- and gamma-ray detectors have broad applications ranging from medical imaging to security, non-proliferation, high-energy physics and astrophysics. Detectors with high energy resolution, e.g. less than 1.5% resolution at 662 keV at room temperature, are critically important in most uses. The efficacy of adding selenium to the cadmium zinc telluride (CdZnTe) matrix for radiation detector applications has been studied. In this paper, the growth of a new quaternary compound Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 by the Traveling Heater Method (THM) is reported. The crystals possess a very high compositional homogeneity with less extended defects, such as secondary phases and sub-grain boundary networks. Virtual Frisch-grid detectors fabricated from as-grown ingots revealed ~0.87-1.5% energy resolution for 662-keV gamma rays. The superior material quality with a very low density of defects and very high compositional homogeneity heightens the likelihood that Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 will be the next generation room-temperature detector material.

36 MATERIALS SCIENCE↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Near Detectors for a Neutrino Factory

The baseline design for a Neutrino Factory includes the need for one or more near detectors.The near detectors must be designed to carry out measurements essential to the sensitivity of the oscillation-physics program. In addition, the intense neutrino beam delivered by the Neutrino Factory makes it possible to carry out a unique neutrino-physics program at the near detectors. This program includes fundamental electroweak and QCD physics. The near detector must also be capable of searching for new physics, for example by detecting tau-leptons which are particularly sensitive probes of non-standard interactions at source and at detection. This paper is extracted from the Near Detector chapter of the Neutrino Factory Interim Design Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Heavy Resonances in the Dimuon Channel with the DØ Detector

High-energy particle physics is often described as the quest for a fundamental theory. One can think of one theory as being more "fundamental" than a second theory if the first explains some or all of the predictions of the second in terms of processes at smaller distance scales and higher energies. Another sense in which a theory can be thought of as being more fundamental than another, is if the first theory "explains" the second; that is, if some arbitrary aspect of the second theory is a special case of a more general principle in the first theory. The Standard Model of particle physics is the most fundamental experimentally tested theory in either sense. It was developed in its final form in the 1960's and 1970's and continues to successfully predict the outcomes of high-energy physics experiments; the research presented in this thesis offers no exception to this trend ( unfortunately). However, the Standard Model only makes sense as an effective theory; that is, a theory that is not actually fundamental, but which is a low-energy limit of some underlying theory, without being dependent on the details of that underlying theory. Moreover, one important aspect of the Standard Model so far remains unexplained, namely electroweak symmetry breaking. Phase transitions occur in many places in physics, and can often be explained as a low-energy aspect of some more fundamental process. However, there is no such underlying process for electroweak symmetry breaking within the Standard Model; the introduction of the scalar Higgs field does not, in itself, explain electroweak symmetry breaking, it merely parameterizes it. Therefore, it is perhaps not surprising that the (most obvious) problem with the Standard Model, the '·gauge hierarchy problem", occurs in relation with the Higgs field. This problem, the "unnaturalness" of the Standard Model, will be discussed (briefly) in the next chapter. It so happens that the unnaturalness of the Standard Model strongly suggests the presence of new physics at an energy scale that is very close to the energies achieved with the Tevatron collider (and presumably well within the reach of the next collider, the LHC). Therefore, there is a general expectation that new physics is "just around the corner". Many, many models for new physics exist, and it is not possible to devise an optimal search strategy for all of them at once. Therefore (and possibly to reduce bias), it is preferable to search for new physics in a model-independent way. While the analysis presented in this thesis is certainly not model-independent, it uses the fact that many, often very different models share the prediction of a new mass resonance. Specifically, we search for such resonances in the dimuon channel. Since no new resonance was in fact observed, the various models only serve to parameterize the degree to which nothing was found. In chapter 2, an outline of the Standard Model is given, and some extensions to the Standard Model are described. Chapter 3 describes the accelerator complex and the D0 detector. Chapter 4 describes the simulation of both Standard Model and new physics processes and the detector simulation. Chapter 5 describes the data sample, the reconstruction algorithms, the event selection and the kinematic fit. A sample of high-PT dimuon events is obtained by applying a number of cuts, and the simulation is tuned to match the efficiencies and track resolution measured on Z→ μ + μ - data. The integrated luminosity times the trigger efficiency of the final sample is determined by comparing it to the predicted (and well-tested) Z cross section. The mass resolution is improved by a kinematic fit which uses the transverse energy balance in the event to constrain the muon track P T for each event in the final selection. In chapter 6, a final cut on the (fitted) invariant mass of the selected events is chosen in such a way that it maximizes the sensitivity to the presence of new physics for specific models and resonance masses. A counting experiment is performed for several values of the mass of a hypothetical new particle. Since no excess over the predicted background is observed, Bayesian credibility limits on the production cross-section times branching ratio of the hypothetical new particles were calculated, as well as limits on the parameters of new physics models. The uncertainties on the theory and detector simulation are taken into account. An event display of the highest reconstructed mass event is shown as well. Finally, chapter 7 gives a conclusion, some prospects of improving the result and a brief outlook.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗