Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIFFRACTION MODELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Diffractive PDF fits and factorisation tests at HERA

A DGLAP next-to-leading-order QCD analysis to extract the diffractive parton distribution functions, using DIS inclusive and dijet diffractive HERA data, is presented. Predictions based on the extracted parton densities are compared to diffractive dijet photoproduction data to discuss factorisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Short and Long Range Atomic Order in Nanocrystalline Diamonds with Application of Powder Diffractometry

Fundamental limitations, with respect to nanocrystalline materials, of the traditional elaboration of powder diffraction data like the Rietveld method are discussed. A tentative method of the analysis of powder diffraction patterns of nanocrystals is introduced which is based on the examination of the variation of lattice parameters calculated from individual Bragg lines (named the "apparent lattice parameter", alp). We examine the application of our methodology using theoretical diffraction patterns computed for models of nanocrystals with a perfect crystal lattice and for grains with a two-phase, core-shell structure. We use the method for the analysis of X-ray and neutron experimental diffraction data of nanocrystalline diamond powders of 4, 6 and 12 nm in diameter. The effects of an internal pressure and strain at the grain surface is discussed. This is based on the dependence of the alp values oil the diffraction vector Q and on the PDF analysis. It is shown, that the experimental results support well the concept of the two-phase structure of nanocrystalline diamond.

Palosz, B.↗

Application of Powder Diffraction Methods to the Analysis of Short- and Long-Range Atomic Order in Nanocrystalline Diamond and SiC: The Concept of the Apparent Lattice Parameter (alp)

Two methods of the analysis of powder diffraction patterns of diamond and SiC nanocrystals are presented: (a) examination of changes of the lattice parameters with diffraction vector Q ('apparent lattice parameter', alp) which refers to Bragg scattering, and (b), examination of changes of inter-atomic distances based on the analysis of the atomic Pair Distribution Function, PDF. Application of these methods was studied based on the theoretical diffraction patterns computed for models of nanocrystals having (i) a perfect crystal lattice, and (ii), a core-shell structure, i.e. constituting a two-phase system. The models are defined by the lattice parameter of the grain core, thickness of the surface shell, and the magnitude and distribution of the strain field in the shell. X-ray and neutron experimental diffraction data of nanocrystalline SiC and diamond powders of the grain diameter from 4 nm up to micrometers were used. The effects of the internal pressure and strain at the grain surface on the structure are discussed based on the experimentally determined dependence of the alp values on the Q-vector, and changes of the interatomic distances with the grain size determined experimentally by the atomic Pair Distribution Function (PDF) analysis. The experimental results lend a strong support to the concept of a two-phase, core and the surface shell structure of nanocrystalline diamond and SiC.

Palosz, B.↗

Computer modeling of electromagnetic problems using the geometrical theory of diffraction

Some applications of the geometrical theory of diffraction (GTD), a high frequency ray optical solution to electromagnetic problems, are presented. GTD extends geometric optics, which does not take into account the diffractions occurring at edges, vertices, and various other discontinuities. Diffraction solutions, analysis of basic structures, construction of more complex structures, and coupling using GTD are discussed.

Burnside, W. D.↗

On the Elevated Temperature Thermal Stability of Nanoscale Mn-Ni-Si Precipitates Formed at Lower Temperature in Highly Irradiated Reactor Pressure Vessel Steels

Atom probe tomography (APT) and scanning transmission electron microscopy (STEM) techniques were used to probe the long-time thermal stability of nm-scale Mn-Ni-Si precipitates (MNSPs) formed in intermediate and high Ni reactor pressure vessel steels under high fluence neutron irradiation at ≈320 °C. Post irradiation annealing (PIA) at 425 °C for up to 57 weeks was used to determine if the MNSPs are: (a) non-equilibrium solute clusters formed and sustained by radiation induced segregation (RIS); or, (b) equilibrium G or Γ 2 phases, that precipitate at accelerated rates due to radiation enhanced diffusion (RED). Note the latter is consistent with both thermodynamic models and x-ray diffraction (XRD) measurements. Both the experimental and an independently calibrated cluster dynamics (CD) model results show that the stability of the MNSPs is very sensitive to the alloy Ni and, to a lesser extent, Mn content. Thus, a small fraction of the largest MNSPs in the high Ni steel persist, and begin to coarsen at long times. These results suggest that the MNSPs remain a stable phase, even at 105 °C higher than they formed at, thus are most certainly equilibrium phases at much lower service relevant temperatures of ≈290 °C.

36 MATERIALS SCIENCE↗

Diffraction-controlled backscattering threshold and application to Raman gap

In most classic analytical models of linear stimulated scatter, light diffraction is omitted, a priori. However, modern laser optic typically includes a variant of the random phase plate [Y. Kato et al., Phys. Rev. Lett. 53, 1057 (1984)], resulting in diffraction limited laser intensity fluctuations - or localized speckles - which may result in explosive reflectivity growth as the average laser intensity approaches a critical value [H. A. Rose and D. F. DuBois, Phys. Rev. Lett. 72, 2883 (1994)]. Among the differences between stimulated Raman scatter (SRS) and stimulated Brillouin scatter is that the SRS scattered light diffracts more strongly than the laser light with increase of electron density. This weakens the tendency of the SRS light to closely follow the most amplified paths, diminishing gain. Let G{sub 0} be the one-dimensional power gain exponent of the stimulated scatter. In this paper we show that differential diffraction gives rise to an increase of G{sub 0} at the SRS physical threshold with increase of electron density up to a drastic disruption of SRS as electron density approaches one fourth of its critical value from below. For three wave interaction lengths not small compared to a speckle length, this is a physically robust Raman gap mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lessons from LHC elastic and diffractive data

In the light of LHC data, we discuss the global description of all high-energy elastic and diffractive data, using a one-pomeron model, but including multi-pomeron interactions. The LHC data indicate the need of a k{sub t}(s) behaviour, where k{sub t} is the gluon transverse momentum along the partonic ladder structure which describes the pomeron. We also discuss tensions in the data, as well as the t dependence of the slope of dσ{sub el}/dt in the small t domain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Artificial generation of representative single Li-ion electrode particle architectures from microscopy data

Accurately capturing the architecture of single lithium-ion electrode particles is necessary for understanding their performance limitations and degradation mechanisms through multi-physics modeling. Information is drawn from multimodal microscopy techniques to artificially generate LiNi 0.5 Mn 0.3 Co 0.2 O 2 particles with full sub-particle grain detail. Statistical representations of particle architectures are derived from X-ray nano-computed tomography data supporting an ‘outer shell’ model, and sub-particle grain representations are derived from focused-ion beam electron backscatter diffraction data supporting a ‘grain’ model. A random field model used to characterize and generate the outer shells, and a random tessellation model used to characterize and generate grain architectures, are combined to form a multi-scale model for the generation of virtual electrode particles with full-grain detail. This work demonstrates the possibility of generating representative single electrode particle architectures for modeling and characterization that can guide synthesis approaches of particle architectures with enhanced performance.

36 MATERIALS SCIENCE↗

Evaluating the Taylor hardening model in polycrystalline Ti using high energy X-ray diffraction microscopy

High energy X-ray diffraction microscopy (HEDM) was employed to index nearly 1000 grains in a polycrystalline Ti specimen and characterize their deformation during an incremental tensile test. For each grain, the positions of its associated diffraction peaks were used for analyzing its evolving crystal orientation and stress tensor. The azimuthal breadth of each peak at different load steps was measured, allowing measurement of initial yielding and providing an estimate of the dislocation density evolution in each grain. Furthermore, the Taylor hardening model was evaluated grain by grain using the above data, indicating that it can represent hardening in most grains. The yield stress and the strain hardening coefficient for all grains were statistically analyzed with respect to grain orientation, grain size, slip systems, and the surrounding neighborhood to examine how the yield stress and hardening are correlated.

36 MATERIALS SCIENCE↗

Machine Learning Based System for Automated Estimation of Crystal Unit Cell Parameters from X-ray Diffraction Powder Patterns (MLCell) v0.1

This software uses machine learning models to perform inference on X-ray diffraction powder patterns, output from a diffractometer, to estimate all 6 unit cell parameters of crystalline lattices. Novel aspects of this software originated from the incorporation of concepts from crystallography to an ML-based approach; The resulting method achieves new performance capabilities without significant loss of accuracy and with less computationally intensive models.

Oklejas, Vanessa↗

Free kick instead of cross-validation in maximum-likelihood refinement of macromolecular crystal structures

The maximum-likelihood free-kick target, which calculates model error estimates from the work set and a randomly displaced model, proved superior in the accuracy and consistency of refinement of crystal structures compared with the maximum-likelihood cross-validation target, which calculates error estimates from the test set and the unperturbed model. The refinement of a molecular model is a computational procedure by which the atomic model is fitted to the diffraction data. The commonly used target in the refinement of macromolecular structures is the maximum-likelihood (ML) function, which relies on the assessment of model errors. The current ML functions rely on cross-validation. They utilize phase-error estimates that are calculated from a small fraction of diffraction data, called the test set, that are not used to fit the model. An approach has been developed that uses the work set to calculate the phase-error estimates in the ML refinement from simulating the model errors via the random displacement of atomic coordinates. It is called ML free-kick refinement as it uses the ML formulation of the target function and is based on the idea of freeing the model from the model bias imposed by the chemical energy restraints used in refinement. This approach for the calculation of error estimates is superior to the cross-validation approach: it reduces the phase error and increases the accuracy of molecular models, is more robust, provides clearer maps and may use a smaller portion of data for the test set for the calculation of R{sub free} or may leave it out completely.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The “good,” the “bad,” and the “hidden” in neutron scattering and molecular dynamics of ionic aqueous solutions

We characterize a concentrated 7.3 m CaCl 2 solution, combining neutron diffraction with chloride isotopic substitution (Cl-NDIS) in null water and molecular dynamics (MD) simulations. We elucidate the solution structure, thermodynamic properties, and extent of ion pairing previously suggested as concentration-dependent and often not observed at lower concentrations. Our Cl-NDIS measurements designate the solvent-shared ion pairing as dominant and the contact ion pairing (CIP) as insignificant even under conditions close to the solubility limit. The MD models parameterized against neutron diffraction with calcium isotopic substitution (Ca-NDIS) overestimate CIP despite successfully reproducing most of the Cl-NDIS signal. This drawback originates from the fact that Ca 2+ –Cl - interactions were primarily “hidden” in the Ca-NDIS signal due to overlapping with Ca 2+ –O w and Ca 2+ –H w contributions to the total scattering. Contrary, MD models with moderate CIP and possessing generally good performance at high concentrations fail to reproduce the NDIS measurements accurately. Therefore, the electronic polarization, introduced in most of the recent MD models via scaling ionic charges, resolves some but not all parameterization drawbacks. We conclude that despite improving the quality of MD models “on average,” the question “which model is the best” has not been answered but replaced by the question “which model is better for a given research.” An overall “good” model can still be inappropriate or, in some instances, “bad” and, unfortunately, produce erroneous results. Additionally, the accurate interpretation of several NDIS datasets, complemented by MD simulations, can prevent such mistakes and help identify the strengths, weaknesses, and convenient applications for corresponding computational models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong-field induced fragmentation and isomerization of toluene probed by ultrafast femtosecond electron diffraction and mass spectrometry

We investigate the fragmentation and isomerization of toluene molecules induced by strong-field ionization with a femtosecond near-infrared laser pulse. Momentum-resolved coincidence time-of-flight ion mass spectrometry is used to determine the relative yield of different ionic products and fragmentation channels as a function of laser intensity. Ultrafast electron diffraction is used to capture the structure of the ions formed on a picosecond time scale by comparing the diffraction signal with theoretical predictions. Through the combination of the two measurements and theory, we are able to determine the main fragmentation channels and to distinguish between ions with identical mass but different structures. In addition, our diffraction measurements show that the independent atom model, which is widely used to analyze electron diffraction patterns, is not a good approximation for diffraction from ions. Here, we show that the diffraction data is in very good agreement with ab initio scattering calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-D-213-03: Towards An Optimized 3D Scintillation Dosimetry Tool for Quality Assurance of Dynamic Radiotherapy Techniques

Purpose: The purpose of this work is to simulate a multi-focus plenoptic camera used as the measuring device in a real-time three-dimensional scintillation dosimeter. Simulating and optimizing this realistic optical system will bridge the technological gap between concept validation and a clinically viable tool that can provide highly efficient, accurate and precise measurements for dynamic radiotherapy techniques. Methods: The experimental prototype, previously developed for proof of concept purposes, uses an off-the-shelf multi-focus plenoptic camera. With an array of interleaved microlenses of different focal lengths, this camera records spatial and angular information of light emitted by a plastic scintillator volume. The three distinct microlens focal lengths were determined experimentally for use as baseline parameters by measuring image-to-object magnification for different distances in object space. A simulated plenoptic system was implemented using the non-sequential ray tracing software Zemax: this tool allows complete simulation of multiple optical paths by modeling interactions at interfaces such as scatter, diffraction, reflection and refraction. The active sensor was modeled based on the camera manufacturer specifications by a 2048×2048, 5 µm-pixel pitch sensor. Planar light sources, simulating the plastic scintillator volume, were employed for ray tracing simulations. Results: The microlens focal lengths were determined to be 384, 327 and 290 µm. A realistic multi-focus plenoptic system, with independently defined and optimizable specifications, was fully simulated. A f/2.9 and 54 mm-focal length Double Gauss objective was modeled as the system’s main lens. A three-focal length hexagonal microlens array of 250-µm thickness was designed, acting as an image-relay system between the main lens and sensor. Conclusion: Simulation of a fully modeled multi-focus plenoptic camera enables the decoupled optimization of the main lens and microlens specifications. This work leads the way to improving the 3D dosimeter’s achievable resolution, efficiency and build for providing a quality assurance tool fully meeting clinical needs. M.R. is financially supported by a Master’s Canada Graduate Scholarship from the NSERC. This research is also supported by the NSERC Industrial Research Chair in Optical Design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗