Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIRECTIONAL DRILLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Temperature Uncertainty Modeling with Proxy Structural Data as Geostatistical Constraints for Well Siting: An Example Applied to Granite Springs Valley, NV, USA

Utilizing existing temperature and structural information around Granite Springs Valley, Nevada, we build 3D stochastic temperature models with the aim of evaluating the 3D uncertainty of temperature and choosing between candidate exploration well locations . The data used to support the modeling are measured temperatures and structural proxies from 3D geologic modeling, the latter considered "secondary" data. Two stochastic geostatistical techniques are explored for incorporating the structural proxies: cosimulation and local varying mean. With both the cosimulation and local varying mean methods, many equally likely temperature models (i.e., realizations) are produced, from which temperature probability profiles are calculated at candidate well locations. To aid in choosing between the candidate locations, two quantities summarize the temperature probabilities: Vprior and entropy. Vprior quantifies the likelihood for economic temperatures at each candidate location, whereas entropy identifies where new information has the most potential to reduce uncertainty. In general, the cosimulation realizations have smoother spatial structure, and extrapolate high temperatures at candidate locations that are located along the direction of the longest spatial correlation, which are down dip from existing temperature logs. The smooth realizations result in tight temperature probability profiles that are easier to interpret, but they have unrealistic temperature reversals in some locations because the cosimulation technique does not enforce a conductive geothermal gradient as a baseline (i.e., linearly increasing temperature with depth). The local varying mean results produce realizations with more realistic geothermal gradients, with temperatures increasing downward since a depth-temperature relationship is included. However, because they have much noisier spatial nature compared to cosimulation, it is harder to interpret the temperature probability profiles. The different local varying mean results allow the geologist to determine which proxy (e.g., dilation versus distance to fault termination) should be used given the specific geothermal system. In general, Vprior from local varying mean results identify locations that are close to high values for the structural proxies: areas with highe r probabilities for higher temperatures. The entropy results identify where uncertainty is greatest and therefore new drilling information could be most useful. Though these techniques provide useful information, even when applied to areas of sparse data, our comp arison of these two techniques demonstrates the need for new geothermal geostatistics techniques that combine the advantages of these two methods and that are tailored to the spatial uncertainty issues inherent in geothermal exploration.

3D temperature modeling↗

Active Volcanoes of Kamchatka as Suitable Terrestrial Analogs for Future Landing Missions and for Change Detection Analysis on Venus

The next decade will see the return to Venus due to a number of missions which have been recently selected and proposed for launch. The selected missions NASA DAVINCI and VERITAS, Roscosmos Venera-D, and ESA EnVision, along with the proposed missions ISRO Shukrayaan- 1, and CNSA VOICE, will open a new era for the exploration of the Earth’s hellish twin planet. These missions will shed new light on the science questions such as: (a) whether recent volcanic activity is locally constrained, or active volcanism occurs on a global scale; (b) the rate of the present-day volcanic activity; (c) the styles of volcanism on Venus, including possible occurrences of pyroclastic/explosive volcanism; and (d) how does the extreme environment on Venus effect volcanic activity. In preparation for these future missions to Venus, the Analogs for VENus’ GEologically Recent Surfaces (AVENGERS) initiative has the scope to select and analyze a number of active terrestrial volcanoes as suitable analogs for the identification and analysis of active volcanism on Venus. The Roscosmos Venera-D is the only mission, among the currently selected or planned mission, equipped with a lander to analyze the elemental and mineralogical composition of the surface. Therefore, it is crucial to find applicable volcanic areas on Earth to perform operational tests such as surface drilling and in-situ elemental composition analysis. To this regard, we propose the analysis of active volcanoes of the Kamchatka Peninsula, which is in a geodynamic setting (subduction) contrasting to that of the volcanic rises on Venus (hot spot). Thus, Kamchatka may represent a helpful geodynamic endmember to put the expected landing site of the Venera-D mission within the context of the entire variety of volcanic landforms and surface chemistry. The Kamchatka Peninsula is located on the eastern margin of the Eurasian plate, in proximity to the Kuril-Kamchatka subduction zone. The frequent eruptions characterizing the volcanoes of the Kamchatka Peninsula make them a suitable terrestrial analog for the possible detection of ongoing eruptions on Venus by future missions, which can be achieved by comparing a sequence of radar images of the same volcano and its surroundings taken at different times. Moreover, it is possible to collect samples of both unweathered and weathered volcanic deposits, to analyze their near infrared spectra in the laboratory for direct comparison with the spectra to be provided by the future missions to Venus. The chemical analyses of Venusian surface materials from the previous Soviet Venera and Vega missions are consistent with that of tholeiitic basalts. Since the volcanism of the Kamchatka Peninsula is characterized by both basaltic lava flows eruptions and pyroclastic activity, performing operational tests in the Kamchatka Peninsula also offers the unique opportunity to provide us the tools to potentially interpret the diverse output given by both effusive and explosive volcanic products.

Piero D'Incecco↗

Flexible Geothermal Power Generation utilizing Geologic Thermal Energy Storage (Final Seedling Project Report)

This report concludes that there is a cost-effective strategy for seasonal storage of heat that will provide firm, but dispatchable, electrical generating capacity in times when other renewable energy is not available to meet demand. Deployment of the technology appears to require no new technology, but instead combines solar, geothermal, and conventional oil and gas drilling technologies in a novel way. The study basis is the use of sedimentary geologic formations as a medium for thermal energy storage (TES), specifically for heat collected in concentrating solar collectors. The study identifies methodologies that could be used to transport this heat into and out of the subsurface in order to produce dispatchable electrical power, and reports on initial optimization results. The GeoTES system (heat input, storage, heat recovery, and heat to electric conversion) described in this analysis has the potential to provide a unique pathway for increasing the grid penetration of renewable energy in large blocks of power and across many states and regions. Further, the system can be used both to meet the nation’s flexible energy needs while also improving grid stability and reliability. The present study evaluated the use of a large number of dedicated wells to store and recover the heat, essentially creating a synthetic geothermal reservoir. The use of sedimentary geology allows the wells to be drilled at low cost. Dedicated hot and cold wells are used, arranged in a five-spot well pattern with each hot or cold well surrounded at an appropriate distance by the opposite type of well. In large numbers this becomes alternating rows of hot and cold wells. Each hot and cold well is operated using a push-pull strategy. This configuration provides the ability to immediately recover stored hot fluid from a GeoTES reservoir, or to store the heat over many months for recovery at low loss when needed. This is a practical approach for managing the system’s fluid inventory and reducing parasitic load. The production and injection power requirements are reduced because the rows of wells operating in “push” mode provide help to the wells operating in “pull” mode, and vice-versa. Initial charging of a GeoTES system increases the heat recovery temperature. Increasing the duration of the charging period decreases the magnitude of the temperature fluctuations that occur following prolonged system operation. Because of direct contact of the heated water with the reservoir formation, the production of both hot water and steam from the TES, and the temperature ranges of the recovered fluid (190 – 230°C or 375 – 445°F), conventional geothermal power cycles were used to convert the stored heat to electricity. A power cycle configuration for the GeoTES system was selected following a screening study of a number of flash, and flash/binary hybrid options. This analysis concluded that, of the configurations evaluated, a dual-stage flash steam cycle provides the lowest capital costs per unit net power generation with an acceptable hot brine inlet fluid flow rate. The evaluation included the power plant cost estimate, the cost and number of wells and the associated parasitic loads. Annual power generation performance was simulated to evaluate capacity factor and LCOE. The LCOE calculated for the inherently high capacity GeoTES system was $\$$0.13/kWhe. This value was calculated for the case where the solar thermal collector was sized in such a way that the solar collectors permitted an annual power plant capacity factor of up to 97%. The power cycle was able to provide power to the grid every night of the year, and flexible base-load power during the winter, if needed. This LCOE value compares favorably with reported values for solar photovoltaic plus battery energy storage (PV+BES) systems in the open literature, i.e. $\$$0.148/kWhe for a PV+BES system with 4 hours of electrochemical battery energy storage capacity. Addition of battery energy storage with more hours of storage would further increase PV+BES system LCOE and increase the separation between GeoTES and PV+BES. A GeoTES system would therefore provide superior economics for high capacity and long duration solar energy storage.

14 SOLAR ENERGY↗

Two-Piece Screens for Decontaminating Granular Material

Two-piece screens have been designed specifically for use in filtering a granular material to remove contaminant particles that are significantly wider or longer than are the desired granules. In the original application for which the twopiece screens were conceived, the granular material is ammonium perchlorate and the contaminant particles tend to be wires and other relatively long, rigid strands. The basic design of the twopiece screens can be adapted to other granular materials and contaminants by modifying critical dimensions to accommodate different grain and contaminant- particle sizes. A two-piece screen of this type consists mainly of (1) a top flat plate perforated with circular holes arranged in a hexagonal pattern and (2) a bottom plate that is also perforated with circular holes (but not in a pure hexagonal pattern) and is folded into an accordion structure. Fabrication of the bottom plate begins with drilling circular holes into a flat plate in a hexagonal pattern that is interrupted, at regular intervals, by parallel gaps. The plate is then folded into the accordion structure along the gaps. Because the folds are along the gaps, there are no holes at the peaks and valleys of the accordion screen. The top flat plate and the bottom accordion plate are secured within a metal frame. The resulting two-piece screen is placed at the bottom opening of a feed hopper containing the granular material to be filtered. Tests have shown that such long, rigid contaminant strands as wires readily can pass through a filter consisting of the flat screen alone and that the addition of the accordion screen below the flat screen greatly increases the effectiveness of removal of wires and other contaminant strands. Part of the reason for increased effectiveness is in the presentation of the contaminant to the filter surface. Testing has shown that wire type contamination will readily align itself parallel to the material direction flow. Since this direction of flow is nearly always perpendicular to the filter surface holes, the contamination is automatically aligned to pass through. The two-filter configuration reduces the likelihood that a given contaminant strand will be aligned with the flow of material by eliminating the perpendicular presentation angle. Thus, for wires of a certain diameter, a two-piece screen is 20 percent more effective than is the corresponding flat perforated plate alone, even if the holes in the flat plate are narrower. An accordion screen alone is similarly effective in catching contaminants, but lumps of agglomerated granules of the desired material often collect in the valleys and clog the screen. The addition of a flat screen above the accordion screen prevents clogging of the accordion screen. Flat wire screens have often been used to remove contaminants from granular materials, and are about as effective as are the corresponding perforated flat plates used alone.

Backes, Douglas↗

Detailed analysis of geothermal potential in Crescent Valley, north-central Nevada

This study has synthesized geological, geochemical, and geophysical data sets to elucidate the structural architecture and history of the Crescent basin in order to assess its geothermal potential. The Crescent basin is a complex composite basin, consisting primarily of multiple east-tilted half grabens and horst blocks bounded by several major faults of variable strike. Fault kinematic data indicate a present-day west-northwesttrending least principal stress, which in turn suggests that north-northeast-striking normal faults have relatively high slip and dilation tendency. However, a protracted history of changing Cenozoic extension directions has produced a mosaic of fault patterns, which has generated both segmented fault geometries and multiple fault intersections. These structural complexities have ultimately primed the basin for geothermal activity. Detailed analyses and application of the play fairway methodology have respectively denoted and ranked 12 favorable structural settings capable of hosting geothermal fluids in the Crescent basin. Of the 12 favorable structural settings, five were identified as having a higher likelihood of hosting a relatively high-temperature (>130°C) geothermal system, including Hand-Me-Down Creek, Hot Springs Point, and three other unnamed areas. The Hand-Me-Down Creek hybrid structural setting along the Crescent Valley fault is the only documented relatively high temperature geothermal system identified in the basin. It contains an active 87°C hot spring actively depositing sinter and geothermometry greater than 170°C (possibly >180°C). Future exploration efforts at Hand-Me-Down Creek would benefit from focusing on targeting high permeability zones at depth utilizing densely spaced electromagnetic surveys, fluid flow modeling, and selective drilling that targets specific fault intersections within the greater step-over at depth. The Hot Springs Point hybrid structural setting along the Dry Hills fault hosts a geothermal system, but geothermometry, spring temperatures, and well temperatures indicate that fluids do not exceed ~100°C. Three other relatively promising areas include a fault intersection in the central part of the basin and two step-overs (relay ramps) along the Crescent Valley fault, but additional exploration is needed at these sites, such as 2-m temperature surveys in the dry season, measuring deeper subsurface temperatures through temperature-gradient drilling, and collecting water samples through geoprobe drilling to estimate geothermometry.

15 GEOTHERMAL ENERGY↗

Temperature uncertainty modelling with proxy structural data as geostatistical constraints for well siting: an example applied to Granite Springs Valley, NV, USA

Utilizing existing temperature and structural geology information around Granite Springs Valley, Nevada, we build 3D stochastic temperature models with the aims of evaluating the 3D uncertainty of temperature and choosing between candidate exploration well locations. The data used to support the modelling are measured temperatures and structural proxies from 3D geologic modelling (distance to fault, distance to fault intersections and terminations, Coulomb stress change and dilation tendency), the latter considered ‘secondary’ data. Two stochastic geostatistical techniques are explored for incorporating the structural proxies: cosimulation and local varying mean. With both the cosimulation and local varying mean methods, many equally-likely temperature models (i.e. realizations) are produced, from which temperature probability profiles are calculated at candidate well locations. To aid in choosing between the candidate locations, two quantities summarize the temperature probabilities: V prior and entropy. V prior quantifies the likelihood for economic temperatures at each candidate location, whereas entropy identifies where new information has the most potential to reduce uncertainty. In general, the cosimulation realizations have smoother spatial structure, and extrapolate high temperatures at candidate locations that are located along the direction of the longest spatial correlation, which are down dip from existing temperature logs. The smooth realizations result in tight temperature probability profiles that are easier to interpret, but they have unrealistic temperature reversals in some locations because of the dipping ellipsoid shape created and that the cosimulation technique does not enforce a conductive geothermal gradient as a baseline (i.e. linearly increasing temperature with depth). The local varying mean results produce realizations with more realistic geothermal gradients, with temperatures increasing downward since a depth-temperature relationship is included. However, because they have much noisier spatial nature compared to cosimulation, it is harder to interpret the temperature probability profiles. The different local varying mean results allow the geologist to determine which proxy (e.g. dilation v. distance to fault termination) should be used given the specific geothermal system. In general, V prior from local varying mean results identify locations that are close to high values for the structural proxies: areas with higher probabilities for higher temperatures. The entropy results identify where uncertainty is greatest and therefore new drilling information could be most useful. Though these techniques provide useful information, even when applied to areas of sparse data, our comparison of these two techniques demonstrates the need for new geothermal geostatistics techniques that combine the advantages of these two methods and that are tailored to the spatial uncertainty issues inherent in geothermal exploration.

15 GEOTHERMAL ENERGY↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Advancing Geophysical Techniques to Image a Stratigraphic Hydrothermal Resource

Sedimentary-hosted geothermal energy systems are permeable structural, structural-stratigraphic, and/or stratigraphic horizons with sufficient temperature for direct use and/or electricity generation. Sedimentary-hosted (i.e., stratigraphic) geothermal reservoirs may be present in multiple locations across the central and eastern Great Basin of the USA, thereby constituting a potentially large base of untapped, economically accessible energy resources. Sandia National Laboratories has partnered with a multi disciplinary group of collaborators to evaluate a stratigraphic system in Steptoe Valley, Nevada using both established and novel geophysical imaging techniques. The goal of this study is to inform an optimized strategy for subsequent exploration and development of this resource and analogous ones. Building from prior Nevada Play Fairway Analysis (PFA), this team is primarily 1) collecting additional geophysical data, 2) employing novel joint geophysical inversion/modeling techniques to update existing 3D geologic models, and 3) integrating the geophysical results to produce a working, geologically constrained thermo-hydrological reservoir model. Prior PFA work highlights Steptoe Valley as a favorable resource basin that likely has both sedimentary and hydrothermal characteristics. However, there remains significant uncertainty on the nature and architecture of the resource(s) at depth, which increases the risk in exploratory drilling. Newly acquired gravity, magnetic, magnetotelluric, and controlled-source electromagnetic data products, in conjunction with new and preexisting geoscientific measurements and observations, are being integrated and evaluated for efficacy in understanding stratigraphic geothermal resources and mitigating exploration risk. Furthermore, the influence of hydrothermal activity on sedimentary-hosted reservoirs in favorable structural settings, and whether fault-controlled systems may locally enhance temperature and permeability in some deep stratigraphic reservoirs, will also be evaluated.

Geothermal, Sedimentary Heat, Geophysics, Seismic,↗

Task Order 22 – Engineering and Technical Support, Deep Borehole Field Test. AREVA Summary Review Report

Under Task Order 22 of the industry Advisory and Assistance Services (A&AS) Contract to the Department of Energy (DOE) DE-NE0000291, AREVA has been tasked with providing assistance with engineering, analysis, cost estimating, and design support of a system for disposal of radioactive wastes in deep boreholes (without the use of radioactive waste). As part of this task order, AREVA was requested, through a letter of technical direction, to evaluate Sandia National Laboratory’s (SNL’s) waste package borehole emplacement system concept recommendation using input from DOE and SNL. This summary review report (SRR) documents this evaluation, with its focus on the primary input document titled: “Deep Borehole Field Test Specifications/M2FT-15SN0817091” Rev. 1 [1], hereafter referred to as the “M2 report.” The M2 report focuses on the conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test waste packages (WPs) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). This SRR follows the same outline as the M2 report, which allows for easy correlation between AREVA’s review comments, discussion, potential proposed alternatives, and path forward with information established in the M2 report. AREVA’s assessment focused on three primary elements of the M2 report: the conceptual design of the WPs proposed for deep borehole disposal (DBD), the mode of emplacement of the WP into DBD, and the conceptual design of the DBFT. AREVA concurs with the M2 report’s selection of the wireline emplacement mode specifically over the drill-string emplacement mode and generically over alternative emplacement modes. Table 5-1 of this SRR compares the pros and cons of each emplacement mode considered viable for DBD. The primary positive characteristics of the wireline emplacement mode include: (1) considered a mature technology; (2) operations are relatively simple; (3) probability of a radiological release due to off-normal events are relatively low; (4) costs are relatively low; and (5) maintenance activities are relatively simple. The primary drawback associated with the wireline emplacement mode for DBD is the number of emplacement trips-in to the borehole, which results in a relatively higher probability for a drop event. Fortunately, the WPs can be engineered with impact limiters that will minimize the likelihood of a breach of the WP due to a drop. The WP designs presented in the M2 report appear to be focused on compatibility with the drill-string emplacement mode (e.g., the threaded connections). With the recommendation that the wireline emplacement mode be utilized for the DBFT, some changes may be warranted to these WPs. For example, the development of a WP release connection that is more reliable than the currently credited connection, which is considered to have a high failure probability, and the integration of an impact limiter into its design. The M2 report states the engineering demonstration of the DBFT will occur in the FTB over a 4-year period. AREVA recommends development and testing of the WP emplacement handling equipment occur separately (but concurrently, if not earlier) from the FTB at a mock-up facility. The separation of this activity would prevent schedule interference between the science and engineering thrusts of the project. Performing tests in a mock-up facility would allow additional control and observation compared to the FTB. The mock-up facility could also be utilized as a training facility for future operations. Terminal velocity and impact limiter testing would require the FTB for testing, since these areas would be difficult to reproduce in a limited depth mock-up. Although only at the end of the conceptual stage of design development, DBD appears to be a viable solution for some waste forms produced by the nuclear industry. However, regulatory requirements have yet to be established for pre- and post-closure performance of DBD and should be established as soon as possible. Some of the main areas of focus from a regulatory perspective include: (1) establishing acceptable performance requirements for the long-term behavior of DBD; (2) determining acceptable borehole abandonment criteria; (3) establishing retrievability requirements; (4) developing a consensus on the factor of safety (FoS) for the emplacement mode and WP; and (5) establishing safety and safeguards performance requirements for DBD. Although conservative requirements have been utilized to provide the foundation for the conceptual design of DBD, regulatory requirements and feedback are necessary to confirm recommendations made herein and to ensure the long-term performance of DBD is acceptable. The combination of the M2 report and this SRR is intended to facilitate the completion of the conceptual design for DBD for the Cs and Sr capsules and calcined waste forms. Using the conceptual design, preliminary design activities (the second stage of a three-stage process described in the M2 report) can proceed and the DBFT utilized to support, demonstrate, and confirm engineering elements of this design.

42 ENGINEERING↗

Evaluation of the Initial Isothermal Physics Measurements at the Fast Flux Test Facility, a Prototypic Liquid Metal Fast Breeder Reactor

The Fast Flux Test Facility (FFTF) was a 400-MWt, sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission reactor plant designed for the irradiation testing of nuclear reactor fuels and materials for the development of liquid metal fast breeder reactors (LMFBRs). The FFTF was fueled with plutonium-uranium mixed oxide (MOX) and reflected by Inconel-600. Westinghouse Hanford Company operated the FFTF as part of the Hanford Engineering Development Laboratory (HEDL) for the U.S. Department of Energy on the Hanford Site near Richland, Washington. Although the FFTF was a testing facility not specifically designed to breed fuel or produce electricity, it did provide valuable information for LMFBR projects and base technology programs in the areas of plant system and component design, component fabrication, prototype testing, and site construction. The major objectives of the FFTF were to provide a strong, disciplined engineering base for the LMFBR program, provide fast flux testing for other U.S. programs, and contribute to the development of a viable self-sustaining competitive U.S. LMFBR industry. During its ten years of operation, the FFTF acted as a national research facility to test advanced nuclear fuels, materials, components, systems, nuclear power plant operating and maintenance procedures, and active and passive reactor safety technologies; it also produced a large number of isotopes for medical and industrial users, generated tritium for the U.S. fusion research program, and participated in cooperative, international research work. Prior to the implementation of the reactor characterization program, a series of isothermal physics measurements were performed; this acceptance testing program consisted of a series of control rod worths, critical rod positions, subcriticality measurements, maximum reactivity addition rates, shutdown margins, excess reactivity, and isothermal temperature coefficient reactivity. The results of these experiments were of particular importance because they provide extensive information which can be directly applied to the design of large LMFBR’s. It should be recognized that the data presented in the initial report were evaluated only to the extent necessary to ensure that adequate data were obtained. Later reports provided further interpretation and detailed comparisons with prediction techniques. The conclusion of the isothermal physics measurements was that the FFTF nuclear characteristics were essentially as designed and all safety requirements were satisfied. From a nuclear point of view, the FFTF was qualified to proceed into power operation mode. The FFTF was completed in 1978 and first achieved criticality on February 9, 1980. Upon completion of the isothermal physics and reactor characterization programs, the FFTF operated for ten years from April 1982 to April 1992. Reactor operations of the FFTF were terminated and the reactor facility was then defueled, deactivated, and placed into cold standby condition. Deactivation of the reactor was put on hold from 1996 to 2000 while the U.S. Department of Energy examined alternative uses for the FFTF but then announced the permanent deactivation of the FFTF in December 2001. Its core support basket was later drilled in May 2005, so as to remove all remaining sodium coolant. On April 17, 2006, the American Nuclear Society designated the FFTF as a “National Nuclear Historic Landmark”.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography Scanning and Geophysical Measurements of the Rogersville Shale from the Smith #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize a core from the Rogersville Shale. This sample was taken from a vertical well, the Jay P. Smith #1 well (47-099-1572), drilled in Wayne County, West Virginia by the Exxon Company in the Elmwood Prospect. The core is comprised primarily of the Rogersville Shale from depths of 11,135 to 11,200.5 ft. This unit is a potential Cambrian oil/gas target, making it of recent interest to multiple groups. The core was provided by the West Virginia Geologic and Economic Survey (WVGES). The primary impetus of this work is a collaboration between WVGES and NETL to characterize core from multiple wells to better understand the structure and variation of key formations in West Virginia (e.g. Crandall et al., 2018a,b). As part of this effort, bulk scans of core were obtained from the Smith #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roger-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Use of DRACS to Enhance HTGRs Passive Safety and Economy

This paper discusses the use of DRACS to Enhance HTGRs Passive Safety and Economy. One of the important requirements for Gen. IV High Temperature Gas Cooled Reactors (HTGR) is passive safety. Currently all the HTGR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. [1] The decay heat first is transferred to core barrel by conduction and radiation, and then to reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. Similar concepts have been widely used in sodium cooled fast reactor (SFR) designs, advanced light water reactors like AP1000. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area. RVACS tends to be less expensive. However, it limits the largest achievable power level for modular HTGRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface). When the relative decay heat removal capability is reduced, the peak fuel temperature increases, even close to the design limit. Annual designs with internal reflector can mitigate this effect therefore further increase the power. Another way to increase power is to increase power density. However, it is also limited by the decay heat removal capability. Besides safety, HTGRs also need to be economical in order to compete with other reactor designs. The limit of decay heat removal capability set by using RVACS has affected the economy of HTGRs. Forsberg [2] pointed out other disadvantages of using RVACS such as conflicting functional requirements for the reactor vessel and scaling distortion for integral effect test of the system performance. A potential alternative solution is to use a volume based passive decay removal system, call Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS has been widely used in SFR designs and in liquid salt cooled high temperature reactors. The containment cooling system in BWR is another example of volume based decay removal systems. DRACS composes of natural circulation loops with two sets of heat exchangers, one in reactor side and another is in environment side. DRACS has the benefits of increasing the power as needed (scalability) and modularity. This paper introduces the concept of using DRACS to enhance HTGRs passive safety and economy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Appalachian Basin Play Fairway Analysis Thermal Risk Factor and Quality Analyses

*This submission revises the analysis and products for Thermal Quality Analysis for the northern half of the Appalachian Basin (https://gdr.openei.org/submissions/638)* This submission is one of five major parts of a Low Temperature Geothermal Play Fairway Analysis. Phase 1 of the project identified potential Geothermal Play Fairways within the Appalachian basin of Pennsylvania, West Virginia and New York. This submission includes a subset of the necessary shapefiles, rasters, datasets, code, and references to code repositories that were used to create the thermal resource and risk factor maps as part of the project. This subset is those contents that were improved upon during calendar year 2016. Figures are provided as examples of some shapefiles and rasters. See also: Final Report: Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (https://gdr.openei.org/submissions/899). The 2015 data submission should be visited to obtain: 1) the regional standardized 1 square km grid used in the project as points (cell centers), polygons, and as a raster, 2) the raw well data for the state well temperature databases, 3) the COSUNA section shapefile and formation thermal conductivities by state as *.xlsx files, 4) the sediment thickness map and 30 m Digital Elevation Model for the Appalachian Basin as GeoTIFF raster files, 5) the BHT correction sections shapefile and drilling fluid databases as *.csv files, 6) the unbuffered interpolation regions as shapefiles, 7) several 50 km buffered interpolation regions as shapefiles, 8) several gridded interpolation regions as raster files, 9) an R script for organizing the thermal data and running the local spatial outlier analysis, 10) shapefiles and rasters for the prediction, uncertainty, and cross validation of the temperature at 1.5 km, 2.5 km, and 3.5 km depth, 11) shapefiles and rasters for the prediction, uncertainty, and cross validation depth to 100 degrees C, 12) an ArcGIS toolbox for thermal risk factor models, 13) an ArcGIS model for extracting results specific to each county of interest, 14) thermal resource cross section plots, 15) the geothermal Play Fairways.

15 GEOTHERMAL ENERGY↗

EGS Collab Earth Modeling: Integrated 3D Model of the Testbed

The EGS Collab project is conducting a series of stimulation and interwell flow tests in an intermediate scale (~10-20 m) testbed located on the 4850 level in the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The testbed consists of eight ~200 ft (~60 m) HQ-diameter (9.6 cm) boreholes that are drilled into the Poorman Formation from the western rib of the West Access Drift. Of the eight boreholes, one borehole is used as an injection/stimulation well, another sub-parallel borehole located about 10 m away from the injection well is used as a production well, and rest of the other boreholes are used as monitoring wells. For 3D visualization of the testbed as well as to provide spatially accurate and consistent parameter data for geomechanical and geophysical process modeling tasks, we are using Leapfrog Software (Seequent Limited). For analysis of fractures and creation of conditioned stochastic discrete fracture network (CS-DFN) model of the testbed, we are using FracMan (Golder Associates Inc.). As of mid-May 2019, the EGS Collab Leapfrog database contains the general layout of the drifts/shafts at the 4850 and 4100 levels; generalized geologic framework model of a domain that spans both the 4850 and 4100 levels; the CS-DFN of the testbed; and layouts of the EGS Collab testbed boreholes, kISMET testbed boreholes, and other existing boreholes at the 4850 level. This information has been obtained from the SURF Vulcan database, detailed laser scan and point surveys of borehole collar locations, directional surveys of borehole trajectories, and mapping of features in the drifts, boreholes, and cores. Similarly, other types of data that have been incorporated into the Leapfrog database include static features of the testbed such as natural discontinuities (e.g., fractures, weeps), location of monitoring instruments, and stimulation notches. Baseline geophysical characterization results (e.g., seismic, ERT, temperature, etc.) are also imported into the Leapfrog database. The location and size of packers, various point-source signals detected during stimulation and flow tests (e.g., temperature anomalies, micro-earthquake events, etc.) are also compiled in the database. All feature locations are reported using the local Homestake Mine coordinate system. In this paper, we present some of the geostructural characteristics as well as the status of the testbed as represented by Leapfrog/FracMan database/visualizations.

15 GEOTHERMAL ENERGY↗

Low Temperature Geothermal Resource Assessment for Membrane Distillation Desalination in the United States: Preprint

Substantial drought and declines in potable groundwater in the United States over the last decade has increased the demand for fresh water. Desalination of saline water such as brackish surface or groundwater, seawater, brines co-produced from oil and gas operations, industrial wastewater, blow-down water from power plant cooling towers, and agriculture drainage water can reduce the volume of water that requires disposal while providing a source of high-quality fresh water for industrial or commercial use. Membrane distillation (MD) is a developing technology that uses low-temperature thermal energy for desalination. Geothermal heat can be an ideal thermal-energy source for MD desalination technology, with a target range of $1/m3 to $2/m3 for desalinated water depending on the cost of heat. Three different cases were analyzed to estimate levelized cost of heat (LCOH) for integration of MD desalination technology with low-grade geothermal heat: (1) residual heat from injection brine at a geothermal power plant, (2) heat from existing underutilized low-temperature wells, and (3) drilling new wells for low-temperature resources. The Central and Western United States have important low-temperature (<90 degrees C) geothermal resource potential with wide geographic distribution, but these resources are highly underutilized because they are inefficient for power production. According to the USGS, there are 1,075 identified low temperature hydrothermal systems, 55 low temperature sedimentary systems and 248 identified medium to high temperature geothermal systems in the United States. The estimated total beneficial heat potential from identified low temperature hydrothermal geothermal systems and residual beneficial heat from medium to high temperature systems is estimated as 36,300 MWth, which could theoretically produce 1.4 to 7 million m3/day of potable water, depending on desalination efficiency.

15 GEOTHERMAL ENERGY↗

Low Temperature Geothermal Resource Assessment for Membrane Distillation Desalination in the United States

Substantial drought and declines in potable groundwater in the United States over the last decade has increased the demand for fresh water. Desalination of saline water such as brackish surface or groundwater, seawater, brines co-produced from oil and gas operations, industrial wastewater, blow-down water from power plant cooling towers, and agriculture drainage water can reduce the volume of water that requires disposal while providing a source of high-quality fresh water for industrial or commercial use. Membrane distillation (MD) is a developing technology that uses low-temperature thermal energy for desalination. Geothermal heat can be an ideal thermal-energy source for MD desalination technology, with a target range of $1/m3 to $2/m3 for desalinated water depending on the cost of heat. Three different cases were analyzed to estimate levelized cost of heat (LCOH) for integration of MD desalination technology with low-grade geothermal heat: (1) residual heat from injection brine at a geothermal power plant, (2) heat from existing underutilized low-temperature wells, and (3) drilling new wells for low-temperature resources. The Central and Western United States have important low-temperature (<90 degrees C) geothermal resource potential with wide geographic distribution, but these resources are highly underutilized because they are inefficient for power production. According to the USGS, there are 1,075 identified low temperature hydrothermal systems, 55 low temperature sedimentary systems and 248 identified medium to high temperature geothermal systems in the United States. The estimated total beneficial heat potential from identified low temperature hydrothermal geothermal systems and residual beneficial heat from medium to high temperature systems is estimated as 36,300 MWth, which could theoretically produce 1.4 to 7 million m3/day of potable water, depending on desalination efficiency.

15 GEOTHERMAL ENERGY↗

Convergence of micro-geochemistry and micro-geomechanics towards understanding proppant shale rock interaction: A Caney shale case study in southern Oklahoma, USA

As a direct outcome of economic development coupled with an increase in population, global energy demand will continue to rise in the coming decades. Although renewable energy sources are increasingly investigated for optimal production, the immediate needs require focus on energy sources that are currently available and reliable, with a minimal environmental impact; the efficient exploration and production of unconventional hydrocarbon resources is bridging the energy needs and energy aspirations, during the current energy transition period. The main challenges are related to the accurate quantification of the critical rock properties that influence production, their heterogeneity and the multiscale driven physico-chemical nature of rock–fluid interactions. A key feature of shale reservoirs is their low permeability due to dominating nanoporosity of the clay-rich matrix. As a means of producing these reservoirs in a cost-effective manner, a prerequisite is creation of hydraulic fracture networks capable of the highest level of continued conductivity. Fracturing fluid chemical design, formation brine geochemical composition, and rock mineralogy all contribute to swelling-induced conductivity damage. The Caney Shale is an organic-rich, often calcareous mudrock. Many studies have examined the impact that clay has on different kinds of shale productivity but there is currently no data reported on the Caney Shale in relation to horizontal drilling; all reported data on the Caney Shale is on vertical wells which are shallow, compared to an emerging play that is at double the depth. Here, in this work we develop geochemical–geomechanical integration of rock properties at micro-and nanoscales that can provide insights into the potential proppant embedment and its mitigation. The novel methodology amalgamates the following: computed X-ray tomography, scanning electron microscopy, energy dispersive spectroscopy, micro-indentation, and Raman spectroscopy techniques. Here, our results show that due to the multiscale heterogeneity in the Caney Shale, these geochemical and structural properties translate into a variation in mechanical properties that will impact interaction between the proppant and the host shale rock.

03 NATURAL GAS↗

Behavior of Particle Depots in Molten Silicon During Float-Zone Growth in Strong Static Magnetic Fields

In the photovoltaics industry, the largest market share is represented by solar cells made from multicrystalline silicon, which is grown by directional solidification. During the growth process, the silicon melt is in contact with the silicon nitride coated crucible walls and the furnace atmosphere which contains carbon monoxide. The dissolution of the crucible coating, the carbon bearing gas, and the carbon already present in the feedstock, lead to the precipitation of silicon carbide, and silicon nitride, at later stages of the growth process. The precipitation of Si3N4 and SiC particles of up to several hundred micrometers in diameter leads to severe problems during the wire sawing process for wafering the ingots. Furthermore the growth of the silicon grains can be negatively influenced by the presence of particles, which act as nucleation sources and lead to a grit structure of small grains and are sources for dislocations. If doped with Nitrogen from the dissolved crucible coating, SiC is a semi conductive material, and can act as a shunt, short circuiting parts of the solar cell. For these reasons, the incorporation of such particles needs to be avoided. In this contribution we performed model experiments in which the transport of intentionally added SiC particles and their interaction with the solid-liquid interface during float zone growth of silicon in strong steady magnetic fields was investigated. SiC particles of 7μm and 60μm size are placed in single crystal silicon [100] and [111] rods of 8mm diameter. This is achieved by drilling a hole of 2mm diameter, filling in the particles and closing the hole by melting the surface of the rod until a film of silicon covers the hole. The samples are processed under a vacuum of 1x10(exp -5) mbar or better, to prevent gas inclusions. An oxide layer to suppress Marangoni convection is applied by wet oxidation. Experiments without and with static magnetic field are carried out to investigate the influence of melt convection on the distribution of particles and their incorporation into the crystal. The field strengths applied by a superconducting magnet are 1T, 3T, 4.5T, and 5T. The increase in field strength dampens the melt flow, and so this study provides comparative data to the crystal growth experiment to be carried out onboard the sounding rocket mission TEXUS 51, where purely diffusive growth condition will be achieved under microgravity conditions.

Jauss, T.↗