Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Applicability of Public Dose Limits to Individuals on the Nevada National Security Site

Historically all persons working on the Nevada National Security Site (NNSS) were considered subject to worker dose limits when calculations of potential dose from the air pathway were conducted to demonstrate compliance with Title 42 United States Code (USC) Chapter 85, “The Clean Air Act,” and Title 40 Code of Federal Regulations (CFR) Part 61, Subpart H, “National Emission Standards for Hazardous Air Pollutants (NESHAP).” Calculations were also conducted for the all-pathways potential dose to demonstrate compliance with U.S. Department of Energy (DOE) Order DOE O 458.1 Chg. 3, “Radiation Protection of the Public and the Environment.” The need to evaluate environmental air sampling locations and past regulator questions about the existence of persons potentially subject to public dose limits being on the NNSS drove this assessment (letter from EPA [U.S. Environmental Protection Agency] Region 9 to DOE/Nevada Operations Office, dated September 3, 1999). This assessment also supports determining those persons subject to public dose limits from the all pathways perspective. A person that is a member of the public is subject to public dose limits.

61 RADIATION PROTECTION AND DOSIMETRY↗

NTS-SS-SNL-NMSITE-2017-0004,"Contamination Monitor Left in Service After Inadequate Calibration" Causes Not Fully Addressed (ES&H Causal Analysis Report)

Sandia National Laboratories Radiation Protection department did not successfully address the causes leading to the issue NTS-SS-SNL-NMSITE-2017-0004, “Contamination Monitor Left in Service After Inadequate Calibration”, nor identify through the verification and validation process that corrective actions were not fully implemented and effective at addressing the issue(s). This report is the third causal in four years associated with the iPCM12 instrument and the Radiation Protection Instrumentation (RPI) organization within Radiation Protection (00628).

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 LANL Radionuclide Air Emissions Report

In June 2020, Los Alamos National Laboratory (LANL) submitted letter ESHQSS: 20-025 to Region 6 of the Unites States Environmental Protection Agency (EPA). This letter transmitted the 2019 LANL Radionuclide Air Emissions Report to the EPA. This report summarizes LANL operations, air emissions of radionuclides, and subsequent off-site dose consequence from these emissions for calendar year 2019. This report is issued to meet requirements of 40 CFR 61 Subpart H, National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Facilities. This regulation, called the Radionuclide NESHAP, establishes a limit of 10 millirem per year to the maximally exposed member of the public and requires an annual report to be submitted to the appropriate EPA Region by June 30th of each year. LANL’s off-site dose from airborne emissions of radionuclides in 2019 was 0.43 millirem. The normal practice is to issue this report directly to EPA Region 6 in June of each year, and then after the report is accepted by the EPA, re-issue the report for inclusion in the LANL Electronic Public Reading Room (EPRR). This second part is usually done in July of each year, but this step was overlooked in July 2020 due to other commitments. We regret this error. This omission was noted in late 2020; we are submitting the 2019 LANL Radionuclide Air Emissions Report to the EPRR now in December 2020. Aside from the addition of this cover sheet explaining the delay, the report is unchanged from the version submitted to EPA Region 6 in June.

54 ENVIRONMENTAL SCIENCES↗

An Investigation of Critical Pit Size in Savy 4000 Wall

The Department of Energy (DOE) issued DOE M 441.1-1, Nuclear Material Packaging Manual, in March 2008 to protect workers who handle nuclear material from exposure due to loss of containment of stored materials. The Manual specifies a detailed approach to achieve high confidence in containers and includes requirements for container design and performance, design-life determinations, material contents, and surveillance and maintenance to ensure container integrity over time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Economic Model for Estimation of GDP Losses in the MACCS Offsite Consequence Analysis Code

The MACCS (MELCOR Accident Consequence Code System) code is the U.S. Nuclear Regulatory Commission (NRC) tool used to perform probabilistic health and economic consequence assessments for atmospheric releases of radionuclides. It is also used by international organizations, both reactor owners and regulators. It is intended and most commonly used for hypothetical accidents that could potentially occur in the future rather than to evaluate past accidents or to provide emergency response during an ongoing accident. It is designed to support probabilistic risk and consequence analyses and is used by the NRC, U.S. nuclear licensees, the Department of Energy, and international vendors, licensees, and regulators. This report describes the modeling framework, implementation, verification, and benchmarking of a GDP-based model for economic losses that has recently been developed as an alternative to the original cost-based economic loss model in MACCS. The GDP-based model has its roots in a code developed by Sandia National Laboratories for the Department of Homeland Security to estimate short-term losses from natural and manmade accidents, called the Regional Economic Accounting analysis tool (REAcct). This model was adapted and modified for MACCS and is now called the Regional Disruption Economic Impact Model (RDEIM). It is based on input-output theory, which is widely used in economic modeling. It accounts for direct losses to a disrupted region affected by an accident, indirect losses to the national economy due to disruption of the supply chain, and induced losses from reduced spending by displaced workers. RDEIM differs from REAcct in its treatment and estimation of indirect loss multipliers, elimination of double counting associated with inter-industry trade in the affected area, and that it is designed to be used to estimate impacts for extended periods that can occur from a major nuclear reactor accident, such as the one that occurred at the Fukushima Daiichi site in Japan. Most input-output models do not account for economic adaptation and recovery, and in this regard RDEIM differs from its parent, REAcct, because it allows for a user-definable national recovery period. Implementation of a recovery period was one of several recommendations made by an independent peer review panel to ensure that RDEIM is state-of-practice. For this and several other reasons, RDEIM differs from REAcct. Both the original and the RDEIM economic loss models account for costs from evacuation and relocation, decontamination, depreciation, and condemnation. Where the original model accounts for an expected rate of return, based on the value of property, that is lost during interdiction, the RDEIM model instead accounts for losses of GDP based on the industrial sectors located within a county. The original model includes costs for disposal of crops and milk that the RDEIM model currently does not, but these costs tend to contribute insignificantly to the overall losses. This document discusses three verification exercises to demonstrate that the RDEIM model is implemented correctly in MACCS. It also describes a benchmark study at five nuclear power plants chosen to represent the spectrum of U.S. commercial sites. The benchmarks provide perspective on the expected differences between the RDEIM and the original cost-based economic loss models. The RDEIM model is shown to consistently predict larger losses than the original model, probably in part because it accounts for national losses by including indirect and induced losses; whereas, the original model only accounts for regional losses. Nonetheless, the RDEIM model predicts losses that are remarkably consistent with the original cost-based model, differing by 16% at most for the five sites combined with three source terms considered in this benchmark.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radioisotope Thermoelectric Generator Accident Pre-Assessed Scenario

This scenario was drafted for inclusion in a revision of Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual, Volume 2 - Pre-Assessed Default Scenarios. The contents of this scenario were reviewed and approved by the FRMAC Assessment Working Group in March 2020. The scenario is being issued separately from the full volume ahead of the Mars 2020 launch. The full volume will be published in the future once all scenarios are complete.

61 RADIATION PROTECTION AND DOSIMETRY↗

MELCOR 2.2 Benchmarks of Peach Bottom NUREG/CR 7155 Uncertainty Analysis

The U.S. Nuclear Regulatory Commission (NRC) performed a first-of-a-kind uncertainty analysis (UA) of the accident progression, radiological releases, and offsite consequences for the State-of- the-Art Reactor Consequence Analyses (SOARCA) of an unmitigated long-term station blackout (LTSBO) severe accident scenario at the Peach Bottom Atomic Power Station. The objective of the UA was to evaluate the robustness of the SOARCA deterministic "best estimate results and conclusions documented in NUREG-1935, and to develop insight into the overall sensitivity of the SOARCA results to uncertainty in key modeling inputs. The study was completed in 2015 and documented in NUREG/CR-7155. Since 2015, two other SOARCA UAs were completed for two pressurized water reactor (PWR) plants. The PWR UAs incrementally updated the approach and methodology, including using the latest release of the MELCOR 2.2 computer code. There were also advances made in the state-of-the-art modeling related to NRC efforts using the Peach Bottom model in NUREG-2206, which provided the technical basis for the containment protection and release reduction rulemaking for boiling water reactors with Mark I and Mark II containments. This report documents the input model changes from the NUREG/CR-7155 study and performs a small number of reference calculations to assess the changes of the new computer code and the model input updates. The objective of the work is to verify whether the updated Peach Bottom MELCOR model and updated version of MELCOR support the conclusions formed in the Peach Bottom SOARCA UA by performing these representative calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NTS-SS-SNL-NMSITE-2017-0004 "Contamination Monitor Left in Service After Inadequate Calibration" Causes Not Fully Addressed (Causal Analysis Report)

On June 5th, 2020 Sandia National Laboratories signed and recommended for closure the evidence package for the Noncompliance Tracking System NTS—SS-SNL-NMSITE-2017-0004, Contamination Monitor Left in Service After Inadequate Calibration. On July 16th, 2020 the Sandia Field Office sent a follow-up question list to the Radiation Protection Instrumentation Program Lead to clarify some points while reviewing the evidence package. The follow-up questions readily identified deficiencies with all three calibrations of the iPCM12 systems. On July 30th, 2020 Radiation Protection hosted a meeting to better understand the exact nature of the concerns, determine if the iPCM12 machines were out of calibration and therefore would have to be taken out of service. One result of this meeting was to determine if SNL could withdraw the evidence package. SNL transmitted a letter on August 26th, 2020 recalling the evidence package and committed to performing a thorough causal analysis and invoke the required issues management processes to ensure that corrective actions are sustained.

54 ENVIRONMENTAL SCIENCES↗