Scalar Flux Profiles in the Unstable Atmospheric Surface Layer Under the Influence of Large Eddies: Implications for Eddy Covariance Flux Measurements and the Non‐Closure Problem

How convective boundary-layer (CBL) processes modify fluxes of sensible (SH) and latent (LH) heat and CO 2 (F c ) in the atmospheric surface layer (ASL) remains a recalcitrant problem. Here, large eddy simulations for the CBL show that while SH in the ASL decreases linearly with height regardless of soil moisture conditions, LH and F c decrease linearly with height over wet soils but increase with height over dry soils. This varying flux divergence/convergence is regulated by changes in asymmetric flux transport between top-down and bottom-up processes. Such flux divergence and convergence indicate that turbulent fluxes measured in the ASL underestimate and overestimate the “true” surface interfacial fluxes, respectively. While the non-closure of the surface energy balance persists across all soil moisture states, it improves over drier soils due to overestimated LH. The non-closure does not imply that F c is always underestimated; F c can be overestimated over dry soils despite the non-closure issue.

Geology↗

Machine Learning Based Prediction of Airflow Maldistribution in A-Type Heat Exchangers

Airflow maldistribution is one of the primary causes of performance degradation in air-to refrigerant heat exchangers (HX) and has been shown to decrease heat transfer by as much as 35%. As a result, many units are oversized to meet the target capacity, resulting in increased system cost and refrigerant charge. Several studies have explored how characteristics like package type and HX geometry impact the flow profile, but results are restricted to a limited range of parameters and cannot be extrapolated to new designs. In this work, a machine learning (ML) model is trained to predict the inlet flow profile of dry air entering A-type HXs across a broad range of geometries and conditions. Flow profiles are generated using a porous media CFD model and used to train an Artificial Neural Network (ANN) which exhibits maximum and average relative L2 norm errors of 0.48 and 0.05. Additionally, these predictions take less than a second to generate resulting in a speed up factor of 2.42E5 compared to CFD. Component-level simulations are conducted to determine the performance degradation resulting from the predicted airflow maldistribution profiles. The new ML model will enable rapid and accurate prediction of performance degradation resulting from airflow maldistribution in A-type HXs, allowing for more accurate and cost-effective HX design.

42 ENGINEERING↗

Characterization of ceramic fuel powder packing fractions to support INFLUX

Triply periodic minimal surface (TPMS)-based structures show marked potential in novel nuclear reactor fuel designs, as their high surface area-to-volume ratio increases the efficiency of heat transfer out of the fuel, enabling safer, more innovative reactor designs. This milestone report addresses the role of dUO 2 powder processing route on the fill behavior of TPMS-based cladding shells to understand and advance the feasibility of manufacturing TPMS-based nuclear fuel forms. dUO 2 powder was processed through either a dry granulation route, varying consolidation pressure, or through milling, varying milling time, milling method and milled size distribution. The lowest tapped bulk densities (TBD), but best powder flowabilities, were obtained when testing unprocessed dUO 2 powder which was prone to self-agglomeration and formed low-density spheroids. The highest TBD and lowest flowabilities were obtained when using powder produced by hammer-milling dUO 2 powder to pass through a 200-mesh sieve, which led to particles with angular morphologies. Powder produced by dry granulation exhibited TBD that varied according to the consolidation pressure used to form the initial pellets and exhibited improved flowabilities when compared to hammer-milled material. Because of the large span of granule sizes formed as well as the irregular shape associated with the granules, a packing fraction of 0.69 was achieved, exceeding the analytical solution for random close packing of mono-sized spheres. TPMS polymer shells were loaded with unprocessed, granulated, and hammer-milled dUO 2 powders, and their qualitative packing behaviors were analyzed using x-ray computed tomography (xCT). TBDs calculated after loading TPMS polymer shells were 10-20% lower when compared to tapped bulk density measurements taken in a glass graduated cylinder, indicating a non-trivial impact on the tapped bulk density of either the TPMS channel size, TPMS channel surface material, powder cohesiveness, or a combination of the two parameters. A metallic zircaloy-4 TPMS shell will be loaded with hammer-milled dUO 2 powder upon receipt of the shell from Oak Ridge National Laboratory (ORNL) and shipped to Idaho National Labs (INL) for subsequent hot isostatic pressing (HIP) densification experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of SRS Aluminum-clad Spent Nuclear Fuel in Standard DOE Sealed Canisters

At the Savannah River Site (SRS), approximately 7 MTHM of aluminum-clad spent nuclear fuel is currently in wet storage at L-basin. A significant portion of this fuel is slated to be dried and sealed in DOE standard canisters for long-term storage. This report will focus on a few fuel types, which should bound all other fuel stored at SRS. These consist of the reference fuel assembly, the MURR fuel and the HFIR fuel. These bound a hypothetical maximum scenario for MTR box fuel, a maximum for decay heat in an assembly, and a maximum for the aluminum surface area, respectively. The geometry for the packages were created from DOE specifications for storage of each of the fuels. As long as the minimum time from reactor discharge to sealed storage is 3 years, then the highest temperatures which occur within the sealed canisters do not exceed 100° C for all scenarios considered here. In the geometry considered, while the HFIR fuel has a large surface area, the packaging configuration leaves large void areas, such that the aluminum surface to free volume ratio is about 30% less than an ATR or MURR packaging configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heating system with induction power supply and electromagnetic acoustic transducer with induction power supply

A system for heating a fluid and an electromagnetic acoustic transducer EMAT system is provided. Both systems have a drive circuit. The amount of heat and the amplitude (and acceleration) of the vibrations is respectively controllable by controlling an input to a terminal of a switch. The heating system comprises a porous graphite foam conductor which is exposed to an electromagnetic field generated by an oscillating circuit. When exposed, the foam conductor conducts induced electric current which heats the same and a fluid in contact with the conductor. The EMAT system comprises at least one magnet configured to generate a static magnetic field, an oscillating circuit and a working element. The working element, when exposed to the static magnetic field and the electromagnetic field produced by the oscillating circuit, vibrates against a load. The vibrations dry the load.

Kisner, Roger A.↗

Data from: "Growth strategies and threshold responses to water deficit modulate effects of warming on tree seedlings from forest to alpine"

This data package contains data that were used to support conclusions drawn in “Growth strategies and threshold responses to water deficit modulate effects of warming on tree seedlings from forest to alpine”, by Lazarus, Castanha et al. 2017. Data were collected at field sites within the Alpine Treeline Warming Experiment (ATWE) on Niwot Ridge, Colorado, USA, and at the U.S. Geological Survey laboratory located in Boise, Idaho. This archive contains comma-separated-values (.csv) files, as well as the same files in Microsoft Excel (.xlsx) format, which can be opened by either Microsoft Excel, R, or any simple text editor program. There are two types of geospatial data files: .kml and ESRI shapefiles (.shp). The kml files contain placemarks, which can be opened by Google Earth, or Google Maps. The ESRI shapefiles can be opened by any geographic information system application that can read shapefiles, including ESRI's entire ArcGIS suite, and QGIS. We asked whether and how tree species differences in response to water deficit relates to their establishment along the gradient from forest to alpine. To do this, we compared growth and moisture stress responses in first-year seedlings of three species planted in common gardens subject to a factorial of heating and watering treatments below, at, and above tree line. This combination of an elevation gradient alongside warming and watering treatments enabled us to observe species differences in seedling responses to a broad set of climatic conditions.Entire seedlings were harvested at c. 3- and again at 9 weeks of age following germination/emergence in the experimental plots, and we then measured dry mass (DM) of above and belowground parts, root length, root mass fraction (RMF), relative growth rates (RGRs) from seed to 3 weeks and from 3 to 9 weeks, turgor-loss point (TLP), and photosynthetic WUE (as δ13C). Also included in this dataset (but not described in the manuscript) are measures of specific leaf area (SLA) and other variables generated by pressure-volume curves (saturated water content, osmotic potential at full turgor, elastic modulus).

54 ENVIRONMENTAL SCIENCES↗

Modeling the First Hydrogen Direct Reduction Pilot Reactor for Ironmaking in the USA Using Finite Element Analysis and Its Validation Using Pilot Plant Trial Data

Direct reduction of hematite pellets with hydrogen (H 2 ) was used to produce directly reduced iron (DRI) in a pilot scale reactor at a pellet feed rate of 21.4 kg/h. At a steady state, operational parameters of the pilot plant (gas recycling rate and inlet temperature) along with key reactor output parameters, the pellet metallization, and the internal temperature profile of the reactor were reported for two scenarios with high recycle and low recycle rate of H 2 . Scenario 1, with a high recycle rate of 400 L/min H 2 along with external heating of 870 °C, gave an average metallization of 91.8%, while Scenario 2, with low recycle rate of 100 L/min H 2 and external heating of 850 °C gave a metallization of 67.8% due to the higher moles of H 2 available for reduction and the external energy required for the endothermic reduction reaction in Scenario 1 as compared with Scenario 2. Finite element analysis was used to build a model of the shaft reactor, which was validated against the metallization and internal temperature profile data. The average metallization values predicted by the model were very close to the metallization values obtained from the pilot plant samples, with 90.9% average metallization for Scenario 1 and 65.6% average metallization for Scenario 2. The internal temperature profiles in the lower region of the reactor obtained from the model were very close to these pilot plant data, with a maximum difference of 52.7 °C and 67.6 °C for Scenarios 1 and 2, respectively. The pilot plant reactor model was used extensively in the commissioning of the pilot plant and to predict the startup outcomes for a given set of operating parameters.

08 HYDROGEN↗

US Geothermal Electricity and Heat Market Analysis and Report

The power production data from FY19 is provided for U.S. geothermal power plants. The spreadsheet includes the plant name and type, nameplate capacity, summer capacity, winter capacity, and net generation for each power plant.

15 GEOTHERMAL ENERGY↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Degradation on Water, Energy, and Carbon Cycling of the Amazon Tropical Forests

Selective logging, fragmentation, and understory fires directly degrade forest structure and composition. However, studies addressing the effects of forest degradation on carbon, water, and energy cycles are scarce. Here, we integrate field observations and high-resolution remote sensing from airborne lidar to provide realistic initial conditions to the Ecosystem Demography Model (ED-2.2) and investigate how disturbances from forest degradation affect gross primary production (GPP), evapotranspiration (ET), and sensible heat flux (H). We used forest structural information retrieved from airborne lidar samples (13,500 ha) and calibrated with 817 inventory plots (0.25 ha) across precipitation and degradation gradients in the eastern Amazon as initial conditions to ED-2.2 model. Our results show that the magnitude and seasonality of fluxes were modulated by changes in forest structure caused by degradation. During the dry season and under typical conditions, severely degraded forests (biomass loss ≥66%) experienced water stress with declines in ET (up to 34%) and GPP (up to 35%) and increases of H (up to 43%) and daily mean ground temperatures (up to 6.5°C) relative to intact forests. In contrast, the relative impact of forest degradation on energy, water, and carbon cycles markedly diminishes under extreme, multiyear droughts, as a consequence of severe stress experienced by intact forests. Our results highlight that the water and energy cycles in the Amazon are driven by not only climate and deforestation but also the past disturbance and changes of forest structure from degradation, suggesting a much broader influence of human land use activities on the tropical ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Radiation-induced dry reforming: A negative emission process

The reaction between the most abundant greenhouse gases (GHG) to produce hydrogen might represent the most powerful and effective decarbonizing opportunity, if a low-carbon energy source is used to drive it. This is the case of methane (CH 4 ) dry reforming (MDR) where its reaction with carbon dioxide (CO 2 ) produces synthesis gas (syngas, a mixture of carbon monoxide and hydrogen). Here this study explores the feasibility of using ionizing radiation to induce the MDR reaction, at low temperatures and/or less energy demanding conditions. Additionally, the ionizing radiation is proposed to be supplied by nuclear power plants (NPPs), which are low-carbon reliable energy generation sources. Thus, the radiolysis of CO 2 , CH 4 and their mixtures, under ?-irradiation was evaluated in the absence and presence of nickel catalysts. The radiation-induced MDR reaction and radiation-induced catalytic promotion were proven to take place at temperatures close to ambient though at low conversion, with yields below 1%. Since irradiation and heat can be provided by a nuclear power plant, this radiation-induced reaction establishes a connection between nuclear energy to renewable resources and enables a pathway for a decarbonized cleaner chemical industry, for producing green chemicals.

08 HYDROGEN↗

Effects of Particle Size and Concentration of Magnesium Oxide on the Lubricating Performance of a Chloride Molten Salt for Concentrating Solar Power

One engineering challenge for the next-generation concentrating solar power (CSP) is to identify appropriate heat transfer and thermal energy storage media. A chloride salt mixture (20 wt % NaCl + 40 wt % MgCl 2 + 40 wt % KCl) in a molten phase is proposed as a potential fluid for carrying the heat as well as lubricating the CSP pump bearings. Due to the hygroscopic nature of MgCl 2 , the presence of magnesium oxide (MgO) particles is inevitable. In order to understand the impact of MgO particles, this study investigated the tribological behavior of the molten chloride salt mixture containing MgO of various particle sizes and concentrations. Tests were conducted at 750 °C in a dry Ar environment using a zirconia ball sliding against a Haynes 244 alloy disc lubricated by the molten salt. There was a clear trend of the increased friction coefficient and wear loss for a larger particle size and/or a higher concentration of MgO. Distinct wear mechanisms were identified for the ceramic ball and alloy disc. Results provide fundamental insights for this new research avenue of molten salt lubrication for CSP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoengineering Porous Silica for Thermal Management

Thermal insulation of solid materials originates from the nanoscale porous architectures to regulate thermal management in energy-critical applications from energy-efficient buildings to heat-sensitive energy devices. Here, we show nanoengineering of porous silica materials to control the architecture transition from mesoporous to nanocage networks. A low thermal conductivity of such a porous silica network is achieved at 0.018 W/(m K) while exhibiting a porosity of 92.05%, specific surface area of 504 m 2 /g, and pore volume of 2.37 cm 3 /g after ambient pressure drying. Meanwhile, the crosslinking of the porous silica and ceramic fiber frameworks show a tensile Young’s modulus of 2.8 MPa while maintaining high thermal insulation, which provides an effective thermal runway mitigation strategy for rechargeable lithium-ion batteries. Furthermore, the nanoengineering strategy reported here would shed light on achieving superthermal insulation of nanostructures for energy-critical applications.

36 MATERIALS SCIENCE↗

Aerogel from Sustainably Grown Bacterial Cellulose Pellicles as a Thermally Insulative Film for Building Envelopes

Improving building energy performance requires the development of new highly insulative materials. An affordable retrofitting solution comprising a thin film could improve the resistance to heat flow in both residential and commercial buildings and reduce overall energy consumption. Here, we propose cellulose aerogel films formed from pellicles produced by the bacteria Gluconacetobacter hansenii as insulation materials. We studied the impact of the density and nanostructure on the aerogels’ thermal properties. A thermal conductivity as low as 13 mW/(K·m) was measured for native pellicle-based aerogels that were dried as-is with minimal post-treatment. The use of waste from the beer brewing industry as a solution to grow the pellicle maintained the cellulose yield obtained with standard Hestrin-Schramm media, making our product more affordable and sustainable. In the future, our work can be extended through further diversification of food wastes as the substrate sources, facilitating higher potential production and larger applications.

36 MATERIALS SCIENCE↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

Optimization of a High Pressure Turbine Blade and Sector-Based Annular Rig Design for Supercritical CO2 Power Cycle Representative Testing

Abstract As part of the ongoing research into the design of hardware for zero emission cycles, a first-stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design three-dimensional with objectives of increasing efficiency and decreasing heat load to the blade. Supercritical CO2 property tables are constructed from NIST REFPROP data for the condensable gas simulation in FINE/Turbo. A detailed mesh sensitivity study is performed for a baseline design to identify the proper-grid refinement and efficiently allocate resources for the optimization. Seventy design variables are selected for the initial population generation. Self-organizing maps are then used to focus the design variables on the most important ones affecting the objective functions. The optimization results in approximately 3000 three-dimensional Reynolds Averaged Navier Stokes simulations of different blade shapes with increases in efficiency of up to 0.85% and decreases in heat load of 14%. Families of blade shapes are identified for experimental testing in an annular rig at the Purdue Experimental Turbine Aerothermal Laboratory. A design to adapt the annular cascade for testing optimized geometries is introduced, which features eccentric radius sectors allowing for scaled-up geometries of sCO2 optimized blade profiles to be tested at design cycle representative conditions at high Reynolds numbers in dry air. Analysis into the effects of Reynolds number, working fluid, and geometric relations are presented to prove the efficacy of the test method.

Engineering↗

Process-informed adsorbent design guidelines for direct air capture

Direct air capture using solid adsorbents is a proven technology critical to reducing our net greenhouse gas emissions to zero and beyond. Currently, academic research into the technology mainly focuses on the development of new adsorbents. However, there is a discord between the adsorbent design and process performance. Many materials scientists focus on maximising metrics such as the CO 2 capacity of their adsorbent. Here, we combine detailed process modelling, machine learning, and extensive global sensitivity analysis, which entails varying all of the model parameters together, on a direct air capture process to show that the dry CO 2 adsorption capacity does not influence process performance for an amine-functionalised adsorbent operating in a temperature vacuum swing adsorption (TVSA) process, while it is important in a steam-assisted TVSA (S-TVSA) process. In fact, adsorption kinetics, density, and thermal conductivity are all critical attributes to obtaining a low energy penalty and reduced costs. The analysis also highlights the importance of heat transfer, directing process engineers to (alternative) adsorber designs that maximise this. By an in-depth evaluation of how process performance indicators are affected by materials properties and process operating parameters, this work provides guidance to both material scientists and process engineers towards the design of a “unicorn adsorbent” and intensified DAC processes. This will improve the performance of solid adsorbent direct air capture and help drive down the costs of this vital technology to avert the worst impacts of climate change.

42 ENGINEERING↗

The toughest animals of the Earth versus global warming: Effects of long‐term experimental warming on tardigrade community structure of a temperate deciduous forest

Abstract Understanding how different taxa respond to global warming is essential for predicting future changes and elaborating strategies to buffer them. Tardigrades are well known for their ability to survive environmental stressors, such as drying and freezing, by undergoing cryptobiosis and rapidly recovering their metabolic function after stressors cease. Determining the extent to which animals that undergo cryptobiosis are affected by environmental warming will help to understand the real magnitude climate change will have on these organisms. Here, we report on the responses of tardigrades within a five‐year‐long, field‐based artificial warming experiment, which consisted of 12 open‐top chambers heated to simulate the projected effects of global warming (ranging from 0 to 5.5°C above ambient temperature) in a temperate deciduous forest of North Carolina (USA). To elucidate the effects of warming on the tardigrade community inhabiting the soil litter, three community diversity indices (abundance, species richness, and Shannon diversity) and the abundance of the three most abundant species ( Diphascon pingue , Adropion scoticum , and Mesobiotus sp.) were determined. Their relationships with air temperature, soil moisture, and the interaction between air temperature and soil moisture were tested using Bayesian generalized linear mixed models. Despite observed negative effects of warming on other ground invertebrates in previous studies at this site, long‐term warming did not affect the abundance, richness, or diversity of tardigrades in this experiment. These results are in line with previous experimental studies, indicating that tardigrades may not be directly affected by ongoing global warming, possibly due to their thermotolerance and cryptobiotic abilities to avoid negative effects of stressful temperatures, and the buffering effect on temperature of the soil litter substrate.