Search NASA⌕ Search

SEARCH · Search NASA

Results for “Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Hardware device binding and mutual authentication

Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

97 MATHEMATICS AND COMPUTING↗

Communication device with persistent configuration and verification

The present disclosure pertains to systems and methods for establishing communication with a remote communication device in a software defined network (SDN) during time when an SDN controller is unavailable. In one embodiment, a local communication device may be configured to receive a plurality of data flows from an SDN controller and to store the plurality of data flows in a persistent data memory. The device may generate a unique identifier for the local communication device that is transmitted to a remote communication device. Following a disruption the results in the SDN controller being unavailable, the local communication device may recover into a default configured state based on the plurality of data flows in the persistent data memory. The local communication device may then transmit the unique identifier to the remote communication device after the disruption to begin a process of reestablishing communication with the remote communication device.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems and methods for quantum optical device authentication

Quantum optical device authentication technologies are described herein. A first device includes an optical transmitter transmits a plurality of pulses to an optical receiver included on a second device. The optical pulses each have one of two non-orthogonal optical states. The optical receiver measures each of the pulses and the second device records a measured value of the optical state of each pulse. Subsequently, the second device transmits the measured values of the optical states of the pulses to the first device. The first device outputs an indication of whether the second device is authenticated based upon the measured values received from the second device and the optical states of the pulses transmitted by the optical transmitter.

Soh, Daniel Beom Soo↗

Electrostatic harvester device

An electrostatic harvester device for charging an energy storage device is provided. The electrostatic harvester device comprises an inductor, a variable capacitor device, a semiconductor device, and a plurality of transistors. The inductor is operable to receive electric charge and store the electric charge. The variable capacitor device is configured to receive electric charge from the inductor and to change capacitance in response to physical stimulation. The semiconductor device is operable to allow electric current to flow from the variable capacitor device. The transistors are operable to connect at least two of the aforementioned devices. At least one of the transistors comprises at least one of gallium nitride or aluminum gallium nitride.

Wilson, Amy Charlene↗

Position sensing circuit for an electrostatically driven MEMS device

The present disclosure relates to a system for detecting movement of a microelectromechanical system (MEMS) device. The system uses a drive voltage signal source for generating a low frequency drive voltage signal for driving the MEMS device. An excitation signal source may be used for generating an excitation signal which is also applied to the MEMS device. The excitation signal has a frequency which is above a physical response capability of the MEMS device, such that operation of the MEMS device is not significantly affected by the excitation signal. A sensing impedance is used to help generate a signal which is responsive to the capacitance of the MEMS device. The capacitance of the MEMS device changes in response to movement of the MEMS device. An output subsystem is provided which responds to changes sensed by the sensing impedance, and which produces an output voltage signal. A filter filters the output voltage signal to produce a filtered output voltage signal. The filtered output voltage signal is indicative of a position of the MEMS device.

Panas, Robert Matthew↗

Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

2D nanocomposite of hexagonal boron nitride nanoflakes and molybdenum disulfide quantum dots applied as the functional layer of all-printed flexible memory device

Highlights: • We have proposed a flexible, rewritable and NVM device based on an advanced 2D nanocomposite. • 2D nanocomposite is synthesized by mixing hBN flakes and MoS{sub 2} QDs. • Entire device was fabricated through extremely simple and highly controllable printing technology. • The RRAM device was tested electrically, mechanically, thermally and chemically. - Abstract: In this study, we have proposed a flexible, rewritable and nonvolatile memory device based on an advanced 2D nanocomposite of hexagonal boron nitride (hBN) flakes and molybdenum disulfide quantum dots (MoS{sub 2} QDs). Complete device fabrication was carried out by using extremely simple and highly controllable all printed technology. The electrical characteristics exhibited by the as developed memory devices included the switching ratio, electrical endurance and retention time of ∼10{sup 3}, 10{sup 3} and 10{sup 4} respectively. The device turned ON and OFF at the SET and RESET threshold voltages of +1.4 V and −1 V respectively. The obtained results of electrical and thermal characterizations exhibited that the switching ratio decreases via either increasing temperature (300 K–380 K) or device size (42 μm–100 μm) hence verifying the formation of conductive filament through the functional layer. Moreover, no major degradation in the switching characteristics was observed even after 1500 bending cycles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Parameter extraction from I-V characteristics of PV devices

Device parameters such as series and shunt resistances, saturation current and diode ideality factor influence the behaviour of the current-voltage (I-V) characteristics of solar cells and photovoltaic modules. It is necessary to determine these parameters since performance parameters are derived from the I-V curve and information provided by the device parameters are useful in analyzing performance losses. This contribution presents device parameters of CuIn(Se,S){sub 2}- and Cu(In,Ga)(Se,S){sub 2}-based solar cells, as well as, CuInSe{sub 2}, mono- and multicrystalline silicon modules determined using a parameter extraction routine that employs Particle Swarm Optimization. The device parameters of the CuIn(Se,S){sub 2}- and Cu(In,Ga)(Se,S){sub 2}-based solar cells show that the contribution of recombination mechanisms exhibited by high saturation current when coupled with the effects of parasitic resistances result in lower maximum power and conversion efficiency. Device parameters of photovoltaic modules extracted from I-V characteristics obtained at higher temperature show increased saturation current. The extracted values also reflect the adverse effect of temperature on parasitic resistances. The parameters extracted from I-V curves offer an understanding of the different mechanisms involved in the operation of the devices. The parameter extraction routine utilized in this study is a useful tool in determining the device parameters which reveal the mechanisms affecting device performance. (author)

14 SOLAR ENERGY↗

ISOS-3 Inter-Laboratory Collaboration Focused on the Stability of a Variety of Organic Photovoltaic Devices

Seven distinct sets (n {>=} 12) of state of the art organic photovoltaic devices were prepared by leading research laboratories in a collaboration planned at the Third International Summit on Organic Photovoltaic Stability (ISOS-3). All devices were shipped to RISO DTU and characterized simultaneously up to 1830 h in accordance with established ISOS-3 protocols under three distinct illumination conditions: accelerated full sun simulation; low level indoor fluorescent lighting; and dark storage with daily measurement under full sun simulation. Three nominally identical devices were used in each experiment both to provide an assessment of the homogeneity of the samples and to distribute samples for a variety of post soaking analytical measurements at six distinct laboratories enabling comparison at various stages in the degradation of the devices. Over 100 devices with more than 300 cells were used in the study. We present here design and fabrication details for the seven device sets, benefits and challenges associated with the unprecedented size of the collaboration, characterization protocols, and results both on individual device stability and uniformity of device sets, in the three illumination conditions.

14 SOLAR ENERGY↗

Advanced Stress, Strain And Geometrical Analysis In Semiconductor Devices

High stresses and defect densities increases the risk of semiconductor device failure. Reliability studies on potential failure sources have an impact on design and are essential to assure the long term functioning of the device. Related to the dramatically smaller volume of semiconductor devices and new bonding techniques on such devices, new methods in testing and qualification are needed. Reliability studies on potential failure sources have an impact on design and are essential to assure the long term functioning of the device. In this paper, the applications of advanced High Resolution X-ray Diffraction (HRXRD) methods in strain, defect and deformation analysis on semiconductor devices are discussed. HRXRD with Rocking Curves (RC's) and Reciprocal Space Maps (RSM's) is used as accurate, non-destructive experimental method to evaluate the crystalline quality, and more precisely for the given samples, the in-situ strain, defects and geometrical parameters such as tilt and bending of device. The combination with advanced FEM simulations gives the possibility to support efficiently semiconductor devices design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Device-Level Thermal Management of Gallium Oxide Field-Effect Transistors

The ultra-wide bandgap (~4.8 eV) and melt-grown substrate availability of β-Ga 2 O 3 gives promise to the development of next generation power electronic devices with dramatically improved size, weight, power, and efficiency over current state-of-the-art wide bandgap devices based on 4H-SiC and GaN. Also, with recent advancements made in GHz frequency RF applications, the potential for monolithic or heterogenous integration of RF and power switches has attracted researchers’ attention. Yet, it is expected that Ga 2 O 3 devices will suffer from self-heating due to the poor thermal conductivity of the material. Thermoreflectance thermal imaging and infrared thermography were used to understand the thermal characteristics of a MOSFET fabricated via homo-epitaxy. A 3D coupled electro-thermal model was constructed based on the electrical and thermal characterization results. The device model shows that a homo-epitaxial device suffers from an unacceptable junction temperature rise of ~1500°C under a targeted power density of 10 W/mm indicating the importance of employing device level thermal managements to individual Ga 2 O 3 transistors. The effectiveness of various active and passive cooling solutions was tested to achieve a goal of reducing the device operating temperature below 200°C at a power density of 10 W/mm. Results show that flip-chip hetero-integration is a viable option to enhance both the steady-state and transient thermal characteristics of Ga 2 O 3 devices without sacrificing the intrinsic advantage of high-quality native substrates. Also, it is not an active thermal management solution that entails peripherals requiring additional size and cost implications.

42 ENGINEERING↗

Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in the study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.

control room modernization↗

In Situ Study of Resistive Switching in a Nitride‐Based Memristive Device

Abstract Resistive switching (RS) devices with ultra‐low‐voltage threshold and reliable switching repeatability exhibits great potential applications in energy‐efficient data storage and neuromorphic computing. Understanding switching mechanisms at nanoscale is critical to design RS devices with improved performance. In this work, a lamella memristive device using focused ion beam (FIB) method based on the metal/TiO x /TiN/Si structure device is fabricated. In situ transmission electron microscopy (TEM) and current–voltage ( I–V ) characteristic demonstrate that the lamella device shows a volatile RS behavior with a threshold switching at ≈ ± 0.4 V. In situ scanning transmission electron microscopy (STEM) experiments with electron energy loss spectroscopy (EELS) reveal that the charge carriers such as oxygen vacancies migrate under positive/negative DC bias and modulate Schottky barriers at the top and bottom metal/semiconductor interfaces. The RS mechanism of the lamella device is based on the Schottky barriers modulation and Joule heating assisted electric field triggered thermal runaway (FTTR) occurred at the metal/semiconductor interfaces. The fundamental insights gained from this study presents a perspective on interface‐type RS devices processing and opens up new technological opportunities of fabricating ultra‐low‐energy memristive devices.

36 MATERIALS SCIENCE↗

New European Regulation for Medical Devices: What Is Changing?

Introduction: The Medical Devices Regulation (MDR) 2017/745/EU will fully apply from May 2020. Interventional radiologists use medical devices on a daily basis and so must be aware of the impact that this new regulation will have on their daily practice. Materials and Methods: In this paper, we describe the major transformation that the MDR brings to the medical devices sector, with a focus on clinical evaluations and clinical investigations. Results: This regulation significantly tightens controls to ensure that devices are safe and effective. In addition, equivalence to already existing devices, which allowed an accelerated access to the market, will now be possible only in some cases. Furthermore, post-marketing clinical follow-up is extended under the MDR and is required for all devices. These new requirements will probably lead to a dramatic increase in the number of clinical investigations and also to a delay in the availability of certain devices on the market. Conclusions: In the coming years, interventional radiologists are likely to be affected by these changes in their daily practice, in terms of medical device availability and/or in terms of increased involvement in clinical investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selective excitation of window and buffer layers in chalcopyrite devices and modules

Window and buffer layers in chalcopyrite devices are well known to affect junctions, conduction, and photo-absorption properties of the device. Some of these layers, particularly 'buffers,' which are deposited directly on top of the absorber, exhibit metastable effects upon exposure to light. Thus, to understand device performance and/or metastability, it is sometimes desirable to selectively excite different layers in the device stack. Absorption characteristics of various window and buffer layers used in chalcopyrite devices are measured. These characteristics are compared with emission spectra of common and available light sources that might be used to optically excite such layers. Effects of the window and buffer absorption on device quantum efficiency and metastability are discussed. For the case of bath-deposited Zn(O,S) buffers, we conclude that this layer is not optically excited in research devices or modules. Furthermore, this provides a complimentary mechanism to the chemical differences that may cause long time constants (compared to devices with CdS buffers) associated with reaching a stable 'light-soaked' state.

14 SOLAR ENERGY↗