Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Influence of ponderomotive force on the microwave and plasma interaction in an elliptical waveguide

The interaction effect of a high-power microwave with the plasma in an elliptical waveguide taking into account the ponderomotive force is presented. Here, we assume the fundamental mode that propagates in an evacuated elliptical waveguide and encounters a plasma, which is filled in another elliptical waveguide of the same size. Here, we consider a balance between the effects of ponderomotive force and the electron pressure and consider the plasma effect through its dielectric permittivity because the electron density distribution of the plasma is modified. The propagation of the mode is described by two nonlinear coupled differential equations obtained using the Maxwell's equations. These equations are solved numerically using fourth order Runge-Kutta method for the field amplitude of the microwave in the waveguide considering the waveguide to be made up of a perfect conductor and filled with homogeneous plasma density distribution. The effects of the electron temperature, the microwave filed, and the frequency on the perturbed density profile are studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of ECRH project on EAST Tokamak

A 140GHz electron cyclotron resonance heating and current drive (EC H and CD) project for EAST Tokamak is launched in 2011 with a total power of 4MW and pulse length of 100 s. The main objectives of the system are to provide central H and CD, assist start-up and control of MHD activities. The system comprises four gyrotrons each with nominal output power of 1MW at 140GHz. The RF power, transmitted through four evacuated corrugated waveguides will be injected into plasma from the low field side (radial port). The front steering equatorial launcher directs the RF beam over ±25° toroidally and scans over 38° poloidally. At present, the construction of the first 1MW system is undergoing for the expected campaign in the end of 2013. In this paper, the current status of the development and the design of the 140-GHz ECRH system are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High power test of a wideband diplexer with short-slotted metal half mirrors for electron cyclotron current drive system

The wideband high power diplexer has been developed for combining and fast switching of high power millimeter waves generated by a dual frequency gyrotron. The actual diplexer was tested at the frequency band of 170 GHz in low power. After adjusting a resonant frequency of diplexer for the gyrotron frequency, the evacuated wideband diplexer with short-slotted metal half mirrors was tested at an incident power of about 150 kW, a pulse duration of 30 ms and a frequency band of 170.2–170.3 GHz. Any discharge damage was not observed in the diplexer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defects and persistent conductivity in SrTiO{sub 3}

Strontium titanate (SrTiO{sub 3}) is often used as a substrate for oxide thin films such as high-temperature superconductors. It has the perovskite structure and an indirect band gap of 3.25 eV. Our prior work showed that hydrogen impurities form a defect complex that contains two hydrogen atoms. The complex was tentatively attributed to a passivated strontium vacancy. Alternatively, it could be a partially passivated titanium vacancy. In order to create titanium vacancies, we annealed samples in an evacuated ampoule with SrO powder. These samples show unexpected behavior. After illuminating with sub-gap light, the free-electron concentration increases significantly. After the light is turned off, the high conductivity persists at room temperature. We attribute persistent photoconductivity (PPC) to the excitation of an electron from a vacancy into the conduction band, with a low recapture rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Color-based tracking of plasma dust particles

Color-based tracking to observe agglomeration of deposited particles inside a compact planar magnetron during plasma discharge was done by creating high dynamic range (HDR) images of photos captured by a Pentax K10D digital camera. Carbon erosion and redeposition was also monitored using the technique. The HDR images were subjected to a chromaticity-based constraint discoloration inside the plasma chamber indicating film formation or carbon redeposition. Results show that dust deposition occurs first near the evacuation pumps due to the pressure gradient and then accumulates at the positively charged walls of the chamber. This method can be applied to monitor dust formation during dusty plasma experiments without major modification of plasma devices, useful especially for large fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of the EUV emission of a metallic capillary discharge operated with argon ambient gas

In this work, the metallic capillary discharge is operated with two different ambients: air and argon. In the experiments reported here, the chamber is first evacuated to 10{sup −5} mbar. The discharge is initiated by the transient hollow cathode effect generated electron beam, with either air ambient or argon ambient at 10{sup −4} mbar. The bombardment of electron beam at the tip of the stainless steel anode gives rise to a metallic vapor, which is injected into the capillary and initiates the main discharge through the capillary. The EUV emission is measured for different discharge voltages for both conditions and compared. It is found that the metallic capillary discharge with argon ambientis able to produce higher EUV energy compared to that with air ambient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma actuator electron density measurement using microwave perturbation method

A cylindrical dielectric barrier discharge plasma under five different pressures is generated in an evacuated glass tube. This plasma volume is located at the center of a rectangular copper waveguide cavity, where the electric field is maximum for the first mode and the magnetic field is very close to zero. The microwave perturbation method is used to measure electron density and plasma frequency for these five pressures. Simulations by a commercial microwave simulator are comparable to the experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of gastric emptying time (GET) in clownfish (Amphiprion ocellaris) using X-radiography technique

This study examines the movement of food item and the estimation of gastric emptying time using the X-radiography techniques, in the clownfish (Amphiprion ocellaris) fed in captivity. Fishes were voluntarily fed to satiation after being deprived of food for 72 hours, using pellets that were tampered with barium sulphate (BaSO{sub 4}). The movement of food item was monitored over different time of feeding. As a result, a total of 36 hours were needed for the food items to be evacuated completely from the stomach. Results on the modeling of meal satiation were also discussed. The size of satiation meal to body weight relationship was allometric, with the power value equal to 1.28.

60 APPLIED LIFE SCIENCES↗

Identification of slip surface location by TLS-GPS datafor landslide mitigation case study: Ciloto-Puncak, West Java

Landslide can prevented by understanding the direction of movement to the safety evacuation track or slip surface location to hold avalanches. Slip surface is separating between stable soil and unstable soil in the slope. The slip surface location gives information about stable material depth. The information can be utilize to mitigate technical step, such as pile installation to keep construction or settlement safe from avalanches.There are two kinds landslide indicators which are visualization and calculation. By visualization, landslide identified from soil crack or scarp. Scarp is a scar of exposed soil on the landslide. That identification can be done by Terrestrial Laser Scanner (TLS) Image. Shape of scarp shows type of slip surface, translation or rotational. By calculation, kinematic and dynamic mathematic model will give vector, velocity and acceleration of material movement. In this calculation need velocity trend line at GPS point from five GPS data campaign. From intersection of trend lines it will create curves or lines of slip surface location. The number of slip surface can be known from material movement direction in landslide zone.Ciloto landslide zone have complicated phenomenon because that zone have influence from many direction of ground water level pressure. The pressure is causes generating several slip surface in Ciloto zone. Types of Ciloto slip surface have mix between translational and rotational type.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Cs vapor cell coated with octadecyltrichlorosilane using coherent population trapping spectroscopy

We report the realization and characterization using coherent population trapping (CPT) spectroscopy of an octadecyltrichlorosilane (OTS)-coated centimeter-scale Cs vapor cell. The dual-structure of the resonance lineshape, with presence of a narrow structure line at the top of a Doppler-broadened structure, is clearly observed. The linewidth of the narrow resonance is compared to the linewidth of an evacuated Cs cell and of a buffer gas Cs cell of similar size. The Cs-OTS adsorption energy is measured to be (0.42 ± 0.03) eV, leading to a clock frequency shift rate of 2.7 × 10{sup −9}/K in fractional unit. A hyperfine population lifetime, T{sub 1}, and a microwave coherence lifetime, T{sub 2}, of 1.6 and 0.5 ms are reported, corresponding to about 37 and 12 useful bounces, respectively. Atomic-motion induced Ramsey narrowing of dark resonances is observed in Cs-OTS cells by reducing the optical beam diameter. Ramsey CPT fringes are detected using a pulsed CPT interrogation scheme. Potential applications of the Cs-OTS cell to the development of a vapor cell atomic clock are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pre-conditioning procedure suitable for internal-RF-antenna of J-PARC RF-driven H{sup −} ion source

The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H{sup −} ion source has been successfully operated for about 1 yr. By the world brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. Although no internal-RF-antenna failure, except for the once caused by an excess cesium due to a misoperation, occurred in the operation, many antennas failed in pre-conditionings for the first hundred days. The antenna failure rate was drastically decreased by using an antenna with coating thicker than a standard value and the pre-conditioning procedure repeating 15 min 25 kW RF-power operation and impurity-gas evacuation a few times, before the full power (50 kW) operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on long pulse ECRH system of EAST in support of ITER

Experimental Advanced Superconducting Tokamak (EAST), as a fully superconducting tokamak in China, aims to achieve high performance plasma under steady-state operation. To fulfill the physical objectives of EAST, a program of 4-MW long pulse electron cyclotron resonance heating and current drive (EC H&CD) system, which would offer greater flexibility for plasma shape and plasma stabilization has been launched on EAST since 2011. The system, composed of 4 gyrotrons with nominal 1MW output power and 1000s pulse length each, is designed with the feature of steerable power handling capabilities at 140 GHz, using second harmonic of the extraordinary mode(X2). The missions of the ECRH system are to provide plasma heating, current drive, plasma profile tailoring and control of magneto-hydrodynamic (MHD) instabilities. Presently, the first two 140-GHz 1-MW gyrotrons, provided by GYCOM and CPI, respectively, have been tested at long pulse operation. The tubes, the associated power supplies, cooling system, cryogenic plant, 2 transmission lines and an equatorial launcher are now installed at EAST. The power generated from each tube will be transmitted by an evacuated corrugated waveguide transmission line and injected into plasma from the low field side (radial port) through a front steering equatorial launcher. Considering the diverse applications of the EC system, the beam’s launch angles can be continuously varied with the optimized scanning range of over 30° in poloidal direction and ±25° in toroidal, as well as the polarization could be adjusted during the discharge by the orientations of a pair of polarizers in the transmission line to maintain the highest absorption for different operational scenarios. The commissioning of the first 2MW ECRH plant for EAST is under way. The design, R&D activities and recent progress of the long pulse 140-GHz ECRH system are presented in this paper. As the technological requirements for EAST ECRH have many similarities with ITER devices, the installation and experience of EAST ECRH system may provide valuable data for the ITER.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spherical fused silica cells filled with pure helium for nuclear magnetic resonance-magnetometry

High magnetic fields (>1 T) are measured by NMR magnetometers with unrivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted {sup 3}He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field, the optimal container for the {sup 3}He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO{sub 2} laser and the inner volume was filled with a few mbars of {sup 3}He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with <1 μm deviation from sphericity, the bonding left a step of ca. 50 μm at maximum. The influence of such a mismatch, its orientation, and the immediate environment of the sample is analyzed by FEM-simulations and discussed in view of coherence times and absolute field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of annealing temperature on structure and electrical properties of topological insulator Bi{sub 2}Te{sub 3}

Bi{sub 2}Te{sub 3} samples were prepared by precipitation method. The samples were annealed in evacuated quartz tubes and were treated at different temperature for different duration of time. Effects of annealing temperature and time on the structure of Bi{sub 2}Te{sub 3} were studied in detail. The Bi{sub 2}Te{sub 3} samples annealed at temperature 300°C and 450°C for 48Hrs, 72Hrs and 96Hrs were selected for the present study. The structure of Bi{sub 2}Te{sub 3} and related phases were investigated by the X-ray powder diffraction technique. Morphology and chemical compositions of the samples were investigated by scanning electron microscope and energy dispersive X-ray spectroscopy respectively. All the samples were indexed in rhombohedral crystal structure, with a space group R-3m. The structure consists of repeated quintuple layers of atoms, Te2-Bi-Te1-Bi-Te2 stacking along the z-axis of the unit cell. Electrical properties of the sample annealed at 300°C for 96Hrs was evaluated by measurements of the electrical resistivity and magnetoresistance. The magnetoresistance data at low temperature (1.5 to 50 K) were analyzed to investigate weak antilocalization (WAL) effect. MR data followed the Hikami–Larkin–Nagaoka (HLN) equation with a fit parameter α close to −1 as expected for topological surface states at 1.5 K, but for other temperatures the small oscillations were observed which may be due to the phenomena like Shubnikov-de Hass effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-linear theory of a cavitated plasma wake in a plasma channel for special applications and control

We introduce a complete semi-analytical model for a cavitated electron wake driven by an electron beam in a radially inhomogeneous plasma. The electron response to the driver, dynamics of electrons in a thin sheath surrounding the cavity, as well as accelerating and focusing fields inside the cavity are calculated in the quasistatic approximation. Our theory holds for arbitrary radial density profiles and reduces to known models in the limit of a homogeneous plasma. A free-propagating blow-out in an evacuated channel experiences longitudinal squeezing, qualitatively the same as observed in particle-in-cell simulations for the laser pulse-driven case [Pukhov et al., Phys. Rev. Lett. 113, 245003 (2014)]. Our model also permits qualitative interpretation of the earlier observed cancellation of the focusing gradient in the cavity [Pukhov et al., Phys. Rev. Lett. 113, 245003 (2014)]. In this work, we show the underlying mechanism that causes the radial fields in the vacuum part of a channel to become defocussing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An upgrade beamline for combined wide, small and ultra small-angle x-ray scattering at the ESRF

This contribution presents the main design features of the upgraded beamline ID02 (TRUSAXS). The beamline combines different small-angle X-ray scattering techniques in one unique instrument. The key component of this instrument is an evacuated (5×10{sup −3} mbar) stainless steel detector tube of length 34 m and diameter 2 m. Three different detectors (Rayonix MX170, Pilatus 300 K and FReLoN 4M) are housed inside a motorized wagon which travels along a rail system with very low parasitic lateral movements (± 0.3 mm). This system allows automatically changing the sample-to-detector distance from about 1 m to 31 m and selecting the desired detector. In addition, a wide angle detector (Rayonix LX170) is installed just above the entrance cone of the tube for optional wide-angle X-ray scattering measurements. The beamstop system enables monitoring of the X-ray beam intensity in addition to blocking the primary beam, and automated insertion of selected masks behind the primary beamstop. The focusing optics and collimation system permit to cover a scattering vector (q) range of 0.002 nm{sup −1} ≤ q ≤ 50 nm{sup −1} with one unique setting using 0.1 nm X-ray wavelength for moderate flux (5×10{sup 12} photons/sec). However, for higher flux (6x10{sup 13} photons/sec) or higher resolution (minimum q < 0.001 nm{sup −1}), focusing and collimation, respectively need to be varied. For a sample-to-detector distance of 31 m and 0.1 nm wavelength, two dimensional ultra small-angle X-ray scattering patterns can be recorded down to q≈0.001 nm{sup −1} with far superior quality as compared to one dimensional profiles obtained with a Bonse-Hart instrument.

43 PARTICLE ACCELERATORS↗

A sample holder for simultaneous Raman and neutron vibrational spectroscopy

We have built a sample holder (called a center stick or sample stick) for performing simultaneous Raman and neutron vibrational spectroscopy on samples of material at the VISION neutron vibrational spectrometer of the Spallation Neutron Source at Oak Ridge National Laboratory. This equipment holds material samples in the neutron beam within the cryogenic environment of the VISION spectrometer, allowing for samples to be studied at temperatures as low as 5 K. It also provides the capability for gas to be loaded to or evacuated from the sample while it is loaded at VISION. The optical components for directing and filtering light are located within the cryogenic volume, in physical proximity to the sample. We describe the construction of this sample holder and discuss our first measurements of simultaneous Raman and neutron vibrational spectra. Here, the samples that we report on were of 4-nitrophenol at a temperature of 20 K and of cryogenic hydrogen of a number of different orthohydrogen fractions.

4-nitrophenol↗

Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas

A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, thus improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗